Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 28(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38067411

RESUMO

The absorption/desorption of water vapor by bambus[6]uril (Bu[6]) has been studied. According to kinetic experiments, the absorption capacity of Bu[6] is 4 moles of water per 1 mole of Bu[6] with the absorption duration of 20 min and the complete desorption duration of 100 min. Experimental rate constants for water vapor absorption and desorption by Bu[6] have been determined to be 0.166 min-1 and 0.0221 min-1, respectively. The obtained results are in agreement with theoretical calculations using the DFT method. A hypothetical structure of bambus[6]uril tetrahydrate (Bu[6]·4H2O) has been proposed based on the experimental and DFT data.

2.
Membranes (Basel) ; 13(8)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37623762

RESUMO

The development of accessible express methods to determine markers of viral diseases in saliva is currently an actual problem. Novel cross-sensitive sensors based on Donnan potential with bio-comparable perfluorosulfonic acid membranes for the determination of salivary viral markers (N-acetyl-L-methionine, L-carnitine, and L-lysine) were proposed. Membranes were formed by casting from dispersions of Nafion or Aquivion in N-methyl-2-pyrollidone or in a mixture of isopropyl alcohol and water. The influence of the polymer equivalent weight and the nature of dispersing liquid on water uptake, ion conductivity, and slope of Donnan potential for the membranes in H+ and Na+ form was investigated. The varying of the sorption and transport properties of perfluorosulfonic acid membranes provided a change in the distribution of the sensor sensitivity to N-acetyl-L-methionine, L-carnitine, and L-lysine ions, which was necessary for multisensory system development. The simultaneous determination of three analytes, and the group analysis of them in artificial saliva solutions, was performed. The errors of N-acetyl-L-methionine and L-carnitine determination were 4-12 and 3-11%, respectively. The determination of L-lysine was complicated by its interaction with Ca2+ ions. The error of the group analysis was no greater than 9%. The reverse character of the viral markers' sorption by the membranes provided long-term sensor operation.

3.
ACS Omega ; 4(7): 11472-11480, 2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31460252

RESUMO

Although nanoparticles of heavy metal xanthates and their hydrosols can play important roles in froth flotation, environmental issues, analytics, and manufacturing of metal sulfide nanocomposites, they have received little attention. We studied colloidal solutions and immobilized particles prepared via interaction of aqueous lead nitrate with alkyl xanthates applying UV-vis absorption spectroscopy, dynamic light scattering, zeta potential measurement, thermogravimetry analysis, Fourier transform infrared spectroscopy, Raman scattering, X-ray photoelectron spectroscopy, atomic force microscopy, and transmission electron microscopy. The hydrodynamic diameter of colloidal particles of Pb(SSCOR)2 decreased from 500 to 50 nm with an increase in the alkyl radical length and the initial xanthate to lead ratio (X/Pb); the zeta potential magnitude varied similarly, although it remained negative. The effect of pH in the range of 4.5-11 was minor, but the colloids produced using excess of Pb2+ in alkaline media were close to PbX and decomposed much easier than PbX2. The uptake of lead xanthates on supports was generally low because of negative charges of the colloids; however, 50-100 nm thick PbX2 films were deposited on PbS and SiO2 from the media of X/Pb < 2 and pH < 9 because of preadsorption of Pb2+, while nanorods formed on highly oriented pyrolytic graphite.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...