1.
Sci Rep ; 14(1): 11110, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750033

RESUMO

A novel programmable implantable neurostimulation platform based on photonic power transfer has been developed for various clinical applications with the main focus of being safe to use with MRI scanners. The wires usually conveying electrical current from the neurostimulator to the electrodes are replaced by optical fibers. Photovoltaic cells at the tip of the fibers convert laser light to biphasic electrical impulses together with feedback signals with 54% efficiency. Furthermore, a biocompatible, implantable and ultra-flexible optical lead was developed including custom optical fibers. The neurostimulator platform incorporates advanced signal processing and optical physiological sensing capabilities thanks to a hermetically sealed transparent nonmetallic casing. Skin transparency also allowed the development of a high-speed optical transcutaneous communication channel. This implantable neurostimulation platform was first adapted to a vagus nerve stimulator for the treatment of epilepsy. This neurostimulator has been designed to fulfill the requirements of a class III long-term implantable medical device. It has been proven compliant with standard ISO/TS10974 for 1.5 T and 3 T MRI scanners. The device poses no related threat and patients can safely undergo MRI without specific or additional precautions. Especially, the RF induced heating near the implant remains below 2 °C whatever the MRI settings used. The main features of this unique advanced neurostimulator and its architecture are presented. Its functional performance is evaluated, and results are described with a focus on optoelectronics aspects and MRI safety.


Assuntos
Neuroestimuladores Implantáveis , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/efeitos adversos , Humanos , Desenho de Equipamento
2.
Biomedicines ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38540170

RESUMO

This study investigates the dose-dependent EEG effects of Vagus Nerve Stimulation (VNS) in patients with drug-resistant epilepsy. This research examines how varying VNS intensities impacts EEG power spectrum and synchronization in a cohort of 28 patients. Patients were categorized into responders, partial-responders, and non-responders based on seizure frequency reduction. The methods involved EEG recordings at incremental VNS intensities, followed by spectral and synchronization analysis. The results reveal significant changes in EEG power, particularly in the delta and beta bands across different intensities. Notably, responders exhibited distinct EEG changes compared to non-responders. Our study has found that VNS intensity significantly influences EEG power topographic allocation and brain desynchronization, suggesting the potential use of acute dose-dependent effects to personalized VNS therapy in the treatment of epilepsy. The findings underscore the importance of individualized VNS dosing for optimizing therapeutic outcomes and highlight the use of EEG metrics as an effective tool for monitoring and adjusting VNS parameters. These insights offer a new avenue for developing individualized VNS therapy strategies, enhancing treatment efficacy in epilepsy.

3.
Ear Hear ; 45(2): 400-410, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37828657

RESUMO

OBJECTIVES: Commercially available auditory steady state response (ASSR) systems are widely used to obtain hearing thresholds in the pediatric population objectively. Children are often examined during natural or induced sleep so that the recorded ASSRs are of subcortical origin, the inferior colliculus being often designated as the main ASSR contributor in these conditions. This report presents data from a battery of auditory neurophysiological objective tests obtained in 3 cases of severe brainstem dysfunction in sleeping children. In addition to ASSRs, envelope-following response (EFR) recordings designed to distinguish peripheral (cochlear nerve) from central (brainstem) were recorded to document the effect of brainstem dysfunction on the two types of phase-locked responses. DESIGN: Results obtained in the 3 children with severe brainstem dysfunctions were compared with those of age-matched controls. The cases were identified as posterior fossa tumor, undiagnosed (UD), and Pelizaeus-Merzbacher-Like Disease. The standard audiological objective tests comprised tympanograms, distortion product otoacoustic emissions, click-evoked auditory brainstem responses (ABRs), and ASSRs. EFRs were recorded using horizontal (EFR-H) and vertical (EFR-V) channels and a stimulus phase rotation technique allowing isolation of the EFR waveforms in the time domain to obtain direct latency measurements. RESULTS: The brainstem dysfunctions of the 3 children were revealed as abnormal (weak, absent, or delayed) ABRs central waves with a normal wave I. In addition, they all presented a summating and cochlear microphonic potential in their ABRs, coupled with a normal wave I, which implies normal cochlear and cochlear nerve function. EFR-H and EFR-V waveforms were identified in the two cases in whom they were recorded. The EFR-Hs onset latencies, response durations, and phase-locking values did not differ from their respective age-matched control values, indicating normal cochlear nerve EFRs. In contrast, the EFR-V phase-locking value and onset latency varied from their control values. Both patients had abnormal but identifiable and significantly phase-locked brainstem EFRs, even in a case with severely distorted ABR central waves. ASSR objective audiograms were recorded in two cases. They showed normal or slightly elevated (explained by a slight transmission loss) thresholds that do not yield any clue about their brainstem dysfunction, revealing the method's lack of sensitivity to severe brainstem dysfunction. CONCLUSIONS: The present study, performed on 3 sleeping children with severe brainstem dysfunction but normal cochlear responses (cochlear microphonic potential, summating potential, and ABR wave I), revealed the differential sensitivity of three auditory electrophysiological techniques. Estimated thresholds obtained by standard ASSR recordings (cases UD and Pelizaeus-Merzbacher-Like Disease) provided no clue to the brainstem dysfunction clearly revealed by the click-evoked ABR. EFR recordings (cases posterior fossa tumor and UD) showed preserved central responses with abnormal latencies and low phase-locking values, whereas the peripheral EFR attributed to the cochlear nerve was normal. The one case (UD) for which the three techniques could be performed confirms this sensitivity gradient, emphasizing the need for applying the Cross-Check Principle by avoiding resorting to ASSR recording alone. The entirely normal EFR-H recordings observed in two cases further strengthen the hypothesis of its cochlear nerve origin in sleeping children.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Neoplasias Infratentoriais , Humanos , Criança , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audição/fisiologia , Tronco Encefálico , Estimulação Acústica
4.
Artigo em Inglês | MEDLINE | ID: mdl-38083348

RESUMO

Infrared neural stimulation (INS) is a neuromodulation technique that involves short optical pulses delivered to the neural tissue, resulting in the initiation of action potentials. In this work, we studied the compound neural action potentials (CNAP) generated by INS in five ex vivo sciatic nerves. A 1470 nm laser emitting a sequence of 0.4 ms light pulses with a peak power of 10 W was used. A single 4 mJ stimulus is not capable of eliciting a nerve response. However, repetition of the optical stimuli resulted in the induction of CNAPs. Heat accumulation induced by repetition rates as high as 10 Hz may be involved in the increase in CNAP amplitude. This sensitization effect may help to reduce the pulse energy required to evoke CNAP. In addition, these results highlight the importance of investigating the role of the slow nerve temperature dynamics in INS.


Assuntos
Temperatura Alta , Raios Infravermelhos , Ratos , Animais , Nervo Isquiático/fisiologia , Potenciais de Ação/fisiologia , Potenciais Evocados
5.
Artigo em Inglês | MEDLINE | ID: mdl-38083580

RESUMO

This paper aims to question the sustainability of biomedical engineering practices. The strong sustainability framework is applied to the evaluation and development of medical technologies through the definition of clinical sustainability. A roadmap for developing and evaluating medical technologies in this respect is derived from this framework, as a first step toward a multidisciplinary evaluation tool. On this basis, the current trend towards disposable endoscopes is analyzed and discussed. This highlights the subtle balance between economic, clinical, social, and environmental factors, the lack of evidence at these multiple levels, and the need for multidisciplinarity. This paper concludes with the need to assess all aspects of sustainability and identify and quantify the trade-offs, instead of focusing on one or two key indicators, to have more relevant information in order to make better and more effective decisions. Towards sustainable healthcare, we outline two paths of action: (1) providing evidence that is lacking on the environmental impact of existing or currently developed medical technologies and (2) clarifying the premises and visions underlying our practices.Clinical Relevance- This work provides insights regarding the strong sustainability of medical technologies. This clinical framework may help clinicians and developers in decision-making to reduce indirect negative ecological, social, and health impacts.


Assuntos
Equipamentos Descartáveis , Endoscópios , Desenvolvimento Sustentável
6.
Brain Sci ; 13(11)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38002525

RESUMO

This paper investigates brain-behaviour associations between interictal epileptic discharges and cognitive performance in a population of children with self-limited focal epilepsy with centro-temporal spikes (SeLECTS). Sixteen patients with SeLECTS underwent an extensive neuropsychological assessment, including verbal short-term and episodic memory, non-verbal short-term memory, attentional abilities and executive function. Two quantitative EEG indices were analysed, i.e., the Spike Wave Index (SWI) and the Spike Wave Frequency (SWF), and one qualitative EEG index, i.e., the EEG score, was used to evaluate the spreading of focal SW to other parts of the brain. We investigated associations between EEG indices and neuropsychological performance with non-parametric Spearman correlation analyses, including correction for multiple comparisons. The results showed a significant negative correlation between (i) the awake EEG score and the Block Tapping Test, a visuo-spatial short-term memory task, and (ii) the sleep SWI and the Tower of London, a visuo-spatial planning task (pcorr < 0.05). These findings suggest that, in addition to the usual quantitative EEG indices, the EEG analysis should include the qualitative EEG score evaluating the spreading of focal SW to other parts of the brain and that neuropsychological assessment should include visuo-spatial skills.

8.
J Neural Eng ; 20(4)2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37595607

RESUMO

Objective. In 1/3 of patients, anti-seizure medications may be insufficient, and resective surgery may be offered whenever the seizure onset is localized and situated in a non-eloquent brain region. When surgery is not feasible or fails, vagus nerve stimulation (VNS) therapy can be used as an add-on treatment to reduce seizure frequency and/or severity. However, screening tools or methods for predicting patient response to VNS and avoiding unnecessary implantation are unavailable, and confident biomarkers of clinical efficacy are unclear.Approach. To predict the response of patients to VNS, functional brain connectivity measures in combination with graph measures have been primarily used with respect to imaging techniques such as functional magnetic resonance imaging, but connectivity graph-based analysis based on electrophysiological signals such as electroencephalogram, have been barely explored. Although the study of the influence of VNS on functional connectivity is not new, this work is distinguished by using preimplantation low-density EEG data to analyze discriminative measures between responders and non-responder patients using functional connectivity and graph theory metrics.Main results. By calculating five functional brain connectivity indexes per frequency band upon partial directed coherence and direct transform function connectivity matrices in a population of 37 refractory epilepsy patients, we found significant differences (p< 0.05) between the global efficiency, average clustering coefficient, and modularity of responders and non-responders using the Mann-Whitney U test with Benjamini-Hochberg correction procedure and use of a false discovery rate of 5%.Significance. Our results indicate that these measures may potentially be used as biomarkers to predict responsiveness to VNS therapy.


Assuntos
Epilepsia Resistente a Medicamentos , Estimulação do Nervo Vago , Humanos , Encéfalo , Próteses e Implantes , Eletroencefalografia
9.
Biomed Phys Eng Express ; 9(5)2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-37406619

RESUMO

Objective.Phantoms that mimic healthy or diseased organ properties can complement animal models for surgical planning, training, and medical device development. If urodynamic studies rely on pressure-volume curves to assess lower urinary tract symptoms, there is an unsatisfied need for a bladder phantom that accurately mimics the bladder stretching capabilities and compliant behaviour during physiological filling.Approach.We demonstrate the suitability of water-soluble 3D-printed moulds as a versatile method to fabricate accurate phantoms with anatomical structures reconstructed from medical images. We report a phantom fabricated with silicone rubber. A wire net limits the silicone expansion to model the cystometric capacity. A mathematical model describes the pressure increase due to passive hyperelastic properties.Main results.The phantom reproduces the bladder's mechanical properties during filling. The pressure-volume curve measured on the phantom is typical of cystometric studies, with a compliance of 25.2 ± 1mlcmH2O-1.The root-mean-square error between the theoretical model and experimental data is 2.7cmH2O.The compliance, bladder wall thickness, cystometric capacity and pressure near the cystometric capacity of the phantom can be tuned to mimic various pathologies or human variability.Significance.The manufacturing method is suitable for fabricating bladder and other soft and hollow organ phantoms. The mathematical model provides a method to determine design parameters to model healthy or diseased bladders. Soft hollow organ phantoms can be used to complement animal experimentations for developing and validating medical devices aiming to be anchored on these organs or monitor their activity through pressure and strain measurement.


Assuntos
Pelve , Bexiga Urinária , Animais , Humanos , Bexiga Urinária/patologia , Pressão , Imagens de Fantasmas , Silicones
10.
Clin Neurophysiol ; 147: 99-107, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36764043

RESUMO

OBJECTIVE: The objective of the study was to record Laryngeal Motor Evoked Potentials (LMEPs) in Vagus Nerve Stimulation (VNS)-implanted patients suffering from Drug-Resistant Epilepsy (DRE). Based on these recordings, LMEPs characteristics were evaluated and compared between responders (R) and non-responders (NR). Finally, possible under- or over-stimulation was assessed based on a physiological indicator of fiber engagement. METHODS: Mean dose-response curves were compared between R and NR. A Support Vector Machine (SVM) model was built based on both LMEP and dose-response curves features, to discriminate R from NR. For the exploration of possible under- or over-stimulation, a ratio between the clinically applied stimulation intensity and the intensity yielding to LMEP saturation was computed for each patient. RESULTS: A trend towards a greater excitability of the nerve was observed in R compared to NR. The SVM classifier discriminated R and NR with an accuracy of 80%. An ineffective attempt to overstimulate at current levels above what is usually necessary to obtain clinical benefits was suggested in NR. CONCLUSIONS: The SVM model built emphasizes a possible link between vagus nerve recruitment characteristics and treatment effectiveness. Most of the clinically responding patients receive VNS at a stimulation intensity 1-fold and 2-fold the intensity inducing LMEP saturation. SIGNIFICANCE: LMEP saturation could be a practical help in guiding the titration of the stimulation parameters using a physiological indicator of fiber engagement.


Assuntos
Epilepsia Resistente a Medicamentos , Laringe , Estimulação do Nervo Vago , Humanos , Potencial Evocado Motor , Nervo Vago/fisiologia , Epilepsia Resistente a Medicamentos/etiologia , Resultado do Tratamento
11.
Brain Stimul ; 15(6): 1498-1507, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36402376

RESUMO

BACKGROUND: Modulation of the locus coeruleus (LC)-noradrenergic system is a key mechanism of vagus nerve stimulation (VNS). Activation of the LC produces pupil dilation, and the VNS-induced change in pupil diameter was demonstrated in animals as a possible dose-dependent biomarker for treatment titration. OBJECTIVE: This study aimed to characterize VNS-induced pupillary responses in epileptic patients. METHODS: Pupil diameter was recorded in ten epileptic patients upon four stimulation conditions: three graded levels of VNS intensity and a somatosensory control stimulation (cutaneous electrical stimulation over the left clavicle). For each block, the patients rated the intensity of stimulation on a numerical scale. We extracted the latency of the peak pupil dilation and the magnitude of the early (0-2.5 s) and late components (2.5-5 s) of the pupil dilation response (PDR). RESULTS: VNS elicited a peak dilation with longer latency compared to the control condition (p = 0.043). The magnitude of the early PDR was significantly correlated with the intensity of perception (p = 0.046), whereas the late PDR was not (p = 0.19). There was a significant main effect of the VNS level of intensity on the magnitude of the late PDR (p = 0.01) but not on the early PDR (p = 0.2). The relationship between late PDR magnitude and VNS intensity was best fit by a Gaussian model (inverted-U). CONCLUSIONS: The late component of the PDR might reflect specific dose-dependent effects of VNS, as compared to control somatosensory stimulation. The inverted-U relationship of late PDR with VNS intensity might indicate the engagement of antagonist central mechanisms at high stimulation intensities.


Assuntos
Epilepsia , Estimulação do Nervo Vago , Animais , Epilepsia/terapia , Locus Cerúleo/fisiologia , Nervo Vago/fisiologia
12.
Sci Rep ; 12(1): 11336, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35790848

RESUMO

Non-convulsive seizures and status epilepticus are frequent and associated with increased mortality in septic patients. However, the mechanism through which seizures impact outcome in these patients is unclear. As previous studies yielded an alteration of neurovascular coupling (NVC) during sepsis, we hypothesized that non-convulsive seizures, might further impair NVC, leading to brain tissue hypoxia. We used a previously developed ovine model of sepsis. Animals were allocated to sham procedure or sepsis; septic animals were studied either during the hyperdynamic phase (sepsis group) or after septic shock occurrence (septic shock group). After allocation, seizures were induced by cortical application of penicillin. We recorded a greater seizure-induced increase in the EEG gamma power in the sepsis group than in sham. Using a neural mass model, we also found that the theoretical activity of the modeled inhibitory interneurons, thought to be important to reproduce gamma oscillations, were relatively greater in the sepsis group. However, the NVC was impaired in sepsis animals, despite a normal brain tissue oxygenation. In septic shock animals, it was not possible to induce seizures. Cortical activity declined in case of septic shock, but it did not differ between sham or sepsis animals. As the alteration in NVC preceded cortical activity reduction, we suggest that, during sepsis progression, the NVC inefficiency could be partially responsible for the alteration of brain function, which might prevent seizure occurrence during septic shock. Moreover, we showed that cardiac output decreased during seizures in sepsis animals instead of increasing as in shams. The alteration of the seizure-induced systemic hemodynamic variations in sepsis might further affect cerebrovascular response to neuronal activation. Our findings support the hypothesis that anomalies in the cerebral blood flow regulation may contribute to the sepsis-associated encephalopathy and that seizures might be dangerous in such a vulnerable setting.


Assuntos
Excitabilidade Cortical , Sepse , Choque Séptico , Animais , Hemodinâmica , Convulsões , Sepse/complicações , Ovinos
13.
J Biophotonics ; 15(10): e202200028, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35703916

RESUMO

The measurement of birefringence variations related to nerve activity is a promising label-free technique for sensing compound neural action potentials (CNAPs). While widely applied in crustaceans, little is known about its efficiency on mammal peripheral nerves. In this work, birefringence recordings to detect CNAPs, and Stokes parameters measurements were performed in rat and lobster nerves. While single-trial detection of nerve activity in crustaceans was achieved successfully, no optical signal was detected in rats, even after extensive signal filtering and averaging. The Stokes parameters showed that a high degree of polarization of light is maintained in lobster sample, whereas an almost complete light depolarization occurs in rat nerve. Our results indicate that depolarization itself is not sufficient to explain the absence of birefringence signals in rats. We hypothesize that this absence comes from the myelin sheets, which constraint the birefringence changes to only take place at the nodes of Ranvier.


Assuntos
Bainha de Mielina , Nervos Periféricos , Potenciais de Ação/fisiologia , Animais , Birrefringência , Potenciais Evocados , Mamíferos , Nervos Periféricos/fisiologia , Ratos
14.
J Neural Eng ; 19(4)2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35764074

RESUMO

Objective.The vagus nerve is considered to play a key role in the circadian rhythm. Chronic continuous analysis of the vagus nerve activity could contribute to a better understanding of the role of the vagus nerve in light-dark modulations. This paper presents a continuous analysis of spontaneous vagus nerve activity performed in four rats.Approach.We analyzed the vagus electroneurogram (VENG) and electroencephalogram (EEG) over a recording period of 28 d. Spike activity and heart rate estimation were derived from the VENG, and slow-wave activity was derived from the EEG. The presence of repetitive patterns was investigated with periodograms, cosinor fitting, autocorrelation, and statistical tests. The light-dark variations derived from the VENG spikes were compared with EEG slow waves, an established metric in circadian studies.Results.Our results demonstrate that light-dark variations can be detected in long-term vagus nerve activity monitoring. A recording period of about 7 d is required to characterize accurately the VENG light-dark variations.Significance.As a major outcome of this study, vagus nerve recordings hold the promise to help understand circadian regulation.


Assuntos
Fotoperíodo , Estimulação do Nervo Vago , Animais , Ritmo Circadiano/fisiologia , Eletroencefalografia/métodos , Ratos , Nervo Vago/fisiologia
16.
Cell Death Discov ; 8(1): 66, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35169122

RESUMO

Cold atmospheric plasma (CAP) treatment has been proposed as a potentially innovative therapeutic tool in the biomedical field, notably for cancer due to its proposed toxic selectivity on cancer cells versus healthy cells. In the present study, we addressed the relevance of three-dimensional organoid technology to investigate the biological effects of CAP on normal epithelial stem cells and tumor cells isolated from mouse small intestine. CAP treatment exerted dose-dependent cytotoxicity on normal organoids and induced major transcriptomic changes associated with the global response to oxidative stress, fetal-like regeneration reprogramming, and apoptosis-mediated cell death. Moreover, we explored the potential selectivity of CAP on tumor-like Apc-deficient versus normal organoids in the same genetic background. Unexpectedly, tumor organoids exhibited higher resistance to CAP treatment, correlating with higher antioxidant activity at baseline as compared to normal organoids. This pilot study suggests that the ex vivo culture system could be a relevant alternative model to further investigate translational medical applications of CAP technology.

17.
Artif Organs ; 46(6): 1055-1067, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34932224

RESUMO

BACKGROUND: Gastric electrical stimulation (GES) has been studied for decades as a promising treatment for obesity. Stimulation pulses with fixed amplitude and pulse width are usually applied, but these have limitations with regard to overcoming habituation to GES and inter-subject variation. This study aims to analyze the efficacy of an adaptive GES protocol for reducing food intake and maintaining lean weight in dogs. METHODS: Six beagle dogs were implanted with a remotely programmable gastric stimulator. An adaptive protocol was designed to increase the stimulation energy proportionally to the excess of food consumption, with respect to the dogs' maintenance energy requirements. After surgery and habituation to experimental conditions, the dogs went through both a control and a stimulation period of 4 weeks each, in a randomized order. The stimulation parameters were adapted daily. Body weight, food intake, food intake rate, and postprandial cutaneous electrogastrograms (EGG) were recorded to assess the effect of adaptive GES. RESULTS: Adaptive GES decreased food intake and food intake rate (p < 0.05) resulting in weight maintenance. In the absence of GES, the dogs gained weight (p < 0.05). Postprandial EGG dominant frequency was accelerated by GES (p < 0.05). The strategy of adapting the stimulation energy was effective in causing significant mid-term changes. CONCLUSION: Adaptive GES is effective for reducing food intake and maintaining lean weight. The proposed adaptive strategy may offer benefits to counter habituation and adapt to inter-subject variation in clinical use of GES for obesity.


Assuntos
Ingestão de Alimentos , Terapia por Estimulação Elétrica , Animais , Cães , Ingestão de Alimentos/fisiologia , Estimulação Elétrica , Terapia por Estimulação Elétrica/métodos , Obesidade/terapia , Estômago
18.
Front Physiol ; 12: 734311, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34955874

RESUMO

Cardiac mechanical activity leads to periodic changes in the distribution of blood throughout the body, which causes micro-oscillations of the body's center of mass and can be measured by ballistocardiography (BCG). However, many of the BCG findings are based on parameters whose origins are poorly understood. Here, we generate simulated multidimensional BCG signals based on a more exhaustive and accurate computational model of blood circulation than previous attempts. This model consists in a closed loop 0D-1D multiscale representation of the human blood circulation. The 0D elements include the cardiac chambers, cardiac valves, arterioles, capillaries, venules, and veins, while the 1D elements include 55 systemic and 57 pulmonary arteries. The simulated multidimensional BCG signal is computed based on the distribution of blood in the different compartments and their anatomical position given by whole-body magnetic resonance angiography on a healthy young subject. We use this model to analyze the elements affecting the BCG signal on its different axes, allowing a better interpretation of clinical records. We also evaluate the impact of filtering and healthy aging on the BCG signal. The results offer a better view of the physiological meaning of BCG, as compared to previous models considering mainly the contribution of the aorta and focusing on longitudinal acceleration BCG. The shape of experimental BCG signals can be reproduced, and their amplitudes are in the range of experimental records. The contributions of the cardiac chambers and the pulmonary circulation are non-negligible, especially on the lateral and transversal components of the velocity BCG signal. The shapes and amplitudes of the BCG waveforms are changing with age, and we propose a scaling law to estimate the pulse wave velocity based on the time intervals between the peaks of the acceleration BCG signal. We also suggest new formulas to estimate the stroke volume and its changes based on the BCG signal expressed in terms of acceleration and kinetic energy.

19.
Neurotherapeutics ; 18(4): 2623-2638, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34668148

RESUMO

Neural desynchronization was shown as a key mechanism of vagus nerve stimulation (VNS) action in epilepsy, and EEG synchronization measures are explored as possible response biomarkers. Since brain functional organization in sleep shows different synchrony and network properties compared to wakefulness, we aimed to explore the effects of acute VNS on EEG-derived measures in the two different states of vigilance. EEG epochs were retrospectively analyzed from twenty-four VNS-treated epileptic patients (11 responders, 13 non-responders) in calm wakefulness and stage N2 sleep. Weighted Phase Lag Index (wPLI) was computed as connectivity measure of synchronization, for VNS OFF and VNS ON conditions. Global efficiency (GE) was computed as a network measure of integration. Ratios OFF/ON were obtained as desynchronization/de-integration index. Values were compared between responders and non-responders, and between EEG states. ROC curve and area-under-the-curve (AUC) analysis was performed for response classification. In responders, stronger VNS-induced theta desynchronization (p < 0.05) and decreased GE (p < 0.05) were found in sleep, but not in wakefulness. Theta sleep wPLI Ratio OFF/ON yielded an AUC of 0.825, and 79% accuracy as a response biomarker if a cut-off value is set at 1.05. Considering all patients, the VNS-induced GE decrease was significantly more important in sleep compared to awake EEG state (p < 0.01). In conclusion, stronger sleep EEG desynchronization in theta band distinguishes responders to VNS therapy from non-responders. VNS-induced reduction of network integration occurs significantly more in sleep than in wakefulness.


Assuntos
Epilepsia , Estimulação do Nervo Vago , Eletroencefalografia , Epilepsia/terapia , Humanos , Estudos Retrospectivos , Sono , Nervo Vago
20.
Med Eng Phys ; 92: 93-101, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34167717

RESUMO

A novel electrode anchoring design and its implantation procedure, aiming for a minimally invasive solution for gastric electrical stimulation, are presented. The system comprises an anchor made of a flexible body embedding two needle-shaped electrodes. The electrodes can easily switch from a parallel position - to pierce the stomach - to a diverging position - enabling them to remain firmly anchored into the muscular layer of the stomach. Key device parameters governing anchoring stability were assessed on a traction test bench, and optimal values were derived. The device was then implanted in six dogs by open surgery to assess its anchoring durability in vivo. Computed tomography images showed that the electrodes remained well placed within the dogs' gastric wall over the entire assessment period (more than one year). Finally, a prototype of a surgical tool for the minimally invasive device placement was manufactured, and the anchoring procedure was tested on a dog cadaver, providing the proof of concept of the minimally invasive implantation procedure. The use of our electrode anchoring system in long-term gastric electrical stimulation is promising in terms of implantation stability (the anchor withstands a force up to 0.81 N), durability (the anchor remains onto the stomach over one year) and minimal invasiveness of the procedure (the diameter of the percutaneous access is smaller than 12 mm). Moreover, the proposed design could have clinical applications in other hollow organs, such as the urinary bladder.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos , Estômago , Animais , Cadáver , Cães , Eletrodos Implantados , Estômago/diagnóstico por imagem , Estômago/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...