1.
BMC Health Serv Res ; 23(1): 1377, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066492

RESUMO

BACKGROUND: Type 2 diabetes mellitus (T2DM) is highly prevalent within the Indigenous Australian community. Novel glucose monitoring technology offers an accurate approach to glycaemic management, providing real-time information on glucose levels and trends. The acceptability and feasibilility of this technology in Indigenous Australians with T2DM has not been investigated. OBJECTIVE: This feasibility phenomenological study aims to understand the experiences of Indigenous Australians with T2DM using flash glucose monitoring (FGM). METHODS: Indigenous Australians with T2DM receiving injectable therapy (n = 8) who used FGM (Abbott Freestyle Libre) for 6-months, as part of a clinical trial, participated in semi-structured interviews. Thematic analysis of the interviews was performed using NVivo12 Plus qualitative data analysis software (QSR International). RESULTS: Six major themes emerged: 1) FGM was highly acceptable to the individual; 2) FGM's convenience was its biggest benefit; 3) data from FGM was a tool to modify lifestyle choices; 4) FGM needed to be complemented with health professional support; 5) FGM can be a tool to engage communities in diabetes management; and 6) cost of the device is a barrier to future use. CONCLUSIONS: Indigenous Australians with T2DM had positive experiences with FGM. This study highlights future steps to ensure likelihood of FGM is acceptable and effective within the wider Indigenous Australian community.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Humanos , Austrália , Glicemia/análise , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/terapia , Estudos de Viabilidade , Projetos Piloto , Povos Aborígenes Australianos e Ilhéus do Estreito de Torres
2.
Diabetes Technol Ther ; 24(12): 873-880, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36094458

RESUMO

Aim: To compare evening and overnight hypoglycemia risk after late afternoon exercise with a nonexercise control day in adults with type 1 diabetes using automated insulin delivery (AID). Methods: Thirty adults with type 1 diabetes using AID (Minimed 670G) performed in random order 40 min high intensity interval aerobic exercise (HIE), resistance (RE), and moderate intensity aerobic exercise (MIE) exercise each separated by >1 week. The closed-loop set-point was temporarily increased 2 h pre-exercise and a snack eaten if plasma glucose was ≤126 mg/dL pre-exercise. Exercise commenced at ∼16:00. A standardized meal was eaten at ∼20:40. Hypoglycemic events were defined as a continuous glucose monitor (CGM) reading <70 mg/dL for ≥15 min. Four-hour postevening meal and overnight (00:00-06:00) CGM metrics for exercise were compared with the prior nonexercise day. Results: There was no severe hypoglycemia. Between 00:00 and 06:00, the proportion of nights with hypoglycemia did not differ postexercise versus control for HIE (18% vs. 11%; P = 0.688), RE (4% vs. 14%; P = 0.375), and MIE (7% vs. 14%; P = 0.625). Time in range (TIR) (70-180 mg/dL), >75% for all nights, did not differ between exercise conditions and control. Hypoglycemia episodes postmeal after exercise versus control did not differ for HIE (22% vs. 7%; P = 0.219) and MIE (10% vs. 14%; P > 0.999), but were greater post-RE (39% vs. 10%; P = 0.012). Conclusions: Overnight TIR was excellent with AID without increased hypoglycemia postexercise between 00:00 and 06:00 compared with nonexercise days. In contrast, hypoglycemia risk was increased after the first meal post-RE, suggesting the importance of greater vigilance and specific guidelines for meal-time dosing, particularly with vigorous RE. ACTRN12618000905268.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemia/prevenção & controle , Glicemia , Hipoglicemiantes/uso terapêutico , Exercício Físico , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina , Estudos Cross-Over
3.
Diabetes Technol Ther ; 24(2): 93-101, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34524022

RESUMO

Background: This study compared glucose control with fast-acting insulin aspart (FiAsp) versus insulin aspart following moderate-intensity exercise (MIE) and high-intensity exercise (HIE) using a second-generation closed-loop (CL) system in people with type 1 diabetes. Materials and Methods: This randomized crossover study compared FiAsp versus insulin aspart over four sessions during MIE and HIE with CL insulin delivery by the MiniMed™ Advanced hybrid CL system. Participants were randomly assigned FiAsp and insulin aspart each for 6 weeks and within each period performed, in random order, 40 min MIE (∼50% VO2max) and HIE (6 × 2 min ∼80% VO2max; 5 min recovery). The primary outcome was continuous glucose monitoring (CGM) time in range (TIR, 3.9-10.0 mM) for 24 h following exercise. Results: Sixteen adults (9 male; age 48 [37, 57] years; hemoglobin A1c (HbA1c) 7.0 [6.4, 7.2] %; duration diabetes 30 [17, 41] years) were recruited. In the 24 h postexercise, median TIR was >81%, time in hypoglycemia (<3.9 mM) was <4%, and time in hyperglycemia (>10 mM) was <17% for both exercise conditions and insulin formations, with no significant differences between insulins (P > 0.05). In the 2 h postexercise and overnight, the TIR approached 100% for all conditions. Conclusions: There were no differences in TIR during and 24 h after MIE or HIE when comparing insulin aspart with FiAsp delivered by a second-generation CL system. Insulin formulations with an offset in action greater than FiAsp are needed to provide a meaningful improvement in CL glucose control with exercise. Clinical Trial Registration number: ACTRN12619000469112.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina Aspart , Adulto , Glicemia , Automonitorização da Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Insulina Aspart/uso terapêutico , Masculino , Pessoa de Meia-Idade
4.
BMJ Open ; 8(8): e020275, 2018 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-30104309

RESUMO

INTRODUCTION: Automated insulin delivery (also known as closed loop, or artificial pancreas) has shown potential to improve glycaemic control and quality of life in people with type 1 diabetes (T1D). Automated insulin delivery devices incorporate an insulin pump with continuous glucose monitoring(CGM) and an algorithm, and adjust insulin in real time. This study aims to establish the safety and efficacy of a hybrid closed-loop (HCL) system in a long-term outpatient trial in people with T1D aged 12 -<25 years of age, and compare outcomes with standard therapy for T1D as used in the contemporary community. METHODS AND ANALYSIS: This is an open-label, multicentre, 6-month, randomised controlled home trial to test the MiniMed Medtronic 670G system (HCL) in people with T1D aged 12 -<25 years, and compare it to standard care (multiple daily injections or continuous subcutaneous insulin infusion (CSII), with or without CGM). Following a run-in period including diabetes and carbohydrate counting education, dosage optimisation and baseline glucose control data collection, participants are randomised to either HCL or to continue on their current treatment regimen. The primary aim of the study is to compare the proportion of time spent in target sensor glucose range (3.9-10.0 mmol/L) on HCL versus standard therapy. Secondary aims include a range of glucose control parameters, psychosocial measures, health economic measures, biomarker status, user/technology interactions and healthcare professional expectations. Analysis will be intention to treat. A study in adults with an aligned design is being conducted in parallel to this trial. ETHICS AND DISSEMINATION: Ethics committee permissions were gained from respective institutional review boards. The findings of the study will provide high-quality evidence on the role of HCL in clinical practice.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Adolescente , Glicemia/análise , Criança , Feminino , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Masculino , Adulto Jovem
5.
BMJ Open ; 8(7): e021435, 2018 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-30018097

RESUMO

INTRODUCTION: Optimal glycaemia can reduce type 2 diabetes (T2D) complications. Observing retrospective continuous glucose monitoring (r-CGM) patterns may prompt therapeutic changes but evidence for r-CGM use in T2D is limited. We describe the protocol for a randomised controlled trial (RCT) examining intermittent r-CGM use (up to 14 days every three months) in T2D in general practice (GP). METHODS AND ANALYSIS: General Practice Optimising Structured MOnitoring To achieve Improved Clinical Outcomes is a two-arm RCT asking 'does intermittent r-CGM in adults with T2D in primary care improve HbA1c?' PRIMARY OUTCOME: Absolute difference in mean HbA1c at 12 months follow-up between intervention and control arms. SECONDARY OUTCOMES: (a) r-CGM per cent time in target (4-10 mmol/L) range, at baseline and 12 months; (b) diabetes-specific distress (Problem Areas in Diabetes). ELIGIBILITY: Aged 18-80 years, T2D for ≥1 year, a (past month) HbA1c>5.5 mmol/mol (0.5%) above their individualised target while prescribed at least two non-insulin hypoglycaemic therapies and/or insulin (therapy stable for the last four months). Our general glycaemic target is 53 mmol/mol (7%) (patients with a history of severe hypoglycaemia or a recorded diagnosis of hypoglycaemia unawareness will have a target of 64 mmol/mol (8%)).Our trial compares r-CGM use and usual care. The r-CGM report summarising daily glucose patterns will be reviewed by GP and patient and inform treatment decisions. Participants in both arms are provided with 1 hour education by a specialist diabetes nurse.The sample (n=150/arm) has 80% power to detect a mean HbA1c difference of 5.5 mmol/mol (0.5%) with an SD of 14.2 (1.3%) and alpha of 0.05 (allowing for 10% clinic and 20% patient attrition). ETHICS AND DISSEMINATION: University of Melbourne Human Ethics Sub-Committee (ID 1647151.1). Dissemination will be in peer-reviewed journals, conferences and a plain-language summary for participants. TRIAL REGISTRATION NUMBER: >ACTRN12616001372471; Pre-results.


Assuntos
Automonitorização da Glicemia , Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Medicina Geral , Hemoglobinas Glicadas/metabolismo , Hipoglicemia/sangue , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto , Idoso , Feminino , Humanos , Hipoglicemia/prevenção & controle , Masculino , Pessoa de Meia-Idade , Formulação de Políticas , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...