Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
BMC Res Notes ; 17(1): 105, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622619

RESUMO

OBJECTIVE: To build and validate an early risk prediction model for gestational diabetes mellitus (GDM) based on first-trimester electronic medical records including maternal demographic and clinical risk factors. METHODS: To develop and validate a GDM prediction model, two datasets were used in this retrospective study. One included data of 14,015 pregnant women from Máxima Medical Center (MMC) in the Netherlands. The other was from an open-source database nuMoM2b including data of 10,038 nulliparous pregnant women, collected in the USA. Widely used maternal demographic and clinical risk factors were considered for modeling. A GDM prediction model based on elastic net logistic regression was trained from a subset of the MMC data. Internal validation was performed on the remaining MMC data to evaluate the model performance. For external validation, the prediction model was tested on an external test set from the nuMoM2b dataset. RESULTS: An area under the receiver-operating-characteristic curve (AUC) of 0.81 was achieved for early prediction of GDM on the MMC test data, comparable to the performance reported in previous studies. While the performance markedly decreased to an AUC of 0.69 when testing the MMC-based model on the external nuMoM2b test data, close to the performance trained and tested on the nuMoM2b dataset only (AUC = 0.70).


Assuntos
Diabetes Gestacional , Gravidez , Feminino , Humanos , Diabetes Gestacional/diagnóstico , Diabetes Gestacional/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Primeiro Trimestre da Gravidez , Demografia
2.
PLoS One ; 19(4): e0302123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630708

RESUMO

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Gravidez , Feminino , Humanos , Idade Gestacional , Projetos Piloto , Reprodutibilidade dos Testes , Estudos de Viabilidade , Estudos Prospectivos , Ecocardiografia/métodos , Ventrículos do Coração , Ecocardiografia Tridimensional/métodos
3.
Front Pediatr ; 12: 1360111, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38425664

RESUMO

To improve care for extremely premature infants, the development of an extrauterine environment for newborn development is being researched, known as Artificial Placenta and Artificial Womb (APAW) technology. APAW facilitates extended development in a liquid-filled incubator with oxygen and nutrient supply through an oxygenator connected to the umbilical vessels. This setup is intended to provide the optimal environment for further development, allowing further lung maturation by delaying gas exposure to oxygen. This innovative treatment necessitates interventions in obstetric procedures to transfer an infant from the native to an artificial womb, while preventing fetal-to-neonatal transition. In this narrative review we analyze relevant fetal physiology literature, provide an overview of insights from APAW studies, and identify considerations for the obstetric procedure from the native uterus to an APAW system. Lastly, this review provides suggestions to improve sterility, fetal and maternal well-being, and the prevention of neonatal transition.

4.
Eur J Obstet Gynecol Reprod Biol ; 291: 23-28, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37806028

RESUMO

OBJECTIVE: Uterine contractions are essential for childbirth, but also for expulsion of the placenta and for limiting postpartum blood loss. Postpartum hemorrhage is associated with almost 25% of the maternal deaths worldwide and the leading cause of maternal death in most low-income countries. Little is known about the physiology of the uterus postpartum, particularly due to the lack of an accurate measurement tool. The primary objective of this pilot study is to explore the potential of using electrohysterography to detect postpartum uterine contractions. If postpartum uterine activity can be objectified, this could contribute to understanding the physiology of the uterus and improve diagnosis and treatment of postpartum hemorrhage. STUDY DESIGN: In this observational study we included women aiming for a vaginal birth in two large maternity clinics in the Netherlands, Amphia Hospital Breda (group A, N2018-0161) and Máxima Medical Center Veldhoven (group B, N17.149). An electrode patch was placed on the maternal abdomen to record real-time electrical uterine activity until one hour postpartum continuously. In group A, the placement of the patch was lower than in group B. For analysis, tracings were divided into five different phases (1: dilatation until start pushing, 2: from start pushing until childbirth, 3: from childbirth until placental expulsion, 4: first hour after placental expulsion and 5: after one hour postpartum). Readability, signal quality and contraction frequency per hour were assessed. Additionally, patient satisfaction was evaluated through a survey. RESULTS: In total 91 pregnant women were included of whom 45 in group A and 46 women in group B. Complete registrations were obtained throughout the five labor phases with very little artefacts or signal loss. The readability of the tracings decreased after childbirth. A significantly better readability was found in tracings where the patch placement was lower on the abdomen for phases 4 and 5. Contraction frequency was highest during phase 2 and decreased towards phase 5. Women rated the satisfaction with electrohysterography as high and mostly did not notice the patch. CONCLUSION: It is possible to detect uterine activity postpartum with electrohysterography. Further investigation is recommended to improve diagnosis and treatment of postpartum hemorrhage.


Assuntos
Hemorragia Pós-Parto , Gravidez , Feminino , Humanos , Hemorragia Pós-Parto/diagnóstico , Projetos Piloto , Placenta , Contração Uterina/fisiologia , Período Pós-Parto
5.
Ann Glob Health ; 89(1): 62, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37780839

RESUMO

Background: Every day approximately 810 women die from complications related to pregnancy and childbirth worldwide. Around two thirds of these deaths happen in sub-Saharan Africa. One of the strategies to decrease these numbers is improving the quality of care by emergency obstetric simulation-based training. The effectiveness of such training programs depends on the program's instructional design. Objective: This review gives an overview of studies about emergency obstetric simulation-based training and examines the applied instructional design of the training programs in sub-Saharan and Central Africa. Methods: We searched Medline, Embase and Cochrane Library from inception to May 2021. Peer-reviewed articles on emergency obstetric, postgraduate, simulation-based training in sub-Saharan and Central Africa were included. Outcome measures were categorized based on Kirkpatrick's levels of training evaluation. The instructional design was evaluated by using the ID-SIM questionnaire. Findings: In total, 47 studies met the inclusion criteria. Evaluation on Kirkpatrick level 1 showed positive reactions in 18 studies. Challenges and recommendations were considered. Results on knowledge, skills, and predictors for these results (Kirkpatrick level 2) were described in 29 studies. Retention as well as decay of knowledge and skills over time were presented. Results at Kirkpatrick level 3 were measured in 12 studies of which seven studies demonstrated improvements of skills on-the-job. Improvements of maternal and neonatal outcomes were described in fifteen studies and three studies reported on cost-estimations for training rollout (Kirkpatrick level 4). Instructional design items were heterogeneously applied and described. Conclusions: Results of 47 studies indicate evidence that simulation-based training in sub-Saharan and Central Africa can have a positive impact across all four levels of Kirkpatrick's training evaluation model. However, results were not consistent across all studies and the effects vary over time. A detailed description of instructional design features in future publications on simulation-based training will contribute to a deeper understanding of the underlying mechanisms that determine why certain training programs are more effective in improving maternal and neonatal healthcare outcomes than other.


Assuntos
Serviços Médicos de Emergência , Complicações do Trabalho de Parto , Feminino , Humanos , Recém-Nascido , Gravidez , África Subsaariana , África Central , Parto Obstétrico/métodos
6.
Birth ; 50(4): 1025-1033, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37550881

RESUMO

BACKGROUND: The purpose of this study was to develop and evaluate an innovative design proposition intended to help enhance the childbirth experience. The innovation consists of a smartphone application for birth preparation during pregnancy with information and coaching, in addition to a wall projection at the labor ward that visualizes the progress of labor based on uterine monitoring data. METHODS: We conducted a randomized controlled clinical pilot study. Singleton pregnant people pursuing a vaginal birth were recruited between 28 and 32 weeks of gestation and allocated to the intervention group (mobile application during the third trimester and wall projection at the labor ward) or to care as usual. Childbirth expectations and experiences were measured with validated questionnaires, which were completed at 32 and 36 weeks of gestation, immediately after birth, and at 4 weeks postpartum. Quantitative outcomes were analyzed and feedback about the proposition was evaluated using qualitative methods. RESULTS: The qualitative feedback from patients was largely positive; however, we could not detect any significant differences between the intervention and control groups about fear of childbirth and other outcome measures. CONCLUSION: In this pilot study, we evaluated a new experience design proposition for pregnancy and childbirth. This study generated data that will help to further improve and evaluate similar innovations in the future. This application may facilitate participatory care, promoting active involvement of parents in the healthcare processes of pregnancy and childbirth.


Assuntos
Trabalho de Parto , Parto , Gravidez , Feminino , Humanos , Projetos Piloto , Parto Obstétrico , Período Pós-Parto
7.
PLoS One ; 18(7): e0287245, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37437012

RESUMO

BACKGROUND: Researchers have long suspected a mutual interaction between maternal and fetal heart rhythms, referred to as maternal-fetal cardiac coupling (MFCC). While several studies have been published on this phenomenon, they vary in terms of methodologies, populations assessed, and definitions of coupling. Moreover, a clear discussion of the potential clinical implications is often lacking. Subsequently, we perform a scoping review to map the current state of the research in this field and, by doing so, form a foundation for future clinically oriented research on this topic. METHODS: A literature search was performed in PubMed, Embase, and Cochrane. Filters were only set for language (English, Dutch, and German literature were included) and not for year of publication. After screening for the title and the abstract, a full-text evaluation of eligibility followed. All studies on MFCC were included which described coupling between heart rate measurements in both the mother and fetus, regardless of the coupling method used, gestational age, or the maternal or fetal health condition. RESULTS: 23 studies remained after a systematic evaluation of 6,672 studies. Of these, 21 studies found at least occasional instances of MFCC. Methods used to capture MFCC are synchrograms and corresponding phase coherence indices, cross-correlation, joint symbolic dynamics, transfer entropy, bivariate phase rectified signal averaging, and deep coherence. Physiological pathways regulating MFCC are suggested to exist either via the autonomic nervous system or due to the vibroacoustic effect, though neither of these suggested pathways has been verified. The strength and direction of MFCC are found to change with gestational age and with the rate of maternal breathing, while also being further altered in fetuses with cardiac abnormalities and during labor. CONCLUSION: From the synthesis of the available literature on MFCC presented in this scoping review, it seems evident that MFCC does indeed exist and may have clinical relevance in tracking fetal well-being and development during pregnancy.


Assuntos
Relevância Clínica , Feto , Feminino , Gravidez , Humanos , Cuidado Pré-Natal , Coração , Idade Gestacional
8.
PLoS One ; 18(7): e0287003, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37437044

RESUMO

OBJECTIVES: Two-dimensional speckle tracking echocardiography has been considered an angle-independent modality. However, current literature is limited and inconclusive on the actual impact of angle of insonation on strain values. Therefore, the primary objective of this study was to assess the impact of angles of insonation on the estimation of fetal left ventricular and right ventricular global longitudinal strain. Secondarily, the impact of different definitions for angles of insonation was investigated in a sensitivity analysis. METHODS: This is a retrospective analysis of a prospective longitudinal cohort study with 124 healthy subjects. The analyses were based on the four-chamber view ultrasound clips taken between 18+0 and 21+6 weeks of gestation. Angles of insonation were categorized into three groups: up/down, oblique and perpendicular. The mean fetal left and right ventricular and global longitudinal strain values corresponding to these three groups were compared by an ANOVA test corrected for heteroscedasticity. RESULTS: Fetal left and right ventricular global longitudinal strain values were not statistically different between the three angles of insonation (p-value >0.062 and >0.149, respectively). When applying another definition for angles of insonation in the sensitivity analysis, the mean left ventricular global longitudinal strain value was significantly decreased for the oblique compared to the up/down angle of insonation (p-value 0.041). CONCLUSIONS: There is no evidence of a difference in fetal left and right ventricular global longitudinal strain between the different angles of insonation in fetal two-dimensional speckle tracking echocardiography.


Assuntos
Ecocardiografia , Deformação Longitudinal Global , Humanos , Estudos Longitudinais , Estudos Prospectivos , Estudos Retrospectivos
9.
BJOG ; 130(5): 495-505, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35974689

RESUMO

OBJECTIVE: To assess the association between trajectories of comorbid anxiety and depressive (CAD) symptoms assessed in each pregnancy trimester and physiological birth. DESIGN: Large longitudinal prospective cohort study with recruitment between January 2013 and September 2014. SETTING: Primary care, in the Netherlands. POPULATION: Dutch-speaking pregnant women with gestational age at birth ≥37 weeks, and without multiple pregnancy, severe psychiatric disorder or chronic disease history. METHODS: Pregnancy-specific anxiety and depressive symptoms were measured prospectively in each trimester of pregnancy using the negative affect subscale of the Tilburg Pregnancy Distress Scale and Edinburgh (Postnatal) Depression Scale. Data on physiological birth were obtained from obstetric records. Multivariate growth mixture modelling was performed in MPLUS to determine longitudinal trajectories of CAD symptoms. Multiple logistic regression analysis was used to examine the association between trajectories and physiological birth. MAIN OUTCOME MEASURES: Trajectories of CAD symptoms and physiological birth. RESULTS: Seven trajectories (classes) of CAD symptoms were identified in 1682 women and subsequently merged into three groups: group 1-persistently low levels of symptoms (reference class 1; 79.0%), group 2-intermittently high levels of symptoms (classes 3, 6 and 7; 11.2%), and group 3-persistently high levels of symptoms (classes 2, 4 and 5; 9.8%). Persistently high levels of CAD symptoms (group 3) were associated with a lower likelihood of physiological birth (odds ratio 0.67, 95% confidence interval 0.47-0.95, P = 0.027) compared with the reference group (persistently low levels of symptoms), after adjusting for confounders. CONCLUSIONS: This study is the first showing evidence that persistently high CAD levels, assessed in each pregnancy trimester, are associated with a lower likelihood of physiological birth.


Assuntos
Depressão Pós-Parto , Complicações na Gravidez , Recém-Nascido , Gravidez , Feminino , Humanos , Depressão/epidemiologia , Depressão/psicologia , Estudos Prospectivos , Parto , Ansiedade/epidemiologia , Ansiedade/psicologia , Gestantes , Complicações na Gravidez/epidemiologia , Complicações na Gravidez/psicologia , Depressão Pós-Parto/psicologia
10.
Eur J Obstet Gynecol Reprod Biol ; 278: 159-165, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36208521

RESUMO

INTRODUCTION: Worldwide, cardiotocography is used for continuous monitoring of fetal heart rate (FHR) and uterine contractions during labour. Different methods for FHR registration and registration of contractions are available. Literature about the frequency of use of different fetal monitoring methods is lacking. OBJECTIVE: To evaluate the use of and preferences for fetal monitoring methods for intrapartum fetal monitoring among Dutch obstetric care providers. STUDY DESIGN: Between October and November 2020 the Dutch Society of Obstetrics and Gynaecology sent an email invitation to all secondary care midwives and gynaecologists (in training) in the Netherlands to complete an online survey regarding the use and personal experience with fetal monitoring methods. The survey mainly consisted of multiple choice questions. Descriptive statistics are reported. Continuous variables were presented as median with interquartile ranges (IQR). Categorical variables were expressed as numbers with percentages. RESULTS: The response rate was 29 % (n/N = 510/1748). All Dutch hospitals were represented. The respondents estimated the use of fetal scalp electrode (FSE) at 71 % (IQR 58-85 %) of deliveries. The most common indication for use of the FSE was inadequate external FHR registration (94 %). More than half (54 %) of the respondents reported to use intrauterine pressure catheter with an estimated use of 5 % (IQR 2-8 %) of deliveries. The most common indication for use of intrauterine pressure catheter was inadequate external contraction registration (75 %). The use of ST-analysis was reported in 25 % of the respondents with an estimated use of 60 % (IQR 30-72 %) of deliveries. Almost all respondents (99 %) reported to use fetal blood sampling with an estimated use of 15 % (IQR 10-23 %) of deliveries. Ninety percent of respondents would prefer a valid and reliable external monitoring technique during labour. Thirty-one percent of respondents assume that external fetal monitoring with non-invasive fetal electrocardiography and electrohysterography will become standard care within the next 5 years. CONCLUSIONS: Currently, the FSE is the most used technique for FHR monitoring during labour in the Netherlands. The most common indication for use of FSE is inadequate external FHR registration. Obstetric care providers would prefer a non-invasive external registration method that provides reliable data.


Assuntos
Cardiotocografia , Trabalho de Parto , Gravidez , Feminino , Humanos , Países Baixos , Cardiotocografia/métodos , Frequência Cardíaca Fetal/fisiologia , Monitorização Fetal/métodos , Trabalho de Parto/fisiologia , Inquéritos e Questionários
12.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 467-474, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35236745

RESUMO

OBJECTIVE: In 2010, the Dutch practice regarding initiation of active treatment in extremely preterm infants was lowered from 25 completed weeks' to 24 completed weeks' gestation. The nationwide Extremely Preterm Infants - Dutch Analysis on Follow-up Study was set up to provide up-to-date data on neurodevelopmental outcome at 2 years' corrected age (CA) after this guideline change. Design: National cohort study. PATIENTS: All live born infants between 240/7 weeks' and 266/7 weeks' gestational age who were 2 years' CA in 2018-2020. MAIN OUTCOME MEASURE: Impairment at 2 years' CA, based on cognitive score (Bayley-III-NL), neurological examination and neurosensory function. RESULTS: 651 of 991 live born infants (66%) survived to 2 years' CA, with data available for 554 (85%). Overall, 62% had no impairment, 29% mild impairment and 9% moderate-to-severe impairment (further defined as neurodevelopmental impairment, NDI). The percentage of survivors with NDI was comparable for infants born at 24 weeks', 25 weeks' and 26 weeks' gestation. After multivariable analysis, severe brain injury and low maternal education were associated with higher odds on NDI. NDI-free survival was 48%, 67% and 75% in neonatal intensive care unit (NICU)-admitted infants at 24, 25 and 26 weeks' gestation, respectively. CONCLUSIONS: Lowering the threshold has not been accompanied by a large increase in moderate-to-severely impaired infants. Among live-born and NICU-admitted infants, an increase in NDI-free survival was observed from 24 weeks' to 26 weeks' gestation. This description of a national cohort with high follow-up rates gives an accurate description of the range of outcomes that may occur after extremely preterm birth.


Assuntos
Doenças do Prematuro , Transtornos do Neurodesenvolvimento , Nascimento Prematuro , Criança , Pré-Escolar , Estudos de Coortes , Deficiências do Desenvolvimento/diagnóstico , Deficiências do Desenvolvimento/epidemiologia , Deficiências do Desenvolvimento/etiologia , Feminino , Seguimentos , Idade Gestacional , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Doenças do Prematuro/diagnóstico , Transtornos do Neurodesenvolvimento/epidemiologia , Transtornos do Neurodesenvolvimento/etiologia , Gravidez
13.
J Matern Fetal Neonatal Med ; 35(25): 7375-7380, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34304667

RESUMO

BACKGROUND: The value of ST analysis of the fetal electrocardiogram during labor to lower asphyxia and cesarean section rates is uncertain. Physiological variation of the electrical heart axis between fetuses may explain false alarms in conventional ST analysis (absolute ST analysis). ST events (alarms) based on relative T/QRS rises (relative ST analysis) correct for this variation and may improve diagnostic accuracy of ST analysis. AIMS: To compare the diagnostic accuracy of absolute and relative ST analysis with regard to fetal acidemia. STUDY DESIGN: Retrospective case-control study. SUBJECTS: 20 healthy women with an uncomplicated pregnancy monitored with ST analysis during labor: 10 cases (umbilical cord artery pH < 7.05) and 10 controls (pH > 7.20). OUTCOME MEASURES: Sensitivity, specificity, positive and negative likelihood ratio. RESULTS: In 16 of the 20 patients a total of 54 absolute ST events were reported. Two reviewers classified the cardiotocograms; in cases 29% of the absolute ST events were significant, in the controls it was 19%. Relative ST analysis versus absolute ST analysis showed a sensitivity of 90% (55-100%) vs. 70% (35-93%), a specificity of 100% (69-100%) vs. 70% (35-93%), a positive likelihood ratio of infinity vs. 2.3 (0.8-6.5), a negative likelihood ratio of 0.1 (0.0-0.6) vs. 0.4 (0.2-1.2), and diagnostic odds ratio of infinity vs. 5.4 (0.8-36.9). McNemar showed no statistical significant difference between the sensitivity and specificity of the methods. CONCLUSIONS: We observed higher positive and lower negative likelihood ratios for relative ST analysis in comparison to absolute ST analysis. In this small study we found no statistical difference. Relative ST analysis should be studied in a larger study.


Assuntos
Cesárea , Trabalho de Parto , Humanos , Feminino , Gravidez , Estudos de Casos e Controles , Estudos Retrospectivos , Cardiotocografia/métodos , Eletrocardiografia/métodos , Frequência Cardíaca Fetal , Monitorização Fetal/métodos
14.
PLoS One ; 16(12): e0256115, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34914710

RESUMO

INTRODUCTION: A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. MATERIAL AND METHODS: Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. RESULTS: Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). DISCUSSION: The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.


Assuntos
Eletrocardiografia , Coração Fetal , Feto , Diagnóstico Pré-Natal , Adolescente , Adulto , Estudos de Coortes , Feminino , Humanos , Gravidez
15.
Eur J Obstet Gynecol Reprod Biol ; 259: 178-184, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33684672

RESUMO

OBJECTIVE: Electrohysterography is a non-invasive technique to monitor uterine activity and has a significantly higher sensitivity compared to conventional external tocodynamometry. Whether this technique could lead to improved obstetrical outcomes is still unknown. In this propensity score matched study, clinical results of the first pilot implementing electrohysterography during labor were evaluated. The hypothesis tested is that electrohysterography will help to optimize uterine activity and thereby lead to fewer obstetric interventions. Secondary outcomes were Apgar score, arterial umbilical pH values, first stage labor duration, episiotomy rate and postpartum vaginal blood loss. STUDY DESIGN: From November 2017 until October 2018, electrohysterography was introduced as a standard alternative for monitoring uterine activity in high-risk deliveries. It could be applied in case of induced labor, previous cesarean delivery, body mass index ≥30 kg/m2 or an inadequate external tocodynamometry monitoring. Outcomes were compared to a matched group of women in which external tocodynamometry was applied for uterine activity monitoring during labor. These women were identified using propensity scores. RESULTS: A total of 348 women received electrohysterography as standard method of uterine monitoring during labor. A match (1:1 ratio) was found for 317 women, resulting in a total population of 634 women. No significant differences were seen in obstetric interventions (i.e. cesarean deliveries and assisted vaginal deliveries) between the electrohysterography and tocodynamometry group (P = 0.80). No statistically significant differences were seen regarding the secondary outcomes. CONCLUSIONS: This first pilot study implementing electrohysterography as monitoring method during labor in a high-risk population did not result in statistically significant differences regarding obstetric interventions, low Apgar scores or low umbilical artery pH values. Therefore, we suggest that electrohysterography causes no harm and we recommend further implementation and evaluation in clinical practice.


Assuntos
Trabalho de Parto , Contração Uterina , Adolescente , Eletromiografia , Feminino , Humanos , Projetos Piloto , Gravidez , Pontuação de Propensão , Projetos de Pesquisa
16.
Clin Pract ; 11(1): 13-25, 2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33599215

RESUMO

Pregnancy is a period of continuous change in the maternal cardiovascular system, partly mediated by the autonomic nervous system. Insufficient autonomic adaptation to increasing gestation is associated with pregnancy complications, such as hypertensive disorders of pregnancy and preterm birth (both major causes of perinatal morbidity and mortality). Consequently, maternal heart rate variability (mHRV), which is a proxy measure for autonomic activity, is increasingly assessed in these cohorts to investigate the pathophysiology of their complications. A better pathophysiological understanding could facilitate the early detection of these complications, which remains challenging. However, such studies (typically performed in pregnancies leading to hospitalization) have generated conflicting findings. A probable reason for these conflicting findings is that these study cohorts were likely administered routine obstetric medications during the study period of which the effects on mHRV are largely unknown. Subsequently, we design a longitudinal, observational study to quantifying the effect of these medications-particularly corticosteroids, which are known to affect fetal HRV-on mHRV to improve the interpretation of past and future studies. We will enroll 61 women admitted to a tertiary obstetric unit with an indication to receive corticosteroids antenatally. Participants' mHRV will be continuously acquired throughout their hospitalization with wrist-worn photoplethysmography to facilitate a within-patient comparison of the effect of corticosteroids on mHRV.

18.
JMIR Med Educ ; 7(1): e17277, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33544086

RESUMO

BACKGROUND: Simulation-based training is a common strategy for improving the quality of facility-based maternity services and is often evaluated using Kirkpatrick's theoretical model. The results on the Kirkpatrick levels are closely related to the quality of the instructional design of a training program. The instructional design is generally defined as the "set of prescriptions for teaching methods to improve the quality of instruction with a goal of optimizing learning outcomes." OBJECTIVE: The aim of this study is to evaluate the instructional design of a technology-enhanced simulation-based training in obstetrics, the reaction of participants, and the effect on knowledge, teamwork, and skills in a low-income country. METHODS: A stepped-wedge cluster randomized trial was performed in a university hospital in Kampala, Uganda, with an annual delivery volume of over 31,000. In November 2014, a medical simulation center was installed with a full-body birthing simulator (Noelle S550, Gaumard Scientific), an interactive neonate (Simon S102 Newborn CPR Simulator, Gaumard Scientific), and an audio and video recording system. Twelve local obstetricians were trained and certified as medical simulation trainers. From 2014 to 2016, training was provided to 57 residents in groups of 6 to 9 students. Descriptive statistics were calculated for ten instructional design features of the training course measured by the 42-item ID-SIM (Instructional Design of a Simulation Improved by Monitoring). The Wilcoxon signed rank test was conducted to investigate the differences in scores on knowledge, the Clinical Teamwork Scale, and medical technical skills. RESULTS: The mean scores on the ten instructional design features ranged from 54.9 (95% CI 48.5-61.3) to 84.3 (95% CI 80.9-87.6) out of 100. The highest mean score was given on the feature feedback and the lowest scores on repetitive practice and controlled environment. The overall score for the training day was 92.8 out of 100 (95% CI 89.5-96.1). Knowledge improved significantly, with a test score of 63.4% (95% CI 60.7-66.1) before and 78.9% (95% CI 76.8-81.1) after the training (P<.001). The overall score on the 10-point Clinical Teamwork Scale was 6.0 (95% CI 4.4-7.6) before and 5.9 (95% CI 4.5-7.2) after the training (P=.78). Medical technical skills were scored at 55.5% (95% CI 47.2-63.8) before and 65.6% (95% CI 56.5-74.7) after training (P=.08). CONCLUSIONS: Most instructional design features of a technology-enhanced simulation-based training in obstetrics in a low-income country were scored high, although intervals were large. The overall score for the training day was high, and knowledge did improve after the training program, but no changes in teamwork and (most) medical technical skills were found. The lowest-scored instructional design features may be improved to achieve further learning aims. TRIAL REGISTRATION: ISRCTN Registry ISRCTN98617255; http://www.isrctn.com/ISRCTN98617255. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1186/s12884-020-03050-3.

19.
Front Pediatr ; 9: 793531, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127593

RESUMO

Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants.

20.
Int J Gynaecol Obstet ; 154(1): 44-48, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33251616

RESUMO

OBJECTIVE: To establish the storage conditions of oxytocin in a health facility in a low-income country with a tropical climate, as suboptimal storage may lead to ineffectiveness of drugs essential to prevent and treat postpartum hemorrhage. METHODS: At Mulago National Referral Hospital (28 000-33 000 deliveries/year) in Kampala, Uganda, temperature logging Safe-Rx cards were placed in boxes of oxytocin and in every known storage location. The route of the boxes through the hospital was tracked for 54 days, and storage conditions were observed. RESULTS: Oxytocin was stored within the recommended temperature range (2°C-8°C) 24% of the time. The average temperature measured within the oxytocin boxes was 18.2°C, with a minimum of -2.3°C and maximum of 30.4°C. Six out of twelve known storage places had a refrigerator, but not one location stored medication at the recommended temperature constantly. The average temperature in the storage places ranged from 9.5°C to 27.6°C, with a minimum temperature of 2.3°C and maximum of 30.9°C. CONCLUSION: Oxytocin is not stored in the recommended temperature range for the majority of time. The presence of refrigerators does not ensure adherence to advised temperature storage conditions.


Assuntos
Armazenamento de Medicamentos , Ocitocina/química , Clima Tropical , Feminino , Humanos , Hemorragia Pós-Parto/prevenção & controle , Pobreza , Gravidez , Refrigeração , Temperatura , Uganda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...