Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 30(7): 1026-1035, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30977168

RESUMO

INTRODUCTION: Procedural atrial fibrillation (AF) termination is considered as a predictor of long-term success after catheter ablation for persistent AF (persAF). However, some patients remain free of arrhythmia recurrences despite failure to achieve AF termination. The objective of this study was to assess long-term outcome and prognostic factors in patients undergoing complex ablation without procedural AF termination. METHODS AND RESULTS: This study comprised 419 patients (63.8 ± 10.2 years, 63.4% male) undergoing complex ablation for persAF. Patients without procedural AF termination (n = 137, 64.2 ± 9.7 years, 63.5% male) were categorized into patients who remained in sinus rhythm (SR) in long-term outcome (SR-group) and patients with recurrence of AF or atrial tachycardia (AT) (AR-group). During a follow-up (FU) of 19.6 ± 14.6 months, the SR-group consisted of 65 (47.5%) and the AR-group of 69 (50.4%) patients. Three patients (2.2%) were lost to FU. Left atrial appendage (LAA) flow velocity and left atrium volume index (LAVI) could be identified as predictors for long-term success. LAA flow velocity and baseline AF cycle length (AFCL) were significantly associated with the type of arrhythmia recurrence (AF vs AT), ie, higher values of both are predictive for AT rather than AF recurrences. Patients with a LAVI < 34.4 mL/m² and significant AFCL increase during the ablation procedure had rather AT than AF recurrences. CONCLUSION: Patients with an arrhythmia-free outcome despite failure of procedural AF termination during complex ablation for persAF are characterized by specific morphological and functional properties that are easy to obtain.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
2.
Europace ; 19(7): 1204-1210, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27742774

RESUMO

AIMS: Different cardiac arrhythmias have been suggested to be associated with Danon disease, e.g. Wolff-Parkinson-White syndrome. However, a systematic electrophysiological investigation of patients with Danon disease is lacking thus far. METHODS AND RESULTS: Seven patients with Danon disease (4 males, 35.8 ± 10.8 years; 3 females, 51.3 ± 19.9 years) from 3 different families were studied. In all patients, the presence of Danon disease was confirmed by western blot of biopsy material or genetic testing. The patients were characterized by 12-lead electrocardiogram (ECG), Holter ECG, echocardiography, and serial implantable cardioverter defibrillator (ICD) interrogations (in ICD recipients). All male patients underwent electrophysiological investigation (EP study). Asymptomatic ventricular tachyarrhythmias were documented in six of the seven patients. Moreover, 5 of the 7 patients suffered from atrial fibrillation (AF), with 1 of them experiencing thromboembolic stroke at the age of 30 years. In male patients, the initial QRS complex was characterized by a slurring upstroke and shortened PQ interval mimicking ventricular pre-excitation. One male patient showed initial QRS complex slurring with prolonged PR interval. However, the presence of an accessory pathway was excluded by an EP study in all patients. In female patients, initial QRS complex slurring was significantly less distinct. In four patients, ICD implantation was performed for primary prevention of sudden cardiac death. However, sustained ventricular arrhythmias were not documented in any of the patients. CONCLUSIONS: The present study indicates that the distinct surface ECG pattern in Danon disease is not associated with ventricular pre-excitation. Atrial fibrillation is frequently observed in these patients and may be associated with thromboembolic events in the young, while sustained ventricular arrhythmias occur less frequently than previously reported.


Assuntos
Arritmias Cardíacas/etiologia , Doença de Depósito de Glicogênio Tipo IIb/complicações , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Nó Atrioventricular/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ecocardiografia , Cardioversão Elétrica/instrumentação , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Doença de Depósito de Glicogênio Tipo IIb/diagnóstico , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária/instrumentação , Fatores de Risco , Fatores de Tempo
3.
J Cardiovasc Electrophysiol ; 26(12): 1289-94, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26303513

RESUMO

INTRODUCTION: Persistent atrial fibrillation (persAF) can occur either as a sustained arrhythmia that has progressed from initially paroxysmal AF or as primary persAF without a history of any spontaneously terminated episode. There is a paucity of data differentiating between the 2 different persAF entities. Thus, we prospectively evaluated baseline characteristics, electrophysiological features, and ablation outcome in these 2 patient cohorts. METHODS AND RESULTS: A total number of 154 consecutive persAF patients (63 ± 10 years, f = 42, longstanding persAF = 60) were characterized in terms of having primary persAF (P-persAF group) or persAF that secondarily progressed from paroxysmal AF (S-persAF group). All patients underwent de novo catheter ablation using the stepwise approach. PersAF entities were characterized by detailed patient history, sequential Holter monitoring, and reports of documented modes of AF conversion, respectively. The P-persAF group had a higher number of young patients (<50 years), a shorter AF history, and a higher number of congestive heart failure. The HATCH score did not differ between the groups. Procedural AF termination rate was significantly higher in S-persAF than in P-persAF patients (n = 55 [81%] vs. n = 58 [68%], P = 0.043). At 1-year follow-up, the arrhythmia-free survival after a single procedure was significantly lower in patients with P-persAF (26% vs. 43%, P = 0.016). Categorization to P-persAF was the strongest independent predictor of arrhythmia recurrence. CONCLUSIONS: P-persAF seems to be a specific arrhythmia entity that is associated with a lower AF-termination rate and a worse outcome after catheter ablation as compared to S-persAF.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter , Idoso , Fibrilação Atrial/classificação , Estudos de Coortes , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
4.
Herzschrittmacherther Elektrophysiol ; 26(3): 208-13, 2015 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-26260681

RESUMO

INTRODUCTION: Atrial tachycardia in virtually all areas of both atria has become more important in the clinical management of patients with previous complex atrial fibrillation ablation. Accurate interpretation of surface electrocardiogram (ECG) characteristics is of paramount importance to localize the origin of atrial tachycardia, particularly for planning interventional treatment. This article highlights the ECG features of different types of right and left atrial tachycardia. DEFINITION: Typical right atrial flutter through the cavotricuspid isthmus conducts septally in a cranial direction and demonstrates sawtooth-like flutter waves which start negative in II, III and aVF and then show a steep slope upwards to the isoelectric line. The flutter rate typically ranges between 240-250 beats/min. In contrast, right atrial flutter in a clockwise rotation, flutter around the vena cava inferior or superior and around a scar (e.g. after cardiac surgery) show positive or biphasic flutter waves (lower or upper loop reentry). Left atrial flutter waves (e.g. around the mitral valve or around the pulmonary veins) are very heterogeneous and are typically positive in V1 as the left atrium is located in the posterior mediastinum. CONCLUSION: Specific knowledge of flutter wave morphology in surface ECG facilitates planning and performance of the ablation strategy.


Assuntos
Flutter Atrial/classificação , Flutter Atrial/diagnóstico , Eletrocardiografia/métodos , Átrios do Coração , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Circ Arrhythm Electrophysiol ; 8(5): 1080-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26297786

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. METHODS AND RESULTS: A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting extra-PV AF sources with the desired procedural end point of termination to sinus rhythm. Primary study end point was freedom from arrhythmia during 1-year follow-up. In group A, adenosine provoked dormant conduction in 31 (41%) patients with a mean of 1.6±0.8 transiently recovered PVs per patient. Termination of AF during PVI was observed in 31 (65%) patients, whereas AF persisted afterward in 17 (35%) patients. AF termination occurred in 13 (76%) patients by AF source ablation. After 1-year follow-up, significantly more group B patients were free of arrhythmia recurrences (87 versus 68%; P=0.006). During redo ablation, the rate of PV reconduction did not differ between both groups (group A: 55% versus group B: 61%; P=0.25). CONCLUSIONS: Elimination of extra-PV AF sources after PVI is superior to sole PV isolation with the adjunct of abolishing potential dormant conduction. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02238392.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Adenosina/administração & dosagem , Idoso , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 26(9): 956-962, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26062031

RESUMO

INTRODUCTION: Open irrigated radiofrequency (RF) ablation catheters with a porous tip (56 holes, TC-SF) permit delivering RF energy in a temperature-controlled mode without temperature rise. This prospective observational study investigated the association of different catheter parameters on the occurrence of audible steam pops during left atrial (LA) ablation. METHODS AND RESULTS: A total of 226 patients underwent TC-SF catheter ablation for atrial fibrillation. RF power delivery, impedance and catheter tip temperature were continually recorded throughout the ablation. Pulmonary vein isolation was performed with a maximum of 27 W and LA electrogram-guided or linear ablation with a maximum of 30 W. A total of 59 audible steam pops occurred, 2 of them resulting in pericardial tamponade. In the initial 89 patients, with an irrigation flow rate of 10 mL/min, 18 steam pops with one tamponade occurred in 12 (14%) patients. Subsequently, the irrigation flow rate was increased to 20 mL/min in the following 137 patients, resulting in the occurrence of 41 steam pops including one case of tamponade in a total of 30 (22%) patients. The maximal power was significantly higher in RF applications associated with a pop than those that did not. In only 12 (20%) steam pops, a significant impedance change occurred immediately before pop occurrence (4 [7%] impedance rise >10 ohm, 8 [13%] impedance drop >15 ohm). CONCLUSIONS: The TC-SF catheter does not provide sufficient feedback from the ablated tissue to prevent steam popping.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...