Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 28: e936335, 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35831982

RESUMO

BACKGROUND Oxidative stress is a disruption of the pro-oxidative-antioxidant balance, caused by excessive production or ineffective removal of reactive oxygen species. MATERIAL AND METHODS The study included 42 male patients aged 38 to 69 years. The first group consisted of 21 men with osteoarthritis after primary hip arthroplasty using the Smith & Nephew Birmingham Hip Resurfacing implant. The second group included 21 men after hip arthroplasty using the femoral neck SPIRON K-implant. In both groups, concentrations of ions, the antioxidant system in the blood, and parameters of oxidative stress were evaluated twice. Clinical assessment using the Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, and Short Form (12) Health Survey (SF-12) scales was performed. RESULTS Concentrations of metal ions in the blood and the level of oxidative stress were significantly higher in the resurfacing group than in the femoral neck arthroplasty group. The response of the antioxidant system was significantly greater in the femoral neck arthroplasty group. During clinical evaluation, groups did not show significant differences, with the exception of greater shortening of the operated limb and a lower score in the mental-sphere of the SF-12 scale in the resurfacing arthroplasty group. CONCLUSIONS Resurfacing hip arthroplasty increased oxidative stress, increased the concentration of metal ions, and did not affect alignment of the abbreviation of the operated limb. A significant improvement in the quality of life of patients in the mental sphere according to the SF-12 occurred after the application of resurfacing arthroplasty, in the first month after the procedure.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite , Antioxidantes , Artroplastia de Quadril/métodos , Colo do Fêmur/cirurgia , Humanos , Íons , Masculino , Metais , Osteoartrite/cirurgia , Desenho de Prótese , Qualidade de Vida , Resultado do Tratamento
2.
Medicine (Baltimore) ; 101(4): e28475, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35089189

RESUMO

RATIONALE: Resurfacing arthroplasty using the J&J DePuy ASR system was withdrawn from surgical treatment due to the necessity of frequent revision procedures after its application. There have been many studies concerning treatment of acetabular bone loss using different operating techniques. However, we felt that data of custom - made implant usage in such cases is highly insufficient, and there is lack of evidence on its application in treatment of loosening of the previous implant. The aim of the study was to evaluate the effectiveness of surgical treatment with a custom-made implant in a patient with extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&J DePuy ASR surface prosthesis in the early period of observation. PATIENT CONCERNS: A 74-year-old patient was taken to the Orthopaedic Trauma Emergency Room due to increasing pain in the right hip for about 3 months. Nine years earlier he underwent resurfacing arthroplasty of the right hip using the J&J DePuy ASR method. DIAGNOSES: The imaging diagnostics (X-ray, computed tomography, ultrasound) revealed the presence of a pseudotumor and lysis around the acetabular implant, which caused a fracture in the acetabulum. INTERVENTIONS: Revision arthroplasty of the right hip joint was performed with the removal of the ASR implant. During the procedure extensive bone defects were visualized, preventing the insertion of the revision acetabulum. After extensive plasticization of the defects with the use of allogeneic cancellous chips the "hanging hip" was left with the intention of making another attempt to insert the implant after the reconstitution of the acetabular bone. A computed tomography examination 2.5 years after the ASR removal revealed the lack of an adequate degree of bone remodeling for the planned implant. Arthroplasty using custom - made aMace Acetabular Revision System by Materialize was performed 3 years after the removal of ASR. OUTCOMES: Optimal implant adherence to the bone base and full osseointegration with the pelvic bone bearing has been achieved. Significant improvement in clinical parameters has been noted, with no complications in the postoperative period. LESSONS: The use of an individual custom-made implant in extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&J DePuy ASR surface prosthesis in patients is an effective method of surgical treatment.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Reoperação , Acetábulo/cirurgia , Idoso , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Tomografia Computadorizada por Raios X
3.
Ortop Traumatol Rehabil ; 20(1): 31-42, 2018 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-30152760

RESUMO

Computed tomography is a modern technique producing high quality image of scanned organs. It plays a significant role in diagnostic work-up on orthopedics wards. This paper presents an analysis of management of two cases of Hawkins type I talar neck fracture with ankle joint rotation. In both patients, the diagnosis was based on conventional radiographs of the ankle joint in two projections and was subsequently verified with CT scans. The findings of a CT scan of the talus had a significant impact on further treatment and physiotherapy. Non-surgical treatment consisting in immobilization with a short leg cast combined with medication and magnetic field therapy produced a positive therapeutic outcome. A follow-up CT scan of the talus revealed bone union with remodelling in both patients. The functional outcome according to the AOFAS scale should be regarded good. Computed tomography is the radiological modality for detecting talar neck fractures and determining the presence of displacement. Follow-up CT scans evaluate the natural process of bone healing, which is crucial for treatment decisions regarding weight-bearing status. A correct diagnosis based on CT helps to prevent the development of necrosis and posttraumatic (secondary) degenerative changes as well as advanced physical disability, especially among youn-ger patients, in whom the injury is most common, consequently helping to avoid a long and costly treatment.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Tálus/lesões , Tálus/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tálus/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Pol Merkur Lekarski ; 33(198): 346-8, 2012 Dec.
Artigo em Polonês | MEDLINE | ID: mdl-23437706

RESUMO

Paracetamol (Acetaminophen, PC) is metabolized in liver to N-acetyl-p-benzoquinon-imine (NAPQI), that is in turn conjugated by glutathione S-transferase with glutathione. NAPQI inhibits the respiratory chain. It may cause a 90% decrease of ATP concentration in mitochondria of hepatocytes. The oxidation of paracetamol to quinine form can also generate free radicals. Both above mentioned processes, can injure the mitochondria and cells. There have not been found in accessible literature any data dealing with paracetamol influence on the process elimination of the alpha nitrogen in the liver. The ATP concentration decline may lead to disturbances in mitochondrial enzymes. There are discrepant data of the role of free radicals in the mechanism of toxic action of paracetamol.


Assuntos
Acetaminofen/metabolismo , Acetaminofen/toxicidade , Fígado/metabolismo , Trifosfato de Adenosina/metabolismo , Animais , Fígado/efeitos dos fármacos , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Nitrogênio/metabolismo , Estresse Oxidativo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...