Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 54(5): 1300-4, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16217778

RESUMO

Sentinel lymph node biopsy (SLNB) is an important technique for detecting axillary lymph node metastasis in breast carcinoma patients. However, false-negative results are a problem. Equivalent cross-relaxation rate (ECR) imaging (ECRI) is a measurement method that can be used to quantitatively evaluate a change in the structural organization of lymph nodes by magnetic resonance imaging (MRI). We performed axillary ECRI in an attempt to decrease the false-negative results of SLNB. Regions without metastases showed a higher ECR value. On the other hand, regions with metastases showed a lower ECR value. The ECR images were compared with macroscopic histology images in which the presence or absence of axillary lymph node metastasis could be evaluated. ECRI is a potentially useful method for evaluating the efficacy of SLNB.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal/patologia , Carcinoma Ductal/secundário , Interpretação de Imagem Assistida por Computador/métodos , Linfonodos/patologia , Imageamento por Ressonância Magnética/métodos , Biópsia de Linfonodo Sentinela/métodos , Adulto , Idoso , Algoritmos , Reações Falso-Negativas , Feminino , Humanos , Aumento da Imagem/métodos , Metástase Linfática , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Magn Reson Imaging ; 20(3): 285-93, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12117611

RESUMO

The values of equivalent cross-relaxation rate (ECR) correlated well with [i] water conditions in various copolymer gels and [ii] nature of malignant cells with regard to nuclear dysplasia and mitotic potential in breast carcinomas. The synthetic copolymer gels composed of any two or three monomers among 2-hydroxyethyl methacrylate (HEMA), glycidyl methacrylate (GMA), N-vinyl-2-pyrrolidinone (N-VP), methyl methacrylate (MMA) and benzyl methacrylate (BMA). The ECR measurement was performed by using an off-resonance saturation pulse under conventional field-echo imaging at frequency within +/- 75 ppm apart from the water resonance frequency. The ECR values were readily to determine and non-time consuming parameter for cross relaxation rate. The ECR values at the frequency offset by 7-ppm (ECR-7) were divided the sample gels two classes, which must correspond to hydrophilic or hydrophobic ones. The sensitivity in the gels was nearly equivalent to the cross-relaxation rate itself. In the breast carcinomas, the ECR-7 correlates with the nature of malignant cells with regard to nuclear dysplasia and mitotic potential. The ECR-7 is better or more accurate than the STR-7 because the SDNRs between carcinoma and glandular tissue increased by approximately 50% on the ECR-7 compared with the STR-7. Thus the ECR values could be a new parameter for malignancy and cell proliferative activity of the breast carcinomas with non-invasive modalities by magnetic resonance imaging.


Assuntos
Neoplasias da Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Géis/química , Imageamento por Ressonância Magnética , Metacrilatos/química , Adulto , Idoso , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Compostos de Epóxi/química , Feminino , Humanos , Metacrilatos/síntese química , Metilmetacrilato/química , Pessoa de Meia-Idade , Pirrolidinonas/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...