Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Bone Joint J ; 100-B(8): 1060-1065, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30062936

RESUMO

Aims: The aim of this study was to evaluate two hypotheses. First, that disruption of posterior bundle of the medial collateral ligament (PMCL) has to occur for the elbow to subluxate in cases of posteromedial rotatory instability (PMRI) and second, that ulnohumeral contact pressures increase after disruption of the PMCL. Materials and Methods: Six human cadaveric elbows were prepared on a custom-designed apparatus which allowed muscle loading and passive elbow motion under gravitational varus. Joint contact pressures were measured sequentially in the intact elbow (INTACT), followed by an anteromedial subtype two coronoid fracture (COR), a lateral collateral ligament (LCL) tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL). Results: There was no subluxation or joint incongruity in the INTACT, COR, and COR + LCL specimens. All specimens in the COR + LCL + PMCL group subluxated under gravity-varus loads. The mean articular contact pressure of the COR + LCL group was significantly higher than those in the INTACT and the COR groups. The mean articular contact pressure of the COR + LCL + PMCL group was significantly higher than that of the INTACT group, but not higher than that of the COR + LCL group. Conclusion: In the presence of an anteromedial fracture and disruption of the LCL, the posterior bundle of the MCL has to be disrupted for gross subluxation of the elbow to occur. However, elevated joint contact pressures are seen after an anteromedial fracture and LCL disruption even in the absence of such subluxation. Cite this article: Bone Joint J 2018;100-B:1060-5.


Assuntos
Ligamentos Colaterais/fisiologia , Articulação do Cotovelo/fisiologia , Instabilidade Articular/fisiopatologia , Idoso , Cadáver , Ligamentos Colaterais/lesões , Desenho de Equipamento , Fraturas Ósseas/fisiopatologia , Humanos , Luxações Articulares/fisiopatologia , Pressão , Amplitude de Movimento Articular/fisiologia , Rotação
2.
Int J Infect Dis ; 56: 90-100, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27810521

RESUMO

Tuberculosis (TB)-related stigma is an important social determinant of health. Research generally highlights how stigma can have a considerable impact on individuals and communities, including delays in seeking health care and adherence to treatment. There is scant research into the assessment of TB-related stigma in low incidence countries. This study aimed to systematically map out the research into stigma. A particular emphasis was placed on the methods employed to measure stigma, the conceptual frameworks used to understand stigma, and whether structural factors were theorized. Twenty-two studies were identified; the majority adopted a qualitative approach and aimed to assess knowledge, attitudes, and beliefs about TB. Few studies included stigma as a substantive topic. Only one study aimed to reduce stigma. A number of studies suggested that TB control measures and representations of migrants in the media reporting of TB were implicated in the production of stigma. The paucity of conceptual models and theories about how the social and structural determinants intersect with stigma was apparent. Future interventions to reduce stigma, and measurements of effectiveness, would benefit from a stronger theoretical underpinning in relation to TB stigma and the intersection between the social and structural determinants of health.


Assuntos
Saúde Pública , Determinantes Sociais da Saúde/estatística & dados numéricos , Estigma Social , Tuberculose/epidemiologia , Tuberculose/psicologia , Pesquisa Comportamental , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Incidência , Adesão à Medicação/psicologia , Adesão à Medicação/estatística & dados numéricos , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Tuberculose/tratamento farmacológico
3.
Bone Joint Res ; 5(9): 403-11, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27660334

RESUMO

OBJECTIVES: We sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling. MATERIALS AND METHODS: Adult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically. RESULTS: At 16 weeks post-operatively, histological scores amongst treatment groups were not statistically different (TMPG: overall 12.7, cartilage 8.6, bone 4.1; TM: overall 14.2, cartilage 9.5, bone 4.9; ED: overall 13.6, cartilage 9.1, bone 4.5). Metal scaffolds were incorporated into the surrounding bone, both in TM and TMPG. The sGAG yield was lower in the neo-cartilage regions compared with the articular cartilage (AC) controls (TMPG 20.8/AC 39.5, TM 25.6/AC 33.3, ED 32.2/AC 40.2 µg sGAG/1 mg respectively), with statistical significance being achieved for the TMPG group (p < 0.05). Hypercellularity of the neo-cartilage was found in TM and ED, as the dsDNA content was significantly higher (p < 0.05) compared with contralateral AC controls (TM 126.7/AC 71.1, ED 99.3/AC 62.8 ng dsDNA/1 mg). The highest type II collagen content was found in neo-cartilage after TM compared with TMPG and ED (TM 60%/TMPG 40%/ED 39%). Inter-treatment differences were not significant. CONCLUSIONS: TM is a highly suitable material for the reconstitution of osseous defects. TM enables excellent bony ingrowth and fast integration. However, combined with autologous periosteum, such a biocomposite failed to promote satisfactory neo-cartilage formation.Cite this article: E. H. Mrosek, H-W. Chung, J. S. Fitzsimmons, S. W. O'Driscoll, G. G. Reinholz, J. C. Schagemann. Porous tantalum biocomposites for osteochondral defect repair: A follow-up study in a sheep model. Bone Joint J 2016;5:403-411. DOI: 10.1302/2046-3758.59.BJR-2016-0070.R1.

4.
IEEE Trans Biomed Circuits Syst ; 5(2): 120-30, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23851200

RESUMO

This paper describes an analog-to-digital converter (ADC) array for an implantable neural sensor which digitizes neural signals sensed by a microelectrode array. The ADC array consists of 96 variable resolution ADC base cells. The resolution of each ADC cell in the array is varied according to neural data content of the signal from the corresponding electrode. The resolution adaptation algorithm is essentially to periodically recalibrate the required resolution and this is done without requiring any additional ADC cells. The adaptation implementation and results are described. The base ADC cell is implemented using a successive approximation charge redistribution architecture. The choice of architecture and circuit design are presented. The base ADC has been implemented in 0.13 µm CMOS as a 100 kS/s SAR ADC whose resolution can be varied from 3 to 8 bits with corresponding power consumption of 0.23 µW to 0.90 µW achieving an ENOB of 7.8 at the 8-bit setting. The energy per conversion step figure of merit is 48 fJ/step at the 8-bit setting. Resolution adaptation reduces power consumption by a factor of 2.3 for typical motor neuron signals while maintaining an effective 7.8-bit resolution across all channels.

5.
Osteoarthritis Cartilage ; 18(9): 1183-91, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20633683

RESUMO

OBJECTIVE: To compare the efficacy of in situ transforming growth factor-beta1 (TGF-beta1)-pretreated periosteum to untreated periosteum for regeneration of osteochondral tissue in rabbits. METHODS: In the pretreatment group, 12 month-old New Zealand white rabbits received subperiosteal injections of 200 ng of TGF-beta1 percutaneously in the medial side of the proximal tibia, 7 days prior to surgery. Control rabbits received no treatment prior surgery. Osteochondral transverse defects measuring 5mm proximal to distal and spanning the entire width of the patellar groove were created and repaired with untreated or TGF-beta1-pretreated periosteal grafts. Post-operatively the rabbits resumed normal cage activity for 6 weeks. RESULTS: Complete filling of the defects with regenerated tissue was observed in both the TGF-beta1-pretreated and control groups with reformation of the original contours of the patellar groove. The total histological score (modified O'Driscoll) in the TGF-beta1-pretreated group, 20 (95% Confidence Interval (CI), 19-21), was significantly higher (P=0.0001) than the control group, 18 (16-19). The most notable improvements were in structural integrity and subchondral bone regeneration. No significant differences in glycosaminoglycan or type II collagen content, or equilibrium modulus were found between the surgical groups. The cambium of the periosteum regenerated at the graft harvest site was significantly thicker (P=0.0065) in the TGF-beta1-pretreated rabbits, 121 microm (94-149), compared to controls, 74 microm (52-96), after 6 weeks. CONCLUSIONS: This study demonstrates that in situ pretreatment of periosteum with TGF-beta1 improves osteochondral tissue regeneration at 6-weeks post-op compared to untreated periosteum in 12 month-old rabbits.


Assuntos
Cartilagem Articular/efeitos dos fármacos , Cartilagem Articular/lesões , Condrogênese/efeitos dos fármacos , Periósteo/efeitos dos fármacos , Periósteo/patologia , Engenharia Tecidual/métodos , Fator de Crescimento Transformador beta1/farmacologia , Animais , Cartilagem Articular/fisiopatologia , Condrogênese/fisiologia , Modelos Animais de Doenças , Coelhos , Transplante de Tecidos , Transplante Autólogo , Cicatrização/efeitos dos fármacos , Cicatrização/fisiologia
6.
Osteoarthritis Cartilage ; 18(7): 981-91, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20434575

RESUMO

OBJECTIVE: To determine the potential of periosteal cells to infiltrate poly-epsilon-caprolactone (PCL) nanofiber scaffolds in vivo and subsequently produce cartilage in vitro. DESIGN: PCL nanofiber scaffolds, with or without chitosan-coating were implanted under periosteum in 6-month-old rabbits. Transforming growth factor-beta1 (TGF-beta1) or vehicle was injected into each implant site. After 1, 3, 5 or 7 days, scaffolds were removed, separated from the periosteum, and the scaffolds and periosteum were cultured separately for 6 weeks under chondrogenic conditions. Sulfated glycosaminoglycan (GAG), type II collagen, DNA content, cartilage yield, and calcium deposition were then analyzed. RESULTS: Cell infiltration was observed in all scaffolds. Cartilage formation in the uncoated scaffolds increased with duration of implantation (maximum at 7 days). Cells in the uncoated scaffolds implanted for 7 days produced significantly higher levels of both GAG [560 (95% confidence interval (CI), 107-1013) vs 228 (95% CI, 177-278) microg GAG/microg DNA] and cartilage yield [9% (95% CI, 3-14%) vs 0.02% (95% CI, 0-0.22%)] compared to chitosan-coated scaffolds (P=0.006 or less). There was no significant difference in GAG content or cartilage yield between the TGF-beta1-injected and vehicle-injected scaffolds. However, significantly more mineral deposition was detected in TGF-beta1-injected scaffolds compared to vehicle-injected scaffolds (P<0.0001). Cartilage yield from the periosteum, moreover, was significantly increased by subperiosteal TGF-beta1 injections (P<0.001). However, this response was reduced when chitosan-coated scaffolds were implanted. CONCLUSIONS: This study demonstrates that it is possible to seed PCL nanofiber scaffolds with periosteal cells in vivo and subsequently produce engineered cartilage in vitro.


Assuntos
Caproatos/metabolismo , Cartilagem/efeitos dos fármacos , Condrogênese/efeitos dos fármacos , Lactonas/metabolismo , Periósteo/efeitos dos fármacos , Engenharia Tecidual/métodos , Alicerces Teciduais , Fator de Crescimento Transformador beta/metabolismo , Animais , Cartilagem/crescimento & desenvolvimento , Nanofibras , Periósteo/citologia , Coelhos
7.
J Biomed Mater Res A ; 93(2): 454-63, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19582837

RESUMO

The aim of this study was to determine the suitability of hybrid scaffolds composed of naturally derived biopolymer gels and macroporous poly-epsilon-caprolactone (PCL) scaffolds for neocartilage formation in vitro. Rabbit articular chondrocytes were seeded into PCL/HA (1 wt % hyaluronan), PCL/CS (0.5 wt % chitosan), PCL/F (1:3 fibrin sealant plus aprotinin), and PCL/COL1 (0.24% type I collagen) hybrids and cultured statically for up to 50 days. Growth characteristics were evaluated by histological analysis, scanning electron microscopy, and confocal laser scanning microscopy. Neocartilage was quantified using a dimethyl-methylene blue assay for sulfated glycosaminoglycans (sGAG) and an enzyme-linked immunosorbent assay for type II collagen (COL2), normalized to dsDNA content by fluorescent PicoGreen assay. Chondrocytes were homogenously distributed throughout the entire scaffold and exhibited a predominantly spheroidal shape 1 h after being seeded into scaffolds. Immunofluorescence depicted expanding proteoglycan deposition with time. The sGAG per dsDNA increased in all hybrids between days 25 and 50. PCL/HA scaffolds consistently promoted highest yields. In contrast, total sGAG and total COL2 decreased in all hybrids except PCL/CS, which favored increasing values and a significantly higher total COL2 at day 50. Overall, dsDNA content decreased significantly with time, and particularly between days 3 and 6. The PCL/HA hybrid displayed two proliferation peaks at days 3 and 25, and PCL/COL1 displayed one proliferation peak at day 12. The developed hybrids provided distinct short-term environments for implanted chondrocytes, with not all of them being explicitly beneficial (PCL/F, PCL/COL1). The PCL/HA and PCL/CS hybrids, however, promoted specific neocartilage formation and initial cell retention and are thus promising for cartilage tissue engineering.


Assuntos
Cartilagem , Géis/química , Poliésteres/química , Engenharia Tecidual/instrumentação , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/química , Cartilagem/citologia , Cartilagem/fisiologia , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Condrócitos/metabolismo , Condrócitos/ultraestrutura , DNA/análise , Glicosaminoglicanos/química , Glicosaminoglicanos/metabolismo , Teste de Materiais , Coelhos , Engenharia Tecidual/métodos
8.
Osteoarthritis Cartilage ; 17(6): 723-34, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19064326

RESUMO

OBJECTIVE: To examine the potential for rejuvenation of aged periosteum by local injection of transforming growth factor-beta1 (TGF-beta1) and insulin-like growth factor-1 (IGF-1) alone or in combination to induce cambium cell proliferation and enhance in vitro periosteal cartilage formation. METHODS: A total of 367 New Zealand white rabbits (6, 12, and 24+ month-old) received subperiosteal injections of TGF-beta1 and/or IGF-1 percutaneously. After 1, 3, 5, or 7 days, the rabbits were sacrificed and cambium cellularity or in vitro cartilage forming capacity was determined. RESULTS: A significant increase in cambium cellularity and thickness, and in vitro cartilage formation was observed after injection of TGF-beta1 alone or in combination with IGF-1. In 12 month-old rabbits, mean cambium cellularity increased 5-fold from 49 to 237 cells/mm and in vitro cartilage production increased 12-fold from 0.8 to 9.7 mg 7 days after TGF-beta1 (200 ng) injection compared to vehicle controls (P<0.0001). A correlation was observed between cambium cellularity and in vitro cartilage production (R2=0.98). An added benefit of IGF-1 plus TGF-beta1 on in vitro cartilage production compared to TGF-beta1 alone was observed in the 2 year-old rabbits. IGF-1 alone generally had no effect on either cambium cellularity or in vitro cartilage production in any of the age groups. CONCLUSIONS: These results clearly demonstrate that it is possible to increase cambium cellularity and in vitro cartilage production in aged rabbit periosteum, to levels comparable to younger rabbits, using local injection of TGF-beta1 alone or in combination with IGF-1, thereby rejuvenating aged periosteum.


Assuntos
Cartilagem Articular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Fator de Crescimento Insulin-Like I/administração & dosagem , Periósteo/efeitos dos fármacos , Rejuvenescimento/fisiologia , Fator de Crescimento Transformador beta1/administração & dosagem , Animais , Cartilagem Articular/fisiopatologia , Condrogênese/efeitos dos fármacos , Periósteo/fisiopatologia , Coelhos
9.
Clin Biomech (Bristol, Avon) ; 21(6): 554-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16530305

RESUMO

Background. The treatment of radial head fractures that are not amenable to an open reduction and internal fixation, remains to be a difficult issue. A potential problem with prosthetic replacement of the radial head is the shape of current radial head prostheses. The purpose of this study was to determine the effect of the shape of the radial head on kinematics and load transfer of the elbow. Methods. Kinematics of the elbow and radiocapitellar force transmission were measured in 6 fresh frozen upper extremities. The effect of radial head shape was tested by rotating the head 90 degrees , with a custom-made 'native' radial head prosthesis. 3-D spatial orientation of the ulna showed an average difference in ulnohumeral laxity, between the nominal and 90 degrees conditions, of 0.1 degrees throughout the arc of motion with neutral forearm rotation (maximum: 2 degrees ). Findings. We found an average difference in ulnar axial rotation, of 0.1 degrees (maximum: 1.9 degrees ). No differences showed statistical significance. Radiohumeral joint force was measured and maximally showed a 32 times increase of force in the altered shape conditions. Interpretation. Our results show that the kinematics of the elbow was not affected by altering the shape of the radial head, but it did adversely affect the forces in the radiohumeral joint. This could possibly generate degenerative changes in the elbow.


Assuntos
Articulação do Cotovelo/anatomia & histologia , Articulação do Cotovelo/fisiologia , Movimento/fisiologia , Rádio (Anatomia)/anatomia & histologia , Rádio (Anatomia)/fisiologia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos/métodos , Cadáver , Humanos , Úmero/anatomia & histologia , Úmero/fisiologia , Técnicas In Vitro , Rotação , Estresse Mecânico , Ulna/anatomia & histologia , Ulna/fisiologia
10.
J Bone Joint Surg Am ; 87(9): 2019-27, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16140818

RESUMO

BACKGROUND: Many unlinked total elbow replacement designs with radically differing articular geometries exist, suggesting that there is no consensus regarding an optimal design. A feature inherent to the articular design is the intrinsic constraint afforded to the joint by the implant. Our aim was to compare the intrinsic constraints of unlinked implants with that of the normal ulnotrochlear joint. METHODS: We tested twelve cadaveric ulnotrochlear joints with a custom-made multiple-axis materials testing machine. With compressive loads ranging from 10 to 100 N, the joints were moved in either valgus or varus directions at 90 degrees of flexion. The ulnotrochlear components from a single example of five medium-sized unlinked elbow replacements (Ewald, Kudo, Pritchard ERS, Sorbie-Questor, and Souter-Strathclyde) were also tested. The recorded measurements included the torques and forces, angular displacement, and axial displacement of the humerus relative to the ulna. RESULTS: In general, the peak torque and the constraint ratio significantly increased with increasing compressive load for the implants as well as for the normal elbow. In valgus displacement, the Souter-Strathclyde implant had the highest and the Sorbie-Questor had the smallest peak torque and the Souter-Strathclyde had the highest and the Ewald had the smallest constraint ratio. In varus displacement, the Kudo had the highest and the Ewald had the smallest peak torque and constraint ratio. CONCLUSIONS: The constraint ratio is a characteristic that is useful for describing elbow joint behavior and for comparing the behavior of implants with that of the human elbow. Of the unlinked implants tested, the Souter-Strathclyde and Kudo prostheses most closely approximated the behavior of the human elbow joint. Implants that resemble the human elbow in appearance do not replicate normal behavior consistently, whereas other implants that do not resemble the human elbow closely do not deviate markedly from human behavior. Thus, much basic information about elbow form and function is needed to improve the performance of total elbow prostheses.


Assuntos
Artroplastia de Substituição , Articulação do Cotovelo , Prótese Articular , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Desenho de Prótese
11.
J Shoulder Elbow Surg ; 14(4): 429-32, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16015245

RESUMO

Details of the mechanical properties of hinged external fixators are essential to use the fixator properly in the clinical setting. A hinged external fixator (Dynamic Joint Distractor 2) was attached to the lateral side of 7 cadaveric elbows. Cantilever lateral bending tests were performed at 3 flexion angles in varus and valgus directions. Varied states of joint contact and axial loading were studied. Stiffness of the construct was calculated with uniaxial loading. Stiffness decreased with increased elbow flexion. Gap creation made the system less stiff. Axial loading made the system stiffer, especially in valgus testing. Stiffness in varus was approximately 4 times that in valgus. Lateral fixator application with half pins is most effective for protecting against varus-producing forces. When using the external fixator for unstable elbows, attention should be paid to the status of the articular surfaces and the integrity of the ligaments, and this should also be noted for elbow position during rehabilitation.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo/cirurgia , Fixadores Externos , Fraturas Ósseas/cirurgia , Instabilidade Articular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Pinos Ortopédicos , Cadáver , Desenho de Equipamento , Feminino , Humanos , Masculino , Amplitude de Movimento Articular
12.
Med Eng Phys ; 27(4): 336-42, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15823475

RESUMO

Comminuted radial head fractures can be treated with a radial head implant. The effects of lengthening (2.5 mm, 5 mm) and shortening (2.5 mm, 5 mm) of the radial neck, were compared to the nominal length in six human upper extremity cadavers. Total varus-valgus laxity and ulnar rotation were recorded. We hypothesized that restoring the exact length of the radius is important to maintain normal kinematics in the elbow joint. Lengthening or shortening of more than 2.5 mm significantly changed elbow kinematics. Lengthening caused a significant decrease (p < 0.001) in varus-valgus laxity, with the ulna tracking in varus and external rotation. Shortening caused a significant increase in varus-valgus laxity (p < 0.001) and ulnar rotation (p < 0.001), with the ulna tracking in valgus and internal rotation. Our study suggests that a restoration of radial length is important and that axial understuffing or overstuffing the radiohumeral joint by 2.5 mm or more, will alter elbow kinematics.


Assuntos
Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Análise de Falha de Equipamento/métodos , Prótese Articular , Ajuste de Prótese/métodos , Fraturas do Rádio/fisiopatologia , Fraturas do Rádio/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/métodos , Cadáver , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento
13.
J Bone Joint Surg Br ; 87(1): 54-61, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15686238

RESUMO

We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15). Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04). Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability.


Assuntos
Articulação do Cotovelo/cirurgia , Instabilidade Articular/cirurgia , Ligamentos Articulares/cirurgia , Adolescente , Adulto , Idoso , Criança , Feminino , Fraturas Ósseas/complicações , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Amplitude de Movimento Articular , Recidiva , Reoperação , Estudos Retrospectivos , Tendões/transplante , Resultado do Tratamento , Lesões no Cotovelo
14.
J Bone Joint Surg Am ; 86(12): 2629-35, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15590846

RESUMO

BACKGROUND: Comminuted radial head fractures associated with an injury of the medial collateral ligament can be treated with a radial head implant. We hypothesized that lengthening and shortening of the radial neck would alter the kinematics and the pressure through the radiocapitellar joint in the medial collateral ligament-deficient elbow. METHODS: The effects of lengthening (2.5 and 5 mm) and shortening (2.5 and 5 mm) of the radial neck were assessed in six human cadaveric upper extremities in which the medial collateral ligament had been surgically released. The three-dimensional spatial orientation of the ulna was recorded during simulated active motion from extension to flexion. Total varus-valgus laxity and ulnar rotation were measured. Radiocapitellar joint pressure was assessed with use of pressure-sensitive film. RESULTS: Radial neck lengthening or shortening of >/=2.5 mm significantly changed the kinematics in the medial collateral ligament-deficient elbow. Lengthening caused a significant decrease (p < 0.05) in varus-valgus laxity and ulnar rotation (p < 0.05), with the ulna tracking in varus and external rotation. Shortening caused a significant increase in varus-valgus laxity (p < 0.05) and ulnar rotation (p < 0.05), with the ulna tracking in valgus and internal rotation. The pressure on the radiocapitellar joint was significantly increased after 2.5 mm of lengthening. CONCLUSIONS: This study suggests that accurate restoration of radial length is important and that axial understuffing or overstuffing of the radiohumeral joint by >/=2.5 mm alters both elbow kinematics and radiocapitellar pressure. CLINICAL RELEVANCE: This in vitro cadaver study indicates that a radial head replacement should be performed with the same level of concern for accuracy and reproducibility of component position and orientation as is appropriate with any other prosthesis.


Assuntos
Ligamentos Colaterais/lesões , Lesões no Cotovelo , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Articulação do Cotovelo/fisiopatologia , Feminino , Humanos , Técnicas In Vitro , Prótese Articular , Masculino , Rádio (Anatomia)/cirurgia , Amplitude de Movimento Articular
15.
Clin Anat ; 17(7): 564-9, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15376292

RESUMO

Most radial head prostheses do not seem to be based on anatomic data. This may be due partly to the great variation of radial morphology. More importantly, few articles report on the dimensions of the radius. Authors have mainly studied dimensions of the radial head, with less emphasis to the relationship with the rest of the radius. Dimensions of, and relationship between, the proximal and the rest of the radius were measured on 27 fresh-frozen cadaveric upper extremities. Radial head, articulating surface, diaphysis, and distal radius were measured. Angles between the radial neck and diaphysis were defined and calculated. Axes of the distal and proximal radius were defined and radial torsion was calculated. Repeated measures were done by two observers in ten specimens. Inter- and intra-class correlation coefficients were very acceptable. Radial dimensions were found to be highly variable. Calculation of radial torsion showed the largest range. The average torsion was 54 degrees (range = 23-78 degrees). Radial length was 235 mm (range = 207-269 mm). Radial neck length was 13 mm (range = 9-19 mm). We found an average proximal diaphysis-neck angle of 17 degrees (range = 6-28 degrees). End to end-neck angle was 13 degrees (range = 4-22 degrees). Our findings indicate that even with a perfectly anatomical prosthesis, restoration of the anatomical situation can only be achieved when the implant is placed in the correct position. Instrumentation should be developed to allow accurate and reproducible implantation. The measurements we provide may aid this development.


Assuntos
Rádio (Anatomia)/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Pesos e Medidas Corporais/métodos , Cadáver , Feminino , Humanos , Masculino , Valores de Referência , Anormalidade Torcional
16.
Clin Biomech (Bristol, Avon) ; 19(6): 595-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15234483

RESUMO

OBJECTIVE: The objective of this study was to identify the effect of radial head shape and orientation on elbow kinematics in the otherwise intact elbow. DESIGN: Biomechanical study, analyzing simulated active motion of cadaveric arms. BACKGROUND: A discrepancy exists between the noncircular anatomy of the radial head and radial head prostheses. The effect of radial head shape is unknown. METHODS: Kinematic effects of radial head shape were tested in six fresh-frozen upper extremities. A custom-made native radial head prosthesis was used to simulate altered shape conditions, by rotating the radial head 90 degrees. Three-dimensional spatial orientation of the ulna was recorded, during simulated active motion. A three factor ANOVA was used to compare (a) nominal and 90 degrees oriented conditions, (b) throughout the flexion arc (c) in three forearm positions (P < 0.05). Post-hoc Tukey tests were done to assess significance. RESULTS: No significant effect of altering radial head shape was found on total ulnohumeral laxity and angulation during gravity valgus stress. We did find a significant effect on total ulnar axial rotation and rotation during gravity valgus stress. CONCLUSION: The outer shape of the radial head seems to change rotation of the ulna during flexion-extension in an otherwise intact elbow. RELEVANCE: The shape of the radial head effects intact elbow kinematics. Clinical importance of this finding is clear. If a sub-optimally placed radial head prosthesis were to be used in an otherwise intact elbow, the elbow could be at risk for early ulnohumeral arthritis.


Assuntos
Articulação do Cotovelo/fisiologia , Movimento/fisiologia , Rádio (Anatomia)/fisiologia , Fenômenos Biomecânicos/métodos , Cadáver , Humanos , Técnicas In Vitro , Amplitude de Movimento Articular/fisiologia , Rotação
17.
Biomaterials ; 25(9): 1511-21, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14697854

RESUMO

Animal models are widely used to develop and evaluate tissue-engineering techniques for the reconstruction of damaged human articular cartilage. For the purpose of this review, these model systems will include in vitro culture of animal cells and explants, heterotopic models of chondrogenesis, and articular cartilage defect models. The objectives for these preclinical studies are to engineer articular cartilage for the functional restoration of a joint surface that appears anatomically, histologically, biologically, biochemically, and mechanically to resemble the original joint surface. While no animal model permits direct application to humans, each is capable of yielding principles on which decisions can be made that might eventually translate into a human application. Clearly, the use of animal models has and will continue to play a significant role in the advancement of this field. Each animal model has specific advantages and disadvantages. The key issue in the selection of an appropriate animal model is to match the model to the question being investigated and the hypothesis to be tested. The purpose of this review is to discuss issues regarding animal model selection, the benefits and limitations of these model systems, scaffold selection with emphasis on polymers, and evaluation of the tissue-engineered articular cartilage.


Assuntos
Doenças das Cartilagens/cirurgia , Cartilagem Articular/crescimento & desenvolvimento , Técnicas de Cultura de Células/métodos , Condrogênese , Modelos Animais de Doenças , Procedimentos de Cirurgia Plástica/métodos , Engenharia Tecidual/métodos , Animais , Doenças das Cartilagens/classificação , Doenças das Cartilagens/patologia , Doenças das Cartilagens/fisiopatologia , Cartilagem Articular/lesões , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia , Técnicas de Cultura de Células/instrumentação , Humanos , Polímeros , Próteses e Implantes , Procedimentos de Cirurgia Plástica/instrumentação , Engenharia Tecidual/instrumentação , Resultado do Tratamento
18.
J Bone Joint Surg Am ; 85(6): 1005-11, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12783995

RESUMO

BACKGROUND: The posteromedial aspect of the olecranon process is a site of impingement and subsequent osteophyte development in throwing athletes. Treatment with débridement, with resection of osteophytes and varying amounts of normal olecranon bone, is common. We found no reports in the literature concerning the effects of resecting different amounts of normal bone from the posteromedial aspect of the olecranon. We hypothesized that excessive resection would increasingly alter elbow kinematics and that an optimum amount of olecranon resection could be identified. METHODS: We investigated the kinematic effects of increasing valgus and varus torques and posteromedial olecranon resections, in twelve cadaveric elbows, with use of an electromagnetic tracking device. Two valgus and two varus torques were applied, and three sequential resections were performed in 3-mm steps from 0 mm to 9 mm. Statistical analyses included paired t tests, 95% confidence intervals, a one-factor analysis of variance with repeated measures, and a post hoc test when significance was established. RESULTS: Sequential partial resection of the posteromedial aspect of the olecranon resulted in stepwise increases in valgus angulation with valgus torque. Clear differences were seen at each level of resection. A pattern of increased valgus angulation also was seen in association with increased valgus torque. Increased valgus torque resulted in a trend toward increased axial internal rotation of the ulna, whereas increased osseous resection resulted in a decrease in the absolute degree of internal rotation or, in some specimens, increased external rotation. CONCLUSIONS: Although no single critical amount of olecranon resection was identified, valgus angulation of the elbow increased in association with all resections, with a marked increase occurring in association with a 9-mm resection. Our findings challenge the rationale of removing any amount of normal olecranon bone in throwing athletes as doing so may increase strain on the medial collateral ligament. The implications for the professional throwing athlete are important, and we recommend that bone removal from the olecranon be limited to osteophytes, without the removal of normal bone.


Assuntos
Articulação do Cotovelo/fisiologia , Articulação do Cotovelo/cirurgia , Procedimentos Ortopédicos/métodos , Osteoartrite/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Articulação do Cotovelo/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Torque
19.
J Orthop Res ; 21(1): 162-6, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12507594

RESUMO

To elucidate the role of mechanical forces that resist motion of the long head of the biceps brachii, the gliding resistance of the tendon during abduction and adduction was measured. Nine human cadaveric glenohumeral joints were obtained (mean age 68 years, range 47-84). A testing device was developed to simulate glenohumeral abduction and adduction motion. Gliding resistance was calculated as the force differential on the proximal and distal ends of the biceps brachii at five glenohumeral angles (15 degrees, 30 degrees, 45 degrees, 60 degrees and 75 degrees ). The average gliding resistance in abduction at 15 degrees, 30 degrees, 45 degrees, 60 degrees and 75 degrees for a 4.9 N load was 0.41, 0.40, 0.36, 0.32 and 0.28 N, respectively. At these same angles, but during adduction motion, the force on the proximal tendon end was either identical or less than the distal tendon end (p>0.46) indicating a lack of resistance and even a phenomena of "negative" resistance in which some other force overcame the friction. The difference in gliding resistance between abduction and adduction was significant (p<0.05). The results indicate that forces opposing biceps tendon gliding are more complicated than simply due to friction. Tendon deformation inside the bicipital groove produces a direction-dependent effect due to a mechanism of elastic recoil. Understanding forces that are absorbed by the tendon during active motion may provide insight into pathological changes that develop inside and around the tendon.


Assuntos
Úmero/fisiologia , Movimento/fisiologia , Articulação do Ombro/fisiologia , Tendões/fisiologia , Fricção , Humanos , Músculo Esquelético/fisiologia , Resistência à Tração/fisiologia
20.
Osteoarthritis Cartilage ; 11(1): 55-64, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12505488

RESUMO

OBJECTIVE: Periosteum contains undifferentiated mesenchymal stem cells that have both chondrogenic and osteogenic potential, and has been used to repair articular cartilage defects. During this process, the role of growth factors that stimulate the periosteal mesenchymal cells toward chondrogenesis to regenerate articular cartilage and maintain its phenotype is not yet fully understood. In this study, we examined the effects of insulin-like growth factor-1 (IGF-1) and transforming growth factor-beta1 (TGF-beta1), alone and in combination, on periosteal chondrogenesis using an in vitro organ culture model. METHODS: Periosteal explants from the medial proximal tibia of 2-month-old rabbits were cultured in agarose under serum free conditions for up to 6 weeks. After culture the explants were weighed, assayed for cartilage production via Safranin O staining and histomorphometry, assessed for proliferation via proliferative cell nuclear antigen (PCNA) immunostaining, and assessed for type II collagen mRNA expression via in situ hybridization. RESULTS: IGF-1 significantly increased chondrogenesis in a dose-dependent manner when administered continuously throughout the culture period. Continuous IGF-1, in combination with TGF-beta1 for the first 2 days, further enhanced overall total cartilage growth. Immunohistochemistry for PCNA revealed that combining IGF-1 with TGF-beta1 gave the strongest proliferative stimulus early during chondrogenesis. In situ hybridization for type II collagen showed that continuous IGF-1 maintained type II collagen mRNA expression throughout the cambium layer from 2 to 6 weeks. CONCLUSION: The results of this study demonstrate that IGF-1 and TGF-beta1 can act in combination to regulate proliferation and differentiation of periosteal mesenchymal cells during chondrogenesis.


Assuntos
Cartilagem Articular/metabolismo , Condrogênese/efeitos dos fármacos , Fator de Crescimento Insulin-Like I/farmacologia , Fator de Crescimento Transformador beta/farmacologia , Animais , Colágeno Tipo II/metabolismo , Membro Posterior , Técnicas In Vitro , Fator de Crescimento Insulin-Like I/administração & dosagem , Periósteo/metabolismo , Coelhos , Fator de Crescimento Transformador beta/administração & dosagem , Fator de Crescimento Transformador beta1
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...