Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Int Adv Otol ; 18(1): 88-91, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35193853

RESUMO

Transcanal endoscopic ear surgery (TEES) provides wide-angle clear vision for otologic surgery. We report the utility of TEES with the mirror technique for the complete removal of a congenital cholesteatoma in a 3-year-old boy. A white mass was observed through the tympanic membrane, and a congenital cholesteatoma was suspected during the conservative treatment of otitis media with effusion. Pre-operative computed tomography (CT) revealed an irregular mass lesion in the left middle ear, with bone erosion in the hypotympanum. During surgery, an open-type cholesteatoma was observed, mainly in the middle lower tympanum. The cholesteatoma had destroyed the periphery of the temporomandibular joint, which was widely exposed. The cholesteatoma had also spread to the tympanic sinus. Careful observation with a forward-oblique viewing endoscope and a variable angle tympanic mirror enabled complete removal of the mass under endoscopic guidance. No recurrence was observed during the postoperative follow-up, although residual open-type congenital cholesteatoma may often result in recurrence. We believe that careful removal of the lesion under TEES, which allowed us to perform surgery under a secure view with illumination and magnification, may have facilitated complete removal and prevented recurrence.


Assuntos
Colesteatoma da Orelha Média , Procedimentos Cirúrgicos Otológicos , Pré-Escolar , Colesteatoma da Orelha Média/diagnóstico por imagem , Colesteatoma da Orelha Média/cirurgia , Orelha Média/diagnóstico por imagem , Orelha Média/cirurgia , Endoscopia/métodos , Humanos , Masculino , Procedimentos Cirúrgicos Otológicos/métodos , Estudos Retrospectivos , Articulação Temporomandibular , Resultado do Tratamento
2.
J Int Adv Otol ; 17(3): 269-274, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34100755

RESUMO

Primary intraosseous cavernous hemangiomas (PICHs) in the temporal bone are very rare. Most treated cases are in adult patients, and there are very few reports involving children. To our knowledge, no cases reported have ever actually adopted embolization in children, although several reports recommend preoperative embolization of the feeding arteries. Here, we present a case of a child with a large cavernous hemangioma developing in the temporal bone. The patient was an 11-year-old girl whose chief complaints were hearing loss, aural fullness, and otalgia. Based on imaging, a lymphoma was initially suspected, but extensive arterial bleeding occurred during biopsy under local anesthesia. Angiography was performed to evaluate the blood flow in the tumor, and revealed the middle meningeal artery as a main feeding artery to the tumor. A huge PICH at the temporal bone was successfully resected following preoperative embolization of the feeding artery.


Assuntos
Embolização Terapêutica , Hemangioma Cavernoso , Criança , Feminino , Hemangioma Cavernoso/terapia , Humanos , Osso Temporal
3.
Anal Chem ; 77(13): 4228-34, 2005 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15987131

RESUMO

We demonstrated the discrimination of volatile sulfur compound mixtures with different mixing ratios by using an array of the plasma-polymerized film (PPF)-coated quartz crystal resonators. The PPF sensor array, which contains PPFs prepared from amino acids and synthetic polymers, exhibited different response patterns to mono or mixed volatile sulfur compounds (VSCs) (hydrogen sulfide and methanethiol) under a dry environment. The sensor array was installed in a desktop-size relative humidity controller. The relative humidity and temperature conditions of the sample flow to the sensor cell were equalized to those of the inner atmosphere of the sensor cell based on the concept of the two-separate-temperatures method. In this way, the baseline drift of PPF sensor response caused by the introduction of a highly humid sample was successfully suppressed. We compared the sensor array responses under the controlled humidity conditions. Presorption of water molecules by PPFs caused a decrease of sensor sensitivity, but the films still had the ability to discriminate sub-ppmv VSC mixtures having 6:1, 1:1, and 1:6 mixture ratios of hydrogen sulfide and methanethiol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...