Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 90(1): 299-307, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11133922

RESUMO

Myocardial tissue Doppler echocardiography (TDE) has been proposed as a tool for the assessment of diastolic function. Controversy exists regarding whether TDE measurements are influenced by preload. In this study, left ventricular volume and high-fidelity pressures were obtained in eight closed-chest dogs during intermittent caval occlusion. The time constant of isovolumic ventricular relaxation (tau) was altered with varying doses of dobutamine and esmolol. Peak early diastolic myocardial (E(m)) and transmitral (E) velocities were measured before and after preload reduction. The relative effects of changes in preload and relaxation were determined for E(m) and compared with their effects on E. The following results were observed: caval occlusion significantly decreased E (DeltaE = 16.4 +/- 3.3 cm/s, 36.6 +/- 13.7%, P < 0.01) and E(m) (DeltaE(m) = 1. 3 +/- 0.4 cm/s, 32.5 +/- 26.1%, P < 0.01) under baseline conditions. However, preload reduction was similar for E under all lusitropic conditions (P = not significant), but these effects on E(m) decreased with worsening relaxation. At tau < 50 ms, changes in E(m) with preload reduction were significantly greater (DeltaE(m) = 2.8 +/- 0.6 cm/s) than at tau = 50-65 ms (DeltaE(m) = 1.2 +/- 0.2 cm/s) and at tau >65 ms (DeltaE(m) = 0.5 +/- 0.1 cm/s, P < 0.05). We concluded that TDE E(m) is preload dependent. However, this effect decreases with worsening relaxation.


Assuntos
Circulação Coronária , Ecocardiografia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda , Animais , Velocidade do Fluxo Sanguíneo , Constrição Patológica , Diástole , Cães , Valva Mitral/fisiologia , Pressão , Veias Cavas/fisiopatologia , Função Ventricular
2.
Am J Cardiol ; 86(9): 1026-9, A10, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11053722

RESUMO

In this study, we sought evidence for an underlying atrial or ventricular myopathy in patients with paroxysmal lone atrial fibrillation using standard echocardiographic parameters in addition to Doppler tissue imaging of mitral annular motion. No impairment in atrial contractile function was found, but there was evidence for impaired diastolic function in these patients.


Assuntos
Fibrilação Atrial/complicações , Valva Mitral/diagnóstico por imagem , Ultrassonografia Doppler de Pulso/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiologia , Contração Miocárdica/fisiologia , Valores de Referência , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/complicações
3.
J Am Coll Cardiol ; 36(3): 900-7, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10987618

RESUMO

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.


Assuntos
Sistemas Computacionais , Ecocardiografia Tridimensional , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda , Animais , Feminino , Aneurisma Cardíaco/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Ovinos
4.
Eur J Echocardiogr ; 1(2): 96-104, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12086214

RESUMO

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.


Assuntos
Ecocardiografia Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Animais , Velocidade do Fluxo Sanguíneo , Sistemas Computacionais , Fenômenos Eletromagnéticos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ovinos , Volume Sistólico
5.
Am J Cardiol ; 83(2): 218-22, 1999 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-10073824

RESUMO

Endocardial resolution during 2-dimensional echocardiography is technically limited in at least 10% to 15% of patients. Recently, several ultrasound imaging innovations have been introduced that may improve endocardial resolution and decrease the proportion of technically difficult studies. This study compares tissue harmonic imaging, intravenous sonicated albumin, and Doppler myocardial imaging in patients with technically difficult echocardiograms. Twenty-eight patients with known or suspected cardiac disease and poor baseline endocardial resolution were studied. Only harmonic imaging (conventional and optimized for tissue) was superior to baseline fundamental imaging (p <0.001). Harmonic imaging was superior to baseline imaging in all myocardial regions and in the majority of patients, including those with the worst baseline studies.


Assuntos
Albuminas , Meios de Contraste , Ecocardiografia Doppler/métodos , Endocárdio/diagnóstico por imagem , Idoso , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA