Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Brain Topogr ; 36(1): 1-9, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36446998

RESUMO

The determination of exact tumor boundaries within eloquent brain regions is essential to maximize the extent of resection. Recent studies showed that intraoperative optical imaging (IOI) combined with median nerve stimulation is a helpful tool for visualization of the primary sensory cortex (PSC). In this technical note, we describe a novel approach of using IOI with painless tactile irritation to demonstrate the feasibility of topographic mapping of different body regions within the PSC. In addition, we compared the IOI results with preoperative functional MRI (fMRI) findings. In five patients with tumors located near the PSC who received tumor removal, IOI with tactile irritation of different body parts and fMRI was applied. We showed that tactile irritation of the hand in local and general anesthesia leads to reliable changes of cerebral blood volume during IOI. Hereby, we observed comparable IOI activation maps regarding the median nerve stimulation, fMRI and tactile irritation of the hand. The tactile irritation of different body areas revealed a plausible topographic distribution along the PSC. With this approach, IOI is also suitable for awake surgeries, since the tactile irritation is painless compared with median nerve stimulation and is congruent to fMRI findings. Further studies are ongoing to standardize this method to enable a broad application within the neurosurgical community.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Neoplasias Encefálicas/cirurgia , Glioma/cirurgia , Mapeamento Encefálico/métodos , Encéfalo , Imageamento por Ressonância Magnética/métodos , Córtex Cerebral
2.
Anal Bioanal Chem ; 415(4): 603-613, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36462048

RESUMO

The in ovo sexing of chicken eggs is a current task and a prerequisite to overcome the mass killing of male day-old chicks from laying lines. Although various methods have been developed and tested in recent years, practicable methods for sex determination are still missing which can be applicated in poultry hatcheries before the chicken embryo is capable of nociception and pain sensation. Optical spectroscopic methods enable an early determination of the sex. In this study, a novel method based on two-wavelength in ovo fluorescence excitation is described. More than 1600 eggs were examined. In ovo fluorescence was sequentially excited at 532 nm and 785 nm. The fluorescence intensities of the spectral regions behave inversely with respect to sex. It is shown that the observed sex-related differences in the fluorescence intensities are based on the embryonic hemoglobin synthesis. The accuracy of sex determination is 96% for both sexes. The hatching rate is not reduced compared to an equivalent reference group.


Assuntos
Galinhas , Análise para Determinação do Sexo , Feminino , Embrião de Galinha , Animais , Masculino , Espectrometria de Fluorescência/métodos , Análise para Determinação do Sexo/métodos , Ovos , Óvulo
3.
Int J Comput Assist Radiol Surg ; 17(4): 683-697, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35175502

RESUMO

PURPOSE: The purpose of this study is to analyze and compare six automatic intensity-based registration methods for intraoperative infrared thermography (IRT) and visible light imaging (VIS/RGB). The practical requirement is to get a good performance of Euclidean distance between manually set landmarks in reference and target images as well as to achieve a high structural similarity index metric (SSIM) and peak signal-to-noise ratio (PSNR) with respect to the reference image. METHODS: In this study, preprocessing is applied to bring both image types to a similar intensity. Similarity transformation is employed to align roughly IRT and visible light images. Two optimizers and two measures are used in this process. Thereafter, due to locally different displacement of the brain surface through respiration and heartbeat, two non-rigid transformations are applied, and finally, a bicubic interpolation is carried out to compensate for the resulting estimated transformation. Performance was assessed using eleven image datasets. The registration accuracy of the different computational approaches was assessed based on SSIM and PSNR. Additionally, five concise landmarks for each dataset were selected manually in reference and target images and the Euclidean distance between the corresponding landmarks was compared. RESULTS: The results are showing that the combination of normalized intensity, mutual information measure with one-plus-one evolutionary optimizer in combination with Demon registration results in improved accuracy and performance as compared to all other methods tested here. Furthermore, the obtained results led to [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] registrations for datasets 1, 2, 5, 7, and 8 with respect to the second best result by calculating the mean Euclidean distance of five landmarks. CONCLUSIONS: We conclude that the mutual information measure with one-plus-one evolutionary optimizer in combination with Demon registration can achieve better accuracy and performance to those other methods mentioned here for automatic registration of IRT and visible light images in neurosurgery.


Assuntos
Neurocirurgia , Algoritmos , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Humanos , Luz , Procedimentos Neurocirúrgicos , Tomografia Computadorizada por Raios X/métodos
4.
Hum Brain Mapp ; 43(2): 598-615, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34590384

RESUMO

Alterations within cerebral hemodynamics are the intrinsic signal source for a wide variety of neuroimaging techniques. Stimulation of specific functions leads due to neurovascular coupling, to changes in regional cerebral blood flow, oxygenation and volume. In this study, we investigated the temporal characteristics of cortical hemodynamic responses following electrical, tactile, visual, and speech activation for different stimulation paradigms using Intraoperative Optical Imaging (IOI). Image datasets from a total of 22 patients that underwent surgical resection of brain tumors were evaluated. The measured reflectance changes at different light wavelength bands, representing alterations in regional cortical blood volume (CBV), and deoxyhemoglobin (HbR) concentration, were assessed by using Fourier-based evaluation methods. We found a decrease of CBV connected to an increase of HbR within the contralateral primary sensory cortex (SI) in patients that were prolonged (30 s/15 s) electrically stimulated. Additionally, we found differences in amplitude as well as localization of activated areas for different stimulation patterns. Contrary to electrical stimulation, prolonged tactile as well as prolonged visual stimulation are provoking increases in CBV within the corresponding activated areas (SI, visual cortex). The processing of the acquired data from awake patients performing speech tasks reveals areas with increased, as well as areas with decreased CBV. The results lead us to the conclusion, that the CBV decreases in connection with HbR increases in SI are associated to processing of nociceptive stimuli and that stimulation type, as well as paradigm have a nonnegligible impact on the temporal characteristics of the following hemodynamic response.


Assuntos
Neoplasias Encefálicas/cirurgia , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Circulação Cerebrovascular/fisiologia , Monitorização Neurofisiológica Intraoperatória , Neuroimagem , Imagem Óptica , Percepção/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nociceptividade/fisiologia , Percepção da Fala/fisiologia , Percepção do Tato/fisiologia , Percepção Visual/fisiologia , Adulto Jovem
5.
Neurosurg Focus ; 48(2): E3, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32006940

RESUMO

Intraoperative optical imaging (IOI) is a marker-free, contactless, and noninvasive imaging technique that is able to visualize metabolic changes of the brain surface following neuronal activation. Although it has been used in the past mainly for the identification of functional brain areas under general anesthesia, the authors investigated the potential of the method during awake surgery. Measurements were performed in 10 patients who underwent resection of lesions within or adjacent to cortical language or motor sites. IOI was applied in 3 different scenarios: identification of motor areas by using finger-tapping tasks, identification of language areas by using speech tasks (overt and silent speech), and a novel approach-the application of IOI as a feedback tool during direct electrical stimulation (DES) mapping of language. The functional maps, which were calculated from the IOI data (activity maps), were qualitatively compared with the functional MRI (fMRI) and the electrophysiological testing results during the surgical procedure to assess their potential benefit for surgical decision-making.The results reveal that the intraoperative identification of motor sites with IOI in good agreement with the preoperatively acquired fMRI and the intraoperative electrophysiological measurements is possible. Because IOI provides spatially highly resolved maps with minimal additional hardware effort, the application of the technique for motor site identification seems to be beneficial in awake procedures. The identification of language processing sites with IOI was also possible, but in the majority of cases significant differences between fMRI, IOI, and DES were visible, and therefore according to the authors' findings the IOI results are too unspecific to be useful for intraoperative decision-making with respect to exact language localization. For this purpose, DES mapping will remain the method of choice.Nevertheless, the IOI technique can provide additional value during the language mapping procedure with DES. Using a simple difference imaging approach, the authors were able to visualize and calculate the spatial extent of activation for each stimulation. This might enable surgeons in the future to optimize the mapping process. Additionally, differences between tumor and nontumor stimulation sites were observed with respect to the spatial extent of the changes in cortical optical properties. These findings provide further evidence that the method allows the assessment of the functional state of neurovascular coupling and is therefore suited for the delineation of pathologically altered tissue.


Assuntos
Mapeamento Encefálico/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Idioma , Córtex Motor/diagnóstico por imagem , Destreza Motora/fisiologia , Procedimentos Neurocirúrgicos/métodos , Imagem Óptica/métodos , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Feminino , Glioma/diagnóstico por imagem , Glioma/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Motor/cirurgia , Vigília/fisiologia
6.
Biomed Tech (Berl) ; 63(5): 587-594, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-29397378

RESUMO

Brain tumor resection is even today one of the most challenging disciplines in neurosurgery. The current state of the art for the identification of tumor tissue during the surgical procedure comprises a wide variety of different tools, each with its own limitations and drawbacks. In this paper, we present a novel approach, the use of optical imaging in connection with direct electrical cortical stimulation (DCS), for identification of impaired tumor tissue and functional intact normal brain tissue under intraoperative conditions. Measurements with an optical imaging setup were performed as a proof of concept on three patients who underwent tumor resection of superficial gliomas. Direct electrical stimulations were applied on tumor tissue and surrounding brain tissue in each patient and characteristic features from the observed changes in the optical properties were compared between the different groups. The results reveal that in all patients a differentiation between non-functional tumor tissue and functional intact brain tissue was possible, and the technique might be a useful clinical tool in the future.


Assuntos
Neoplasias Encefálicas/patologia , Encéfalo/cirurgia , Estimulação Elétrica/métodos , Procedimentos Neurocirúrgicos/métodos , Glioma , Humanos
7.
Biomed Tech (Berl) ; 58(3): 257-67, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23729532

RESUMO

Intraoperative optical imaging (IOI) is a localization method for functional areas of the human brain cortex during neurosurgical procedures. The aim of the current work was to develop of a new analysis technique for the computation of two-dimensional IOI activity maps that is suited especially for use in clinical routine. The new analysis technique includes a stimulation scheme that comprises 30-s rest and 30-s stimulation conditions, in connection with pixelwise spectral power analysis for activity map calculation. A software phantom was used for verification of the implemented algorithms as well as for the comparison with the commonly used relative difference imaging method. Furthermore, the analysis technique was tested using intraoperative measurements on eight patients. The comparison with the relative difference algorithm revealed an averaged improvement of the signal-to-noise ratio between 95% and 130% for activity maps computed from intraoperatively acquired patient datasets. The results show that the new imaging technique improves the activity map quality of IOI especially under difficult intraoperative imaging conditions and is therefore especially suited for use in clinical routine.


Assuntos
Algoritmos , Mapeamento Encefálico/métodos , Neoplasias Encefálicas/fisiopatologia , Neoplasias Encefálicas/cirurgia , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Animais , Neoplasias Encefálicas/patologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Masculino , Microscopia/instrumentação , Microscopia/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA