Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 13(12): 8132-8143, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106283

RESUMO

Background: Meningiomas are the most common primary central nervous system tumors, and magnetic resonance imaging (MRI), especially contrast-enhanced T1 weighted image (CE T1WI), is used as a fundamental imaging modality for the detection and analysis of the tumors. In this study, we propose an automated deep-learning model for meningioma detection using the dural tail sign. Methods: The dataset included 123 patients with 3,824 dural tail signs on sagittal CE T1WI. The dataset was divided into training and test datasets based on specific time point, and 78 and 45 patients were comprised for the training and test dataset, respectively. To compensate for the small sample size of the training dataset, 39 additional patients with 69 dural tail signs from the open dataset were appended to the training dataset. A You Only Look Once (YOLO) v4 network was trained with sagittal CE T1WI to detect dural tail signs. The normal group dataset, comprised of 51 patients with no abnormal finding on MRI, was employed to evaluate the specificity of the trained model. Results: The sensitivity and false positive average were 82.22% and 29.73, respectively, in the test dataset. The specificity and false positive average were 17.65% and 3.16, respectively, in the normal dataset. Most of the false-positive cases in the test dataset were enhancing vessels, misinterpreted as dural thickening. Conclusions: The proposed model demonstrates an automated detection system for the dural tail sign to identify meningioma in general screening MRI. Our model can facilitate and alleviate radiologists' reading process by notifying the possibility of incidental dural mass based on dural tail sign detection.

2.
Korean J Radiol ; 24(7): 698-714, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37404112

RESUMO

In recent years, artificial intelligence, especially object detection-based deep learning in computer vision, has made significant advancements, driven by the development of computing power and the widespread use of graphic processor units. Object detection-based deep learning techniques have been applied in various fields, including the medical imaging domain, where remarkable achievements have been reported in disease detection. However, the application of deep learning does not always guarantee satisfactory performance, and researchers have been employing trial-and-error to identify the factors contributing to performance degradation and enhance their models. Moreover, due to the black-box problem, the intermediate processes of a deep learning network cannot be comprehended by humans; as a result, identifying problems in a deep learning model that exhibits poor performance can be challenging. This article highlights potential issues that may cause performance degradation at each deep learning step in the medical imaging domain and discusses factors that must be considered to improve the performance of deep learning models. Researchers who wish to begin deep learning research can reduce the required amount of trial-and-error by understanding the issues discussed in this study.


Assuntos
Inteligência Artificial , Aprendizado Profundo , Humanos , Algoritmos
3.
Front Aging Neurosci ; 15: 1291376, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38161586

RESUMO

Introduction: Alzheimer's disease (AD) presents typically gray matter atrophy and white matter abnormalities in neuroimaging, suggesting that the gray-white matter boundary could be altered in individuals with AD. The purpose of this study was to explore differences of gray-white matter boundary Z-score (gwBZ) and its tissue volume (gwBTV) between patients with AD, amnestic mild cognitive impairment (MCI), and cognitively normal (CN) elderly participants. Methods: Three-dimensional T1-weight images of a total of 227 participants were prospectively obtained from our institute from 2006 to 2022 to map gwBZ and gwBTV on images. Statistical analyses of gwBZ and gwBTV were performed to compare the three groups (AD, MCI, CN), to assess their correlations with age and Korean version of the Mini-Mental State Examination (K-MMSE), and to evaluate their effects on AD classification in the hippocampus. Results: This study included 62 CN participants (71.8 ± 4.8 years, 20 males, 42 females), 72 MCI participants (72.6 ± 5.1 years, 23 males, 49 females), and 93 AD participants (73.6 ± 7.7 years, 22 males, 71 females). The AD group had lower gwBZ and gwBTV than CN and MCI groups. K-MMSE showed positive correlations with gwBZ and gwBTV whereas age showed negative correlations with gwBZ and gwBTV. The combination of gwBZ or gwBTV with K-MMSE had a high accuracy in classifying AD from CN in the hippocampus with an area under curve (AUC) value of 0.972 for both. Conclusion: gwBZ and gwBTV were reduced in AD. They were correlated with cognitive function and age. Moreover, gwBZ or gwBTV combined with K-MMSE had a high accuracy in differentiating AD from CN in the hippocampus. These findings suggest that evaluating gwBZ and gwBTV in AD brain could be a useful tool for monitoring AD progression and diagnosis.

4.
Sci Rep ; 12(1): 19503, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36376364

RESUMO

Brain metastases (BM) are the most common intracranial tumors, and their prevalence is increasing. High-resolution black-blood (BB) imaging was used to complement the conventional contrast-enhanced 3D gradient-echo imaging to detect BM. In this study, we propose an efficient deep learning algorithm (DLA) for BM detection in BB imaging with contrast enhancement scans, and assess the efficacy of an automatic detection algorithm for BM. A total of 113 BM participants with 585 metastases were included in the training cohort for five-fold cross-validation. The You Only Look Once (YOLO) V2 network was trained with 3D BB sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) images to investigate the BM detection. For the observer performance, two board-certified radiologists and two second-year radiology residents detected the BM and recorded the reading time. For the training cohort, the overall performance of the five-fold cross-validation was 87.95%, 24.82%, 19.35%, 14.48, and 18.40 for sensitivity, precision, F1-Score, the false positive average for the BM dataset, and the false positive average for the normal individual dataset, respectively. For the comparison of reading time with and without DLA, the average reading time was reduced by 20.86% in the range of 15.22-25.77%. The proposed method has the potential to detect BM with a high sensitivity and has a limited number of false positives using BB imaging.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Humanos , Algoritmos , Neoplasias Encefálicas/secundário , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos
5.
Eur J Radiol ; 154: 110369, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35691109

RESUMO

OBJECTIVE: Mammography is the initial examination to detect breast cancer symptoms, and quality control of mammography devices is crucial to maintain accurate diagnosis and to safeguard against degradation of performance. The objective of this study was to assist radiologists in mammography phantom image evaluation by developing and validating an interpretable deep learning model capable of objectively evaluating the quality of standard phantom images for mammography. MATERIALS AND METHODS: A total of 2,208 mammography phantom images were collected for periodic accreditation of the scanner from 1,755 institutions. The dataset was randomly split into training (1,808 images) and testing (400 images) datasets with subgroups (76 images) for the multi-reader study. To develop an interpretable model that contains two deep learning networks in series, five processing steps were performed: mammography phantom detection, phantom object detection, post-processing, score evaluation, and a report with a comment about ambiguous results. RESULTS: For phantom detection, the accuracy and mean intersection over union (mIOU) were 1.00 and 0.938 in the test dataset, respectively. During phantom object detection, a total of 6,369 out of 6,400 objects were detected as the correct object class, and the accuracy and mIOU were 0.995 and 0.813, respectively. The predicted score for each object showed a consensus of 97.40% excluding ambiguous points and 59.10% for ambiguous points of the groups. CONCLUSIONS: The interpretable deep learning model using large-scale data from multiple centers shows high performance and reasonable object scoring, successfully validating the reliability and feasibility of mammography phantom image quality management.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Mamografia/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Raios X
6.
Artigo em Inglês | MEDLINE | ID: mdl-35409882

RESUMO

This study aims to examine sex-specific differences in body composition and lower extremity fat distribution and their association with physical performance among healthy older adults. The pilot study comprises 40 subjects (20 men and 20 women) matched by age and body mass index. The participants undergo dual-energy X-ray absorptiometry, magnetic resonance imaging, and proton magnetic resonance spectroscopy (1H-MRS) to assess body composition and lower extremity fat distribution. 1H-MRS is used to measure the extramyocellular lipid (EMCL) and intramyocellular lipid (IMCL) contents of the lower leg muscles (soleus and tibialis anterior) at the maximum circumference of the calf after overnight fasting. The tibialis anterior IMCL, as assessed by 1H-MRS, is negatively associated with the five-times sit-to-stand test scores (rs = 0.518, p = 0.023) in men, while the soleus IMCL content is negatively associated with the timed up-and-go test scores (rs = 0.472, p = 0.048) in women. However, the soleus EMCL content is positively associated with the five-times sit-to-stand test scores (rs = -0.488, p = 0.040) in women, but this association is not statistically significant in men. This study shows an inverse correlation between IMCL content and physical performance in healthy older individuals and lower leg muscle-specific IMCL based on sex differences. Furthermore, our results suggest that greater EMCL content in the soleus and calf subcutaneous fat might affect physical performance positively in women but not men.


Assuntos
Vida Independente , Caracteres Sexuais , Idoso , Distribuição da Gordura Corporal , Feminino , Humanos , Lipídeos , Masculino , Desempenho Físico Funcional , Projetos Piloto
7.
Yonsei Med J ; 62(12): 1125-1135, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34816643

RESUMO

PURPOSE: This study aimed to propose an effective end-to-end process in medical imaging using an independent task learning (ITL) algorithm and to evaluate its performance in maxillary sinusitis applications. MATERIALS AND METHODS: For the internal dataset, 2122 Waters' view X-ray images, which included 1376 normal and 746 sinusitis images, were divided into training (n=1824) and test (n=298) datasets. For external validation, 700 images, including 379 normal and 321 sinusitis images, from three different institutions were evaluated. To develop the automatic diagnosis system algorithm, four processing steps were performed: 1) preprocessing for ITL, 2) facial patch detection, 3) maxillary sinusitis detection, and 4) a localization report with the sinusitis detector. RESULTS: The accuracy of facial patch detection, which was the first step in the end-to-end algorithm, was 100%, 100%, 99.5%, and 97.5% for the internal set and external validation sets #1, #2, and #3, respectively. The accuracy and area under the receiver operating characteristic curve (AUC) of maxillary sinusitis detection were 88.93% (0.89), 91.67% (0.90), 90.45% (0.86), and 85.13% (0.85) for the internal set and external validation sets #1, #2, and #3, respectively. The accuracy and AUC of the fully automatic sinusitis diagnosis system, including site localization, were 79.87% (0.80), 84.67% (0.82), 83.92% (0.82), and 73.85% (0.74) for the internal set and external validation sets #1, #2, and #3, respectively. CONCLUSION: ITL application for maxillary sinusitis showed reasonable performance in internal and external validation tests, compared with applications used in previous studies.


Assuntos
Aprendizado Profundo , Sinusite Maxilar , Humanos , Sinusite Maxilar/diagnóstico por imagem , Curva ROC , Radiografia , Estudos Retrospectivos
8.
Curr Alzheimer Res ; 18(4): 335-346, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34238193

RESUMO

BACKGROUND: Longitudinal changes of brain metabolites during a functional stimulation are unknown in amnestic mild cognitive impairment (aMCI) and Alzheimer's disease (AD) subjects. OBJECTIVE: This study was to evaluate the longitudinal changes of brain metabolites using proton magnetic resonance spectroscopy (1H MRS) in response to treatment during a memory task in the subjects of cognitive normal (CN), aMCI, and AD. METHODS: We acquired functional magnetic resonance spectroscopy (fMRS) data from 28 CN elderly, 16 aMCI and 12 AD subjects during a face-name association task. We measured fMRS metabolite ratios over 24 months in the 8-month apart, determined the temporal changes of the metabolites, and evaluated the differences among the three groups under the three different conditions (base, novel, repeat). RESULTS: The results of comparisons for the three subject groups and the three-time points showed that tNAA/tCho and tCr/tCho were statistically significant among the three subject groups in any of the three conditions. The dynamic temporal change measurements for the metabolites for each condition showed that Glx/tCho and Glu/tCho levels at the third visit increased significantly compared with in the first visit in the novel condition in the AD group. CONCLUSION: We found declines in tNAA/tCho and tCr/tCho in the aMCI and AD subjects with increasing disease severity, being highest in CN and lowest in AD. The Glx/tCho level increased temporally in the AD subjects after they took an acetylcholine esterase inhibitor. Therefore, Glx may be suitable to demonstrate functional recovery after treatment.


Assuntos
Doença de Alzheimer/metabolismo , Encéfalo/metabolismo , Disfunção Cognitiva/metabolismo , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
9.
J Stroke Cerebrovasc Dis ; 30(9): 105886, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34175642

RESUMO

PURPOSE: Cerebral microbleeds (CMBs) are considered essential indicators for the diagnosis of cerebrovascular disease and cognitive disorders. Traditionally, CMBs are manually interpreted based on criteria including the shape, diameter, and signal characteristics after an MR examination, such as susceptibility-weighted imaging or gradient echo imaging (GRE). In this paper, an efficient method for CMB detection in GRE scans is presented. MATERIALS AND METHODS: The proposed framework consists of the following phases: (1) pre-processing (skull extraction), (2) the first training with the ground truth labeled using CMB, (3) the second training with the ground truth labeled with CMB mimicking the same subjects, and (4) post-processing (cerebrospinal fluid (CSF) filtering). The proposed technique was validated on a dataset of 1133 CBMs that consisted of 5284 images for training and 1737 images for testing. We applied a two-stage approach using a region-based CNN method based on You Only Look Once (YOLO) to investigate a novel CMB detection technique. RESULTS: The sensitivity, precision, F1-score and false positive per person (FPavg) were evaluated as 80.96, 60.98, 69.57 and 6.57, 59.69, 62.70, 61.16 and 4.5, 66.90, 79.75, 72.76 and 2.15 for YOLO with a single label, YOLO with double labels, and YOLO + CSF filtering, respectively, and YOLO + CSF filtering showed the highest precision performance, F1-score and lowest FPavg. CONCLUSIONS: Using proposed framework, we developed an optimized CMB learning model with low false positives and a balanced performance in clinical practice.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Neurobiol Aging ; 69: 48-57, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29852410

RESUMO

We investigated both independent and interconnected effects of 3 lifestyle factors on brain volume, measuring yearly changes using large-scale longitudinal magnetic resonance imaging, in middle-aged to older adults. We measured brain volumes in a cohort (n = 984, 49-79 years) from the Korean Genome and Epidemiology Study group, using baseline and follow-up estimates after 4 years. In our analysis, the accelerated brain atrophy in normal aging was observed across regions (e.g., brain tissue: -0.098 ± 0.01 mL/y, p < 0.001). An independent lifestyle-specific trend of brain atrophy across time was also evident in men, where smoking (p = 0.012) and physical activity (p = 0.014) showed the strongest association with the atrophy rate. Linear regression analysis of the interconnected effect revealed that brain atrophy is mitigated by intense physical activity in smoking males. Lifestyle factors did not show any significant effect on brain volume in women. These results provide important information regarding lifestyle factors that affect brain aging in mid-to-late adulthood. Our findings may aid in the identification of preventive measures against dementia.


Assuntos
Envelhecimento , Encéfalo/anatomia & histologia , Encéfalo/patologia , Estilo de Vida , Idoso , Consumo de Bebidas Alcoólicas , Atrofia , Exercício Físico , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Fumar
11.
Korean J Radiol ; 18(1): 238-248, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28096732

RESUMO

OBJECTIVE: The purpose of this study was to estimate the T2* relaxation time in breast cancer, and to evaluate the association between the T2* value with clinical-imaging-pathological features of breast cancer. MATERIALS AND METHODS: Between January 2011 and July 2013, 107 consecutive women with 107 breast cancers underwent multi-echo T2*-weighted imaging on a 3T clinical magnetic resonance imaging system. The Student's t test and one-way analysis of variance were used to compare the T2* values of cancer for different groups, based on the clinical-imaging-pathological features. In addition, multiple linear regression analysis was performed to find independent predictive factors associated with the T2* values. RESULTS: Of the 107 breast cancers, 92 were invasive and 15 were ductal carcinoma in situ (DCIS). The mean T2* value of invasive cancers was significantly longer than that of DCIS (p = 0.029). Signal intensity on T2-weighted imaging (T2WI) and histologic grade of invasive breast cancers showed significant correlation with T2* relaxation time in univariate and multivariate analysis. Breast cancer groups with higher signal intensity on T2WI showed longer T2* relaxation time (p = 0.005). Cancer groups with higher histologic grade showed longer T2* relaxation time (p = 0.017). CONCLUSION: The T2* value is significantly longer in invasive cancer than in DCIS. In invasive cancers, T2* relaxation time is significantly longer in higher histologic grades and high signal intensity on T2WI. Based on these preliminary data, quantitative T2* mapping has the potential to be useful in the characterization of breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Adulto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Invasividade Neoplásica
13.
Clin Imaging ; 40(3): 445-50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27133684

RESUMO

PURPOSE: To evaluate the potential of intravoxel incoherent motion (IVIM) imaging to predict histological prognostic parameters by investigating whether IVIM parameters correlate with Gleason score. MATERIALS AND METHODS: The institutional review board approved this retrospective study, and informed consent was waived. A total of 41 patients with histologically proven prostate cancer who underwent prostate MRI using a 3T MRI machine were included. For eight diffusion-weighted imaging b-values (0, 10, 20, 50, 100, 200, 500, and 800s/mm(2)), a spin-echo echo-planar imaging sequence was performed. D, f, D(⁎), and ADCfit values were compared among three groups of patients with prostate cancer: Gleason score 6 (n=9), 7 (n=16), or 8 or higher (n=16). Receiver operating characteristic (ROC) curves were generated for D, f, D(⁎), and ADCfit to assess the ability of each parameter to distinguish cancers with low Gleason scores from cancers with intermediate or high Gleason scores. RESULTS: Pearson's coefficient analysis revealed significant negative correlations between Gleason score and ADCfit (r=-0.490, P=.001) and Gleason score and D values (r=-0.514, P=.001). Gleason score was poorly correlated with f (r=0.168, P=.292) and D(⁎) values (r=-0.108, P=.500). The ADCfit and D values of prostate cancers with Gleason scores 7 or ≥8 were significantly lower than values for prostate cancers with Gleason score 6 (P<.05). ROC curves were constructed to assess the ability of IVIM parameters to discriminate prostate cancers with Gleason score 6 from cancers with Gleason scores 7 or ≥8. Areas under the curve were 0.671 to 0.974. ADCfit and D yielded the highest Az value (0.960-0.956), whereas f yielded the lowest Az value (0.633). CONCLUSIONS: The pure molecular diffusion parameter, D, was the IVIM parameter that best discriminated prostate cancers with low Gleason scores from prostate cancers with intermediate or high Gleason scores.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Gradação de Tumores/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Curva ROC , Estudos Retrospectivos
14.
J Alzheimers Dis ; 52(1): 145-59, 2016 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-27060946

RESUMO

BACKGROUND: The metabolite response during a memory task in Alzheimer's disease (AD) patients is unknown. OBJECTIVE: To investigate the metabolite changes in subjects with AD, amnestic mild cognitive impairment (aMCI), and cognitively normal (CN) elderly during a memory task using functional magnetic resonance spectroscopy (fMRS). METHODS: This study involved 23 young normal controls (YC), 24 CN elderly, 24 aMCI, and 24 mild and probable AD individuals. fMRS data were acquired at the precuneus and posterior cingulate brain regions during a face-name association task. Statistical analyses of quantified metabolites were performed to evaluate differences of the metabolite values between the stimulation conditions and among the four subject groups. Receiver operating curve analysis was performed to evaluate whether the metabolic changes after functional activations can differentiate the subject groups. RESULT: Glutamine and glutamate complex (Glx) was statistically significantly different between the fixation and repeat conditions in aMCI (p = 0.0492) as well as between the fixation and the novel conditions in the AD (p = 0.0412) group. The total N-acetylaspartate (tNAA) was statistically significantly different among the four subject groups in the fixation condition (DF = 3, F = 7.673, p <  0.001), the novel condition (DF = 3, F = 6.945, p <  0.001), and the repeat condition (DF = 3, F = 7.127, p <  0.001). tNAA, tCr, and mIns could be used to differentiate CN from aMCI. Furthermore, tNAA, tCr, Glx, and Glu could also differentiate CN from AD, and aMCI from AD. CONCLUSION: Glx was altered during a stimulation that may be used to evaluate neuronal dysfunction in a demented patient. tNAA and tCr were reduced in patients with AD.


Assuntos
Doença de Alzheimer/metabolismo , Encéfalo/metabolismo , Disfunção Cognitiva/metabolismo , Ácido Glutâmico/metabolismo , Glutamina/metabolismo , Reconhecimento Fisiológico de Modelo/fisiologia , Adulto , Idoso , Mapeamento Encefálico , Estudos de Coortes , Face , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Entrevista Psiquiátrica Padronizada , Nomes , Testes Neuropsicológicos , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...