RESUMO
This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.
Assuntos
Radiografia Dentária Digital , Radiografia Dentária Digital/métodosRESUMO
Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.
Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.
RESUMO
OBJECTIVE: To qualitatively and quantitatively assess integrated segmentation of three convolutional neural network (CNN) models for the creation of a maxillary virtual patient (MVP) from cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: A dataset of 40 CBCT scans acquired with different scanning parameters was selected. Three previously validated individual CNN models were integrated to achieve a combined segmentation of maxillary complex, maxillary sinuses, and upper dentition. Two experts performed a qualitative assessment, scoring-integrated segmentations from 0 to 10 based on the number of required refinements. Furthermore, experts executed refinements, allowing performance comparison between integrated automated segmentation (AS) and refined segmentation (RS) models. Inter-observer consistency of the refinements and the time needed to create a full-resolution automatic segmentation were calculated. RESULTS: From the dataset, 85% scored 7-10, and 15% were within 3-6. The average time required for automated segmentation was 1.7 min. Performance metrics indicated an excellent overlap between automatic and refined segmentation with a dice similarity coefficient (DSC) of 99.3%. High inter-observer consistency of refinements was observed, with a 95% Hausdorff distance (HD) of 0.045 mm. CONCLUSION: The integrated CNN models proved to be fast, accurate, and consistent along with a strong interobserver consistency in creating the MVP. CLINICAL RELEVANCE: The automated segmentation of these structures simultaneously could act as a valuable tool in clinical orthodontics, implant rehabilitation, and any oral or maxillofacial surgical procedures, where visualization of MVP and its relationship with surrounding structures is a necessity for reaching an accurate diagnosis and patient-specific treatment planning.
Assuntos
Implantes Dentários , Dente , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Redes Neurais de ComputaçãoRESUMO
Abstract The aim of this study was to assess the use of digital dental radiology in Brazil, by focusing on the use of image receptors, imaging exams and digital image enhancement tools, also assessing the methods of professional image transfer. Questionnaires were distributed in person on dental meetings and digitally via messaging (WhatsApp®) and mailings list. The sample of this cross-sectional study consisted of 478 questionnaires. Most participants were woman (n=315, 65.9%), with average age of 33.8±9.2 years. Descriptive and frequency analysis was performed. Chi-square and Fisher's exact tests were used (α=0.05). Most dentists worked at shared dental clinics (34.7%) and use digital image receptors (51.1%), but a representative percentage (48.9%) still exclusively use radiographic films. Photostimulable phosphor plate is the most used digital image receptor. Among extraoral exams, panoramic radiography (PAN) is the most used. Regarding dental specialties, oral radiologists and oral and maxillofacial surgeons mostly use cone-beam computed tomography (p<0.001). Most dentists who use digital systems make use of digital image enhancement tools (87.8%), mainly contrast, zoom, brightness and measurements. The most common method of professional image transfer (professional-professional and professional-patiens) is by email, with few dentists using online app and social media (26%). Therefore, while most Brazilian dentists use digital imaging systems, a significant percentage still exclusively use radiographic films. The most extraoral imaging exams used is PAN. Regarding image enhancement tools, brightness and contrast adjustments, zoom and measurements are the most applied. Finally, dentists generally use email for professional image transfer.
Resumen El objetivo de este estudio fue evaluar uso de la radiología dental digital en Brasil, centrándose en uso de receptores de imagen, exámenes de imágenes y herramientas de mejora de imagen digital, evaluando también los métodos de transferencia de imagen profesional. Cuestionarios se distribuyeron de forma presencial en reuniones odontológicas y de forma digital a través de mensajería (WhatsApp®) y lista de correo. Muestra de este estudio transversal estuvo compuesta por 478 cuestionarios. Mayoría de los participantes eran mujeres (n=315, 65,9%), con edad promedio de 33,8±9,2 años. Se realizó un análisis descriptivo y de frecuencias. Se utilizaron las pruebas Chi-cuadrado y exacta de Fisher (α=0,05). La mayoría de los odontólogos trabajaban en clínicas dentales compartidas (34,7%) y utilizan receptores de imágenes digitales (51,1%), pero un porcentaje representativo (48,9%) todavía utiliza exclusivamente películas radiográficas. Placa de fósforo fotoestimulable es el receptor de imagen digital más utilizado. Entre los exámenes extraorales, la radiografía panorámica (PAN) es la más utilizada. En cuanto a las especialidades odontológicas, los radiólogos orales y los cirujanos orales y maxilofaciales utilizan mayoritariamente la tomografía computarizada de haz cónico (p<0,001). Mayoría de los odontólogos que utilizan sistemas digitales utilizan herramientas de mejora de imagen digital (87,8%), principalmente contraste, zoom, brillo y medidas. Método más común de transferencia de imágenes profesionales (profesional-profesional y profesional-pacientes) es por correo electrónico, con pocos dentistas que utilizan aplicaciones en línea y redes sociales (26%). Por lo tanto, mientras que la mayoría de dentistas brasileños utilizan sistemas de imágenes digitales, un porcentaje significativo aún utiliza exclusivamente películas radiográficas. Examen de imagen extraoral más utilizado es el PAN. En cuanto a las herramientas de mejora de imagen, los ajustes de brillo y contraste, el zoom y las medidas son las más aplicadas. Finalmente, los dentistas generalmente usan el correo electrónico para la transferencia de imágenes profesionales.
Assuntos
Intensificação de Imagem Radiográfica/tendências , Sistemas de Informação em Radiologia , Brasil , Diagnóstico por ImagemRESUMO
OBJECTIVE: To evaluate the influence of the file format of digital periapical radiographs on the diagnosis of vertical root fracture (VRF). STUDY DESIGN: Periapical radiographic images of 34 single-rooted teeth-19 with VRF, and 15 without VRF were acquired using two digital systems-Digora Toto, and Digora Optime, and exported into four different file formats-TIFF, BMP, PNG, and JPEG, totaling 272 radiographs. The radiographs were assessed by five examiners for the detection of VRF, using a 5-point scale (1-definitely absent; 2-probably absent; 3-uncertain; 4-probably present; 5-definitely present). Diagnostic values of area under the ROC curve, specificity, and sensitivity for the diagnosis of VRF were calculated. The results were compared by two-way Analysis of Variance with post hoc Tukey's test. The intra- and inter-examiner agreements were measured by the Kappa test. The significance level was set at 5% for all analyses. RESULTS: The values of intra-examiner agreement varied from moderate (0.56) to almost perfect (0.81), while the values of inter-examiner agreement varied from fair (0.29) to moderate (0.60). The image file format did not influence the diagnostic values for VRF for any of the radiographic systems tested (p > 0.05). Digora Toto had significantly greater values of area under the ROC curve than Digora Optime for all file formats (p = 0.001). CONCLUSION: The image file format of periapical radiographs does not influence the diagnosis of VRF, regardless of the digital radiography system.
Assuntos
Fraturas dos Dentes , Humanos , Compostos de Quinolínio , Radiografia , Radiografia Dentária Digital/métodos , Tiazóis , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagemRESUMO
OBJECTIVE: To determine the prevalence of the elongated styloid process (ESP) and its characteristics, such as sex and age of the patient, unilateral and bilateral incidence, besides variations between different populations and panoramic and CBCT examinations. MATERIALS AND METHODS: A search was performed in six databases (PubMed, Web of Science, Scopus, Cochrane, Lilacs, and Embase) to identify observational studies that used imaging exams and assessed ESP prevalence among panoramic radiograph CBCT examinations, whose transversal prevalence studies were included. Furthermore, studies with a specific group of patients or symptomatic patients were excluded. Additionally, Joanna Briggs Institute checklist was used to evaluate the quality of the studies. A meta-analysis was conducted, then subgroup analyses were performed by grouping studies according to the secondary outcomes, with a significance level set at 5%. The Grading of Recommendations Assessment, Development, and Evaluation system was used to rate the certainty in the evidence. RESULTS: The initial search resulted in 1635 studies, from which 39 articles met the inclusion criteria, encompassing 50,655 participants. The sample size varied between 82 and 5,000 participants. The prevalence of the ESP ranged from 1.3 to 94.8%, with an overall prevalence of 30.2%. The bilateral occurrence was higher than the unilateral one, but no significant predilection was observed according to sex, age, or population. The type of imaging examination also showed no difference in its detection. CONCLUSION: The overall prevalence of ESP was 30.2%, with a propensity for bilaterality, but not for any sex, age, or population geographic location. The imaging examination modality did not influence the diagnosis of ESP. However, the quality level of the studies evaluated was very low, demonstrating the need for more homogeneous primary studies on the prevalence of the ESP with a more standardized methodology. CLINICAL RELEVANCE: There is no consensus in the literature regarding the prevalence of the ESP and the characteristics of the affected patients that can cause chronic and debilitating discomfort in the head and neck region. Therefore, knowledge about the prevalence and characteristics of this condition would help dental clinicians reach the correct diagnosis.