Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Neurochir (Wien) ; 154(5): 773-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22327325

RESUMO

BACKGROUND: The purpose of this study was to evaluate and analyze overall postoperative results from microvascular decompression (MVD) by combining the cure rate of symptoms with the complication rate. A new scoring system for obtaining objective surgical results from MVD for trigeminal neuralgia (TN) and hemifacial spasm (HFS) is proposed to document treatment results using consistent criteria in a standardized manner. METHOD: Surgical results combining complications , if any, were obtained from a questionnaire sent to patients who had undergone surgery for TN or HFS in recent years and had been followed-up for more than 1 year after surgery (TN patients, n = 54; HFS patients, n = 81) When surgical outcome is complete resolution of symptoms, the efficacy of surgery (E) is designated E-0, but when moderate symptoms are still persist postoperatively, the score is designated E-2. When no complications are seen after surgery, the complication score (C) is C-0, while the score is C-2 if troublesome complications remain. In addition, total evaluation of the results (T) is judged by combining the E and C scores. For example, when E is 0, and C is C-2, the total evaluation is scored as T-2, which is diagnosed as fair. FINDINGS: The response rate of the questionnaire was 80.7% (109/135). Overall surgical data were evaluated and analyzed using our new scoring system. Analysis of the collected data revealed an outcome of T-0 was 70% (35/50 patients) and T-1 was 24% (12/50) and T-2 was 6% (3/50) in TN, whereas in HFS, T-0 was 61% (36/59) and T-1 was 27.1% (16/59) and T-2 was 6.8% (4/59) and T-3 was 5.1% (3/59). CONCLUSION: The total results of MVD should be evaluated and analyzed by combining the cure rate of symptoms together with the complication rate. This new scoring system could allow much more objective analysis of the results of following MVD. Adopting this scoring system to objectively judge treatment results for TN and HFS, individual surgeons can compare their own overall surgical results with those of other institutes. Comparative results of MVD can also be provided to patients considering therapy to allow informed decision-making on the basis of good quality evidence.


Assuntos
Espasmo Hemifacial/cirurgia , Cirurgia de Descompressão Microvascular/métodos , Neuralgia do Trigêmeo/cirurgia , Seguimentos , Humanos , Complicações Pós-Operatórias , Inquéritos e Questionários , Resultado do Tratamento
2.
Artif Organs ; 32(6): 473-83, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18422798

RESUMO

We have developed novel watertight and bioabsorbable synthetic dural substitutes. The substitutes were designed such that they had a three-layered structure, and each layer comprised a bioabsorbable copolymer prepared from L-lactide, glycolide, and epsilon-caprolactone. Various copolymers were synthesized, and appropriate compositions were selected for preparing the substitutes based on the results of leakage tests. Experimental substitutes that prevented the leakage of saline through the suture lines between the substitutes and dura mater were prepared. An in vitro study was performed in which the substitutes were sutured to porcine dura mater, and the amount of saline leakage was measured. It was demonstrated that leakage through the suture line could be completely suppressed by using the substitutes we developed along with favorable suturing techniques.


Assuntos
Implantes Absorvíveis , Dura-Máter/fisiologia , Poliésteres/química , Animais , Materiais Biocompatíveis/química , Elasticidade , Porosidade , Sus scrofa , Técnicas de Sutura , Suturas , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA