1.
Pediatrics ; 153(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38469643

RESUMO

BACKGROUND AND OBJECTIVES: Neonatal endotracheal tube (ETT) size recommendations are based on limited evidence. We sought to determine data-driven weight-based ETT sizes for infants undergoing tracheal intubation and to compare these with Neonatal Resuscitation Program (NRP) recommendations. METHODS: Retrospective multicenter cohort study from an international airway registry. We evaluated ETT size changes (downsizing to a smaller ETT during the procedure or upsizing to a larger ETT within 7 days) and risk of procedural adverse outcomes associated with first-attempt ETT size selection when stratifying the cohort into 200 g subgroups. RESULTS: Of 7293 intubations assessed, the initial ETT was downsized in 5.0% of encounters and upsized within 7 days in 1.5%. ETT downsizing was most common when NRP-recommended sizes were attempted in the following weight subgroups: 1000 to 1199 g with a 3.0 mm (12.6%) and 2000 to 2199 g with a 3.5 mm (17.1%). For infants in these 2 weight subgroups, selection of ETTs 0.5 mm smaller than NRP recommendations was independently associated with lower odds of adverse outcomes compared with NRP-recommended sizes. Among infants weighing 1000 to 1199 g: any tracheal intubation associated event, 20.8% with 2.5 mm versus 21.9% with 3.0 mm (adjusted OR [aOR] 0.62, 95% confidence interval [CI] 0.41-0.94); severe oxygen desaturation, 35.2% with 2.5 mm vs 52.9% with 3.0 mm (aOR 0.53, 95% CI 0.38-0.75). Among infants weighing 2000 to 2199 g: severe oxygen desaturation, 41% with 3.0 mm versus 56% with 3.5mm (aOR 0.55, 95% CI 0.34-0.89). CONCLUSIONS: For infants weighing 1000 to 1199 g and 2000 to 2199 g, the recommended ETT size was frequently downsized during the procedure, whereas 0.5 mm smaller ETT sizes were associated with fewer adverse events and were rarely upsized.


Assuntos
Intubação Intratraqueal , Ressuscitação , Humanos , Recém-Nascido , Estudos de Coortes , Intubação Intratraqueal/métodos , Oxigênio
2.
Semin Fetal Neonatal Med ; 28(5): 101488, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000926

RESUMO

Opportunities to learn and maintain competence in neonatal intubation have decreased. As many clinicians providing care to the newborn infant are not skilled in intubation, alternative strategies are critical. Most preterm infants breathe spontaneously, and require stabilisation rather than resuscitation at birth. Use of tactile stimulation, deferred cord clamping, and avoidance of hypoxia can help optimise breathing for these infants. Nasal devices appear a promising alternative to the face mask for early provision of respiratory support. In term and near-term infants, supraglottic airways may be the most effective initial approach to resuscitation. Use of supraglottic airways during resuscitation can be taught to a range of providers, and may reduce need for intubation. While face mask ventilation is an important skill, it is challenging to perform effectively. Identification of the best approach to training the use of these devices during neonatal resuscitation remains an important priority.


Assuntos
Recém-Nascido Prematuro , Intubação Intratraqueal , Lactente , Recém-Nascido , Humanos , Ressuscitação , Máscaras , Respiração
3.
Arch Dis Child ; 109(1): 5-10, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-37438088

RESUMO

Although the majority of term infants will breathe spontaneously at birth, the requirement for advanced resuscitation can be unpredictable, as can the precipitous delivery of an extremely preterm infant in a non-tertiary neonatal unit. Infants born in hospitals without a tertiary neonatal intensive care unit have a higher mortality which is a disparity that has been difficult to resolve.Telemedicine, the use of videoconferencing software to connect those at the scene of a resuscitation to a remote clinician, can allow for real-time two-way communication between a local unit and a tertiary neonatal specialist. It has been present for some time in neonatology to provide secure video messaging with families and its use in neonatal acute care and resuscitation has been growing in recent years.We sought to perform a review of the current evidence available on the use of telemedicine in neonatal resuscitation. Studies demonstrate improved quality of resuscitation, improved adherence to resuscitation guidelines and positive experiences reported by local and tertiary teams. Suitable technology needs to be available to establish a rapid and secure video connection, as does adequate availability of experienced neonatologists to provide remote guidance. Telemedicine is an exciting and emerging tool which is being developed as a standard of care in units which have piloted it.


Assuntos
Serviços Médicos de Emergência , Neonatologia , Telemedicina , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Ressuscitação , Unidades de Terapia Intensiva Neonatal
6.
Arch Dis Child Fetal Neonatal Ed ; 107(3): 236-241, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33883207

RESUMO

This review examines the airway adjuncts currently used to acutely manage the neonatal airway. It describes the challenges encountered with facemask ventilation and intubation. Evidence is presented on how to optimise intubation safety and success rates with the use of videolaryngoscopy and attention to the intubation environment. The supraglottic airway (laryngeal mask airway) is emerging as a promising neonatal airway adjunct. It can be used effectively with little training to provide a viable alternative to facemask ventilation and intubation in neonatal resuscitation and be used as an alternative conduit for the administration of surfactant.


Assuntos
Máscaras Laríngeas , Laringoscópios , Surfactantes Pulmonares , Manuseio das Vias Aéreas , Humanos , Recém-Nascido , Intubação Intratraqueal , Surfactantes Pulmonares/uso terapêutico , Ressuscitação
7.
J Pediatr ; 236: 189-193.e2, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33940014

RESUMO

OBJECTIVE: To assess the first attempt neonatal intubation success rates of pediatric trainees following the implementation of an evidence-based training package. STUDY DESIGN: Data collection was undertaken from February, 1 2017, to January 31, 2018, to ascertain baseline preimplementation intubation success rates. An intubation training package, which included the use of videolaryngoscopy, preprocedure pause, and standardized instruction during the procedure, was introduced. Data on all subsequent intubations were collected prospectively from May 1, 2018, to April 30, 2020. RESULTS: Preimplementation baseline data over a 1-year period demonstrated overall first attempt intubation success rate of junior trainees to be 37% (33/89). After implementation of the training package, 290 intubations were analyzed over a 2-year period. The overall success rate was 67% (194/290); 61% (117/192) for junior trainees and 79% (77/98) for senior clinicians. Three or more attempts were required for 13% of intubations (38/290). During the study period, the overall number of intubations being carried out decreased. Intubations with the videolaryngoscope had higher success rates for all tiers of clinician, most marked in the junior tiers. CONCLUSIONS: The introduction of a standardized intubation training package, along with videolaryngoscopy, improved trainee intubation success rates.


Assuntos
Competência Clínica , Cuidados Críticos , Intubação Intratraqueal , Laringoscopia/educação , Pediatria/educação , Aprendizagem Baseada em Problemas/organização & administração , Humanos , Recém-Nascido , Internato e Residência , Gravação em Vídeo
8.
Arch Dis Child Fetal Neonatal Ed ; 106(3): 336-341, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32989046

RESUMO

Surfactant is an effective treatment for respiratory distress syndrome, being particularly important for infants in whom continuous positive airway pressure (CPAP) provides insufficient support. Supraglottic airway devices present an attractive option for surfactant delivery, particularly as an alternative to methods dependent on direct laryngoscopy, a procedural skill that is both difficult to learn and in which to maintain competence. Published studies provide encouraging data that surfactant administration by supraglottic airway device can be performed with a high rate of success and may reduce the need for subsequent intubation compared with either continued CPAP or surfactant administration via endotracheal tube. However, existing randomised controlled trials (RCTs) are heterogeneous in design and include just over 350 infants in total. To date, all RCT evidence has been generated in tertiary units, whereas the greatest potential for benefit from the use of these devices is likely to be in non-tertiary settings. Future research should investigate choice and utility of device in addition to safety and effectiveness of procedure. Importantly, studies conducted in non-tertiary settings should evaluate feasibility, meaningful clinical outcomes and the impact that this approach might have on infants and their families. Supraglottic airway devices may represent a simple and effective mode of surfactant administration that can be widely used by a variety of clinicians. However, further well-designed RCTs are required to determine their role, safety and effectiveness in both tertiary and non-tertiary settings before introduction into routine clinical practice.


Assuntos
Manuseio das Vias Aéreas , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Manuseio das Vias Aéreas/instrumentação , Manuseio das Vias Aéreas/métodos , Desenho de Equipamento , Humanos , Recém-Nascido
9.
Arch Dis Child Fetal Neonatal Ed ; 106(1): 57-61, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32611602

RESUMO

BACKGROUND: Evidence is lacking as to whether ambient light or phototherapy light could interfere with pulse oximeter performance. METHODS: In this randomised cross-over trial, we recruited neonates of gestation >24 weeks. Consented infants were randomly assigned to either pulse oximeter sensor with opaque wrap or without opaque wrap. Nellcor and Masimo sensors were applied simultaneously to different feet for 10 min of recording. Infants were crossed over to the other intervention for a further 10 min, totalling 20 min recording per infant. Primary outcome was faster acquisition of data with shielding of pulse oximeter sensor as compared with not shielding. RESULTS: A total of 96 babies were recruited. There was no difference in primary outcome of time taken to display valid data between the two groups (opaque wrap: 12.73±3.1 s vs no opaque wrap: 13.16±3.3 s, p=0.27). There was no difference in any of the secondary outcomes (percentage of valid data points, percentage of time saturation below target, and so on) between the two groups in both pulse oximeters. Masimo sensor readings displayed a higher mean oxygen saturation (mean difference of 2.85, p=0.001) and lower percentage of time saturation below 94% (mean difference of -27.8, p=0.001) than Nellcor in both groups. There was no difference in any of the outcomes in babies receiving phototherapy (n=21). CONCLUSION: In this study, shielding the pulse oximeter sensor from ambient light or phototherapy light did not yield faster data acquisition or better data quality. TRIAL REGISTRATION NUMBER: ISRCTN10302534.


Assuntos
Iluminação , Oximetria/métodos , Estudos Cross-Over , Feminino , Humanos , Recém-Nascido , Masculino , Fototerapia/métodos
11.
Arch Dis Child Fetal Neonatal Ed ; 106(2): 168-171, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32963087

RESUMO

INTRODUCTION: Neonatal intubation is a challenging skill to acquire. A randomised controlled trial (RCT) found junior trainees had higher intubation success rates if their supervisor shared their airway view on a videolaryngoscope screen compared with intubations where the supervisor could not see the videolaryngoscope screen. The intubations in the trial were supervised by a group of experienced neonatologists who developed an intubation teaching package that aimed to be informative, consistent and supportive. We surveyed the trainees to assess their experiences of the intubation attempts. METHODS: Trainees participating in the RCT completed questionnaires anonymously after each intubation attempt. Questionnaires used 5-point Likert scales and free comment sections. Quantitative analysis was performed using descriptive statistics. In a qualitative analysis, free comments were coded to identify central recurring themes. RESULTS: Two hundred and six questionnaires were completed by 36 trainees. The majority reported that the guidance received during intubation was helpful, the postprocedure feedback was educational and their confidence levels were increased. Trainees appreciated a controlled environment and calm, consistent guidance. They found intubations in the delivery room, those involving unstable infants, large audiences and parental presence more stressful. Responses were positive whether the videolaryngoscope screen was visible or covered, emphasising the importance of consistent guidance. Overall, 16% of intubations were reported as intimidating. CONCLUSION: The shared airway view offered by videolaryngoscopy was well received. In addition, taking measures to control the setting, with standardised guidance and feedback, improved confidence and created a more positive learning experience.


Assuntos
Intubação Intratraqueal/métodos , Laringoscopia/educação , Laringoscopia/métodos , Competência Clínica , Humanos , Recém-Nascido
14.
Arch Dis Child Fetal Neonatal Ed ; 105(1): 94-97, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30606750

RESUMO

Neonatal intubation is an essential but difficult skill to learn. Videolaryngoscopy allows the airway view to be shared by the intubator and supervisor and improves intubation success. Ideally, a videolaryngoscope (VL) should be usable as a conventional laryngoscope (CL). The aims of this report were to describe differences in the shape of currently available CL and VL blades and to compare the direct airway view obtainable on a neonatal manikin with different laryngoscope blades.Three main differences were observed; compared with CL, the VL blades have a reduced vertical height, a curved tip and curved body. The direct airway view obtained by the VL is narrower than that obtained with the CL, although the corresponding view on the VL screen is maintained.Minor adaptation of intubation technique may be required when using a VL. Modifying VL blades to reduce these differences may improve their usefulness as an intubation training tool.


Assuntos
Laringoscópios , Laringoscopia/instrumentação , Gravação em Vídeo , Desenho de Equipamento , Humanos , Recém-Nascido , Intubação Intratraqueal , Laringoscopia/educação , Manequins
15.
Resuscitation ; 134: 91-98, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30572069

RESUMO

AIM: Facial measurements of preterm infants indicate that standard diameter facemasks used during positive pressure ventilation are too large, which may lead to mask leak and compromise resuscitation. We aimed to determine whether the use of a facemask that better complies with the dimensions of preterm faces, compared with a standard facemask, reduces facemask leak. METHODS: Parallel group, randomised controlled trial. Preterm infants ≤32 weeks' gestation receiving facemask ventilation prior to intubation in the neonatal intensive care unit, and those 28-32+6 weeks' receiving facemask ventilation in the delivery room were eligible. Infants were randomised to receive ventilation via a standard (50mm) (control), or a smaller (35mm or 42mm) diameter facemask (intervention), stratified by gestation (≤26 weeks'; 35mm, 27-32+6; 42mm). The primary outcome was leak between the mask and the infants face. RESULTS: Of 298 eligible infants, 139 were randomised and 131 were included in the final analysis; 66 in the intervention group and 65 in the control group. The median (IQR) leak was 42% (13-69%) in the intervention group compared with 39% (22-66%) in the control group P=0.43. The median (IQR) lowest oxygen saturation was similar in both groups [intervention 70% (34-93%) vs. control 71% (40-93%) P=0.75]. One infant crossed over from the intervention to the control group due to poor response to ventilation with the intervention facemask. CONCLUSIONS: Smaller facemasks did not reduce mask leak in preterm facemask ventilation. All facemasks had high leak, particularly in infants ≤26 weeks' gestation. CLINICAL TRIAL REGISTRATION: This trial is registered with the Australian New Zealand Clinical Trials Registry, ACTRN12614000709640, www.anzctr.org.au.


Assuntos
Máscaras , Respiração com Pressão Positiva/métodos , Face/anatomia & histologia , Feminino , Idade Gestacional , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Masculino , Respiração com Pressão Positiva/normas , Método Simples-Cego
16.
Arch Dis Child Fetal Neonatal Ed ; 103(5): F408-F412, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29127153

RESUMO

OBJECTIVES: Neonatal intubation is a difficult skill to learn and teach. If an attempt is unsuccessful, the intubator and instructor often cannot explain why. This study aims to review videolaryngoscopy recordings of unsuccessful intubations and explain the reasons why attempts were not successful. STUDY DESIGN: This is a descriptive study examining videolaryngoscopy recordings obtained from a randomised controlled trial that evaluated if neonatal intubation success rates of inexperienced trainees were superior if they used a videolaryngoscope compared with a laryngoscope. All recorded unsuccessful intubations were included and reviewed independently by two reviewers blinded to study group. Their assessment was correlated with the intubator's perception as reported in a postintubation questionnaire. The Cormack-Lehane classification system was used for objective assessment of laryngeal view. RESULTS: Recordings and questionnaires from 45 unsuccessful intubations were included (15 intervention and 30 control). The most common reasons for an unsuccessful attempt were oesophageal intubation and failure to recognise the anatomy. In 36 (80%) of intubations, an intubatable view was achieved but was then either lost, not recognised or there was an apparent inability to correctly direct the endotracheal tube. Suctioning was commonly performed but rarely improved the view. CONCLUSIONS: Lack of intubation success was most commonly due to failure to recognise midline anatomical structures. Trainees need to be taught to recognise the uvula and epiglottis and use these landmarks to guide intubation. Excessive secretions are rarely a factor in elective and premedicated intubations, and routine suctioning should be discouraged. Better blade design may make it easier to direct the tube through the vocal cords.


Assuntos
Competência Clínica/normas , Intubação Intratraqueal , Laringoscopia , Neonatologia , Feminino , Humanos , Recém-Nascido , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Laringoscópios , Laringoscopia/efeitos adversos , Laringoscopia/educação , Laringoscopia/métodos , Masculino , Avaliação das Necessidades , Neonatologia/educação , Neonatologia/métodos , Melhoria de Qualidade , Falha de Tratamento , Gravação em Vídeo/métodos
17.
Arch Dis Child Fetal Neonatal Ed ; 103(1): F66-F71, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29079652

RESUMO

This review examines devices used during newborn stabilisation. Evidence for their use to optimise the thermal, respiratory and cardiovascular management in the delivery room is presented. Mechanisms of action and rationale of use are described, current developments are presented and areas of future research are highlighted.


Assuntos
Salas de Parto/organização & administração , Equipamentos e Provisões/classificação , Parto , Assistência Perinatal/métodos , Humanos , Recém-Nascido
18.
Cochrane Database Syst Rev ; 6: CD011791, 2017 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-28640930

RESUMO

BACKGROUND: Neonatal endotracheal intubation is a common and potentially life-saving intervention. It is a mandatory skill for neonatal trainees, but one that is difficult to master and maintain. Intubation opportunities for trainees are decreasing and success rates are subsequently falling. Use of a stylet may aid intubation and improve success. However, the potential for associated harm must be considered. OBJECTIVES: To compare the benefits and harms of neonatal orotracheal intubation with a stylet versus neonatal orotracheal intubation without a stylet. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library; MEDLINE; Embase; the Cumulative Index to Nursing and Allied Health Literature (CINAHL), and previous reviews. We also searched cross-references, contacted expert informants, handsearched journals, and looked at conference proceedings. We searched clinical trials registries for current and recently completed trials. We conducted our most recent search in April 2017. SELECTION CRITERIA: All randomised, quasi-randomised, and cluster-randomised controlled trials comparing use versus non-use of a stylet in neonatal orotracheal intubation. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed results of searches against predetermined criteria for inclusion, assessed risk of bias, and extracted data. We used the standard methods of the Cochrane Collaboration, as documented in the Cochrane Handbook for Systemic Reviews of Interventions, and of the Cochrane Neonatal Review Group. MAIN RESULTS: We included a single-centre non-blinded randomised controlled trial that reported a total of 302 intubation attempts in 232 infants. The median gestational age of enrolled infants was 29 weeks. Paediatric residents and fellows performed the intubations. We judged the study to be at low risk of bias overall. Investigators compared success rates of first-attempt intubation with and without use of a stylet and reported success rates as similar between stylet and no-stylet groups (57% and 53%) (P = 0.47). Success rates did not differ between groups in subgroup analyses by provider level of training and infant weight. Results showed no differences in secondary review outcomes, including duration of intubation, number of attempts, participant instability during the procedure, and local airway trauma. Only 25% of all intubations took less than 30 seconds to perform. Study authors did not report neonatal morbidity nor mortality. We considered the quality of evidence as low on GRADE analysis, given that we identified only one unblinded study. AUTHORS' CONCLUSIONS: Current available evidence suggests that use of a stylet during neonatal orotracheal intubation does not significantly improve the success rate among paediatric trainees. However, only one brand of stylet and one brand of endotracheal tube have been tested, and researchers performed all intubations on infants in a hospital setting. Therefore, our results cannot be generalised beyond these limitations.


Assuntos
Intubação Intratraqueal/métodos , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/estatística & dados numéricos , Pediatria/estatística & dados numéricos
19.
Cochrane Database Syst Rev ; 3: CD011065, 2017 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-28284020

RESUMO

BACKGROUND: Tongue-tie, or ankyloglossia, is a condition whereby the lingual frenulum attaches near the tip of the tongue and may be short, tight and thick. Tongue-tie is present in 4% to 11% of newborns. Tongue-tie has been cited as a cause of poor breastfeeding and maternal nipple pain. Frenotomy, which is commonly performed, may correct the restriction to tongue movement and allow more effective breastfeeding with less maternal nipple pain. OBJECTIVES: To determine whether frenotomy is safe and effective in improving ability to feed orally among infants younger than three months of age with tongue-tie (and problems feeding).Also, to perform subgroup analysis to determine the following.• Severity of tongue-tie before frenotomy as measured by a validated tool (e.g. Hazelbaker Assessment Tool for Lingual Frenulum Function (ATLFF) scores < 11; scores ≥ 11) (Hazelbaker 1993).• Gestational age at birth (< 37 weeks' gestation; 37 weeks' gestation and above).• Method of feeding (breast or bottle).• Age at frenotomy (≤ 10 days of age; > 10 days to three months of age).• Severity of feeding difficulty (infants with feeding difficulty affecting weight gain (as assessed by infant's not regaining birth weight by day 14 or falling off centiles); infants with symptomatic feeding difficulty but thriving (greater than birth weight by day 14 and tracking centiles). SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase and CINAHL up to January 2017, as well as previous reviews including cross-references, expert informants and journal handsearching. We searched clinical trials databases for ongoing and recently completed trials. We applied no language restrictions. SELECTION CRITERIA: Randomised, quasi-randomised controlled trials or cluster-randomised trials that compared frenotomy versus no frenotomy or frenotomy versus sham procedure in newborn infants. DATA COLLECTION AND ANALYSIS: Review authors extracted from the reports of clinical trials data regarding clinical outcomes including infant feeding, maternal nipple pain, duration of breastfeeding, cessation of breastfeeding, infant pain, excessive bleeding, infection at the site of frenotomy, ulceration at the site of frenotomy, damage to the tongue and/or submandibular ducts and recurrence of tongue-tie. We used the GRADE approach to assess the quality of evidence. MAIN RESULTS: Five randomised trials met our inclusion criteria (n = 302). Three studies objectively measured infant breastfeeding using standardised assessment tools. Pooled analysis of two studies (n = 155) showed no change on a 10-point feeding scale following frenotomy (mean difference (MD) -0.1, 95% confidence interval (CI) -0.6 to 0.5 units on a 10-point feeding scale). A third study (n = 58) showed objective improvement on a 12-point feeding scale (MD 3.5, 95% CI 3.1 to 4.0 units of a 12-point feeding scale). Four studies objectively assessed maternal pain. Pooled analysis of three studies (n = 212) based on a 10-point pain scale showed a reduction in maternal pain scores following frenotomy (MD -0.7, 95% CI -1.4 to -0.1 units on a 10-point pain scale). A fourth study (n = 58) also showed a reduction in pain scores on a 50-point pain scale (MD -8.6, 95% CI -9.4 to -7.8 units on a 50-point pain scale). All studies reported no adverse effects following frenotomy. These studies had serious methodological shortcomings. They included small sample sizes, and only two studies blinded both mothers and assessors; one did not attempt blinding for mothers nor for assessors. All studies offered frenotomy to controls, and most controls underwent the procedure, suggesting lack of equipoise. No study was able to report whether frenotomy led to long-term successful breastfeeding. AUTHORS' CONCLUSIONS: Frenotomy reduced breastfeeding mothers' nipple pain in the short term. Investigators did not find a consistent positive effect on infant breastfeeding. Researchers reported no serious complications, but the total number of infants studied was small. The small number of trials along with methodological shortcomings limits the certainty of these findings. Further randomised controlled trials of high methodological quality are necessary to determine the effects of frenotomy.


Assuntos
Anquiloglossia/cirurgia , Aleitamento Materno , Freio Lingual/cirurgia , Aleitamento Materno/efeitos adversos , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Mastodinia/etiologia , Mamilos , Medição da Dor , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Arch Dis Child Fetal Neonatal Ed ; 101(4): F294-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25862726

RESUMO

OBJECTIVE: International guidelines recommend that an appropriately sized face mask for providing positive pressure ventilation should cover the mouth and nose but not the eyes and should not overlap the chin. This study aimed to measure the dimensions of preterm infants' faces and compare these with the size of the most commonly available face masks (external diameter 50 mm) and the smallest masks available (external diameters 35 and 42 mm). METHODS: Infants 24-33 weeks' postmenstrual age (PMA) were photographed in a standardised manner. Images were analysed using ImageJ software (National Institute of Health, USA) to calculate the distance from the nasofrontal groove to the mental protuberance. This facial measurement corresponds to the external diameter of an optimally fitting mask. RESULTS: A cohort of 107 infants between 24 and 33 weeks' gestational age, including at least 10 infants per week of gestation, was photographed within 72 h after birth and weekly until 33 weeks' PMA. 347 photographs were analysed. Infants of 24, 26, 28, 30 and 32 weeks' PMA had mean (SD) facial measurements of 32 (2), 36 (3), 38 (4), 41 (2) and 43 (4) mm, respectively. There were no significant differences when examined by gender or when small for gestational age infants were excluded. CONCLUSIONS: The smallest size of some brands of mask is too large for many preterm infants. Masks of 35 mm diameter are suitable for infants <29 weeks' PMA or 1000 g. Masks of 42 mm diameter are suitable for infants 27-33 weeks' PMA or 750-2500 g.


Assuntos
Pesos e Medidas Corporais/métodos , Face , Máscaras/normas , Respiração com Pressão Positiva/instrumentação , Desenho Assistido por Computador , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Unidades de Terapia Intensiva Neonatal/normas , Masculino , Respiração com Pressão Positiva/métodos , Qualidade da Assistência à Saúde
SELEÇÃO DE REFERÊNCIAS