Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Commun Biol ; 2: 437, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31799438

RESUMO

The sarcomere, the minimal mechanical unit of muscle, is composed of myosins, which self-assemble into thick filaments that interact with actin-based thin filaments in a highly-structured lattice. This complex imposes a geometric restriction on myosin in force generation. However, how single myosins generate force within the restriction remains elusive and conventional synthetic filaments do not recapitulate the symmetric bipolar filaments in sarcomeres. Here we engineered thick filaments using DNA origami that incorporate human muscle myosin to directly visualize the motion of the heads during force generation in a restricted space. We found that when the head diffuses, it weakly interacts with actin filaments and then strongly binds preferentially to the forward region as a Brownian ratchet. Upon strong binding, the two-step lever-arm swing dominantly halts at the first step and occasionally reverses direction. Our results illustrate the usefulness of our DNA origami-based assay system to dissect the mechanistic details of motor proteins.


Assuntos
Contração Muscular , Miosina Tipo II/fisiologia , Imagem Individual de Molécula/métodos , Proteínas do Citoesqueleto/metabolismo , Citoesqueleto/metabolismo , Humanos , Microscopia de Força Atômica , Modelos Biológicos , Ligação Proteica
2.
J Microbiol Methods ; 130: 106-111, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27558617

RESUMO

Single-cell transfection is a powerful technique for delivering chemicals, drugs, or probes into arbitrary, specific single cells. This technique is especially important when the analysis of molecular function and cellular behavior in individual microscopic organisms such as protists requires the precise identification of the target cell, as fluorescence labeling of bulk populations makes tracking of individual motile protists virtually impossible. Herein, we have modified current single-cell electroporation techniques for delivering fluorescent markers into single Euglena gracilis, a motile photosynthetic microalga. Single-cell electroporation introduced molecules into individual living E. gracilis cells after a negative pressure was applied through a syringe connected to the micropipette to the target cell. The new method achieves high transfection efficiency and viability after electroporation. With the new technique, we successfully introduced a variety of molecules such as GFP, Alexa Fluor 488, and exciton-controlled hybridization-sensitive fluorescent oligonucleotide (ECHO) RNA probes into individual motile E. gracilis cells. We demonstrate imaging of endogenous mRNA in living E. gracilis without interfering with their physiological functions, such as swimming or division, over an extended period of time. Thus the modified single-cell electroporation technique is suitable for delivering versatile functional molecules into individual motile protists.


Assuntos
Eletroporação/métodos , Euglena gracilis/citologia , Euglena gracilis/genética , Análise de Célula Única/métodos , Transfecção/métodos , Sequência de Bases , Sobrevivência Celular , Euglena gracilis/fisiologia , Hibridização In Situ , Modelos Biológicos , Hibridização de Ácido Nucleico , Oligonucleotídeos , Sondas RNA , RNA Mensageiro/genética , Fatores de Tempo
3.
Proc Natl Acad Sci U S A ; 109(14): 5294-8, 2012 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-22431610

RESUMO

Single molecule fluorescence polarization techniques have been used for three-dimensional (3D) orientation measurements to observe the dynamic properties of single molecules. However, only few techniques can simultaneously measure 3D orientation and position. Furthermore, these techniques often require complex equipment and cumbersome analysis. We have developed a microscopy system and synthesized highly fluorescent, rod-like shaped quantum dots (Q rods), which have linear polarizations, to simultaneously measure the position and 3D orientation of a single fluorescent probe. The optics splits the fluorescence from the probe into four different spots depending on the polarization angle and projects them onto a CCD camera. These spots are used to determine the 2D position and 3D orientation. Q rod orientations could be determined with better than 10° accuracy at 33 ms time resolution. We applied our microscopy and Q rods to simultaneously measure myosin V movement along an actin filament and rotation around its own axis, finding that myosin V rotates 90° for each step. From this result, we suggest that in the two-headed bound state, myosin V necks are perpendicular to one another, while in the one-headed bound state the detached trailing myosin V head is biased forward in part by rotating its lever arm about its own axis. This microscopy system should be applicable to a wide range of dynamic biological processes that depend on single molecule orientation dynamics.


Assuntos
Microscopia de Fluorescência/métodos , Miosina Tipo V/metabolismo , Pontos Quânticos , Actinas/metabolismo , Polarização de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA