Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.082
Filtrar
1.
J Laryngol Otol ; 138(4): 405-409, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37646247

RESUMO

OBJECTIVE: This study aimed to quantitatively investigate airborne particle load in the operating room during endoscopic or microscopic epitympanectomy or mastoidectomy. METHOD: In the transcanal endoscopic ear surgery group, drilling was performed underwater. A particle counter was used to measure the particle load before, during and after drilling during transcanal endoscopic ear surgery or microscopic ear surgery. The device counted the numbers of airborne particles of 0.3, 0.5 or 1.0 µm in diameter. RESULTS: The particle load during drilling was significantly higher in the microscopic ear surgery group (n = 5) than in the transcanal endoscopic ear surgery group (n = 11) for all particle sizes (p < 0.01). In the transcanal endoscopic ear surgery group, no significant differences among the particle load observed before, during and after drilling were seen for any of the particle sizes. CONCLUSION: Bone dissection carries a lower risk of airborne infection if it is performed using the endoscopic underwater drilling technique.


Assuntos
Salas Cirúrgicas , Procedimentos Cirúrgicos Otológicos , Humanos , Procedimentos Cirúrgicos Otológicos/métodos , Endoscopia/métodos , Mastoidectomia , Dissecação , Estudos Retrospectivos
2.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862490

RESUMO

Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (λ0 = 468.6 nm) of energetic 3He produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.

3.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37819204

RESUMO

A fast-sampling fast-ion D-alpha (F-FIDA) measurement has been developed in the large helical device in order to investigate fast ion dynamics associated with helically trapped fast-ion-driven Magnetohydrodynamic (MHD) bursts. F-FIDA consists of a multi-anode photomultiplier tube (PMT) and achieves a sampling rate of 10 kHz. During the deuterium experiment campaign in 2022, F-FIDA measured the spectrum of perpendicular fast ions, using perpendicular lines of sight. We compared F-FIDA with conventional FIDA, using an electron multiplying charge coupled device, and confirmed that the time-averaged images were generally consistent between the two. The statistical properties of the temporal evolution associated with MHD bursts were analyzed using a conditional sampling technique. The results showed that the PMT signal varied in different spatial and wavelength channels. Although the signal-to-noise ratio was poor and there was room for improvement, it could provide useful information for studies on the phase-space dynamics of fast ions.

4.
J Eur Acad Dermatol Venereol ; 37(12): 2526-2536, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37478291

RESUMO

BACKGROUND: The effectiveness of moisturizers in preventing infant atopic dermatitis (AD) remains unclear. We previously showed that using 2e moisturizer of commercial moisturizer (Shiseido Japan Co., Ltd.) at least once a day significantly prevented AD in infants as compared with as-needed petroleum jelly. This trial aimed to determine the effectiveness of twice- or once-daily application of Fam's Baby moisturizer (Fam's Inc.) in preventing AD compared with once-daily 2e moisturizer. METHODS: This trial was a single-centre, three-parallel-group, assessor-blinded, superiority, individually randomized, controlled, phase II trial that was conducted from 25 August 2020 to 28 September 2021. We randomly assigned 60 newborns with at least one parent or sibling who has AD to receive Fam's Baby moisturizer twice daily (Group A) or once daily (Group B), or 2e once daily (Group C) in a 1:1:1 ratio until they were 32 weeks old. The primary outcome was the time of AD onset. RESULTS: Atopic dermatitis was observed in 11/20 (55%), 5/20 (25%) and 10/20 (50%), infants in Groups A, B and C, respectively. Cumulative incidence values for AD according to the Kaplan-Meier method showed that infants in Group B tended to maintain an intact skin for a longer period than those in Group C (median time, not reached [NR] vs. 212 days, log-rank test, p = 0.064). Cox regression analysis showed that the risk of AD tended to be lower in Group B (hazard ratio with group C as control, 0.36; 95% confidential intervals: 0.12-1.06). No serious adverse events occurred in any of the enrolled infants. CONCLUSION: Fam's Baby moisturizer may better prevent AD than 2e. Further large-scale trials should be performed to confirm the efficacy of Fam's Baby moisturizer in preventing AD in infants.


Assuntos
Dermatite Atópica , Humanos , Recém-Nascido , Dermatite Atópica/tratamento farmacológico , Dermatite Atópica/prevenção & controle , Emolientes/uso terapêutico , Incidência , Vaselina , Resultado do Tratamento
5.
J Nutr Health Aging ; 27(5): 340-347, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37248757

RESUMO

OBJECTIVES: Preserving sufficient oral function and maintaining aadequate nutrition are essential for preventing physical frailty and the following long-term care. We recently developed the 6-month Comprehensive Awareness Modification of Mouth, Chewing And Meal (CAMCAM) program, in which participants gather monthly to learn about oral health and nutrition while eating a textured lunch together. This study examined whether the CAMCAM program could improve attitude and behavior towards oral health, mastication, and diet as well as ameliorate oral frailty in community-dwelling older adults. DESIGN: Single-arm pre-post comparison study. SETTING AND PARTICIPANTS: A total of 271 community-dwelling adults (72.3 ± 5.7 years of age; 159 women [58.7%]) in 4 Japanese municipalities were recruited, of which 249 participants (92%) were assessed at the final evaluation. INTERVENTION: Participants gathered once a month at community centers to learn about oral health and nutrition while eating a "munchy" textured lunch containing proper nutrition. MEASUREMENTS: Oral frailty, frailty, and eating behavior were evaluated with the Oral Frailty Index-8 (OFI-8), Kihon checklist (KCL), and CAMCAM checklist, respectively. Participants were divided into Oral frailty (OF) and Robust groups according to OFI-8 scores. The differences in KCL and CAMCAM checklist results between the OF and Robust groups were statistically tested along with changes in scores after the program. RESULTS: KCL and CAMCAM checklist scores were significantly lower in the OF group at the initial assessment. OFI-8 and KCL findings were significantly improved in the OF group after completing the program (all P <0.05). Regarding the CAMCAM checklist, awareness of chewing improved significantly in the Robust group (P=0.009), with a similar tendency in the OF group (P=0.080). CONCLUSION: The findings of this pilot study suggest that the CAMCAM program may improve both oral and systemic frailty in addition to attitudes towards chewing, oral health, and meals, especially in individuals with oral frailty. The CAMCAM program merits expansion as a community-based frailty prevention program.


Assuntos
Fragilidade , Humanos , Feminino , Idoso , Fragilidade/prevenção & controle , Mastigação , Projetos Piloto , Saúde Bucal , Comportamento Alimentar , Boca , Refeições , Vida Independente , Atitude , Idoso Fragilizado , Japão , Avaliação Geriátrica
6.
Nat Commun ; 14(1): 667, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36750576

RESUMO

The recently discovered kagome superconductors AV3Sb5 (A = K, Rb, Cs) exhibit unusual charge-density-wave (CDW) orders with time-reversal and rotational symmetry breaking. One of the most crucial unresolved issues is identifying the symmetry of the superconductivity that develops inside the CDW phase. Theory predicts a variety of unconventional superconducting symmetries with sign-changing and chiral order parameters. Experimentally, however, superconducting phase information in AV3Sb5 is still lacking. Here we report the impurity effects in CsV3Sb5 using electron irradiation as a phase-sensitive probe of superconductivity. Our magnetic penetration depth measurements reveal that with increasing impurities, an anisotropic fully-gapped state changes to an isotropic full-gap state without passing through a nodal state. Furthermore, transport measurements under pressure show that the double superconducting dome in the pressure-temperature phase diagram survives against sufficient impurities. These results support that CsV3Sb5 is a non-chiral, anisotropic s-wave superconductor with no sign change both at ambient and under pressure.

7.
Nat Commun ; 14(1): 955, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36804939

RESUMO

Proton-boron (p11B) fusion is an attractive potential energy source but technically challenging to implement. Developing techniques to realize its potential requires first developing the experimental capability to produce p11B fusion in the magnetically-confined, thermonuclear plasma environment. Here we report clear experimental measurements supported by simulation of p11B fusion with high-energy neutral beams and boron powder injection in a high-temperature fusion plasma (the Large Helical Device) that have resulted in diagnostically significant levels of alpha particle emission. The injection of boron powder into the plasma edge results in boron accumulation in the core. Three 2 MW, 160 kV hydrogen neutral beam injectors create a large population of well-confined, high -energy protons to react with the boron plasma. The fusion products, MeV alpha particles, are measured with a custom designed particle detector which gives a fusion rate in very good relative agreement with calculations of the global rate. This is the first such realization of p11B fusion in a magnetically confined plasma.

8.
Rev Sci Instrum ; 93(9): 093504, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182517

RESUMO

The perpendicular line-of-sight compact neutron emission spectrometer (perpendicular CNES) was newly installed to understand the helically trapped fast-ion behavior through deuterium-deuterium (D-D) neutron energy spectrum measurement in the Large Helical Device (LHD). The energy calibration of the EJ-301 liquid scintillation detector system for perpendicular CNES was performed on an accelerator-based D-D neutron source. We installed two EJ-301 liquid scintillation detectors, which view the LHD plasma vertically from the lower side through the multichannel collimator. The D-D neutron energy spectrum was measured in a deuterium perpendicular-neutral-beam-heated deuterium plasma. By the derivative unfolding technique, it was found that the D-D neutron energy spectrum had a double-humped shape with peaks at ∼2.33 and ∼2.65 MeV. D-D neutron energy spectrum was calculated based on the fast ion distribution function using guiding center orbit-following models considering the detector's energy resolution. The calculated peak energies in the D-D neutron energy spectrum almost match the experiment. In addition, a feasibility study toward the measurement of the energy distribution of ion-cyclotron-range-of-frequency-wave-accelerated beam ions was performed.

9.
Science ; 375(6584): 1011-1016, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35143255

RESUMO

The Hayabusa2 spacecraft investigated the C-type (carbonaceous) asteroid (162173) Ryugu. The mission performed two landing operations to collect samples of surface and subsurface material, the latter exposed by an artificial impact. We present images of the second touchdown site, finding that ejecta from the impact crater was present at the sample location. Surface pebbles at both landing sites show morphological variations ranging from rugged to smooth, similar to Ryugu's boulders, and shapes from quasi-spherical to flattened. The samples were returned to Earth on 6 December 2020. We describe the morphology of >5 grams of returned pebbles and sand. Their diverse color, shape, and structure are consistent with the observed materials of Ryugu; we conclude that they are a representative sample of the asteroid.

10.
Rev Sci Instrum ; 92(5): 053524, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243281

RESUMO

The fast deuteron (non-Maxwellian component) diagnostic method, which is based on the higher resolution optical spectroscopic measurement, has been developed as a powerful tool. Owing to a decrease in the D-H charge-exchange cross section, the diagnostic ability of conventional optical diagnostic methods should be improved for ∼MeV energy deuterons. Because the 3He-H charge-exchange cross section is much larger than that of D-H in the ∼MeV energy range, the visible light (VIS) spectrum of 3He produced by the dueteron-dueteron (DD) reaction may be a useful tool. Although the density of 3He is small because it is produced via the DD reaction, improvement of the emissivity of the VIS spectrum of 3He can be expected by using a high-energy beam. We evaluate the VIS spectrum of 3He for the cases when a fast deuteron tail is formed and not formed in the ITER-like beam injected deuterium plasma. Even when the beam energy is in the MeV energy range, a large change appears in the half width at half maximum of the VIS spectrum. The emissivity of the VIS spectrum of 3He and the emissivity of bremsstrahlung are compared, and the measurable VIS spectrum is obtained. It is shown that the VIS spectrum of 3He is a useful tool for the MeV beam deuteron tail diagnostics.

11.
Res Vet Sci ; 137: 208-216, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34020336

RESUMO

The present study aimed to verify the changes in the expression levels of 13 candidate genes associated with chemotherapy resistance and to construct a scoring system to predict resistance to these drugs. The expression levels of the 13 candidate genes were compared between 20 dogs with lymphoma that were sensitive to drugs used in CHOP-based protocol and 16 dogs with lymphoma that were resistant to these drugs. The expression levels of six genes; ASNS, CCR3, CALCA, FCER1A, LOC448801, and EDNRB were significantly different between the two groups. A scoring system to predict resistance to cyclophosphamide, doxorubicin and vincristine, which are used in CHOP-based protocol, was constructed based on expression levels of the six genes in these 36 dogs using logistic regression models. After internal validation, sensitivity and specificity of the scoring system were 0.759 and 0.853, respectively. External validation was conducted in another cohort of 33 dogs with lymphoma, and sensitivity and specificity of the scoring system were 0.800 and 0.696, respectively. In conclusion, this study identified six genes associated with resistance to drugs used in CHOP-based protocol in canine lymphoma and proposed a novel scoring system to predict resistance to these drugs. This system might be beneficial in selecting the most appropriate chemotherapy protocol for individual dogs with lymphoma.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Doenças do Cão/tratamento farmacológico , Resistencia a Medicamentos Antineoplásicos/genética , Linfoma/veterinária , Transcriptoma , Animais , Estudos de Coortes , Ciclofosfamida/uso terapêutico , Cães , Doxorrubicina/uso terapêutico , Feminino , Linfoma/tratamento farmacológico , Masculino , Prednisona/uso terapêutico , Projetos de Pesquisa , Vincristina/uso terapêutico
12.
Acta Otolaryngol ; 141(1): 10-13, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32921218

RESUMO

BACKGROUND: During stapes surgery, the Teflon wire piston prosthesis is prone to postoperative 'slips' and subsequent necrosis and fracture of the long process of the incus. AIMS/OBJECTIVE: We invented and used a novel cup-shaped apatite prosthesis to reduce the incidence of necrosis of the long process of the incus and analysed the postoperative results. MATERIAL AND METHODS: Thirty-one ears in 25 patients with otosclerosis who underwent stapes surgery with our apatite prosthesis were evaluated. RESULTS: The air conduction improved by 24.0 dB (the average) from pre- to post-operation. Additionally, 84.8% of patients achieved an air-bone gap of ≤10 dB for the 4-frequency measurements (p < .01). CONCLUSIONS: Our findings indicate that our new prosthesis was associated with a good postoperative prognosis in patients with otosclerosis. SIGNIFICANCE: Our unique prosthesis yielded good outcomes for the treatment of otosclerosis even in the short term.


Assuntos
Condução Óssea/fisiologia , Microcirurgia/métodos , Prótese Ossicular , Otosclerose/cirurgia , Cirurgia do Estribo/métodos , Estribo , Feminino , Seguimentos , Audição , Humanos , Masculino , Pessoa de Meia-Idade , Otosclerose/fisiopatologia , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo
13.
Rev Sci Instrum ; 91(11): 113304, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33261440

RESUMO

A diamond-based neutral particle analyzer (DNPA) array composed of single-crystal chemical vapor deposition (sCVD) diamond detectors was installed on the Large Helical Device (LHD) for measuring the helically trapped energetic particles. In high neutron flux experiments, the unwanted neutron-induced pulse counting rate should be estimated using the neutron diagnostics because a diamond detector is sensitive to neutrons as well as energetic neutral particles. In order to evaluate the quantitative neutron-induced pulse counting rate on the DNPA, the response functions of the sCVD diamond detector for mono-energetic neutrons were obtained using accelerator-based D-D and D-7Li neutron sources in Fast Neutron Laboratory (FNL). As a result of the neutron flux estimation by the Monte Carlo N-Particle code at the NPA position in the LHD and the response function obtained in the FNL experiment, the counting rate of the neutron-induced signal was predicted to be 1.1 kcps for the source neutron emission rate of Sn = 1 × 1015 n/s. In the LHD experiment, the neutron-induced signals were observed by closing the gate valve during the plasma discharges. It is found that the counting rates of the neutron-induced signals proportional to Sn reached 1.1 kcps at Sn = 1 × 1015 n/s. As a result of the quantitative estimation of the neutron-induced signals on the DNPA using other neutron measurements, it has become possible to accurately measure energetic neutral particles in the high neutron flux experiment.

14.
Rev Sci Instrum ; 91(11): 113504, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33261467

RESUMO

Materials and structures of a collimator for a new neutron emission profile monitor in JT-60SA are examined through Monte Carlo simulations using the Monte Carlo N-Particle transport code. First, the shielding properties of various material combinations are compared in order to determine a combination with high shielding performances against both neutrons and gamma-rays. It is found that a collimator consisting of borated polyethylene and lead has a high shielding performance against neutrons. Moreover, a high shielding performance against gamma-rays is obtained when a lead pipe with a radial thickness of 0.01 m is inserted into a collimation tube. Second, we demonstrate that it is possible to improve the spatial resolution to a desired level by installing a thin tubular extension structure that fits into the limited space available between the main collimator block and the tokamak device. Finally, the collimator structures that meet both the targeted spatial resolutions (<10% of the plasma minor radius) and the targeted counting rate (105 cps order) are discussed.

15.
Rev Sci Instrum ; 91(8): 083505, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872928

RESUMO

Two new vertical neutron cameras characterized by high detection efficiency were developed on the Large Helical Device in order to observe poloidal structures of helically trapped beam ions created by the perpendicularly injected positive-ion based neutral beam (P-NB) and are newly operated since 2018. In this work, the neutron fields at the vertical neutron cameras are investigated using the Monte Carlo N-particle transport code to evaluate the performance of its collimators. The results indicate that neutrons are attenuated by the heavy concrete and are well collimated through the collimator to detectors. Neutron spectra at the detector position show over 99% of uncollided 2.45 MeV neutrons. Time evolution of neutron emission profiles during the short pulse of P-NB injection is measured by the vertical neutron cameras. Peaks on the neutron emission profiles corresponding to the helically trapped beam ion are successfully obtained, as designed. The decrease in line integrated neutron flux at the peak positions after the P-NB stops is consistent with the behavior of the total neutron emission rate measured by the neutron flux monitor.

16.
Science ; 368(6491): 654-659, 2020 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-32381723

RESUMO

The near-Earth asteroid (162173) Ryugu is thought to be a primitive carbonaceous object that contains hydrated minerals and organic molecules. We report sample collection from Ryugu's surface by the Hayabusa2 spacecraft on 21 February 2019. Touchdown images and global observations of surface colors are used to investigate the stratigraphy of the surface around the sample location and across Ryugu. Latitudinal color variations suggest the reddening of exposed surface material by solar heating and/or space weathering. Immediately after touchdown, Hayabusa2's thrusters disturbed dark, fine grains that originate from the redder materials. The stratigraphic relationship between identified craters and the redder material indicates that surface reddening occurred over a short period of time. We suggest that Ryugu previously experienced an orbital excursion near the Sun.

17.
Clin Exp Dermatol ; 45(8): 1055-1058, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32460367

RESUMO

Epidermal growth factor receptor inhibitors (EGFRIs) frequently cause cutaneous adverse effects such as papulopustular eruptions. However, the mechanism of the reactions remains unclear. To assess the pathological mechanism of cutaneous adverse reactions caused by EGFRIs, we investigated whether EGFRIs have an influence on the innate immune response of the skin. Levels of human ß-defensins (hBDs), which serve as the first line of defence against infection by pathogenic microorganisms, in the stratum corneum samples of patients treated with EGFR. monoclonal antibodies were measured before and after starting therapy. There were no obvious trends in hBD production in patients without eruptions, whereas a significant decrease in hBD1 and hBD3 production and a nonsignficant decrease in hBD2 production were observed in patients who developed papulopustular eruptions. Our results suggest that a reduction in hBD contributes to the increased incidence of papulopustular eruptions.


Assuntos
Anticorpos Monoclonais/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Receptores ErbB/antagonistas & inibidores , beta-Defensinas/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos/análise , Anti-Infecciosos/metabolismo , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/uso terapêutico , Toxidermias/etiologia , Toxidermias/imunologia , Toxidermias/microbiologia , Epiderme/efeitos dos fármacos , Epiderme/metabolismo , Epiderme/patologia , Receptores ErbB/imunologia , Feminino , Humanos , Imunidade Inata/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Infecções Cutâneas Estafilocócicas/induzido quimicamente , Infecções Cutâneas Estafilocócicas/epidemiologia , beta-Defensinas/análise
18.
Science ; 368(6486): 67-71, 2020 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-32193363

RESUMO

The Hayabusa2 spacecraft investigated the small asteroid Ryugu, which has a rubble-pile structure. We describe an impact experiment on Ryugu using Hayabusa2's Small Carry-on Impactor. The impact produced an artificial crater with a diameter >10 meters, which has a semicircular shape, an elevated rim, and a central pit. Images of the impact and resulting ejecta were recorded by the Deployable CAMera 3 for >8 minutes, showing the growth of an ejecta curtain (the outer edge of the ejecta) and deposition of ejecta onto the surface. The ejecta curtain was asymmetric and heterogeneous and it never fully detached from the surface. The crater formed in the gravity-dominated regime; in other words, crater growth was limited by gravity not surface strength. We discuss implications for Ryugu's surface age.

19.
Scand J Surg ; 109(4): 301-308, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31354079

RESUMO

BACKGROUND AND AIMS: T2 gallbladder cancer requires lymph node dissection for curative resection, whereas simple cholecystectomy is adequate to treat T1 gallbladder cancer. Hence, this study aimed to develop an accurate scoring system to preoperatively predict pT2 in gallbladder cancer. MATERIAL AND METHODS: We retrospectively assessed data from 57 patients with suspected gallbladder cancer who underwent curative resection between September 2003 and May 2017. Six with apparent invasion of adjacent organs on preoperative images were excluded. We evaluated preoperative computed tomography, magnetic resonance and endoscopic ultrasonographic images, blood biochemistry, and the maximum standard uptake value in fluorodeoxyglucose-positron emission tomography images. We analyzed whether correlations between preoperative findings and the depth of tumor invasion could predict pT2. RESULTS: The pathological diagnosis was gallbladder cancer in 30 (58.8%) patients, of whom 21 (69.9%) had pT2 or worse. Multivariate analyses selected carcinoembryonic antigen and tumor diameter as independent predictors of pT2 or worse (odds ratios = 1.741 and 1.098, respectively; 95% confidence intervals = 1.004-3.020 and 1.008-1.197, respectively). A regression formula was created using carcinoembryonic antigen and tumor diameter to calculate pT2 predictive scores. The area under the receiver operating characteristics curve of the pT2 predictive score was 0.873. CONCLUSION: We created a scoring system to predict pT2 in gallbladder cancer using carcinoembryonic antigen and tumor diameter. The present findings suggested that carcinoembryonic antigen is important for the preoperative evaluation of gallbladder cancer.


Assuntos
Adenocarcinoma/sangue , Adenocarcinoma/patologia , Antígeno Carcinoembrionário/sangue , Neoplasias da Vesícula Biliar/sangue , Neoplasias da Vesícula Biliar/patologia , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Colecistectomia , Feminino , Neoplasias da Vesícula Biliar/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
20.
Phys Rev Lett ; 123(12): 126602, 2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31633958

RESUMO

We have discovered room-temperature low-field colossal magnetoresistance (CMR) in an A-site ordered NdBaMn_{2}O_{6} crystal. The resistance changes more than 2 orders of magnitude at a magnetic field lower than 2 T near 300 K. When the temperature and magnetic field sweep from an insulating (metallic) phase to a metallic (insulating) phase, the insulating (metallic) conduction changes to the metallic (insulating) conduction within 1 K and 0.5 T, respectively. The CMR is ascribed to the melting of the charge and orbital ordering. The entropy change which is estimated from the B-T phase diagram is smaller than what is expected for the charge and orbital ordering. The suppression of the entropy change is attributable to the loss of the short-range ferromagnetic fluctuation of Mn spin moments, which is an important key of the high temperature and low magnetic field CMR effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...