Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Geriatr Cardiol ; 21(3): 323-330, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38665288

RESUMO

BACKGROUND: Smartwatches have become readily accessible tools for detecting atrial fibrillation (AF). There remains limited data on how they affect psychosocial outcomes and engagement in older adults. We examine the health behavior outcomes of stroke survivors prescribed smartwatches for AF detection stratified by age. METHODS: We analyzed data from the Pulsewatch study, a randomized controlled trial that enrolled patients (≥ 50 years) with a history of stroke or transient ischemic attack and CHA2DS2-VASc ≥ 2. Intervention participants were equipped with a cardiac patch monitor and a smartwatch-app dyad, while control participants wore the cardiac patch monitor for up to 44 days. We evaluated health behavior parameters using standardized tools, including the Consumer Health Activation Index, the Generalized Anxiety Disorder questionnaire, the 12-Item Short Form Health Survey, and wear time of participants categorized into three age groups: Group 1 (ages 50-60), Group 2 (ages 61-69), and Group 3 (ages 70-87). We performed statistical analysis using a mixed-effects repeated measures linear regression model to examine differences amongst age groups. RESULTS: Comparative analysis between Groups 1, 2 and 3 revealed no significant differences in anxiety, patient activation, perception of physical health and wear time. The use of smartwatch technology was associated with a decrease in perception of mental health for Group 2 compared to Group 1 (ß = -3.29, P = 0.046). CONCLUSION: Stroke survivors demonstrated a willingness to use smartwatches for AF monitoring. Importantly, among these study participants, the majority did not experience negative health behavior outcomes or decreased engagement as age increased.

2.
IEEE Trans Biomed Eng ; 71(2): 456-466, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37682653

RESUMO

OBJECTIVE: We propose an efficient approach based on a convolutional denoising autoencoder (CDA) network to reduce motion and noise artifacts (MNA) from corrupted atrial fibrillation (AF) and non-AF photoplethysmography (PPG) data segments so that an accurate PPG-signal-derived heart rate can be obtained. Our method's main innovation is the optimization of the CDA performance for both rhythms using more AF than non-AF data for training the AF-specific CDA model and vice versa for the non-AF CDA network. METHODS: To evaluate this unconventional training scheme, our proposed network was trained and tested on 25-sec PPG data segments from 48 subjects from two different databases-the Pulsewatch dataset and Stanford University's publicly available PPG dataset. In total, our dataset contains 10,773 data segments: 7,001 segments for training and 3,772 independent segments from out-of-sample subjects for testing. RESULTS: Using real-life corrupted PPG segments, our approach significantly reduced the average heart rate root mean square error (RMSE) of the reconstructed PPG segments by 45.74% and 23% compared to the corrupted non-AF and AF data, respectively. Further, our approach exhibited lower RMSE, and higher sensitivity and PPV for detected peaks compared to the reconstructed data produced by the alternative methods. CONCLUSION: These results show the promise of our approach as a reliable denoising method, which should be used prior to AF detection algorithms for an accurate cardiac health monitoring involving wearable devices. SIGNIFICANCE: PPG signals collected from wearables are vulnerable to MNA, which limits their use as a reliable measurement, particularly in uncontrolled real-life environments.


Assuntos
Fibrilação Atrial , Fotopletismografia , Humanos , Fotopletismografia/métodos , Fibrilação Atrial/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Movimento (Física) , Algoritmos , Processamento de Sinais Assistido por Computador , Artefatos
3.
Front Digit Health ; 5: 1243959, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125757

RESUMO

Background: Increasing ownership of smartphones among Americans provides an opportunity to use these technologies to manage medical conditions. We examine the influence of baseline smartwatch ownership on changes in self-reported anxiety, patient engagement, and health-related quality of life when prescribed smartwatch for AF detection. Method: We performed a post-hoc secondary analysis of the Pulsewatch study (NCT03761394), a clinical trial in which 120 participants were randomized to receive a smartwatch-smartphone app dyad and ECG patch monitor compared to an ECG patch monitor alone to establish the accuracy of the smartwatch-smartphone app dyad for detection of AF. At baseline, 14 days, and 44 days, participants completed the Generalized Anxiety Disorder-7 survey, the Health Survey SF-12, and the Consumer Health Activation Index. Mixed-effects linear regression models using repeated measures with anxiety, patient activation, physical and mental health status as outcomes were used to examine their association with smartwatch ownership at baseline. Results: Ninety-six participants, primarily White with high income and tertiary education, were randomized to receive a study smartwatch-smartphone dyad. Twenty-four (25%) participants previously owned a smartwatch. Compared to those who did not previously own a smartwatch, smartwatch owners reported significant greater increase in their self-reported physical health (ß = 5.07, P < 0.05), no differences in anxiety (ß = 0.92, P = 0.33), mental health (ß = -2.42, P = 0.16), or patient activation (ß = 1.86, P = 0.54). Conclusions: Participants who own a smartwatch at baseline reported a greater positive change in self-reported physical health, but not in anxiety, patient activation, or self-reported mental health over the study period.

4.
JMIR Cardio ; 7: e45137, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38015598

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. OBJECTIVE: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. METHODS: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. RESULTS: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. CONCLUSIONS: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. TRIAL REGISTRATION: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1016/j.cvdhj.2021.07.002.

5.
Cardiovasc Digit Health J ; 4(4): 118-125, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37600446

RESUMO

Background: The detection of atrial fibrillation (AF) in stroke survivors is critical to decreasing the risk of recurrent stroke. Smartwatches have emerged as a convenient and accurate means of AF diagnosis; however, the impact on critical patient-reported outcomes, including anxiety, engagement, and quality of life, remains ill defined. Objectives: To examine the association between smartwatch prescription for AF detection and the patient-reported outcomes of anxiety, patient activation, and self-reported health. Methods: We used data from the Pulsewatch trial, a 2-phase randomized controlled trial that included participants aged 50 years or older with a history of ischemic stroke. Participants were randomized to use either a proprietary smartphone-smartwatch app for 30 days of AF monitoring or no cardiac rhythm monitoring. Validated surveys were deployed before and after the 30-day study period to assess anxiety, patient activation, and self-rated physical and mental health. Logistic regression and generalized estimation equations were used to examine the association between smartwatch prescription for AF monitoring and changes in the patient-reported outcomes. Results: A total of 110 participants (mean age 64 years, 41% female, 91% non-Hispanic White) were studied. Seventy percent of intervention participants were novice smartwatch users, as opposed to 84% of controls, and there was no significant difference in baseline rates of anxiety, activation, or self-rated health between the 2 groups. The incidence of new AF among smartwatch users was 6%. Participants who were prescribed smartwatches did not have a statistically significant change in anxiety, activation, or self-reported health as compared to those who were not prescribed smartwatches. The results held even after removing participants who received an AF alert on the watch. Conclusion: The prescription of smartwatches to stroke survivors for AF monitoring does not adversely affect key patient-reported outcomes. Further research is needed to better inform the successful deployment of smartwatches in clinical practice.

6.
Cardiol Cardiovasc Med ; 7(2): 97-107, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476150

RESUMO

Wrist-based wearables have been FDA approved for AF detection. However, the health behavior impact of false AF alerts from wearables on older patients at high risk for AF are not known. In this work, we analyzed data from the Pulsewatch (NCT03761394) study, which randomized patients (≥50 years) with history of stroke or transient ischemic attack to wear a patch monitor and a smartwatch linked to a smartphone running the Pulsewatch application vs to only the cardiac patch monitor over 14 days. At baseline and 14 days, participants completed validated instruments to assess for anxiety, patient activation, perceived mental and physical health, chronic symptom management self-efficacy, and medicine adherence. We employed linear regression to examine associations between false AF alerts with change in patient-reported outcomes. Receipt of false AF alerts was related to a dose-dependent decline in self-perceived physical health and levels of disease self-management. We developed a novel convolutional denoising autoencoder (CDA) to remove motion and noise artifacts in photoplethysmography (PPG) segments to optimize AF detection, which substantially reduced the number of false alerts. A promising approach to avoid negative impact of false alerts is to employ artificial intelligence driven algorithms to improve accuracy.

8.
JMIR Form Res ; 6(6): e38113, 2022 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-35649180

RESUMO

BACKGROUND: Serial testing for SARS-CoV-2 is recommended to reduce spread of the virus; however, little is known about adherence to recommended testing schedules and reporting practices to health departments. OBJECTIVE: The Self-Testing for Our Protection from COVID-19 (STOP COVID-19) study aims to examine adherence to a risk-based COVID-19 testing strategy using rapid antigen tests and reporting of test results to health departments. METHODS: STOP COVID-19 is a 12-week digital study, facilitated using a smartphone app for testing assistance and reporting. We are recruiting 20,000 participants throughout the United States. Participants are stratified into high- and low-risk groups based on history of COVID-19 infection and vaccination status. High-risk participants are instructed to perform twice-weekly testing for COVID-19 using rapid antigen tests, while low-risk participants test only in the case of symptoms or exposure to COVID-19. All participants complete COVID-19 surveillance surveys, and rapid antigen results are recorded within the smartphone app. Primary outcomes include participant adherence to a risk-based serial testing protocol and percentage of rapid tests reported to health departments. RESULTS: As of February 2022, 3496 participants have enrolled, including 1083 high-risk participants. Out of 13,730 tests completed, participants have reported 13,480 (98.18%, 95% CI 97.9%-98.4%) results to state public health departments with full personal identifying information or anonymously. Among 622 high-risk participants who finished the study period, 35.9% showed high adherence to the study testing protocol. Participants with high adherence reported a higher percentage of test results to the state health department with full identifying information than those in the moderate- or low-adherence groups (high: 71.7%, 95% CI 70.3%-73.1%; moderate: 68.3%, 95% CI 66.0%-70.5%; low: 63.1%, 59.5%-66.6%). CONCLUSIONS: Preliminary results from the STOP COVID-19 study provide important insights into rapid antigen test reporting and usage, and can thus inform the use of rapid testing interventions for COVID-19 surveillance.

9.
Cardiovasc Digit Health J ; 3(3): 126-135, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35720675

RESUMO

Background: Smartwatches can be used for atrial fibrillation (AF) detection, but little is known about how older adults at risk for AF perceive their usability. Methods: We employed a mixed-methods study design using data from the ongoing Pulsewatch study, a randomized clinical trial (NCT03761394) examining the accuracy of a smartwatch-smartphone app dyad (Samsung/Android) compared to usual care with a patch monitor (Cardea SOLO™ ECG System) for detection of AF among older stroke survivors. To be eligible to participate in Pulsewatch, participants needed to be at least 50 years of age, have had an ischemic stroke, and have no major contraindications to anticoagulation therapy should AF be detected. After 14 days of use, usability was measured by the System Usability Scale (SUS) and investigator-generated questions. Qualitative interviews were conducted, transcribed, and coded via thematic analysis. Results: Ninety participants in the Pulsewatch trial were randomized to use a smartwatch-smartphone app dyad for 14 days (average age: 65 years, 41% female, 87% White), and 46% found it to be highly usable (SUS ≥68). In quantitative surveys, participants who used an assistive device (eg, wheelchair) and those with history of anxiety or depression were more likely to report anxiety associated with watch use. In qualitative interviews, study participants reported wanting a streamlined system that was more focused on rhythm monitoring and a smartwatch with a longer battery life. In-person training and support greatly improved their experience, and participants overwhelmingly preferred use of a smartwatch over traditional cardiac monitoring owing to its comfort, appearance, and convenience. Conclusion: Older adults at high risk for AF who were randomized to use a smartwatch-app dyad for AF monitoring over 14 days found it to be usable for AF detection and preferred their use to the use of a patch monitor. However, participants reported that a simpler device interface and longer smartwatch battery life would increase the system's usability.

10.
IEEE Trans Biomed Eng ; 69(9): 2982-2993, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35275809

RESUMO

OBJECTIVE: With the increasing use of wearable healthcare devices for remote patient monitoring, reliable signal quality assessment (SQA) is required to ensure the high accuracy of interpretation and diagnosis on the recorded data from patients. Photoplethysmographic (PPG) signals non-invasively measured by wearable devices are extensively used to provide information about the cardiovascular system and its associated diseases. In this study, we propose an approach to optimize the quality assessment of the PPG signals. METHODS: We used an ensemble-based feature selection scheme to enhance the prediction performance of the classification model to assess the quality of the PPG signals. Our approach for feature and subset size selection yielded the best-suited feature subset, which was optimized to differentiate between the clean and artifact corrupted PPG segments. CONCLUSION: A high discriminatory power was achieved between two classes on the test data by the proposed feature selection approach, which led to strong performance on all dependent and independent test datasets. We achieved accuracy, sensitivity, and specificity rates of higher than 0.93, 0.89, and 0.97, respectively, for dependent test datasets, independent of heartbeat type, i.e., atrial fibrillation (AF) or non-AF data including normal sinus rhythm (NSR), premature atrial contraction (PAC), and premature ventricular contraction (PVC). For independent test datasets, accuracy, sensitivity, and specificity rates were greater than 0.93, 0.89, and 0.97, respectively, on PPG data recorded from AF and non-AF subjects. These results were found to be more accurate than those of all of the contemporary methods cited in this work. SIGNIFICANCE: As the results illustrate, the advantage of our proposed scheme is its robustness against dynamic variations in the PPG signal during long-term 14-day recordings accompanied with different types of physical activities and a diverse range of fluctuations and waveforms caused by different individual hemodynamic characteristics, and various types of recording devices. This robustness instills confidence in the application of the algorithm to various kinds of wearable devices as a reliable PPG signal quality assessment approach.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Algoritmos , Artefatos , Eletrocardiografia/métodos , Frequência Cardíaca , Humanos , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...