Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sex Transm Infect ; 99(6): 409-415, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37156608

RESUMO

INTRODUCTION: Polyphenylene carboxymethylene (PPCM) is a condensation polymer that has both contraceptive and antimicrobial activity against several sexually transmitted viruses including HIV, herpes simplex virus, Ebola virus and SARS-CoV-2 in preclinical studies. PPCM, both as an active pharmaceutical ingredient (API) and in a vaginal gel formulation (Yaso-GEL), has an excellent safety profile. Here, we evaluated the efficacy of PPCM against Neisseria gonorrhoeae in vitro and in a gonorrhoea mouse model. METHODS: The minimal inhibitory concentration (MIC) of PPCM was determined against 11 N. gonorrhoeae strains by agar dilution and a microtitre plate-based method. In vivo efficacy was tested in a murine model of N. gonorrhoeae genital tract infection by applying Yaso-GEL, PPCM incorporated in 2.7% hydroxyethylcellulose (HEC), or the HEC vehicle vaginally prior to challenge with N. gonorrhoeae. Vaginal swabs were quantitatively cultured over 5 days to assess efficacy. RESULTS: PPCM MIC against N. gonorrhoeae ranged between 5-100 µg/mL (agar dilution) and 50-200 µg/mL (microtitre plate method). PPCM/HEC gel applied vaginally prior to bacterial challenge resulted in a concentration-dependent inhibition of infection. Yaso-GEL containing 4% PPCM prevented infection in 100% of mice. Incubation of N. gonorrhoeae with PPCM increased membrane permeability, suggesting PPCM directly compromises N. gonorrhoeae viability, which may be a mechanism by which PPCM inhibits N. gonorrhoeae infection. CONCLUSIONS: Yaso-GEL containing the API PPCM showed significant activity against N. gonorrhoeae in vitro and in vivo in a female mouse model. These data support further development of Yaso-GEL as an inexpensive, non-hormonal and non-systemic product with both contraceptive and antimicrobial activity against gonorrhea and other common sexually transmitted infections (STIs). Such multipurpose prevention technology products are needed by women in all economic, social and cultural circumstances to prevent unintended pregnancy and STIs.


Assuntos
Gonorreia , Infecções Sexualmente Transmissíveis , Feminino , Humanos , Animais , Camundongos , Neisseria gonorrhoeae , Antibacterianos/uso terapêutico , Anticoncepcionais/uso terapêutico , Ágar/uso terapêutico , Gonorreia/tratamento farmacológico , Gonorreia/microbiologia , Polímeros/farmacologia , Polímeros/uso terapêutico , Testes de Sensibilidade Microbiana
2.
Andrology ; 10(2): 367-376, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34542939

RESUMO

BACKGROUND: Polyphenylene carboxymethylene (PPCM) sodium salt is a promising multipurpose technology for prevention of both sexually transmitted infections (STIs) and pregnancy. In preclinical studies, PPCM has demonstrated significant (1) antimicrobial activity against several important viral and bacterial pathogens and (2) contraceptive activity associated with premature acrosome loss. OBJECTIVE: To further evaluate a vaginal antimicrobial compound as a contraceptive agent in preclinical studies utilizing a repurposed hyaluronan binding assay (HBA). MATERIALS AND METHODS: Semen samples containing either neat semen or washed spermatozoa were treated with increasing concentrations of PPCM or calcium ionophore A23187 (positive control). Sperm inactivation was measured by two methods: (1) double acrosome staining (AS), and (2) a hyaluronan binding assay (HBA® ). Percentage of inactivated sperm was compared between untreated control sperm and those treated with PPCM or A23187. RESULTS: PPCM had a significant (p < 0.05) and dose-dependent effect on sperm inactivation in both assays, with HBA detecting a higher proportion of inactivated sperm than AS. PPCM did not affect sperm motility and exhibited equivalent responses in the neat and washed samples. DISCUSSION: Both HBA and AS confirmed that spermatozoa were rapidly inactivated at PPCM concentrations likely present in the vagina under actual use conditions and in a time-frame comparable to in vivo migration of spermatozoa out of seminal plasma into cervical mucus. CONCLUSION: PPCM vaginal gel may provide contraceptive protection as well as help with STI prevention. HBA may be a sensitive and much needed biomarker for sperm activity in future contraceptive development.


Assuntos
Acrossomo/efeitos dos fármacos , Anticoncepcionais/farmacologia , Polímeros/farmacologia , Espermatozoides/efeitos dos fármacos , Cremes, Espumas e Géis Vaginais/farmacologia , Calcimicina/farmacologia , Feminino , Humanos , Ácido Hialurônico , Masculino , Gravidez , Sêmen/efeitos dos fármacos , Motilidade dos Espermatozoides/efeitos dos fármacos
3.
J Womens Health (Larchmt) ; 20(2): 303-11, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21194348

RESUMO

BACKGROUND: Menstrual cups have been available for decades, but their use is limited by bulky design and the need for multiple sizes. The Softcup® (Instead, Inc., San Diego, CA) is a simple single-size disposable over-the-counter (OTC) menstrual cup that compresses to tampon shape to facilitate insertion and can be worn during coitus. This report describes preclinical evaluation, clinical testing, and postmarketing monitoring of the Softcup. METHODS: Preclinical testing complied with U.S. Food and Drug Administration (FDA) guidelines and used standard United States Pharmacopoeia methodologies for assessment of potential toxicity. Clinical testing enrolled 406 women in seven U.S. centers. A detailed written questionnaire assessed safety, acceptability, and effectiveness for menstrual collection. Study safety parameters included pelvic examinations, Pap smears, colposcopy, urinalysis, vaginal pH, wet mounts, gram stain, and vaginal microflora cultures. Postmarketing surveillance of over 100 million Softcups has been conducted by the manufacturer and by the FDA Medwatch system. RESULTS: No toxicity or mutagenicity was observed in preclinical evaluations. In clinical testing, after three cycles of cup use, 37% of subjects rated the cup as better than, 29% as worse than, and 34% as equal to pads or tampons. The cup was preferred for comfort, dryness, and less odor. Cups received lower ratings for disposal and convenience. Eighty-one percent of enrolled women were able to insert and remove their first cup using only written instructions. Use difficulties resulting in study discontinuations included cramping (1%), leakage (1%), and improper fit (3%). No safety parameters were adversely affected. No significant health risks were reported during postmarketing surveillance. CONCLUSIONS: These results demonstrate that a single-size vaginal device has no significant health risks and is acceptable to many women without the need for fitting or other medical services.


Assuntos
Líquidos Corporais/metabolismo , Ciclo Menstrual/fisiologia , Menstruação/fisiologia , Medicamentos sem Prescrição , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Vagina , Técnicas e Procedimentos Diagnósticos , Desenho de Equipamento , Feminino , Humanos , Estados Unidos , Útero/irrigação sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...