Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mol Ther Methods Clin Dev ; 30: 394-402, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37637382

RESUMO

Recombinant adeno-associated virus (rAAV) vectors have displayed enormous potential as a platform for delivery of gene therapies. Purification of rAAV at industrial scale involves a series of elaborate, material, and time-consuming midstream steps, such as clarification by depth filtration and concentration/buffer exchange by tangential flow filtration. In this study, we developed a filter-less flow capture method for purification of rAAV serotype 5, using a high-gradient magnetic separator and magnetic Mag Sepharose beads coupled to an AVB affinity ligand. In under 2 h, we captured and eluted rAAV5 directly from ∼5 L of cell lysate with a recovery yield of 63% (±5%, n = 3). Compared to cell lysate, the eluate showed a 3-log reduction of host cell DNA and host cell proteins. The process developed eliminates the need for filtration and column chromatography in the early steps of industrial rAAV purification. This will be of high value for industrial-scale manufacturing of rAAVs by reducing time and material in the purification process, without compromising product recovery and purity.

2.
N Biotechnol ; 42: 48-55, 2018 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-29474833

RESUMO

Monoclonal antibodies are a dominant component of today's biopharmaceutical market and are typically purified by classical platform processes. However, high costs and rising demands are drivers for the development of new, efficient and flexible integrated purification processes. Currently, high-gradient magnetic separation as a direct capturing tool for protein purification suffers from the lack of suitable GMP-compliant separation equipment for industrial scale. As a solution for this bottleneck, we present a purification process for a monoclonal antibody directly from CHO cell culture by use of protein A-functionalized magnetic particles together with the first pilot-scale GMP-compliant 'rotor-stator' high-gradient magnetic separator. Five consecutive purification cycles were performed, achieving consistent yields of over 85% and purities of over 95%. Stable cell viabilities during the magnetic separation process enable integration of the device as an in situ product removal tool. A comparison with state-of-the-art protein A column-based purification processes reveals a 3-times higher process productivity per mL of applied resin and demonstrates the great potential of magnetic separation in downstream processing.


Assuntos
Anticorpos Monoclonais Murinos/isolamento & purificação , Campos Magnéticos , Sefarose/química , Proteína Estafilocócica A/química , Animais , Células CHO , Cricetulus
3.
J Chromatogr A ; 1418: 103-109, 2015 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-26431859

RESUMO

Therapeutic monoclonal antibodies represent one of the fastest growing segments in the pharmaceutical market. The growth of the segment has necessitated development of new efficient and cost saving platforms for the preparation and analysis of early candidates for faster and better antibody selection and characterization. We report on a new integrated platform for automated harvesting of whole unclarified cell-culture broths, followed by in-line tandem affinity-capture, pH neutralization and size-exclusion chromatography of recombinant antibodies expressed transiently in mammalian human embryonic kidney 293T-cells at the 1-L scale. The system consists of two bench-top chromatography instruments connected to a central unit with eight disposable filtration devices used for loading and filtering the cell cultures. The staggered parallel multi-step configuration of the system allows unattended processing of eight samples in less than 24h. The system was validated with a random panel of 45 whole-cell culture broths containing recombinant antibodies in the early profiling phase. The results showed that the overall performances of the preparative automated system were higher compared to the conventional downstream process including manual harvesting and purification. The mean recovery of purified material from the culture-broth was 66.7%, representing a 20% increase compared to that of the manual process. Moreover, the automated process reduced by 3-fold the amount of residual aggregates in the purified antibody fractions, indicating that the automated system allows the cost-efficient and timely preparation of antibodies in the 20-200mg range, and covers the requirements for early in vitro and in vivo profiling and formulation of these drug candidates.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Animais , Técnicas de Cultura de Células/métodos , Cromatografia em Gel , Meios de Cultura/química , Filtração/instrumentação , Células HEK293 , Humanos
4.
Protein Sci ; 13(6): 1476-88, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15152083

RESUMO

Antibodies of type IgG may be divided into two classes, called lambda or kappa, depending on the type of light chain. We have identified a conserved pocket between the two domains CH1 and CL of human IgG kappa-Fab, which is not present in the lambda type. This pocket was used as a target docking site with the purpose of exploring the possibilities of designing affinity ligands that could function as such even after immobilization to gel. The idea of the design arose mainly from the results of the saturated transfer difference (STD-NMR) screening of 46 compounds identified by means of virtual docking of 60 K diverse compounds from the Available Chemicals Directory (ACD). Surface plasmon resonance (SPR) was used as an alternative method to monitor binding in solution. A total of 24 compounds belonging to a directed library were designed, synthesized, and screened in solution. They consist essentially of an amino acid condensed to a N,N'-methylated phenyl urea. STD-NMR results suggest that a small hydrophobic side chain in the condensed amino acid promotes binding, whereas a hydroxyl-group-containing side chain implies absence of STD-NMR signals. Three compounds of the directed library were immobilized and evaluated as chromatographic probes. In one case, using D-Pro as the condensed amino acid, columns packed with ligand-coupled Sepharose (Amersham Biosciences) retained two different monoclonal samples of kappa-Fab fragments with different variable regions, whereas a sample of monoclonal lambda-Fab fragments was not retained under similar chromatographic conditions.


Assuntos
Sequência Conservada , Desenho de Fármacos , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/metabolismo , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Sítios de Ligação , Humanos , Ligantes , Modelos Moleculares , Estrutura Molecular , Ressonância Magnética Nuclear Biomolecular , Biblioteca de Peptídeos , Ligação Proteica , Ressonância de Plasmônio de Superfície
5.
J Chromatogr A ; 1016(1): 21-33, 2003 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-14601825

RESUMO

Several prototypes of multi-modal ligands suitable for the capture of negatively charged proteins from high conductivity (28 mS/cm) mobile phases were coupled to Sepharose 6 Fast Flow. These new prototypes of multi-modal anion-exchangers were found by screening a diverse library of multi-modal ligands and selecting anion-exchangers resulting in elution of test proteins at high ionic strength. Candidates were then tested with respect to breakthrough capacity of BSA in a buffer adjusted to a high conductivity (20 mM Piperazine and 0.25 M NaCl, pH 6.0). The recovery of BSA was also tested with a salt step (from 0.25 to 2.0 M NaCl using 20 mM Piperazine as buffer, pH 6.0) or with a pH-step to pH 4.0. We have found that non-aromatic multi-modal anion-exchange ligands based on primary or secondary amines (or both) are optimal for the capture of proteins at high salt conditions. Furthermore, these new multi-modal anion-exchange ligands have been designed to take advantage not only of electrostatic but also hydrogen bond interactions. This has been accomplished through modification of the ligands by the introduction of hydroxyl groups in the proximity of the ionic group. Experimental evidence on the importance of the relative position of the hydroxyl groups on the ligand in order to improve the breakthrough capacity of BSA has been found. Compared to strong anion-exchangers such as Q Sepharose Fast Flow the new multi-modal weak anion-exchangers have breakthrough capacities of BSA at mobile phases of 28 mS/cm and pH 6.0 that are 20-30 times higher. The new multi-modal anion-exchangers can also be used at normal anion-exchange conditions and with either a salt step or a pH-step to acidic pH can accomplish the elution of proteins. In addition, the functional performance of the new anion-exchangers was found to be intact after treatment in 1.0 M sodium hydroxide solution for 1 week. A number of multi-modal anion-exchange ligands based on aromatic amines exhibiting high breakthrough capacity of BSA have been found. With these ligands recovery was often found to be low due to strong non-electrostatic interactions. However, for phenol derived anion-exchange media the recovery can be improved by desorption at high pH.


Assuntos
Soroalbumina Bovina/isolamento & purificação , Resinas de Troca Aniônica , Cromatografia por Troca Iônica/métodos , Ligação de Hidrogênio , Concentração de Íons de Hidrogênio , Concentração Osmolar , Soroalbumina Bovina/química , Hidróxido de Sódio/química
6.
J Chromatogr A ; 1016(1): 35-49, 2003 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-14601826

RESUMO

Several prototypes of aromatic (Ar) and non-aromatic (NoAr) cation-exchange ligands suitable for capture of proteins from high conductivity (ca. 30 mS/cm) mobile phases were coupled to Sepharose 6 Fast Flow. These new prototypes of multi-modal cation-exchangers were found by screening a diverse library of multi-modal ligands and selecting cation-exchangers resulting in elution of test proteins at high ionic-strength. Candidates were then tested with respect to breakthrough capacity of bovine serum albumin (BSA), human IgG and lysozyme in buffers adjusted to a high conductivity. By applying a salt-step or a pH-step the recoveries were also tested. We have found that aromatic multi-modal cation-exchanger ligands based on carboxylic acids seem to be optimal for the capture of proteins at high-salt conditions. Experimental evidence on the importance of the relative position of the aromatic group in order to improve the breakthrough capacity at high-salt conditions has been found. It was also found that an amide group on the alpha-carbon was essential for capture of proteins at high-salt conditions. Compared to a strong cation-exchanger such as SP Sepharose Fast Flow the best new multi-modal weak cation-exchangers have breakthrough capacities of BSA, human IgG and lysozyme that are 10-30 times higher at high-salt conditions. The new multi-modal cation-exchangers can also be used at normal cation-exchange conditions and with either a salt-step or a pH-step (to pH-values where the proteins are negatively charged) to accomplish elution of proteins. In addition, the functional performance of the new cation-exchangers was found to be intact after treatment in 1.0 M sodium hydroxide solution for 10 days. For BSA it was also possible to design cation-exchangers based on non-aromatic carboxyl acid ligands with high capacities at high-salt conditions. A common feature of these ligands is that they contain hydrogen acceptor groups close to the carboxylic group. Furthermore, it was also possible to obtain high breakthrough capacities for lysozyme and BSA of a strong cation-exchanger (SP Sepharose Fast Flow) if phenyl groups were attached to the beads. Varying the ligand ratio (SP/Phenyl) could be used for optimizing the function of mixed-ligand ion-exchange media.


Assuntos
Proteínas/isolamento & purificação , Cloreto de Sódio/química , Resinas de Troca de Cátion , Cromatografia por Troca Iônica/métodos , Concentração de Íons de Hidrogênio , Concentração Osmolar , Proteínas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA