Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 38(4): 218-25, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24711295

RESUMO

Cyanide causes toxic effects by inhibiting cytochrome c oxidase, resulting in cellular hypoxia and cytotoxic anoxia, and can eventually lead to death. Cyanide exposure can be verified by direct analysis of cyanide concentrations or analyzing its metabolites, including thiocyanate (SCN(-)) and 2-amino-2-thiazoline-4-carboxylic acid (ATCA) in blood. To determine the behavior of these markers following cyanide exposure, a toxicokinetics study was performed in three animal models: (i) rats (250-300 g), (ii) rabbits (3.5-4.2 kg) and (iii) swine (47-54 kg). Cyanide reached a maximum in blood and declined rapidly in each animal model as it was absorbed, distributed, metabolized and eliminated. Thiocyanate concentrations rose more slowly as cyanide was enzymatically converted to SCN(-). Concentrations of ATCA did not rise significantly above the baseline in the rat model, but rose quickly in rabbits (up to a 40-fold increase) and swine (up to a 3-fold increase) and then fell rapidly, generally following the relative behavior of cyanide. Rats were administered cyanide subcutaneously and the apparent half-life (t1/2) was determined to be 1,510 min. Rabbits were administered cyanide intravenously and the t1/2 was determined to be 177 min. Swine were administered cyanide intravenously and the t1/2 was determined to be 26.9 min. The SCN(-) t1/2 in rats was 3,010 min, but was not calculated in rabbits and swine because SCN(-) concentrations did not reach a maximum. The t1/2 of ATCA was 40.7 and 13.9 min in rabbits and swine, respectively, while it could not be determined in rats with confidence. The current study suggests that cyanide exposure may be verified shortly after exposure by determining significantly elevated cyanide and SCN(-) in each animal model and ATCA may be used when the ATCA detoxification pathway is significant.


Assuntos
Cianetos/farmacocinética , Tiazóis/sangue , Tiocianatos/sangue , Animais , Biomarcadores/sangue , Cianetos/sangue , Cianetos/metabolismo , Meia-Vida , Inativação Metabólica , Injeções Intravenosas , Injeções Subcutâneas , Masculino , Coelhos , Ratos Sprague-Dawley , Especificidade da Espécie , Sus scrofa , Toxicocinética
2.
Anal Chem ; 86(3): 1845-52, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24383576

RESUMO

Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating, and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Because the onset of cyanide toxicity is fast, a rapid, sensitive, and accurate method for the diagnosis of cyanide exposure is necessary. Therefore, a field sensor for the diagnosis of cyanide exposure was developed based on the reaction of naphthalene dialdehyde, taurine, and cyanide, yielding a fluorescent ß-isoindole. An integrated cyanide capture "apparatus", consisting of sample and cyanide capture chambers, allowed rapid separation of cyanide from blood samples. Rabbit whole blood was added to the sample chamber, acidified, and the HCN gas evolved was actively transferred through a stainless steel channel to the capture chamber containing a basic solution of naphthalene dialdehyde (NDA) and taurine. The overall analysis time (including the addition of the sample) was <3 min, the linear range was 3.13-200 µM, and the limit of detection was 0.78 µM. None of the potential interferents investigated (NaHS, NH4OH, NaSCN, and human serum albumin) produced a signal that could be interpreted as a false positive or a false negative for cyanide exposure. Most importantly, the sensor was 100% accurate in diagnosing cyanide poisoning for acutely exposed rabbits.


Assuntos
Técnicas de Química Analítica/instrumentação , Cianetos/sangue , Exposição Ambiental/análise , Métodos Analíticos de Preparação de Amostras , Animais , Cianetos/toxicidade , Coelhos , Espectrometria de Fluorescência
3.
Anal Bioanal Chem ; 406(3): 727-34, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24327078

RESUMO

An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na(13)C(15)N and NaS(13)C(15)N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1-50 and 0.2-50 µM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão , Cianetos/sangue , Espectrometria de Massas , Tiocianatos/sangue , Animais , Estabilidade de Medicamentos , Limite de Detecção , Estrutura Molecular , Controle de Qualidade , Reprodutibilidade dos Testes , Suínos , Fatores de Tempo
4.
Anal Bioanal Chem ; 404(8): 2287-94, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22941221

RESUMO

An analytical method utilizing chemical ionization gas chromatography-mass spectrometry was developed for the simultaneous determination of cyanide and thiocyanate in plasma. Sample preparation for this analysis required essentially one-step by combining the reaction of cyanide and thiocyanate with pentafluorobenzyl bromide and simultaneous extraction of the product into ethyl acetate facilitated by a phase-transfer catalyst, tetrabutylammonium sulfate. The limits of detection for cyanide and thiocyanate were 1 µM and 50 nM, respectively. The linear dynamic range was from 10 µM to 20 mM for cyanide and from 500 nM to 200 µM for thiocyanate with correlation coefficients higher than 0.999 for both cyanide and thiocyanate. The precision, as measured by %RSD, was below 9 %, and the accuracy was within 15 % of the nominal concentration for all quality control standards analyzed. The gross recoveries of cyanide and thiocyanate from plasma were over 90 %. Using this method, the toxicokinetic behavior of cyanide and thiocyanate in swine plasma was assessed following cyanide exposure.


Assuntos
Análise Química do Sangue/métodos , Cianetos/sangue , Cromatografia Gasosa-Espectrometria de Massas/normas , Tiocianatos/sangue , Animais , Exposição Ambiental , Limite de Detecção , Suínos
5.
Biomarkers ; 17(7): 625-33, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22889346

RESUMO

Cyanide is highly toxic and is present in many foods, combustion products (e.g. cigarette smoke), industrial processes, and has been used as a terrorist weapon. In this study, cyanide and its major metabolites, thiocyanate and 2-amino-2-thiazoline-4-carboxylic acid (ATCA), were analyzed from various human biofluids of smokers (low-level chronic cyanide exposure group) and non-smokers to gain insight into the relationship of these biomarkers to cyanide exposure. The concentrations of each biomarker tested were elevated for smokers in each biofluid. Significant differences (p < 0.05) were found for thiocyanate in plasma and urine, and ATCA showed significant differences in plasma and saliva. Additionally, biomarker concentration ratios, correlations between markers of cyanide exposure, and other statistical methods were performed to better understand the relationship between cyanide and its metabolites. Of the markers studied, the results indicate plasma ATCA, in particular, showed excellent promise as a biomarker for chronic low-level cyanide exposure.


Assuntos
Cianetos/farmacocinética , Fumar/sangue , Tiazóis/sangue , Tiocianatos/sangue , Biomarcadores/sangue , Biomarcadores/urina , Estudos de Casos e Controles , Cianetos/sangue , Cianetos/urina , Exposição Ambiental , Feminino , Humanos , Masculino , Valores de Referência , Saliva/química , Fumar/urina , Tiazóis/urina , Tiocianatos/urina
SELEÇÃO DE REFERÊNCIAS