Pacing Clin Electrophysiol ; 47(3): 433-436, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37221929

RESUMO

An 88-year-old Japanese woman underwent DDD pacemaker (MicroPort KORA 250 DR, V lead: VEGA R52) implantation for complete atrioventricular block. A 12-lead electrocardiogram for a routine examination showed atrial pacing within the intrinsic P wave, followed by inhibition of ventricular pacing. Pacemaker interrogation revealed no abnormalities in the basic parameters; however, ventricular pacing was inhibited by far-field sensing of intrinsic atrial waves before atrial events; type II far-field P-wave sensing. As a result, unusual atrial pacing occurred due to the pause suppression algorithm, which is the one of the functions that prevent atrial fibrillation development.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Feminino , Humanos , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Átrios do Coração , Ventrículos do Coração
2.
J Cardiol Cases ; 27(5): 212-214, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37180215

RESUMO

Belt-type ambulatory electrocardiograph (EV-201) is an arrhythmia diagnostic device that can record an electrocardiogram (ECG) for a maximum of 2 weeks. Here, we report the novel utility of EV-201 in detecting arrhythmias in two professional athletes. Treadmill exercise test and Holter ECG failed to detect arrhythmia because of insufficient exercise, electrocardiogram noise. However, by wearing EV-201 only during a marathon run, supraventricular tachycardia onset and termination were successfully detected. Throughout, both athletes were diagnosed with fast-slow atrioventricular nodal re-entrant tachycardia. Therefore, EV-201 enables long-term belt-type recording, thereby being useful in detecting tachyarrhythmias that occur infrequently and during strenuous exercises. Learning objective: Diagnosis of arrhythmias during high-intensity exercise in athletes by conventional electrocardiography is sometimes difficult due to inducibility and frequency of arrythmias or motion artifacts. The primary finding of this report is that EV-201 is useful in diagnosing such arrhythmias. The secondary finding is that fast-slow atrioventricular nodal re-entrant tachycardia is a common occurrence in arrhythmias among athletes.

3.
J Cardiol Cases ; 26(3): 208-211, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36091607

RESUMO

A three-dimensional (3D) mapping system is safe and effective for catheter ablation of incisional atrial tachycardia (IAT). Prolongation of the PR interval is occasionally observed after this procedure. Although a first-degree atrioventricular block is typically benign, an excessively prolonged PR interval can indicate a worse prognosis. Currently, a method to predict the PR interval after ablation therapy for IAT is lacking. We report the case of a 70-year-old woman with paroxysmal atrial tachycardia, in which our maneuver using a 3D mapping system and the electrophysiological findings enabled us to preoperatively predict the post-ablation PR interval. We believe that this method is useful for determining treatment strategies for IAT. Learning objective: Three-dimensional (3D) mapping systems can clearly visualize macro-reentrant circuits and enable the creation of precise ablation lines. When creating ablation lines for incisional atrial tachycardia, attention should be paid to the prolongation of the PR interval, because an excessively prolonged PR interval may indicate a worse prognosis. Herein, we have presented a method for predicting the post-ablation PR interval using a 3D mapping system and electrophysiological findings.

4.
Int Heart J ; 63(3): 498-503, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35650151

RESUMO

In terms of the pulmonary vein (PV), atrial fibrillation (AF) patients have a shorter effective refractory period (ERP) than those without AF and a large dispersion of the ERP. Although the frequency of AF from the superior vena cava (SVC) was the highest among non-PV foci, the characteristics of the ERP in the SVC (SVC-ERP) were unclear. The purpose of this study was to elucidate the relationship between SVC-ERP and the inducibility of AF after PV isolation (PVI).Consecutive 28 patients who underwent PVI were included. After successful PVI, the SVC-ERP was measured at three positions in SVC. Rapid electrical stimuli were delivered at the shortest SVC-ERP to induce AF. Patients in whom AF was induced were assigned to the SVC-induced group (SIG), and the remaining patients were the non-SVC-induced group (non-SIG). The size of the SVC sleeve was evaluated via three-dimensional electroanatomic mapping.The SIG had a significantly shorter average SVC-ERP (236.0 ± 25.2 versus 294.8 ± 36.8 ms, P < 0.001), whereas SVC-ERP dispersion was not significantly different (30.0 ± 25.4 versus 33.3 ± 20.1 ms, P = 0.56). Although the longer SVC diameter was significantly longer in the SIG (27.4 ± 4.3 versus 22.9 ± 4.6 mm, P = 0.03), the SVC-ERP was significantly associated with pacing inducibility of AF after adjustment for the longer SVC diameter (odds ratio: 0.96 [1 ms increments], P = 0.01).The SIG had a shorter SVC-ERP, whereas the dispersion was not significantly different between the two groups. The SVC-ERP can be one of the mechanisms of arrhythmogenicity for AF originating from the SVC.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Razão de Chances , Veias Pulmonares/cirurgia , Veia Cava Superior/cirurgia
5.
J Cardiol ; 80(4): 332-338, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35637122

RESUMO

BACKGROUND: The prognosis associated with right ventricular (RV) free-wall pacing is worse than that of septal pacing. Identification of the pacing site using a 12­lead electrocardiogram (ECG) is controversial and may be influenced by ECG changes within the same septal or free-wall area. The relationship between the diagnostic capabilities of ECG and pacing sites has previously been qualitatively evaluated. However, in this study, this relationship was analyzed quantitatively, and accurate evaluation of the pacing site was determined using computed tomography (CT). METHODS: Of 779 consecutive outpatients, 65 who underwent pacemaker implantation and thoracic CT were prospectively included and classified into the following groups according to the lead tip position: free-wall, septal, or septum/free-wall boundary (hinge) group. The hinge was used as an anatomical marker, and the distance from the hinge to the lead tip was measured. Under RV pacing, a 12­lead ECG was obtained. ECG findings were evaluated using three criteria (including lead I, II, and aVL and precordial leads V5 and V6) previously reported to be useful in differentiating pacing sites. RESULTS: The lead tips were anchored at the free-wall in 10 patients, the septal wall in 19 patients, and the hinge in 32 patients. Paced QRS duration correlated with the distance from the hinge to the lead tip for the free-wall and septum (r = 0.47 and - 0.68, respectively). Estimation of the lead tip implantation site using the ECG algorithm was useful; however, the algorithm's accuracy decreased around the hinge. CONCLUSIONS: ECG is useful in differentiating pacing sites but is less accurate around the hinge, which may be the reason that the identification of the RV pacing site using ECG remains controversial.


Assuntos
Marca-Passo Artificial , Septo Interventricular , Algoritmos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X/métodos
6.
Pacing Clin Electrophysiol ; 45(3): 297-301, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35172014

RESUMO

BACKGROUND: The displacement of cardiac implantable electronic devices (CIEDs) toward the caudal side during standing after CIED implantation could cause lead dislodgement. This study investigated the relationship between supine pocket position and standing CIEDs' displacement distance after the implantation. METHODS: After CIED surgeries performed at 2 hospitals between 2012 and 2020, 134 patients underwent postoperative chest x-rays in the supine and standing positions during hospitalization. To measure the displacement distance of CIEDs from the supine to the standing position, we identified the first thoracic vertebrae (Th1) in the supine position using the first rib as an index, drew a horizontal line at the lower edge of the Th1, and calculated the distance from that point to the upper edge of the CIED. The difference between measures for the two positions was compared. At the position of the pocket in the thorax in the supine position, the ratio of the distance between the thorax and the device is defined as the device thorax ratio (DTR). We examined the relationship between DTR and CIED displacement distance. RESULTS: In this study, we included 134 patients (53% men; median age, 79 years, body mass index, 22.3 ± 3.4; pacemaker 93%, left implantation 96%). We found that the more lateral the position of the CIED pocket, the more the CIED fell when standing (confidence interval = 0.34-0.60, P < .001). CONCLUSIONS: The farther the CIED was implanted outside the thorax in the supine position, the more significantly the CIED was displaced in the standing position.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Posição Ortostática , Tórax
7.
Pacing Clin Electrophysiol ; 45(3): 431-434, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34752651

RESUMO

An 84-year-old woman with type B Wolff-Parkinson-White (WPW) with Ebstein anomaly was admitted with heart failure. She had rapid wide QRS tachycardia due to accessory pathway (AP) conduction associated with atrial fibrillation (AF). Since transesophageal echocardiography before catheter ablation showed a left atrial thrombus, ablation was performed using a 3D mapping system under AF. After marking the functional tricuspid anulus with intra-cardiac echocardiography, 3D intra-cardiac electrogram visualization (ripple map) during AF enabled clear identification of location of the AP. After ablation, there was no complication of cerebral infarction, and the heart failure improved.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Anomalia de Ebstein , Insuficiência Cardíaca , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/complicações , Feixe Acessório Atrioventricular/cirurgia , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Anomalia de Ebstein/complicações , Anomalia de Ebstein/cirurgia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/complicações , Humanos , Síndrome de Wolff-Parkinson-White/complicações , Síndrome de Wolff-Parkinson-White/cirurgia
8.
Pacing Clin Electrophysiol ; 45(3): 435-438, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34793604

RESUMO

A 74-year-old man experienced complete atrioventricular (AV) block 2 days after catheter ablation for right atrial (RA) macroreentrant tachycardia. We performed DDD pacemaker implantation with atrial septal pacing because other sites of pacing threshold were not acceptable. The maximum left ventricular outflow tract velocity time integral was 15.8 cm with sensed AV delay (40 ms) and 15.0 cm with paced AV delay (220 ms); however, this exceeded the pacemaker's maximum difference of 100 ms. We herein report the case of a large discrepancy in optimal AV delay intervals between sensed and paced atrial events, requiring consideration of proper pacemaker settings.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Idoso , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Átrios do Coração , Humanos , Masculino
9.
J Cardiol Cases ; 24(6): 303-306, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34917216

RESUMO

An 83-year-old man with no structural heart disease underwent pulmonary vein isolation (PVI) for symptomatic paroxysmal atrial fibrillation (AF). The PVI was successfully performed by cryoballoon ablation with a single transseptal puncture. A 12Fr deflectable sheath and an 8.5Fr long sheath crossed the interatrial septum via the same puncture site. Five months after PVI, the patient was readmitted because of heart failure and recurrence of AF. The echocardiogram showed a large (10.7 × 5.8 mm) iatrogenic atrial septal defect (IASD) at the previous puncture site. Both right-to-left and left-to-right shunts were observed during systole and diastole, respectively. Despite the initiation of optimal medical therapy for heart failure, symptoms were not completely controlled and IASD remained 11 months after PVI. Eventually, he received multiple additional PVI for recurrence of AF and percutaneous transcatheter closure (13 mm disc for 10.9 × 8.9 mm- IASD), then heart failure was controlled with the improvement of the right atrial and ventricular size. Although the induction of heart failure by IASD after PVI is rare, it should be noted as one of the causes, especially after cryoballoon ablation with simultaneous mapping catheter insertion via a single transseptal puncture. .

10.
BMJ Open ; 11(12): e047932, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34872993

RESUMO

OBJECTIVES: The prevention and improvement of the prognosis of out-of-hospital cardiac arrests (OHCAs) are important issues especially with respect to their social and economic significance in working populations. The age distribution of the working population in Japan is expected to change continually due to its ageing society and extension of retirement; however, few reports have examined the long-term condition of OHCA in the working population, defined by age. The aim of this study was to determine the incidence of OHCAs and the survival rates after 1 month, among the Japanese working population, defined by age, considering the changing age distribution. DESIGN AND SETTING: We analysed the All-Japan Utstein registry, a prospective, nationwide, population-based, observational registry (2005-2016). PARTICIPANTS: From the registry, 212 961 patients with OHCA from the Japanese working population (defined aged 20-69 years), with only cardiogenic aetiology participated in this study. These patients were further divided into four groups according to the type of citizen bystander (family, friends, work-colleagues and passers-by). PRIMARY AND SECONDARY OUTCOME MEASURES: The main outcomes were 1-month survival with favourable neurological outcomes. RESULTS: The incidence of OHCAs, in any age group, was almost constant during the 12-year period. The work-colleagues had the best prognosis despite having significantly longer times to initial defibrillations compared with the passers-by (13 vs 12 min, respectively, p<0.001) that was associated independently with 1-month survival with favourable neurological outcomes (adjusted OR: 0.94 (1 min increments), p<0.001). CONCLUSIONS: In the 12-year period, the incidence of OHCAs in any age group remained almost constant, whereas the prognosis improved each year. Reducing the time to initial defibrillation may further improve the prognosis of OHCAs with a work-colleague bystander.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Adulto , Idoso , Reanimação Cardiopulmonar/métodos , Estudos de Coortes , Humanos , Incidência , Japão/epidemiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Taxa de Sobrevida , Adulto Jovem
11.
J Cardiovasc Electrophysiol ; 32(11): 3103-3106, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34460986

RESUMO

Adenosine can hyperpolarize the atrial action potential, which helps rapidly re-establish the membrane potential in ablated sites and unmask "dormant conduction." It has been reported that pharmacological agents, including adenosine, were unable to revive traumatized tissues. We present the first case of the catheter-induced mechanical block ("bump" phenomenon) that was unmasked with adenosine administration in the working myocardium of the superior vena cava. This result may be because, unlike before, we could determine the force of contact between the tip of the ablation catheter and the myocardial tissue. This case suggests the clinical usefulness of adenosine for unmasking bumped sites.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior
12.
J Arrhythm ; 37(4): 1052-1060, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34386132

RESUMO

BACKGROUND: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. METHODS: We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. RESULTS: Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. CONCLUSIONS: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.

13.
J Cardiovasc Electrophysiol ; 31(10): 2765-2769, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32757423

RESUMO

An 82-year-old woman received pacemaker implantation for sick sinus syndrome. Two days after the implantation, electrocardiography showed 2:1 atrial pacing failure, followed by a bradycardia-dependent increase in the atrial pacing threshold during a pacemaker examination. However, transient 1:1 atrial pacing capture recovered by adenosine triphosphate (ATP) administration, which was performed to evaluate the bradycardia-dependent pacing failure mechanism. We considered this phenomenon to be caused by Phase 4 depolarization and avoided replacing this atrial lead. Three weeks later, the atrial pacing threshold had improved. We report the potential role of Phase 4 depolarization in a bradycardia-dependent increase in pacing threshold by using ATP.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Adenosina , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Bradicardia/induzido quimicamente , Bradicardia/diagnóstico , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/terapia
14.
J Cardiovasc Electrophysiol ; 30(12): 2944-2949, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31588621

RESUMO

INTRODUCTION: One cause of cerebral infarction during cryoballoon ablation is the entry of air into a sheath due to the use of inappropriate catheters. It is known that the left atrial pressure of patients with obstructive sleep apnea syndrome can be negative. However, the effects of catheter selection and negative pressure changes in the sheath on air intrusion are not yet well understood. The aim of this study was to evaluate how catheter selection and negative pressure changes affect air intrusion and to perform countermeasures for air intrusion. METHODS AND RESULTS: This experiment used siphon principle to create negative pressure in the sheath. Noncryoablation catheters (not designed exclusively for cryoballoon ablation) and cryoballoon catheters were investigated. Catheters were inserted into the sheath and then removed. Thereafter, the amount of air in the sheath was measured. For catheters producing significantly larger amounts of air intrusion, the catheters were inserted via a long sheath in the sheath (sheath-in-sheath technique) and the same procedures were repeated. We found that the amount of air intrusion through most of the noncryoablation catheters was significantly larger than that through cryoablation catheters. An increase in the magnitude of negative pressure in the sheath resulted in a proportional increase in air intrusion, but the sheath-in-sheath technique significantly reduced air intrusion. CONCLUSION: The amount of air intrusion increased when using catheters with complicated tip shapes and thin outer diameters and when the magnitude of negative pressure in the sheath increased. The sheath-in-sheath technique may be an effective countermeasure.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Criocirurgia/instrumentação , Embolia/prevenção & controle , Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco/efeitos adversos , Criocirurgia/efeitos adversos , Embolia/etiologia , Embolia/fisiopatologia , Desenho de Equipamento , Humanos , Teste de Materiais , Fatores de Risco
17.
Circ J ; 80(11): 2302-2309, 2016 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-27680658

RESUMO

BACKGROUND: Whether pacing from the right ventricular (RV) septum improves prognosis is unclear. Furthermore, the clinical characteristics of patients who develop atrial fibrillation (AF) and cardiovascular events during long-term RV septal pacing have not been described.Methods and Results:We retrospectively evaluated the incidence of AF and cardiovascular events, including cardiac death, heart failure requiring hospitalization, or stroke, for a median of 4.0 years in 123 recipients of dual-chamber pacemakers implanted for atrioventricular block with preserved left ventricular function, who were free from AF before device implantation. AF developed in 30 patients (24%), and multivariable analysis suggested that the cumulative percentage of RV pacing was the only independent predictor of newly developed AF (hazard ratio: 1.19 for each 10% increment; 95% confidence interval: 1.04-1.41; P=0.01). Furthermore, older age, newly developed AF and a paced QRS duration ≥155 ms at pacemaker implantation were significant predictors of cardiovascular events. CONCLUSIONS: RV septum pacing may induce AF in up to one-quarter of patients paced for atrioventricular block, according to the frequency of pacing. More importantly, in such patients, AF induced by RV pacing and a paced QRS duration ≥155 ms at pacemaker implantation are significantly associated with poor prognosis. Therefore, we recommend pacing from sites producing a paced QRS duration <155 ms and avoiding unnecessary RV pacing. (Circ J 2016; 80: 2302-2309).


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Estimulação Cardíaca Artificial/métodos , Septos Cardíacos , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Feminino , Humanos , Masculino , Estudos Retrospectivos
18.
J Arrhythm ; 32(2): 89-94, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27092188

RESUMO

BACKGROUND: There are no criteria for selecting single- or dual-chamber implantable cardioverter defibrillators (ICDs) in patients without a pacing indication. Recent reports showed no benefit of the dual-chamber system despite its preference in the United States. As data on ICD selection and respective outcomes in Japanese patients are scarce, we investigated trends regarding single- and dual-chamber ICD usage in Japan. METHODS: Data from a total of 205 ICD recipients with structural heart disease (median age, 63 years) in two Japanese university hospitals were reviewed. Patients with bradycardia with a pacing indication and permanent atrial fibrillation at implantation were excluded. RESULTS: Single- and dual-chamber ICDs were implanted in 36 (18%) and 169 (82%) patients, respectively. Non-ischemic cardiomyopathy dominated both groups. Seventeen dual-chamber patients developed atrial pacing-dependency over 4.5 years, and it developed immediately after implantation in 14. Although preoperative testing showed no sign of bradycardia in these patients, their pacing rate was set higher than it was in patients who were pacing-independent (61 vs. 46 paces per min, p<0.01). Two single-chamber patients (5%) underwent atrial lead insertion. While inappropriate shock equally occurred in both groups (7 vs. 21 patients, single- vs. dual-chamber, P=0.285), device-related infection occurred only in dual-chamber patients (0 vs. 9 patients, P=0.155). No differences in death or heart failure hospitalization were observed between groups. CONCLUSIONS: Dual-chamber ICDs were four-fold more common in Japanese patients without a pacing indication. No benefit over single-chamber ICD was observed. Newly developed atrial pacing-dependency seemed to be limited and could have been overestimated due to higher pacing rate settings in dual-chamber patients.

19.
J Echocardiogr ; 13(1): 27-34, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25750577

RESUMO

BACKGROUND: Heart failure (HF) can be caused by left ventricular (LV) pump failure as well as by bradyarrhythmias. Hemodynamic differences between HF by LV pump failure and that by bradyarrhythmia have not been fully investigated. We hypothesized that HF by LV pump failure could be associated with both reduced cardiac output (CO) and increased LV filling pressure due to associated LV diastolic dysfunction, whereas HF by bradyarrhythmia could be associated with reduced CO but only modestly increased LV filling pressure due to the absence of LV diastolic dysfunction. METHODS: In 39 patients with HF by LV pump failure (LV ejection fraction <35%), 24 with HF by bradyarrhythmia, and 22 normal controls, LV volume, ejection fraction, stroke volume, left atrial volume, and early diastolic mitral valve flow to tissue annular velocity ratio (E/E') were measured by echocardiography. RESULTS: Compared to patients with HF by LV pump failure, those with HF by bradyarrhythmia had significantly lower heart rates, less LV dilatation, preserved LV ejection fraction, preserved stroke volume, similarly reduced cardiac index (1.8 ± 0.4 vs. 1.6 ± 0.4 L/min/m(2), n.s.), preserved LV diastolic function (E') (4.4 ± 2.1 vs. 7.1 ± 2.9 cm/s, p < 0.001), less dilated end-systolic LA volume, and preserved E/E' (24 ± 10 vs. 13 ± 7, p < 0.001). CONCLUSIONS: HF by LV pump failure is characterized by both significantly reduced CO and increased LV filling pressure, whereas HF by bradyarrhythmia is characterized by a similar reduction in CO but only modestly increased LV filling pressure.


Assuntos
Bradicardia/complicações , Débito Cardíaco , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Disfunção Ventricular Esquerda/complicações , Idoso , Idoso de 80 Anos ou mais , Bradicardia/diagnóstico por imagem , Diástole , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Pressão Ventricular
20.
Circ J ; 78(12): 2862-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25283686

RESUMO

BACKGROUND: Active fixation pacing leads with silicon cylinder tips have been used for their safety and flexibility. Measurement of baseline sensing/pacing characteristics before fixation of helix helps to identify the optimal pacing site, but we encountered difficulties in making these measurements despite multiple attempts with the model LPA 1200M lead. To identify the cause and overcome this complication, we compared 4 different retractable active fixation lead models, which enabled baseline sensing/pacing measurements before extension of helix. METHODS AND RESULTS: We immersed 4 different lead tips and rings in a 0.18% saline solution, and measured the lead impedance before and after flushing of air bubble visible inside the lead tip. Before evacuation of the air bubble, the impedance of the model LPA 1200M lead was >4,000 Ω in 8 out of 10 measurements, although that of the other leads was within the measurable range. After evacuation of the air bubble, the lead impedance returned to within the measurable range. There was no prominent change in the impedance of the metal cylinder tip lead. CONCLUSIONS: Air bubbles may interfere with the measurement of baseline sensing/pacing characteristics before active fixation of pacing leads with cylindrical silicon tips. In the case of high impedance beyond the measurable range before extension of helix, the measurement should be repeated after fixation into the myocardium before suspecting lead dysfunction.


Assuntos
Artefatos , Estimulação Cardíaca Artificial/métodos , Eletrodos Implantados , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Ar , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome do Nó Sinusal/fisiopatologia