Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Gastroenterol ; 19(1): 30, 2019 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-30760205

RESUMO

BACKGROUND: Inflammatory Bowel Disease (IBD) with its high incidence and prevalence rates in Canada generates a heavy burden of tests and procedures. The purpose of this study is to gain a better understanding of the transfer of information from physician to patient, as well as the patient understanding and perceptions about the tests and procedures that are ordered to them in the context of IBD diagnosis and monitoring. METHODS: An online questionnaire was completed by 210 IBD patients in Canada. Information on the five most-often used tests or procedures in IBD diagnosis/monitoring was collected. These include: general blood test, colonoscopy, colon biopsy, medical imaging and stool testing. RESULTS: The general blood test is both the most ordered and most refused tool. It is also the one with which patients are the least comfortable, the one that generates the least concern and the one about which physicians provide the least information. The stool test is the test/procedure with which patients are the most comfortable. Procedures raise more concerns among patients and physicians provide more information about why they are needed, their impact and the risks they present. Very little information is provided to patients about the risks of having false positives or negative tests. CONCLUSIONS: This study provides an initial understanding of patient perceptions, the transfer of information from a physician to a patient and a patient's understanding of the tests and procedures that will be required to treat IBD throughout what is a lifelong disease. The present study takes a first step in better understanding the acceptance of the test or procedure by IBD patients, which is essential for them to adhere to the monitoring process.


Assuntos
Doenças Inflamatórias Intestinais/diagnóstico , Doenças Inflamatórias Intestinais/psicologia , Aceitação pelo Paciente de Cuidados de Saúde , Educação de Pacientes como Assunto , Percepção , Adolescente , Adulto , Canadá/epidemiologia , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Incidência , Doenças Inflamatórias Intestinais/epidemiologia , Doenças Inflamatórias Intestinais/terapia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Prevalência , Qualidade de Vida , Inquéritos e Questionários , Recusa do Paciente ao Tratamento , Adulto Jovem
2.
Patient Educ Couns ; 101(2): 331-339, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28760459

RESUMO

OBJECTIVES: This study aims to characterize the relationships between the quality of the information given by the physician, the involvement of the patient in shared decision making (SDM), and outcomes in terms of satisfaction and anxiety pertaining to the treatment of inflammatory bowel disease (IBD). METHODS: A Web survey was conducted among 200 Canadian patients affected with IBD. The theoretical model of SDM was adjusted using path analysis. SAS software was used for all statistical analyses. RESULTS: The quality of the knowledge transfer between the physician and the patient is significantly associated with the components of SDM: information comprehension, patient involvement and decision certainty about the chosen treatment. In return, patient involvement in SDM is significantly associated with higher satisfaction and, as a result, lower anxiety as regards treatment selection. CONCLUSIONS: This study demonstrates the importance of involving patients in shared treatment decision making in the context of IBD. PRACTICE IMPLICATIONS: Understanding shared decision making may motivate patients to be more active in understanding the relevant information for treatment selection, as it is related to their level of satisfaction, anxiety and adherence to treatment. This relationship should encourage physicians to promote shared decision making.


Assuntos
Ansiedade/psicologia , Tomada de Decisões , Doenças Inflamatórias Intestinais/terapia , Participação do Paciente , Relações Médico-Paciente , Adulto , Atitude do Pessoal de Saúde , Canadá , Feminino , Humanos , Doenças Inflamatórias Intestinais/psicologia , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Percepção
3.
J Biomed Opt ; 20(12): 126007, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26720874

RESUMO

With the increasing use of optical coherence tomography (OCT) in biomedical applications, robust yet simple methods for calibrating and benchmarking a system are needed. We present here a procedure based on a calibration object complemented with an algorithm that analyzes three-dimensional OCT datasets to retrieve key characteristics of an OCT system. The calibration object combines state-of-the-art tissue phantom material with a diamond-turned aluminum multisegment mirror. This method is capable of determining rapidly volumetric field-of-view, axial resolution, and image curvature. Moreover, as the phantom material mimics biological tissue, the system's signal and noise levels can be evaluated in conditions close to biological experiments. We believe this method could improve OCT quantitative data analysis and help OCT data comparison for longitudinal or multicenter studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Algoritmos , Alumínio/química , Automação , Calibragem , Desenho de Equipamento , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Software
4.
Opt Express ; 18(11): 11495-507, 2010 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-20589010

RESUMO

Development, production quality control and calibration of optical tissue-mimicking phantoms require a convenient and robust characterization method with known absolute accuracy. We present a solid phantom characterization technique based on time resolved transmittance measurement of light through a relatively small phantom sample. The small size of the sample enables characterization of every material batch produced in a routine phantoms production. Time resolved transmittance data are pre-processed to correct for dark noise, sample thickness and instrument response function. Pre-processed data are then compared to a forward model based on the radiative transfer equation solved through Monte Carlo simulations accurately taking into account the finite geometry of the sample. The computational burden of the Monte-Carlo technique was alleviated by building a lookup table of pre-computed results and using interpolation to obtain modeled transmittance traces at intermediate values of the optical properties. Near perfect fit residuals are obtained with a fit window using all data above 1% of the maximum value of the time resolved transmittance trace. Absolute accuracy of the method is estimated through a thorough error analysis which takes into account the following contributions: measurement noise, system repeatability, instrument response function stability, sample thickness variation refractive index inaccuracy, time correlated single photon counting system time based inaccuracy and forward model inaccuracy. Two sigma absolute error estimates of 0.01 cm(-1) (11.3%) and 0.67 cm(-1) (6.8%) are obtained for the absorption coefficient and reduced scattering coefficient respectively.


Assuntos
Materiais Biomiméticos , Nefelometria e Turbidimetria/instrumentação , Dispositivos Ópticos , Imagens de Fantasmas , Análise Espectral/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Luz , Espalhamento de Radiação
5.
J Biomed Opt ; 13(4): 041314, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19021322

RESUMO

The time-resolved fluorescence of photosensitizers (PSs) of varying hydrophobicities, di-and tetrasulfonated Al phthalocyanines (Al-2 and Al-4), and Photochlor (HPPH), was investigated in liposomes used as cell-mimetic models. Using frequency-and time-domain apparatus, the fluorescence lifetime, tau(fluo), was compared for PSs free in aqueous solution and in a liposome-associated state at varied temperatures (25 to 78 degrees C) and oxygen concentrations (0-190 microM). The analysis of tau(fluo) revealed different decay behaviors for the free-solution and liposome-confined PSs, most significantly for the lipophilic HPPH. Hydrophilic PS drugs (Al-4, Al-2) were less affected by the liposomal confinement, depending on the relative hydrophilicity of the compound and the consequent localization in liposomes. Changes in the emission decay due to confinement were detected as differences in the lifetime between the bulk solution and the liposome-localized PS in response to heating and deoxygenation. Specifically, hydrophilic Al-4 produced an identical lifetime trend as a function of temperature both in solu and in a liposome-confined state. Hydrophobic HPPH exhibited a fundamental transformation in its fluorescence decay kinetics, transitioning from a multiexponential (in free solution) to single-exponential (in liposome) decay. Deoxygenation resulted in a ubiquitous tau(fluo) increase for all PSs in free solution, while the opposite, a tau(fluo) decrease, occurred in all liposomal PSs.


Assuntos
Portadores de Fármacos/química , Lipossomos/química , Oxigênio/química , Fármacos Fotossensibilizantes/química , Temperatura Alta , Interações Hidrofóbicas e Hidrofílicas , Luz , Teste de Materiais , Fotoquímica/métodos , Espalhamento de Radiação
6.
J Biomed Opt ; 13(4): 041313, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19021321

RESUMO

Preferential tumor localization and the aggregation state of photosensitizers (PSs) can depend on the hydrophilic/hydrophobic nature of the molecule and affect their phototoxicity. In this study, three PSs of different hydrophilicity are introduced in liposomes to understand the structure-photochemistry relationship of PSs in this cellular model system. Absorbance and fluorescence spectra of amphiphilic aluminum (III) phthalocyanine disulfonate chloride adjacent isomer (Al-2), hydrophilic aluminum (III) phthalocyanine chloride tetrasulfonic acid (Al-4), and lipophilic 2-(1-hexyloxyethyl)-2-devinyl pyropheophorbide (HPPH) are compared in a liposomal confined state with free PS in bulk solution. For fluorescence measurements, a broad range of concentrations of both bulk and liposomal confined PSs are examined to track the transition from monomers to dimers or higher order aggregates. Epifluorescence microscopy, absorbance, and fluorescence measurements all confirm different localization of the PSs in liposomes, depending on their hydrophilicity. In turn, the localization affects the aggregation of molecules inside the liposome cell model. Data obtained with such cellular models could be useful in optimizing the photochemical properties of photosensitizing drugs based on their structure-dependent interactions with cellular media and subcellular organelles.


Assuntos
Portadores de Fármacos/química , Lipossomos/química , Fármacos Fotossensibilizantes/química , Interações Hidrofóbicas e Hidrofílicas , Luz , Teste de Materiais , Fotoquímica/métodos , Espalhamento de Radiação
7.
Appl Spectrosc ; 58(8): 1010-9, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15324509

RESUMO

The goal of this research was to develop a simple and economical fiber-optic sensor technology for agrifood process monitoring. Toward this end, two fiber-optic sensors were developed to be used in combination: a single reflection V-bend sensor and a single fiber air-gap probe. The former is designed to be sensitive toward refractive index and the latter towards absorption. Experiments indicate that the micromachined V-bend fiber refractometer is most sensitive when the bend angle is centered around 140 degrees, at which angle the sensor may resolve changes in refractive index as small as 0.00015. Additionally, the V-bend sensor was found to be non-responsive toward sample absorption even in extremely absorbing solutions. The air-gap design absorption sensor, most commonly used for measurements in highly colored media, was found to be slightly sensitive towards refractive index. When the two sensors are used together, the response of the absorption sensor may be corrected for. This sensor combination is able to provide accurate measurements in situations where Beer's law is not obeyed. Results are presented that show that the sensor pair was successfully used to monitor wine sugar content (Brix), and color density and hue, parameters related to the age of the wine.


Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Monitoramento Ambiental/instrumentação , Tecnologia de Fibra Óptica , Vinho/análise , Vinho/normas , Absorção , Fibras Ópticas , Controle de Qualidade , Refratometria
8.
J Agric Food Chem ; 50(6): 1587-92, 2002 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-11879041

RESUMO

The aim of this study was to determine if peptides could interact with beta-lactoglobulin (beta-LG) and what the physicochemical conditions promoting their interaction with the protein are. The binding of negatively charged (beta-LG 125-135 and 130-135), positively charged (beta-LG 69-83 and 146-149), and hydrophobic (alphaS1-CN 23-34 and beta-LG 102-105, both bioactive peptides) peptides to bovine beta-LG was determined using an ultrafiltration method under different physicochemical conditions: pH 3.0, 6.8, and 8.0; buffers of 0.05 and 0.1 M; 4, 25, and 40 degrees C; beta-LG/peptide ratios of 1:5 and 1:10. At pH 3.0, none of the peptides interacted with beta-LG at any temperature, buffer molarity, or beta-LG/peptide ratio probably due to electrostatic repulsions between the highly protonated species. At pH 6.8 and 8.0, charged peptides beta-LG 130-135, 69-83, and 146-149 bound to beta-LG under some physicochemical conditions, possibly by nonspecific binding. However, both hydrophobic peptides probably bind to the inner cavity (beta-barrel) of beta-LG, provoking the release of materials absorbing at 214 nm. Given the known biological activities of the hydrophobic peptides used in this study (opioid and ACE-inhibitory activities), their binding to beta-LG may be relevant to a better understanding of the physiological function of the protein.


Assuntos
Lactoglobulinas/química , Fragmentos de Peptídeos/química , Sequência de Aminoácidos , Inibidores da Enzima Conversora de Angiotensina/química , Animais , Soluções Tampão , Bovinos , Fenômenos Químicos , Físico-Química , Cromatografia Líquida de Alta Pressão , Interações Medicamentosas , Concentração de Íons de Hidrogênio , Peptídeos Opioides/química , Eletricidade Estática , Ultrafiltração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...