Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
2.
JAMA Cardiol ; 8(5): 475-483, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36947030

RESUMO

Importance: Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective: To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants: This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions: Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures: The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results: Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance: In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration: ClinicalTrials.gov Identifier: NCT02150902.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Veias Pulmonares/cirurgia , Eletrocardiografia Ambulatorial , Ablação por Cateter/efeitos adversos
3.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
4.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
5.
Front Neurol ; 13: 803312, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35432163

RESUMO

Objective: Spatial Neglect is prevalent among stroke survivors, yet few treatments have evidence supporting efficacy. This study examines the feasibility of Prism Adaptation Treatment (PAT) within an inpatient rehabilitation facility and the degree by which PAT improves symptoms of spatial neglect and functional independence among sub-acute survivors of right hemispheric stroke. Design: In this retrospective cohort study, 37 right hemispheric stroke patients were identified as having received at least 4 PAT sessions during their inpatient stay. Spatial neglect and functional independence levels of patients in the PAT cohort were compared to a matched active control group comprised of rehabilitation patients receiving alternative therapies to address neglect admitted during the same time period. Results: Most patients received the full recommended 10 sessions of PAT (average sessions completed = 8.6). A higher percentage of severe neglect patients receiving PAT (69%) displayed clinically significant gains on FIM (≥22 points) compared to those receiving alternative treatments (6%). Patients with mild or moderate neglect in the PAT cohort did not exhibit greater benefit than controls. Conclusion: Provision of PAT for treatment of spatial neglect in right hemispheric stroke patients was feasible during the inpatient rehabilitation admission. Patients with severe neglect showed the most benefit from PAT. Clinical Trial Registration: This study was registered as a retrospective observational study on Itab Clinical Trials.gov. NCT04977219.

6.
Am Heart J ; 248: 1-12, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35219715

RESUMO

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Canadá , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
8.
JAMA Cardiol ; 6(11): 1324-1328, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406350

RESUMO

Importance: Patients with atrial fibrillation (AF) have impaired health-related quality of life primarily owing to symptoms related to AF episodes; however, quality of life can be influenced by AF therapies, AF complications, the frequency of follow-up visits and hospitalizations, illness perceptions, and patient factors, such as anxiety or depression. Objective: To determine the association between change in AF burden and quality of life in the year following ablation. Design, Setting, and Participants: The current study is a secondary analysis of a prospective, parallel-group, multicenter, single-masked randomized clinical trial (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE] study), which took place at 8 Canadian centers. Between September 2014 and July 2017, 346 patients older than 18 years with symptomatic, primarily low-burden AF refractory to antiarrhythmic therapy referred for first catheter ablation were enrolled. All patients received an implantable cardiac monitor at least 30 days before ablation and were followed up with up to December 2018. Data were analyzed from April 2020 to June 2021. Interventions: Patients were randomized 1:1:1 to contact force-guided radiofrequency ablation, 4-minute cryoballoon ablation, or 2-minute cryoballoon ablation. The exposure in the present analysis is the absolute difference in AF burden prior to ablation and 12 months following ablation, as evaluated by the Atrial Fibrillation Effect on Quality of Life (AFEQT) Score. Main Outcomes and Measures: Absolute difference in quality of life from baseline to 12 months postablation. Results: Of 346 included patients, 231 (66.7%) were male, and the median (interquartile range) age was 60 (52-66) years. A total of 328 patients (94.8%) had paroxysmal AF. The median (interquartile range) preablation AF burden was 2.0% (0.1-11.9), and the AF burden decreased to 0% at 12 months postablation. At 12 months, a 1-point improvement in AFEQT score was observed for every absolute reduction in daily AF burden of 15.8 minutes (95% CI, 7.2-24.4; P < .001), or every 0.63% (95% CI, 0.30-0.95; P < .001) reduction in relative AF burden from baseline. Conclusions and Relevance: In patients with primarily low-burden paroxysmal AF, the reduction in AF burden following ablation may be associated with a clinically meaningful improvement in quality of life. Trial Registration: ClinicalTrials.gov Identifier: NCT01913522.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Eletrocardiografia , Qualidade de Vida , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/psicologia , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego
10.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
11.
JAMA Netw Open ; 3(12): e2025473, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33275151

RESUMO

Importance: Catheter ablation is effective in reducing atrial fibrillation (AF), but the association of ablation for AF with quality of life is unclear. Objective: To evaluate whether the procedural outcome of ablation for AF is associated with quality of life (QOL) measures. Design, Setting, and Participants: This was a prespecified secondary analysis of the Substrate and Trigger Ablation for Reduction of Atrial Fibrillation-Part II (STAR AF II) prospective randomized clinical trial, which compared 3 strategies for ablation of persistent AF. This analysis included 549 of the 589 patients enrolled in the trial who underwent ablation. Enrollment occurred at 35 centers in Europe, Canada, Australia, China, and Korea from November 2010 to July 2012. Data for the current study were analyzed on December 11, 2019. Interventions: Patients underwent AF ablation with 1 of 3 ablation strategies: (1) pulmonary vein isolation (PVI), (2) PVI plus complex fractionated electrograms, or (3) PVI plus linear lesions. Main Outcomes and Measures: Quality of life was assessed at baseline and at 6, 12, and 18 months after ablation for AF using the 36-Item Short Form Health Survey and the EuroQol Health-Related Quality of Life 5-Dimension 3-Level questionnaire. Scores were also converted to a physical health component score (PCS) and a mental health component score (MCS). Individual AF burden was calculated by the total time with AF from Holter monitors and the percentage of transtelephonic monitor recordings showing AF. Results: Among the 549 patients included in this secondary analysis, QOL was assessed in 466 (85%) at baseline and at 6, 12, and 18 months after ablation for AF. The mean (SD) age of the study population was 60 (9) years; 434 (79%) individuals were men, and 417 (76%) had continuous AF for 6 months or more before ablation. The AF burden significantly decreased from a mean (SD) of 82% (36%) before ablation to 6.6% (23%) after ablation (P < .001). Significant improvements in mean (SD) PCS (68.3 [20.7] to 82.5 [18.6]) and MCS (35.3 [8.6] to 37.5 [7.6]) occurred 18 months after ablation (P < .05 for both). Significant QOL improvement occurred in all 3 study arms and regardless of AF recurrence, defined as AF episodes lasting more than 30 seconds: for no recurrence, mean (SD) PCS increased from 66.5 (20.9) to 79.1 (19.4) and MCS from 35.3 (8.7) to 37.7 (7.7); for recurrence, mean (SD) PCS increased from 70.2 (20.4) to 86.4 (16.8) and MCS from 35.3 (8.6) to 37.1 (7.4) (P < .05 for all). When outcome was defined by AF burden reduction, in patients with less than 70% reduction in AF burden, the increase in PCS was significantly less than in those with greater than 70% reduction, and only 3 of 8 subscales showed significant improvement. Conclusions and Relevance: In this secondary analysis, decreases in AF burden after ablation for AF were significantly associated with improvements in QOL. Quality of life changes were significantly associated with the percentage of AF burden reduction after ablation. Trial Registration: ClinicalTrials.gov Identifier: NCT01203748.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Qualidade de Vida , Fibrilação Atrial/psicologia , Austrália/epidemiologia , Canadá/epidemiologia , Ablação por Cateter/métodos , Ablação por Cateter/psicologia , China/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Inquéritos Epidemiológicos , Humanos , Qualidade de Vida/psicologia , Ensaios Clínicos Controlados Aleatórios como Assunto , República da Coreia/epidemiologia , Resultado do Tratamento
12.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
14.
JACC Clin Electrophysiol ; 6(8): 935-944, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32819528

RESUMO

OBJECTIVES: This study evaluated the impact of contact force-guided radiofrequency ablation versus cryoballoon ablation on quality of life and health care utilization. BACKGROUND: Traditional outcome parameters, such as arrhythmia-free survival, are insufficient to evaluate the clinical impact of atrial fibrillation (AF), as it fails to the capture patient- and health system-level differences in treatment approaches. METHODS: The CIRCA-DOSE (Cryoballoon Vs. Contact-Force Atrial Fibrillation Ablation) study randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency or cryoballoon ablation. Health-related quality-of-life (HRQOL) was assessed at baseline, and at 6 and 12 months post-ablation using a disease-specific and generic HRQOL instruments. Health care utilization (hospitalization, emergency department visits, and cardioversion) and antiarrhythmic drug use for the 12 months preceding ablation was compared with the 12 months following ablation. RESULTS: Disease-specific and generic HRQOL was moderately to severely impaired at baseline and improved significantly at 6 and 12 months of follow-up (median improvement in AFEQT [Atrial Fibrillation Effect on QualiTy of Life] score 32.4 [interquartile range: 17.7 to 48.9]). When compared with the 12 months pre-ablation, the proportion and absolute number of cardioversions decreased significantly (41.1% vs. 10.1% of patients, 137 vs. 35 events; p < 0.0001). Similar significant reductions in emergency department visits (66.7% vs. 25.1% of patients, 224 vs. 87 events; p < 0.0001), and hospitalizations (25.5% vs. 14.5% of patients, 86 vs. 50 events; p < 0.001) were observed. There were no significant differences between randomized groups. CONCLUSIONS: In this multicenter randomized trial, catheter ablation with advanced-generation technologies resulted in a significant improvement in HRQOL and a significant reduction in health care utilization in the year following AF ablation. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE]; NCT01913522).


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Humanos , Aceitação pelo Paciente de Cuidados de Saúde , Qualidade de Vida , Resultado do Tratamento
15.
JAMA Netw Open ; 3(7): e208748, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32614422

RESUMO

Importance: Contemporary guidelines recommend that atrial fibrillation (AF) be classified based on episode duration, with these categories forming the basis of therapeutic recommendations. While pragmatic, these classifications are not based on pathophysiologic processes and may not reflect clinical outcomes. Objective: To evaluate the association of baseline AF episode duration with post-AF ablation arrhythmia outcomes. Design, Setting, and Participants: The current study is a secondary analysis of a prospective, parallel-group, multicenter, single-masked randomized clinical trial (the Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE] study), which took place at 8 Canadian centers. Between September 2014 and July 2017, 346 patients older than 18 years with symptomatic AF referred for first catheter ablation were enrolled. All patients received an implantable cardiac monitor at least 30 days before ablation. Data analysis was performed in September 2019. Exposure: Before ablation, patients were classified based on their longest AF episode. Ablation consisted of circumferential pulmonary vein isolation using standard techniques. Main Outcomes and Measures: Time to first recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) following ablation and AF burden (percentage of time in AF) on preablation and postablation continuous rhythm monitoring. Results: The study included 346 patients (mean [SD] age, 59 [10] years; 231 [67.7%] men). Overall, 263 patients (76.0%) had AF episode duration of less than 24 hours; 25 (7.2%), 24 to 48 hours; 40 (11.7%), 2 to 7 days; and 18 (5.2%), more than 7 days. Documented recurrence of any atrial tachyarrhythmia following ablation was significantly lower in patients with baseline AF episode duration of less than 24 continuous hours compared with those with longer AF episodes (24 hours vs 24-48 hours: hazard ratio [HR], 0.41; 95% CI, 0.21-0.80; P = .009; 24 hours vs 2-7 days: HR, 0.25; 95% CI, 0.14-0.45; P < .001; 24 hours vs >7 days: HR, 0.23; 95% CI, 0.09-0.55; P < .001). Patients with preablation AF episodes limited to less than 24 continuous hours had a significantly lower median (interquartile range) postablation AF burden (0% [0%-0.1%]) compared with those with AF preablation episodes lasting 2-7 days (0.1% [0%-1.0%]; P = .003) and those with AF preablation episodes lasting more than 7 days (1.0% [0%-5.4%]; P = .008). There was no significant difference in arrhythmia recurrence or AF burden between the 3 groups with a baseline AF episode duration of longer than 24 hours. Conclusions and Relevance: In this study, patients with AF episodes limited to less than 24 continuous hours had a significantly lower incidence of arrhythmia recurrence following AF ablation. This suggests that current guidelines for classification of AF may not reflect clinical outcomes. Trial Registration: ClinicalTrials.gov Identifier: NCT01913522.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Eletrocardiografia Ambulatorial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Canadá , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Interpretação Estatística de Dados , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Perioperatório/estatística & dados numéricos , Prognóstico , Recidiva , Fatores de Tempo , Resultado do Tratamento
17.
JACC Clin Electrophysiol ; 6(6): 609-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32553209

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy, health care utilization, and safety of a same-day discharge protocol. BACKGROUND: Catheter ablation of atrial fibrillation (AF) is the most common ablation performed. Increasing volumes of AF ablation are placing demands on hospital resources. In response, our institutions developed a same-day discharge protocol for AF ablation. METHODS: This was a multicenter cohort study of all patients undergoing AF ablation from 2010 to 2014 at 2 major centers. The primary efficacy outcome was the proportion of successful same-day discharges. The primary health care utilization outcome was 30-day hospital readmission for any reason. The primary safety outcome was a composite of 30-day death, stroke/transient ischemic attack or embolism, or bleeding requiring hospitalization. RESULTS: A total of 3,054 patients underwent AF ablation from 2010 to 2014 and met inclusion criteria. Same-day discharge was achieved in 79.2% (2,418 of 3,054). Hospital readmission at 30 days was 7.7% for the same-day discharge group, 10.2% for those who remained in the hospital overnight without complications (p = 0.055 for comparison with same-day discharge), and 19.5% (p < 0.001) for those who remained in the hospital with procedural complications (7.7%). Complication rates from discharge to 30 days (excluding immediate procedural complications) were 0.37% for the same-day discharge group, 0.36% (p = 0.999) for those kept overnight without complications, and 2.5% (p = 0.044) for those with initial procedural complications. CONCLUSIONS: Same-day discharge after AF ablation is feasible in the majority of patients with use of a standardized protocol. This approach was not associated with higher hospital readmission or complication rates after discharge.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Humanos , Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
18.
Heart Rhythm ; 17(11): 1841-1847, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32590151

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation to treat patients with symptomatic drug-refractory atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to assess the safety and efficacy of PVI using the cryoballoon catheter to treat patients with persistent AF. METHODS: STOP Persistent AF (ClinicalTrials.gov Identifier: NCT03012841) was a prospective, multicenter, single-arm, Food and Drug Administration-regulated trial designed to evaluate the safety and efficacy of PVI-only cryoballoon ablation for drug-refractory persistent AF (continuous episodes <6 months). The primary efficacy endpoint was 12-month freedom from ≥30 seconds of AF, atrial flutter (AFL), or atrial tachycardia (AT) after a 90-day blanking period. The prespecified performance goals were set at >40% and <13% for the primary efficacy and safety endpoints, respectively. Secondary endpoints assessed quality of life using the AFEQT (Atrial Fibrillation Effect on Quality of Life) and SF (Short Form)-12 questionnaires. RESULTS: Of 186 total enrollments, 165 subjects (70% male; age 65 ± 9 years; left atrial diameter 4.2 ± 0.6 cm; body mass index 31 ± 6) were treated at 25 sites in the United States, Canada, and Japan. Total procedural, left atrial dwell, and fluoroscopy times were 121 ± 46 minutes, 102 ± 41 minutes, and 19 ± 16 minutes, respectively. At 12 months, the primary efficacy endpoint was 54.8% (95% confidence [CI] 46.7%-62.1%) freedom from AF, AFL, or AT. There was 1 primary safety event, translating to a rate of 0.6% (95% CI 0.1%-4.4%). AFEQT and SF-12 assessments demonstrated significant improvements from baseline to 12 months postablation (P <.001). CONCLUSION: The STOP Persistent AF trial demonstrated cryoballoon ablation to be safe and effective in treating patients with drug-refractory persistent AF characterized by continuous AF episodes <6 months.


Assuntos
Técnicas de Ablação/métodos , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Qualidade de Vida , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Recidiva , Resultado do Tratamento
19.
Heart Rhythm ; 17(3): 485-491, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31606461

RESUMO

BACKGROUND: Pulmonary vein isolation by catheter ablation is a class IA indication for the treatment of symptomatic, drug-refractory, paroxysmal atrial fibrillation (PAF). Quality of life (QoL) has been identified as a clinically meaningful endpoint but has not been comprehensively evaluated to date. OBJECTIVE: The purpose of this study was to evaluate the effects of cryoballoon ablation on long-term QoL. METHODS: As part of the STOP-AF Post-Approval Study, QoL was assessed using the Short Form-12 Health Survey (SF-12) along with evaluation of arrhythmia-related symptoms through 36 months. A multivariate linear mixed effects regression was used to determine the association between atrial fibrillation symptoms and QoL scores, and univariate linear regressions were used to assess predictors of 36-month change in QoL scores. RESULTS: Three hundred thirty-five subjects fully completed SF-12 forms at baseline, with 319, 308, 291, and 278 subjects completing surveys at the subsequent follow-up visits. Both physical and mental composite scores increased significantly from baseline (P <.001), and all arrhythmia symptoms significantly decreased from baseline (P <.001), with 62.0% of subjects reporting no symptoms at 6 months compared to 5.7% at baseline (P <.001). Presence of dyspnea and fatigue at baseline were univariate predictors of physical QoL improvement (P = .045 and 0.0497, respectively), whereas each year of age and each year of PAF duration were predictors of a decrease in mental QoL (P = .014 and .04, respectively). CONCLUSION: Cryoballoon ablation for treatment of PAF results in a significant, and sustained, QoL improvement. The observed improvement in physical and mental health likely may be mediated by a reduction in symptom and arrhythmia burden.


Assuntos
Técnicas de Ablação/métodos , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Qualidade de Vida , Taquicardia Paroxística/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/psicologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Taquicardia Paroxística/fisiopatologia , Taquicardia Paroxística/psicologia , Resultado do Tratamento
20.
Circulation ; 140(22): 1779-1788, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31630538

RESUMO

BACKGROUND: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation. METHODS: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder. RESULTS: One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%-100.0%) with CF-RF, 99.9% (interquartile range, 65.3%-100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%-100.0%) with Cryo-2 (P=0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups (P=0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 vs cryoballoon groups). CONCLUSIONS: In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913522.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Feminino , Fluoroscopia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...