Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neuroeng Rehabil ; 9: 2, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22248160

RESUMO

BACKGROUND: The evaluation of hand function impairment following a neurological disorder (stroke and cervical spinal cord injury) requires sensitive, reliable and clinically meaningful assessment tools. Clinical performance measures of hand function mainly focus on the accomplishment of activities of daily living (ADL), typically rather complex tasks assessed by a gross ordinal rating; while the motor performance (i.e. kinematics) is less detailed. The goal of this study was to develop a low-cost instrumented glove to capture details in grasping, feasible for the assessment of hand function in clinical practice and rehabilitation settings. METHODS: Different sensor types were tested for output signal stability over time by measuring the signal drift of their step responses. A system that converted sensor output voltages into angles based on pre-measured curves was implemented. Furthermore, the voltage supply of each sensor signal conditioning circuit was increased to enhance the sensor resolution. The repeatability of finger bending trajectories, recorded during the performance of three ADL-based tasks, was established using the intraclass correlation coefficient (ICC). Moreover, the accuracy of the glove was evaluated by determining the agreement between angles measured with the embedded sensors and angles measured by traditional goniometry. In addition, the feasibility of the glove was tested in four patients with a pathological hand function caused by a cervical spinal cord injury (cSCI). RESULTS: A sensor type that displayed a stable output signal over time was identified, and a high sensor resolution of 0.5° was obtained. The evaluation of the glove's reliability yielded high ICC values (0.84 to 0.92) with an accuracy error of about ± 5°. Feasibility testing revealed that the glove was sensitive to distinguish different levels of hand function impairment in cSCI patients. CONCLUSIONS: The device satisfied the desired system requirements in terms of low cost, stable sensor signal over time, full finger-flexion range of motion tracking and capability to monitor all three joints of one finger. The developed rapid calibration system for easy use (high feasibility) and excellent psychometric properties (i.e. reliability and validity) qualify the device for the assessment of hand function in clinical practice and rehabilitation settings.


Assuntos
Artrometria Articular/instrumentação , Mãos/fisiologia , Traumatismos da Medula Espinal/reabilitação , Adolescente , Adulto , Idoso , Feminino , Força da Mão/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia , Adulto Jovem
2.
Artigo em Inglês | MEDLINE | ID: mdl-21096935

RESUMO

Following hand function impairment caused by a neurological disorder, the functional level of the upper extremities has to be assessed in the clinical and rehabilitation settings. Current hand function evaluation tests are somewhat imprecise. Instrumented gloves allow finger motion monitoring during the performance of skilled tasks, such as grasping objects. As a result, they provide an objective tool for evaluating slight changes in the fine motor skills of the hand. Numerous gloves are based on resistive bend sensors, given that this is an easy to handle, low-cost, and reliable sensing element. When bending is not applied homogeneously along such a sensor, as is the case with finger-joint bending, its output response varies with the sensor's longitudinal position. Our goal is to determine the optimal sensor position with respect to the finger-joint in order to enhance the resolution of the sensors embedded in a glove. The validity of the integrated sensors is evaluated and the accuracy values are given.


Assuntos
Artrometria Articular/instrumentação , Melhoramento Biomédico/métodos , Articulações dos Dedos/fisiopatologia , Luvas Protetoras , Doenças do Sistema Nervoso/fisiopatologia , Doenças do Sistema Nervoso/reabilitação , Humanos , Amplitude de Movimento Articular/fisiologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA