Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Invest New Drugs ; 40(4): 747-755, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35404015

RESUMO

Ephrin type-A 2 (EphA2) is a transmembrane receptor expressed in epithelial cancers. We report on a phase I dose escalation and biodistribution study of DS-8895a, an anti-EphA2 antibody, in patients with advanced EphA2 positive cancers. DS-8895a was administered at 1, 3, 10 or 20 mg/kg every 2 weeks to determine safety, pharmacokinetics and anti-tumor efficacy. All patients underwent 89Zr trace-labelled infusion of DS-8895a (89Zr-DS-8995a) positron emission tomography imaging to determine the biodistribution of DS-8895a, and correlate findings with EphA2 expression, receptor saturation and response. Nine patients were enrolled on study. Of patients enrolled, seven patients received at least one infusion of DS-8895a: four patients received 1 mg/kg dose (Cohort 1) and three patients received 3 mg/kg dose (Cohort 2). Median age was 67.0 years (range 52-81), majority male (71%), and median number of prior systemic therapies was three (range 0-8). The primary cancer diagnosis was colorectal cancer (two patients) and one patient each had gastric, head and neck, high-grade serous adenocarcinoma, lung, and pancreatic cancers. No dose-limiting toxicities or treatment-related adverse events reported. The best response for the patients in Cohort 1 was stable disease and in Cohort 2 was progressive disease. 89Zr-DS-8895a demonstrated no normal tissue uptake and specific low-grade uptake in most tumours. DS-8895a had limited therapeutic efficacy at doses evaluated and 89Zr-DS-8895a demonstrated low tumour uptake. The biodistribution data from this study were key in halting further development of DS-8895a, highlighting the importance of biodistribution studies in drug development. (Trial registration: ClinicalTrials.gov Identifier NCT02252211).


Assuntos
Anticorpos Monoclonais Humanizados , Antineoplásicos Imunológicos , Neoplasias , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Monoclonais Humanizados/uso terapêutico , Antineoplásicos , Antineoplásicos Imunológicos/farmacocinética , Antineoplásicos Imunológicos/uso terapêutico , Efrina-A2/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Receptor EphA2/efeitos dos fármacos , Distribuição Tecidual
2.
Neurooncol Adv ; 3(1): vdab102, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34549181

RESUMO

BACKGROUND: The adverse impact of increasing brain tumor size on the efficacy of antibody-drug conjugates (ADCs) was investigated preclinically then validated with clinical data. METHODS­PRECLINICAL STUDY: The impact of tumor size on ADC tumor delivery and treatment response was evaluated in an EGFR-amplified patient-derived glioblastoma (GBM) model following treatment with Depatuxizumab mafadotin (Depatux-M). Biodistribution and imaging studies correlated drug distribution with starting treatment volume and anti-tumor activity. METHODS­CLINICAL STUDY: M12-356 was a Phase I study of Depatux-M in patients with GBM. Blinded volumetric analysis of baseline tumor volumes of M12-356 patients was undertaken by two reviewers and results correlated with response and survival. RESULTS: Preclinically, imaging and biodistribution studies showed specific and significantly higher tumor uptake of zirconium-89 labeled Depatux-M (89Zr-Depatux-M) in mice with smaller tumor volume (~98 mm3) versus those with larger volumes (~365 mm3); concordantly, mice with tumor volumes ≤100 mm3 at treatment commencement had significantly better growth inhibition by Depatux-M (93% vs 27%, P < .001) and significantly longer overall survival (P < .0001) compared to tumors ≥400 mm3. Clinically, patients with tumor volumes <25 cm3 had significantly higher response rates (17% vs. 0%, P = .009) and longer overall survival (0.5 vs 0.89 years, P = .001) than tumors above 25 cm3. CONCLUSION: Both preclinical and clinical data showed intra-tumoral concentration and efficacy of Depatux-m inversely correlated with tumor size. This finding merit further investigation with pretreatment tumor volume as a predictor for response to ADCs, in both gliomas and other solid tumors.

3.
EBioMedicine ; 65: 103252, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33640794

RESUMO

BACKGROUND: A research priority in finding a cure for HIV is to establish methods to accurately locate and quantify where and how HIV persists in people living with HIV (PLWH) receiving suppressive antiretroviral therapy (ART). Infusing copper-64 (64Cu) radiolabelled broadly neutralising antibodies targeting HIV envelope (Env) with CT scan and positron emission tomography (PET) identified HIV Env in tissues in SIV infected non-human primates . We aimed to determine if a similar approach was effective in people living with HIV (PLWH). METHODS: Unmodified 3BNC117 was compared with 3BNC117 bound to the chelator MeCOSar and 64Cu (64Cu-3BNC117) in vitro to assess binding and neutralization. In a clinical trial 64Cu-3BNC117 was infused into HIV uninfected (Group 1), HIV infected and viremic (viral load, VL >1000 c/mL; Group 2) and HIV infected aviremic (VL <20 c/mL; Group 3) participants using two dosing strategies: high protein (3mg/kg unlabeled 3BNC117 combined with <5mg 64Cu-3BNC117) and trace (<5mg 64Cu-3BNC117 only). All participants were screened for 3BNC117 sensitivity from virus obtained from viral outgrowth. Magnetic resonance imaging (MRI)/PET and pharmacokinetic assessments (ELISA for serum 3BNC117 concentrations and gamma counting for 64Cu) were performed 1, 24- and 48-hours post dosing. The trial (clincialtrials.gov NCT03063788) primary endpoint was comparison of PET standard uptake values (SUVs) in regions of interest (e.g lymph node groups and gastrointestinal tract). FINDINGS: Comparison of unmodified and modified 3BNC117 in vitro demonstrated no difference in HIV binding or neutralisation. 17 individuals were enrolled of which 12 were dosed including Group 1 (n=4, 2 high protein, 2 trace dose), Group 2 (n=6, 2 high protein, 4 trace) and Group 3 (n=2, trace only). HIV+ participants had a mean CD4 of 574 cells/microL and mean age 43 years. There were no drug related adverse effects and no differences in tissue uptake in regions of interest (e.g lymph node gut, pharynx) between the 3 groups. In the high protein dosing group, serum concentrations of 3BNC117 and gamma counts were highly correlated demonstrating that 64Cu-3BNC117 remained intact in vivo. INTERPRETATION: In PLWH on or off ART, the intervention of infusing 64Cu-3BNC117 and MRI/PET imaging over 48 hours, was unable to detect HIV-1 env expression in vivo. Future studies should investigate alternative radiolabels such as zirconium which have a longer half-life in vivo. FUNDING: Funded by the Alfred Foundation, The Australian Centre for HIV and Hepatitis Virology Research with additional support from the Division of AIDS, National Institute of Allergy and Infectious Disease, US National Institutes of Health (USAI126611). JHM and SRL are supported by the Australian National Health and Medical Research Council.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Anti-HIV/química , Infecções por HIV/diagnóstico por imagem , HIV-1/imunologia , Compostos Radiofarmacêuticos/administração & dosagem , Adulto , Antirretrovirais/uso terapêutico , Anticorpos Monoclonais/imunologia , Linfócitos T CD4-Positivos/citologia , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD4-Positivos/virologia , Estudos de Casos e Controles , Radioisótopos de Cobre/química , Feminino , Anticorpos Anti-HIV/imunologia , Proteína gp120 do Envelope de HIV/imunologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/virologia , HIV-1/isolamento & purificação , HIV-1/metabolismo , Meia-Vida , Humanos , Marcação por Isótopo , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/imunologia , Compostos Radiofarmacêuticos/farmacocinética , Tomografia Computadorizada por Raios X
4.
J Clin Endocrinol Metab ; 106(1): e61-e73, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33090207

RESUMO

AIMS: To evaluate diagnostic performance of glomerular filtration rate (GFR) estimated by modification of diet in renal disease (MDRD), chronic kidney disease epidemiology collaboration (CKD-EPI), full age spectrum (FAS), and revised Lund-Malmö (r-LM) equations in adults with diabetes. METHODS: Individuals were included in this cross-sectional study if they had at least 1 measurement of technetium-99m diethylenetriamine-pentaacetic acid (99mTc-DTPA) GFR (mGFR) and serum creatinine (1487 patients with 2703 measures). GFR calculated by estimation equations was compared with mGFR. Diagnostic performance was assessed using concordance correlation coefficient (CCC), bias, precision, accuracy, reduced major axis regression (RMAR), and Bland-Altman plot. Analysis was repeated in subgroups based on sex, diabetes type, Hemoglobin A1C, and GFR level. RESULTS: Of all patients, 1189 (86%) had type 2 diabetes. Mean mGFR, MDRD, CKD-EPI, FAS, and revised Lund-Malmö eGFR were 66, 72, 74, 71, and 67 mL/min/1.73m2, respectively. Overall, the r-LM had the highest CCC (0.83), lowest bias (-1.4 mL/min/1.73 m2), highest precision (16.2 mL/min/1.73 m2), and highest accuracy (P10 = 39%). The RMAR (slope, intercept) in r-LM, FAS, MDRD, and CKD-EPI was 1.18, -13.35; 0.97, -2.9; 1, -6.4, and 1.04, -11.3, respectively. The Bland-Altman plot showed that r-LM had the lowest mean difference and the narrowest 95% limit of agreement (-1.0, 54.1 mL/min/1.73 m2), while mean difference was more than 5-fold higher in FAS, MDRD, and CKD-EPI (-5.2, -6.3, and -8.2, respectively). CONCLUSIONS: In adults with diabetes the revised Lund-Malmö performs better than MDRD, CKD-EPI, and FAS in calculating point estimates of GFR.


Assuntos
Creatinina/sangue , Diabetes Mellitus , Nefropatias Diabéticas/diagnóstico , Taxa de Filtração Glomerular , Adulto , Idoso , Algoritmos , Creatinina/análise , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/fisiopatologia , Diabetes Mellitus/urina , Nefropatias Diabéticas/sangue , Nefropatias Diabéticas/urina , Feminino , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Valor Preditivo dos Testes , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/urina , Reprodutibilidade dos Testes
5.
Theranostics ; 10(25): 11404-11415, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33052222

RESUMO

Through protein engineering and a novel pegylation strategy, a diabody specific to tumor-associated glycoprotein 72 (TAG-72) (PEG-AVP0458) has been created to optimize pharmacokinetics and bioavailability to tumor. We report the preclinical and clinical translation of PEG-AVP0458 to a first-in-human clinical trial of a diabody. Methods: Clinical translation followed characterization of PEG-AVP0458 drug product and preclinical biodistribution and imaging assessments of Iodine-124 trace labeled PEG-AVP0458 (124I-PEG-AVP0458). The primary study objective of the first-in-human study was the safety of a single protein dose of 1.0 or 10 mg/m2 124I-PEG-AVP0458 in patients with TAG-72 positive relapsed/ metastatic prostate or ovarian cancer. Secondary study objectives were evaluation of the biodistribution, tumor uptake, pharmacokinetics and immunogenicity. Patients were infused with a single-dose of 124I labeled PEG-AVP0458 (3-5 mCi (111-185 MBq) for positron emission tomography (PET) imaging, performed sequentially over a one-week period. Safety, pharmacokinetics, biodistribution, and immunogenicity were assessed up to 28 days after infusion. Results: PEG-AVP0458 was radiolabeled with 124I and shown to retain high TAG-72 affinity and excellent targeting of TAG-72 positive xenografts by biodistribution analysis and PET imaging. In the first-in-human trial, no adverse events or toxicity attributable to 124I-PEG-AVP0458 were observed. Imaging was evaluable in 5 patients, with rapid and highly specific targeting of tumor and minimal normal organ uptake, leading to high tumor:blood ratios. Serum concentration values of 124I-PEG-AVP0458 showed consistent values between patients, and there was no significant difference in T½α and T½ß between dose levels with mean (± SD) results of T½α = 5.10 ± 4.58 hours, T½ß = 46.19 ± 13.06 hours. Conclusions: These data demonstrates the safety and feasibility of using pegylated diabodies for selective tumor imaging and potential delivery of therapeutic payloads in cancer patients.


Assuntos
Anticorpos Biespecíficos/efeitos adversos , Antígenos de Neoplasias/metabolismo , Antineoplásicos/efeitos adversos , Neoplasias/tratamento farmacológico , Compostos Radiofarmacêuticos/efeitos adversos , Adulto , Animais , Anticorpos Biespecíficos/administração & dosagem , Anticorpos Biespecíficos/genética , Anticorpos Biespecíficos/farmacocinética , Anticorpos Antineoplásicos/genética , Antineoplásicos/administração & dosagem , Antineoplásicos/química , Antineoplásicos/farmacocinética , Disponibilidade Biológica , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Feminino , Humanos , Infusões Intravenosas , Radioisótopos do Iodo/administração & dosagem , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/farmacocinética , Masculino , Camundongos , Neoplasias/diagnóstico , Neoplasias/imunologia , Neoplasias/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/farmacocinética , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/genética , Proteínas Recombinantes/farmacocinética , Anticorpos de Cadeia Única/administração & dosagem , Anticorpos de Cadeia Única/efeitos adversos , Anticorpos de Cadeia Única/genética , Anticorpos de Cadeia Única/farmacocinética , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto
6.
EJNMMI Res ; 10(1): 61, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32533449

RESUMO

BACKGROUND: 4-[18F] fluorobenzyl dexetimide (F-DEX) is the first non-subtype selective fluorine-18 labelled tracer for muscarinic receptors (mAChR) used in humans. A recent first-in-human study found high regional brain uptake with low variation in normal subjects. Disturbance of mAChR has been reported in Alzheimer's and Parkinson's disease, schizophrenia and depression and various cardiac diseases. The following work assesses the biodistribution, organ tracer kinetics and radiation dose associated with F-DEX. METHOD: Dose calculations were based on activity uptake derived from multiple time point whole body PET CT imaging and the organ-specific dosimetric S-factors derived from the ICRP 133 standard man and woman mathematical phantoms. Effective doses were calculated using the latest ICRP tissue weighting factors. RESULTS: Serial images and time activity curves demonstrate high brain and left ventricular myocardial uptake (5% and 0.65% of injected activity, respectively) with greater retention in brain than myocardium. The mean effective dose was in concordance with other 18F labelled tracers at 19.70 ± 2.27 µSv/MBq. The largest absorbed doses were in the liver (52.91 ± 1.46 µGy/MBq) and heart wall (43.94 ± 12.88 µGy/MBq) for standard man and the liver (61.66 ± 13.61 µGy/MBq) and lungs (40.93 ± 3.11 µGy/MBq) for standard woman. The absorbed dose to all organs, most notably, the red bone marrow (20.03 ± 2.89 µGy/MBq) was sufficiently low to ensure no toxicity after numerous follow-up procedures. CONCLUSIONS: The radiation dose associated with an administration of F-DEX is comparable to that of other 18F labelled tracers such as FDG (19.0 µSv/MBq) and lower than tracers used for SPECT imaging of muscarinic receptors (I-DEX 28.5 µSv/MBq). Clinical use would likely result in an effective dose less than 4 mSv for the ICRP 133 standard phantoms after dose optimisation allowing justification for numerous follow-up procedures. Recent results from first in-human studies and a comparatively low radiation dose make F-DEX an attractive option for future applications of imaging muscarinic receptors in the brain. Further investigation of the potential of F-DEX for imaging parasympathetic innervation of the heart may be warranted.

7.
Eur J Nucl Med Mol Imaging ; 47(6): 1476-1485, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32025750

RESUMO

INTRODUCTION: Tumor hypoxia is a centerpiece of disease progression mechanisms such as neoangiogenesis or aggressive hypoxia-resistant malignant cells selection that impacts on radiotherapy strategies. Early identification of regions at risk for recurrence and prognostic-based classification of patients is a necessity to devise tailored therapeutic strategies. We developed an image-based algorithm to spatially map areas of aerobic and anaerobic glycolysis (Glyoxia). METHODS: 18F-FDG and 18F-FMISO PET studies were used in the algorithm to produce DICOM-co-registered representations and maximum intensity projections combined with quantitative analysis of hypoxic volume (HV), hypoxic glycolytic volume (HGV), and anaerobic glycolytic volume (AGV) with CT/MRI co-registration. This was applied to a prospective clinical trial of 10 glioblastoma patients with post-operative, pre-radiotherapy, and early post-radiotherapy 18F-FDG and 18F-FMISO PET and MRI studies. RESULTS: In the 10 glioblastoma patients (5M:5F; age range 51-69 years), 14/18 18F-FMISO PET studies showed detectable hypoxia. Seven patients survived to complete post-radiotherapy studies. The patient with the longest overall survival showed non-detectable hypoxia in both pre-radiotherapy and post-radiotherapy 18F-FMISO PET. The three patients with increased HV, HGV, and AGV volumes after radiotherapy showed 2.8 months mean progression-free interval vs. 5.9 months for the other 4 patients. These parameters correlated at that time point with progression-free interval. Parameters combining hypoxia and glycolytic information (i.e., HGV and AGV) showed more prominent variation than hypoxia-based information alone (HV). Glyoxia-generated images were consistent with disease relapse topology; in particular, one patient had distant relapse anticipated by HV, HGV, and AGV maps. CONCLUSION: Spatial mapping of aerobic and anaerobic glycolysis allows unique information on tumor metabolism and hypoxia to be evaluated with PET, providing a greater understanding of tumor biology and potential response to therapy.


Assuntos
Glioblastoma , Idoso , Fluordesoxiglucose F18 , Glioblastoma/diagnóstico por imagem , Glioblastoma/radioterapia , Glicólise , Humanos , Hipóxia/diagnóstico por imagem , Pessoa de Meia-Idade , Misonidazol , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/radioterapia , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos
8.
J Nucl Med ; 59(4): 636-638, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29326354

RESUMO

We report the discovery of a systematic miscalibration during the work-up process for site validation of a multicenter clinical PET imaging trial using 68Ga, which manifested as a consistent and reproducible underestimation in the quantitative accuracy (assessed by SUV) of a range of PET systems from different manufacturers at several different facilities around Australia. Methods: Sites were asked to follow a strict preparation protocol to create a radioactive phantom with 68Ga to be imaged using a standard clinical protocol before commencing imaging in the trial. All sites had routinely used 68Ga for clinical PET imaging for many years. The reconstructed image data were transferred to an imaging core laboratory for analysis, along with information about ancillary equipment such as the radionuclide dose calibrator. Fourteen PET systems were assessed from 10 nuclear medicine facilities in Australia, with the aim for each PET system being to produce images within 5% of the true SUV. Results: At initial testing, 10 of the 14 PET systems underestimated the SUV by 15% on average (range, 13%-23%). Multiple PET systems at one site, from two different manufacturers, were all similarly affected, suggesting a common cause. We eventually identified an incorrect factory-shipped dose calibrator setting from a single manufacturer as being the cause. The calibrator setting for 68Ga was subsequently adjusted by the users so that the reconstructed images produced accurate values. Conclusion: PET imaging involves a chain of measurements and calibrations to produce accurate quantitative performance. Testing of the entire chain is simple, however, and should form part of any quality assurance program or prequalifying site assessment before commencing a quantitative imaging trial or clinical imaging.


Assuntos
Radioisótopos de Gálio , Achados Incidentais , Tomografia por Emissão de Pósitrons , Doses de Radiação , Artefatos , Calibragem , Ensaios Clínicos como Assunto , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Theranostics ; 6(12): 2225-2234, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27924159

RESUMO

Background: DS-8273a, an anti-human death receptor 5 (DR5) agonistic antibody, has cytotoxic activity against human cancer cells and induces apoptosis after specific binding to DR5. DS-8273a is currently being used in clinical Phase I trials. This study evaluated the molecular imaging of DR5 expression in vivo in mouse tumor models using SPECT/CT and PET/MRI, as a tool for drug development and trial design. Methods: DS-8273a was radiolabeled with indium-111 and zirconium-89. Radiochemical purity, immunoreactivity, antigen binding affinity and serum stability were assessed in vitro. In vivo biodistribution and pharmacokinetic studies were performed, including SPECT/CT and PET/MR imaging. A dose-escalation study using a PET/MR imaging quantitative analysis was also performed to determine DR5 receptor saturability in a mouse model. Results:111In-CHX-A″-DTPA-DS-8273a and 89Zr-Df-Bz-NCS-DS-8273a showed high immunoreactivity (100%), high serum stability, and bound to DR5 expressing cells with high affinity (Ka, 1.02-1.22 × 1010 M-1). The number of antibodies bound per cell was 32,000. In vivo biodistribution studies showed high and specific uptake of 111In-CHX-A″-DTPA-DS-8273a and 89Zr-Df-Bz-NCS-DS-8273a in DR5 expressing COLO205 xenografts, with no specific uptake in normal tissues or in DR5-negative CT26 xenografts. DR5 receptor saturation was observed in vivo by biodistribution studies and quantitative PET/MRI analysis. Conclusion:89Zr-Df-Bz-NCS-DS-8273a is a potential novel PET imaging reagent for human bioimaging trials, and can be used for effective dose assessment and patient response evaluation in clinical trials.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/terapia , Anticorpos/administração & dosagem , Radioisótopos/administração & dosagem , Receptores do Ligante Indutor de Apoptose Relacionado a TNF/antagonistas & inibidores , Nanomedicina Teranóstica/métodos , Zircônio/administração & dosagem , Animais , Linhagem Celular Tumoral , Modelos Animais de Doenças , Xenoenxertos , Humanos , Índio/administração & dosagem , Índio/farmacocinética , Imageamento por Ressonância Magnética , Camundongos Endogâmicos BALB C , Tomografia por Emissão de Pósitrons , Radioisótopos/farmacocinética , Radioterapia/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Zircônio/farmacocinética
10.
J Labelled Comp Radiopharm ; 59(10): 416-23, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27435268

RESUMO

The significance of imaging hypoxia with the positron emission tomography ligand [(18) F]FMISO has been demonstrated in a variety of cancers. However, the slow kinetics of [(18) F]FMISO require a 2-h delay between tracer administration and patient scanning. Labeled chloroethyl sulfoxides have shown faster kinetics and higher contrast than [(18) F]FMISO in a rat model of ischemic stroke. However, these nitrogen mustard analogues are unsuitable for routine production and use in humans. Here, we report on the synthesis and in vitro and in vivo evaluation of a novel sulfoxide, which contains an ester moiety for hydrolysis and subsequent trapping in hypoxic cells. Non-decay corrected yields of radioactivity were 1.18 ± 0.24% (n = 27, 2.5 ± 0.5% decay corrected radiochemical yield) based on K[(18) F]F. The radiotracer did not show any defluorination and did not undergo metabolism in an in vitro assay using S9 liver fractions. Imaging studies using an SK-RC-52 tumor model in BALB/c nude mice have revealed that [(18) F]1 is retained in hypoxic tumors and has similar hypoxia selectivity to [(18) F]FMISO. Because of a three times faster clearance rate than [(18) F]FMISO from normoxic tissue, [(18) F]1 has emerged as a promising new radiotracer for hypoxia imaging.


Assuntos
Radioisótopos de Flúor , Glicina/análogos & derivados , Sulfóxidos , Hipóxia Tumoral , Animais , Linhagem Celular Tumoral , Estabilidade de Medicamentos , Glicina/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Marcação por Isótopo , Camundongos , Imagem Molecular , Radioquímica , Sulfóxidos/química
11.
Mol Imaging ; 152016.
Artigo em Inglês | MEDLINE | ID: mdl-27457521

RESUMO

PURPOSE: The aims of the study were to develop and evaluate a novel residualizing peptide for labeling internalizing antibodies with (124)I to support clinical development using immuno-positron emission tomography (PET). METHODS: The anti-epidermal growth factor receptor antibody ch806 was radiolabeled directly or indirectly with isotopes and various residualizing peptides. Azido-derivatized radiolabeled peptides were conjugated to dibenzylcyclooctyne-derivatized ch806 antibody via click chemistry. The radiochemical purities, antigen-expressing U87MG.de2-7 human glioblastoma cell-binding properties, and targeting of xenografts at 72 hours post injection of all radioconjugates were compared. Biodistribution of (124)I-PEG4-tptddYddtpt-ch806 and immuno-PET imaging were evaluated in tumor-bearing mice. RESULTS: Biodistribution studies using xenografts at 72 hours post injection showed that (131)I-PEG4-tptddYddtpt-ch806 tumor uptake was similar to (111)In-CHX-A″-DTPA-ch806. (125)I-PEG4-tptddyddtpt-ch806 showed a lower tumor uptake value but higher than directly labeled (125)I-ch806. (124)I-PEG4-tptddYddtpt-ch806 was produced at 23% labeling efficiency, 98% radiochemical purity, 25.9 MBq/mg specific activity, and 64% cell binding in the presence of antigen excess. Tumor uptake for (124)I-PEG4-tptddYddtpt-ch806 was similar to (111)In-CHX-A″-DTPA-ch806. High-resolution immuno-PET/magnetic resonance imaging of tumors showed good correlation with biodistribution data. CONCLUSIONS: The mixed d/l-enantiomeric peptide, dThr-dPro-dThr-dAsp-dAsp-Tyr-dAsp-dAsp-dThr-dPro-dThr, is suitable for radiolabeling antibodies with radiohalogens such as (124)I for high-resolution immuno-PET imaging of tumors and for evaluation in early-phase clinical trials.


Assuntos
Anticorpos Monoclonais/farmacocinética , Neoplasias Encefálicas/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Peptídeos/farmacocinética , Animais , Anticorpos Monoclonais/química , Linhagem Celular Tumoral , Humanos , Radioisótopos do Iodo/química , Camundongos , Transplante de Neoplasias , Peptídeos/química , Compostos Radiofarmacêuticos/química , Distribuição Tecidual , Tirosina
12.
MAbs ; 8(4): 775-86, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27030023

RESUMO

IgG has a long half-life through engagement of its Fc region with the neonatal Fc receptor (FcRn). The FcRn binding site on IgG1 has been shown to contain I253 and H310 in the CH2 domain and H435 in the CH3 domain. Altering the half-life of IgG has been pursued with the aim to prolong or reduce the half-life of therapeutic IgGs. More recent studies have shown that IgGs bind differently to mouse and human FcRn. In this study we characterize a set of hu3S193 IgG1 variants with mutations in the FcRn binding site. A double mutation in the binding site is necessary to abrogate binding to murine FcRn, whereas a single mutation in the FcRn binding site is sufficient to no longer detect binding to human FcRn and create hu3S193 IgG1 variants with a half-life similar to previously studied hu3S193 F(ab')2 (t1/2ß, I253A, 12.23 h; H310A, 12.94; H435A, 12.57; F(ab')2, 12.6 h). Alanine substitutions in S254 in the CH2 domain and Y436 in the CH3 domain showed reduced binding in vitro to human FcRn and reduced elimination half-lives in huFcRn transgenic mice (t1/2ß, S254A, 37.43 h; Y436A, 39.53 h; wild-type, 83.15 h). These variants had minimal effect on half-life in BALB/c nu/nu mice (t1/2ß, S254A, 119.9 h; Y436A, 162.1 h; wild-type, 163.1 h). These results provide insight into the interaction of human Fc by human FcRn, and are important for antibody-based therapeutics with optimal pharmacokinetics for payload strategies used in the clinic.


Assuntos
Anticorpos Monoclonais/química , Antígenos de Histocompatibilidade Classe I/imunologia , Imunoglobulina G/química , Receptores Fc/química , Animais , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/farmacologia , Meia-Vida , Humanos , Imunoglobulina G/imunologia , Imunoglobulina G/farmacologia , Antígenos do Grupo Sanguíneo de Lewis/imunologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Transgênicos , Engenharia de Proteínas , Estabilidade Proteica , Receptores Fc/imunologia
13.
J Nucl Med ; 57(6): 974-80, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26940768

RESUMO

UNLABELLED: Subtype A2 of the erythropoietin-producing hepatocellular tyrosine kinase (EphA2) cell surface receptor is expressed in a range of epithelial cancers. This study evaluated the molecular imaging of EphA2 expression in vivo in mouse tumor models using SPECT/MR and PET/MR and a humanized anti-EphA2 antibody, DS-8895a. METHODS: DS-8895a was labeled with (111)In, (125)I, and (89)Zr and assessed for radiochemical purity, immunoreactivity (Lindmo analysis), antigen-binding affinity (Scatchard analysis), and serum stability in vitro. In vivo biodistribution, imaging, and pharmacokinetic studies were performed with SPECT/MR and PET/MR. A dose-escalation study was also performed to determine EphA2 receptor saturability through tissue and imaging quantitative analysis. RESULTS: All conjugates demonstrated good serum stability and specific binding to EphA2-expressing cells in vitro. In vivo biodistribution studies showed high uptake of (111)In-CHX-A″-DTPA-DS-8895a and (89)Zr-Df-Bz-NCS-DS-8895a in EphA2-expressing xenograft models, with no specific uptake in normal tissues. In comparison, retention of (125)I-DS-8895a in tumors was lower because of internalization of the radioconjugate and dehalogenation. These results were confirmed by SPECT/MR and PET/MR. EphA2 receptor saturation was observed at the 30 mg/kg dose. CONCLUSION: Molecular imaging of tumor uptake of DS-8895a allows noninvasive measurement of EphA2 expression in tumors in vivo and determination of receptor saturation. (89)Zr-Df-Bz-NCS-DS-8895a is suited for human bioimaging trials on the basis of superior imaging characteristics and will inform DS-8895a dose assessment and patient response evaluation in clinical trials.


Assuntos
Anticorpos Monoclonais Humanizados/química , Transformação Celular Neoplásica , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos , Receptor EphA2/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zircônio/química , Animais , Anticorpos Monoclonais Humanizados/imunologia , Anticorpos Monoclonais Humanizados/farmacocinética , Linhagem Celular Tumoral , Desferroxamina/análogos & derivados , Desferroxamina/química , Feminino , Humanos , Isotiocianatos/química , Camundongos , Ácido Pentético/química , Controle de Qualidade , Receptor EphA2/imunologia , Distribuição Tecidual
14.
EJNMMI Res ; 6(1): 26, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26983636

RESUMO

BACKGROUND: The aim of the study was to explore Fc mutations of a humanised anti-Lewis-Y antibody (IgG1) hu3S193 as a strategy to improve therapeutic ratios for therapeutic payload delivery. METHODS: Four hu3S193 variants (I253A, H310A, H435A and I253A/H310A) were generated via site-directed mutagenesis and radiolabelled with diagnostic isotopes iodine-125 or indium-111. Biodistribution studies in Lewis-Y-positive tumour-bearing mice were used to calculate the dose in tumours and organs for therapeutic isotopes (iodine-131, yttrium-90 and lutetium-177). RESULTS: (111)In-labelled I253A and H435A showed similar slow kinetics (t 1/2ß, 63.2 and 62.2 h, respectively) and a maximum tumour uptake of 33.11 ± 4.05 and 33.69 ± 3.77 percentage injected dose per gramme (%ID/g), respectively. (111)In-labelled I253A/H310A cleared fastest (t 1/2ß, 9.1 h) with the lowest maximum tumour uptake (23.72 ± 0.85 %ID/g). The highest increase in tumour-to-blood area under the curve (AUC) ratio was observed with the metal-labelled mutants ((90)Y and (177)Lu). (177)Lu-CHX-A" DTPA-hu3S193 I253A/H310A (6:1) showed the highest tumour-to-blood AUC ratio compared to wild type (3:1) and other variants and doubling of calculated dose to tumour based on red marrow dose constraints. CONCLUSIONS: These results suggest that hu3S193 Fc can be engineered with improved therapeutic ratios for (90)Y- and (177)Lu-based therapy, with the best candidate being hu3S193 I253A/H310A for (177)Lu-based therapy.

15.
Inorg Chem ; 54(19): 9594-610, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26375592

RESUMO

With the aim of preparing hypoxia-selective imaging and therapeutic agents, technetium(I) and rhenium(I) tricarbonyl complexes with pyridylhydrazone, dipyridylamine, and pyridylaminocarboxylate ligands containing nitrobenzyl or nitroimidazole functional groups have been prepared. The rhenium tricarbonyl complexes were synthesized with short reaction times using microwave irradiation. Rhenium tricarbonyl complexes with deprotonated p-nitrophenyl pyridylhydrazone ligands are luminescent, and this has been used to track their uptake in HeLa cells using confocal fluorescent microscopy. Selected rhenium tricarbonyl complexes displayed higher uptake in hypoxic cells when compared to normoxic cells. A (99m)Tc tricarbonyl complex with a dipyridylamine ligand bearing a nitroimidazole functional group is stable in human serum and was shown to localize in a human renal cell carcinoma (RCC; SK-RC-52) tumor in a mouse.


Assuntos
Hipóxia , Compostos Organometálicos/farmacocinética , Rênio/farmacocinética , Tecnécio/farmacocinética , Animais , Linhagem Celular Tumoral , Diagnóstico por Imagem , Técnicas Eletroquímicas , Células HeLa , Humanos , Ligantes , Luminescência , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Microscopia de Fluorescência , Modelos Moleculares , Estrutura Molecular , Compostos Organometálicos/síntese química , Compostos Organometálicos/química , Rênio/química , Tecnécio/química , Distribuição Tecidual
16.
J Clin Oncol ; 33(24): 2609-16, 2015 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-26124477

RESUMO

PURPOSE: CS-1008 (tigatuzumab) is a humanized, monoclonal immunoglobulin G1 (IgG1) agonistic antibody to human death receptor 5. The purpose of this study was to investigate the impact of CS-1008 dose on the biodistribution, quantitative tumor uptake, and antitumor response in patients with metastatic colorectal cancer (mCRC). PATIENTS AND METHODS: Patients with mCRC who had received at least one course of chemotherapy were assigned to one of five dosage cohorts and infused with a weekly dose of CS-1008. Day 1 and day 36 doses were trace-labeled with indium-111 ((111)In), followed by whole-body planar and regional single-photon emission computed tomography (SPECT) imaging at several time points over the course of 10 days. RESULTS: Nineteen patients were enrolled. (111)In-CS-1008 uptake in tumor was observed in only 12 patients (63%). (111)In-CS-1008 uptake and pharmacokinetics were not affected by dose or repeated drug administration. (111)In-CS-1008 biodistribution showed gradual blood-pool clearance and no abnormal uptake in normal tissue. No anti-CS-1008 antibody development was detected. One patient achieved partial response (3.7 months duration), eight patients had stable disease, and 10 patients had progressive disease. Clinical benefit rate (stable disease + partial response) in patients with (111)In-CS-1008 uptake in tumor was 58% versus 28% in patients with no uptake. An analysis of individual lesions showed that lesions with antibody uptake were one third as likely to progress as those without antibody uptake (P = .07). Death-receptor-5 expression in archived tumor samples did not correlate with (111)In-CS-1008 uptake (P = .5) or tumor response (P = .6). CONCLUSION: Death-receptor-5 imaging with (111)In-CS-1008 reveals interpatient and intrapatient heterogeneity of uptake in tumor, is not dose dependent, and is predictive of clinical benefit in the treatment of patients who have mCRC.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/farmacocinética , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Relação Dose-Resposta a Droga , Feminino , Humanos , Radioisótopos de Índio , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Cintilografia , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual
17.
Mol Pharm ; 11(8): 2855-63, 2014 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-24999533

RESUMO

Imaging of activated platelets using an activation specific anti-GPIIb/IIIa integrin single-chain antibody (scFvanti-LIBS) conjugated to a positron emitting copper-64 complex of a cage amine sarcophagine chelator (MeCOSar) is reported. This tracer was compared in vitro to a (64)Cu(II) complex of the scFv conjugated to another commonly used macrocycle, DOTA. The scFvanti-LIBS-MeCOSar conjugate was radiolabeled with (64)Cu(II) rapidly under mild conditions and with higher specific activity than scFvanti-LIBS-DOTA. The utility of scFvanti-LIBS-MeCOSar as a diagnostic agent was assessed in vivo in a mouse model of acute thrombosis. The uptake of scFvanti-LIBS-(64)CuMeCOSar in the injured vessel was significantly higher than the noninjured vessel. Positron emission tomography (PET) was used to show accumulation of scFvanti-LIBS-(64)CuMeCOSar with high and specific uptake in the injured vessel. ScFvanti-LIBS-(64)CuMeCOSar is an excellent tool for highly sensitive in vivo detection of activated platelets in PET and has the potential to be used for early diagnosis of acute thrombotic events.


Assuntos
Plaquetas/efeitos dos fármacos , Quelantes/química , Tomografia por Emissão de Pósitrons , Anticorpos de Cadeia Única/química , Animais , Plaquetas/metabolismo , Artérias Carótidas/fisiopatologia , Cobre/química , Radioisótopos de Cobre/química , Diagnóstico por Imagem , Modelos Animais de Doenças , Citometria de Fluxo , Compostos Heterocíclicos com 1 Anel/química , Inflamação , Ligantes , Espectroscopia de Ressonância Magnética , Camundongos , Camundongos Endogâmicos BALB C , Ativação Plaquetária , Compostos Radiofarmacêuticos , Trombose/diagnóstico , Microtomografia por Raio-X
18.
Australas Phys Eng Sci Med ; 37(3): 495-503, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24859803

RESUMO

The scalable XCAT voxelised phantom was used with the GATE Monte Carlo toolkit to investigate the effect of voxel size on dosimetry estimates of internally distributed radionuclide calculated using direct Monte Carlo simulation. A uniformly distributed Fluorine-18 source was simulated in the Kidneys of the XCAT phantom with the organ self dose (kidney ← kidney) and organ cross dose (liver ← kidney) being calculated for a number of organ and voxel sizes. Patient specific dose factors (DF) from a clinically acquired FDG PET/CT study have also been calculated for kidney self dose and liver ← kidney cross dose. Using the XCAT phantom it was found that significantly small voxel sizes are required to achieve accurate calculation of organ self dose. It has also been used to show that a voxel size of 2 mm or less is suitable for accurate calculations of organ cross dose. To compensate for insufficient voxel sampling a correction factor is proposed. This correction factor is applied to the patient specific dose factors calculated with the native voxel size of the PET/CT study.


Assuntos
Simulação por Computador , Método de Monte Carlo , Interpretação de Imagem Radiográfica Assistida por Computador , Radiometria/métodos , Relação Dose-Resposta à Radiação , Fluordesoxiglucose F18 , Humanos , Rim/diagnóstico por imagem , Imagens de Fantasmas , Cintilografia
19.
Nucl Med Biol ; 41(5): 419-25, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24767600

RESUMO

[¹8F]FMISO is the most widely validated PET radiotracer for imaging hypoxic tissue. However, as a result of the pharmacokinetics of [¹8F]FMISO a 2h wait between tracer administration and patient scanning is required for optimal image acquisition. In order to develop hypoxia imaging agents with faster kinetics, we have synthesised and evaluated several F-18 labelled anilino sulfoxides. In this manuscript we report on the synthesis, in vitro and in vivo evaluation of a novel fluoroethyltriazolyl propargyl anilino sulfoxide. The radiolabelling of the novel tracer was achieved via 2-[¹8F]fluoroethyl azide click chemistry. Radiochemical yields were 23 ± 4% based on 2-[¹8F]fluoroethyl azide and 7 ± 2% based on K[¹8F]F. The radiotracer did not undergo metabolism or defluorination in an in vitro assay using S9 liver fractions. Imaging studies using SK-RC-52 tumors in BALB/c nude mice have indicated that the tracer may have a higher pO2 threshold than [¹8F]FMISO for uptake in hypoxic tumors. Although clearance from muscle was faster than [¹8F]FMISO, uptake in hypoxic tumors was slower. The average tumor to muscle ratio at 2h post injection in large, hypoxic tumors with a volume greater than 686 mm³ was 1.7, which was similar to the observed ratio of 1.75 for [¹8F]FMISO. Although the new tracer showed improved pharmacokinetics when compared with the previously synthesised sulfoxides, further modifications to the chemical structure need to be made in order to offer significant in vivo imaging advantages over [¹8F]FMISO.


Assuntos
Neoplasias Renais/patologia , Tomografia por Emissão de Pósitrons/métodos , Sulfóxidos , Animais , Hipóxia Celular , Linhagem Celular Tumoral , Humanos , Interações Hidrofóbicas e Hidrofílicas , Marcação por Isótopo , Camundongos , Radioquímica , Sulfóxidos/química , Sulfóxidos/farmacocinética
20.
J Nucl Med ; 55(4): 534-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24556590

RESUMO

UNLABELLED: huA33 is a humanized antibody that targets the A33 antigen, which is highly expressed in intestinal epithelium and more than 95% of human colon cancers but not other normal tissues. Previous studies have shown huA33 can target and be retained in a metastatic tumor for 6 wk but eliminated from normal colonocytes within days. This phase I study used radiolabeled huA33 in combination with capecitabine to target chemoradiation to metastatic colorectal cancer. The primary objective was safety and tolerability of the combination of capecitabine and (131)I-huA33. Pharmacokinetics, biodistribution, immunogenicity, and tumor response were also assessed. METHODS: Eligibility included measurable metastatic colorectal cancer, adequate hematologic and biochemical function, and informed consent. An outpatient scout (131)I-huA33 dose was followed by a single-therapy infusion 1 wk later, when capecitabine was commenced. Dose escalation occurred over 5 dose levels. Patients were evaluated weekly, with tumor response assessment at the end of the 12-wk trial. Tumor targeting was assessed using a γ camera and SPECT imaging. RESULTS: Nineteen eligible patients were enrolled. The most frequently observed toxicity included myelosuppression, gastrointestinal symptoms, and asymptomatic hyperbilirubinemia. Biodistribution analysis demonstrated excellent tumor targeting of the known tumor sites, expected transient bowel uptake, but no other normal tissue uptake. (131)I-huA33 demonstrated a mean terminal half-life and serum clearance suited to radioimmunotherapy (T1/2ß, 100.24 ± 20.92 h, and clearance, 36.72 ± 8.01 mL/h). The mean total tumor dose was 13.8 ± 7.6 Gy (range, 5.1-26.9 Gy). One patient had a partial response, and 10 patients had stable disease. CONCLUSION: (131)I-huA33 achieves specific targeting of radiotherapy to colorectal cancer metastases and can be safely combined with chemotherapy, providing an opportunity to deliver chemoradiation specifically to metastatic disease in colorectal cancer patients.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Quimiorradioterapia/métodos , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/terapia , Compostos Radiofarmacêuticos/uso terapêutico , Adulto , Idoso , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Antineoplásicos/imunologia , Antimetabólitos Antineoplásicos/uso terapêutico , Capecitabina , Neoplasias Colorretais/imunologia , Desoxicitidina/análogos & derivados , Desoxicitidina/uso terapêutico , Feminino , Fluoruracila/análogos & derivados , Fluoruracila/uso terapêutico , Humanos , Marcação por Isótopo , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Seleção de Pacientes , Radiometria , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...