Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
J Clin Med ; 13(11)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38893007

RESUMO

Background/Objectives: A highly porous titanium cup with a three-dimensional metal interface was recently introduced to improve biological fixation and survival. However, radiography has revealed concerns regarding these cups, despite their excellent short- and mid-term clinical outcomes. This study compared the clinical and radiographic results of a highly porous titanium cup with those of a hydroxyapatite-coated porous titanium cup after primary total hip arthroplasty (THA). Methods: Fifty-one primary THAs were investigated. A highly porous titanium cup was used in 17 hips, and a hydroxyapatite-coated porous titanium cup was used in 34 hips. No significant differences in preoperative patient demographic characteristics were observed between the two groups. The 2-year postoperative clinical and radiographic results were compared. Results: Radiolucent lines were observed in 13 (76%) of 17 hips with highly porous titanium cups and in none (0%) of 34 hips with hydroxyapatite-coated porous titanium cups (p < 0.001). In the highly porous titanium cup group, radiolucent lines were observed in five hips (29%) in one zone, two hips (11%) in two zones, and six hips (35%) in three zones. No cup loosening was observed in either group. Conclusions: Radiolucent lines were significantly more frequent in highly porous titanium cups. This study suggests that, compared to the three-dimensional structure of porous titanium, the hydroxyapatite coating of porous titanium had a greater influence on bone ingrowth in the short term. The meaning of these findings in the long-term is unclear yet.

2.
Bone Joint J ; 106-B(6): 548-554, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821498

RESUMO

Aims: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Materiais Revestidos Biocompatíveis , Osso Cortical , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Fêmur/cirurgia , Osso Cortical/cirurgia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38753013

RESUMO

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.

4.
Eur J Orthop Surg Traumatol ; 34(4): 2041-2047, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38517525

RESUMO

PURPOSE: This study aimed to compare bone mineral density (BMD) changes around the femoral component after total hip arthroplasty (THA) in a fully hydroxyapatite-coated stem (CORAIL) and in a tapered-wedge stem (Taperloc complete) and identify predictors of BMD changes. METHODS: This retrospective study compared 43 hips in the CORAIL group and 40 hips in the Taperloc group. The relative changes in BMD at 2 years after THA measured using dual-energy X-ray absorptiometry and the three-dimensional quantified contact states of the stem with the femoral cortical bone were assessed. Predictors of the relative change in the BMD around the proximal part of the stem were examined using multiple regression analysis. RESULTS: The decrease in BMD in Gruen zone 7 was significantly less in the CORAIL group than in the Taperloc group (P = 0.02). In the CORAIL group, the contact area in any zone was not a significant predictor of the relative changes in BMD. The contact area between the Taperloc stem and the femoral cortical bone in zones 2 and 6 was a positive predictor of the relative changes in BMD in zones 1 (P = 0.02 and P = 0.04, respectively) and 2 (P = 0.008 and P = 0.004, respectively). CONCLUSION: The CORAIL stem suppressed the postoperative BMD loss around the stem, irrespective of the contact state. The Taperloc complete stem required contact with the proximal femoral metaphysis to suppress the postoperative BMD loss around the stem.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Remodelação Óssea , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Remodelação Óssea/fisiologia , Pessoa de Meia-Idade , Idoso , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Materiais Revestidos Biocompatíveis
5.
BMJ Open ; 14(3): e082342, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553078

RESUMO

OBJECTIVES: This study documents the time elapsed from the diagnosis of osteonecrosis of the femoral head (ONFH) to surgery, exploring the factors that influence ONFH severity. DESIGN: Retrospective observational study of a nationwide database. SETTING: The Kaplan-Meier method with log-rank tests was applied to examine the period from definitive diagnosis of ONFH to surgery using any surgery as the end point. For bilateral cases, the date of the first surgery was the endpoint. PARTICIPANTS: This study included 2074 ONFH cases registered in 34 university hospitals and highly specialised hospitals of the multicentre sentinel monitoring system of the Japanese Investigation Committee between 1997 and 2018. MAIN OUTCOME MEASURE: The primary outcome was the time from diagnosis to surgery. The secondary outcome was the proportion of subjects remaining without surgery at 3, 6 and 9 months, and at 1, 2 and 5 years after diagnosis. RESULTS: The median time to surgery was 9 months (IQR 4-22 months) after diagnosis of ONFH. The time to surgery was significantly shorter in the alcohol alone group and the combined corticosteroid and alcohol group than in the corticosteroid alone group (p=0.018 and p<0.001, respectively), in early stage ONFH with no or mild joint destruction (stages II and III, p<0.001), and with joint preserving surgery (p<0.001). The proportion without surgery was 75.8% at 3 months, 59.6% at 6 months, 48.2% at 9 months, 40.5% at 1 year, 22.2% at 2 years and 8.3% at 5 years. CONCLUSION: ONFH has been considered to be an intractable disease that often requires surgical treatment, but the fact that surgery was performed in more than half of the patients within 9 months from diagnosis suggests severe disease with a significant clinical impact. TRIAL REGISTRATION NUMBER: Chiba University ID1049.


Assuntos
Necrose da Cabeça do Fêmur , Humanos , Japão/epidemiologia , Necrose da Cabeça do Fêmur/diagnóstico , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Estudos Retrospectivos , Corticosteroides
6.
J Arthroplasty ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38360279

RESUMO

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.

7.
Hip Int ; 34(1): 57-65, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37293785

RESUMO

AIM: This study aimed to assess the relationship between the three-dimensional (3D) alignment of short tapered-wedge cementless stems and bone mineral density (BMD) changes in patients followed up for 5 years after total hip arthroplasty (THA). METHODS: We retrospectively analysed the hips of 52 patients who underwent THA using short tapered-wedge cementless stems at our institution from 2013 to 2016 with complete 5-year follow-up data. We evaluated the relationship between stem alignment, measured using a 3D-templating software, and BMD changes in the 7 Gruen zones. RESULTS: After 1 year, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD in zones 3 and 4 were noted. After 5 years, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD zones 2, 3, and 4 were observed. With increased amounts of varus/flexion stem alignment, the amount of BMD loss decreased. There was no correlation between anteverted stem insertion and changes in BMD levels. CONCLUSIONS: Our data showed that stem alignment affects BMD based on 5-year follow-up data after surgery. Careful observation is necessary, especially when using short tapered-wedge cementless stems, as stem alignment may affect changes in BMD levels more than 5 years after surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Densidade Óssea , Estudos Retrospectivos , Desenho de Prótese , Fêmur/cirurgia
8.
Prog Rehabil Med ; 8: 20230027, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37705509

RESUMO

Objectives: Patients with severe coronavirus disease 2019 (COVID-19) who develop pneumonia face the risk of ventilatory muscle disuse in the acute phase, which can result in persistent respiratory impairments in the subacute phase. Although rehabilitation during the acute phase is considered effective, there are limited reports on this topic. Therefore, this study aimed to investigate the effectiveness of acute-phase rehabilitation in patients with severe COVID-19. Methods: The study included 57 patients (45 men and 12 women; mean age: 63.2±12.1 years) admitted between April and June 2021, all of whom required intubation for respiratory management. Among them, 34 patients underwent acute-phase rehabilitation interventions based on the early goal-directed mobilization protocol. The primary objectives were to assess the occurrence of medical accidents related to acute-phase rehabilitation and evaluate their impact on survival and mobility upon hospital discharge. Statistical techniques and machine learning algorithms were employed for data analysis. Results: Remarkably, no medical accidents occurred during the acute-phase rehabilitation among the patients. Furthermore, our findings indicated that acute-phase rehabilitation did not influence survival outcomes. However, it did have a positive impact on the mobility of patients upon hospital discharge. Conclusions: Acute-phase rehabilitation can be safely administered to patients with severe COVID-19 by following an early goal-directed mobilization protocol. This approach may also contribute to improved activities of daily living after discharge.

9.
Arch Orthop Trauma Surg ; 143(11): 6781-6790, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37418005

RESUMO

INTRODUCTION: It is preferable to reduce postoperative excessive rotational mismatch between the femur and tibia that causes poor clinical results following total knee arthroplasty (TKA). The aim of this study is to compare postoperative rotational mismatches and clinical outcomes with mobile- and fixed-bearing prostheses. MATERIALS AND METHODS: This study classified 190 TKAs into two groups equally by propensity score matching: mobile-bearing group (n = 95) and fixed-bearing group (n = 95). Computed tomography images of the whole leg were taken at 2 weeks postoperatively. The component alignments, rotational mismatches between the femur and tibia, and rotations among components were measured three-dimensionally. The knee range of motion, New Knee Society Score (KSS) subjective sores, and Forgotten Joint Score (FJS-12) were assessed at the final follow-up. RESULTS: Rotational mismatch between the femur and tibia was significantly less in the mobile- (- 0.8° ± 7.3°) than in the fixed-bearing (3.3° ± 8.5°, p < 0.001) group. New KSS functional activity score was significantly poorer in patients with excessive rotational mismatch (61.3 ± 21.4) than in those without it (49.5 ± 20.6, p = 0.02). Comparing mobile-bearing prosthesis, the use of fixed-bearing prosthesis was a risk factor for postoperative excessive rotational mismatch (odds ratio: 2.32, p = 0.03). CONCLUSION: When compared to a fixed-bearing prosthesis, TKA using a mobile-bearing prosthesis could suppress the postoperative rotational mismatch between the femur and tibia that causes poor subjective functional activity score. However, since this study was conducted for PS-TKA, the results might not be applicable to other models.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Medidas de Resultados Relatados pelo Paciente
10.
Arch Orthop Trauma Surg ; 143(10): 6345-6351, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37103606

RESUMO

INTRODUCTION: Previous reports using cadaveric knees and musculoskeletal computer simulation have shown that kinematically aligned (KA) total knee arthroplasty (TKA) provides more natural and physiological tibiofemoral kinematic patterns than mechanically aligned (MA) TKA. These reports suggested that the modification of joint line obliquity improve the knee kinematics. This study aimed to determine whether joint line obliquity change the intraoperative tibiofemoral kinematics in TKA candidates with knee osteoarthritis. METHODS: Thirty consecutive knees with varus osteoarthritis that underwent TKA using a navigation system were evaluated. Two types of trial components were prepared: (1) MA TKA model: component trial in which articulating surface was parallel to the bone cut surface (2) KA TKA model: the femoral component trial, which mimicked the KA TKA method of Dossett et al. was designed 3° valgus and 3° internal rotation to the femoral bone cut surface, and the tibial component trial was designed 3° varus to the tibial bone cut surface. These two trials were set on the same knees during the operation, and the tibiofemoral rotational kinematics and varus-valgus laxity were measured from 0° to 120° of knee flexion using a navigation system. RESULTS: The joint gap was 20 ± 2 mm and 3° ± 1° varus in extension and 20 ± 2 mm and 3° ± 1°varus in flexion. The differences in femoral component rotation between KA TKA and MA TKA were not statistically significant for any knee flexion angle. The differences in varus-valgus laxity between KA TKA and MA TKA were also not statistically significant for any knee flexion angle. CONCLUSION: Although the degree of joint line obliquity varies widely in various KA TKA methods, this study, which mimicked the method of Dossett et al. showed that the modification of joint line obliquity did not change the tibiofemoral kinematics and stability of the knee joint in TKA candidates with knee osteoarthritis.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Amplitude de Movimento Articular/fisiologia
11.
SICOT J ; 9: 2, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36648275

RESUMO

PURPOSE: The relationship between spinopelvic mobility and dislocation in total hip arthroplasty (THA) has recently attracted attention. This study aimed to investigate the differences in sacral slope (SS) between two types of upright seated positions and to determine which seated position was appropriate for assessing spinopelvic mobility (change in SS from standing to sitting) before THA. MATERIALS AND METHODS: This prospective cohort study included 75 hips from 75 patients who had undergone primary THA. Each patient underwent preoperative lateral spinopelvic radiography in standing (st) and two seated positions: relaxed (rs) and straight (ss). The change in SS between each position (Δ) was measured. RESULTS: Differences in all spinopelvic sagittal alignment parameters between the two seated positions were statistically significant (p < 0.001). The range, median, and mean values of ΔSSss-rs were -2.0° to 26.5°, 6.8°, and 8.3°, respectively. ΔSSss-rs was significantly correlated with SS, LLA, and PFA in the relaxed seated position (r = -0.52, -0.39, and 0.37; p < 0.001, p < 0.001, and p = 0.001, respectively), but was not correlated to these parameters in the straight seated position. Of the 52 patients with normal spinopelvic mobility in the relaxed seated position (ΔSSst-rs > 10°), 24 (46%) patients were misrepresented as having a stiff spine in the straight seated position (ΔSSst-ss < 10°). CONCLUSION: The change in SS from the straight to the relaxed seated position widely varied in patients before THA. The spinopelvic radiograph in the relaxed seated position is appropriate when evaluating spinopelvic mobility for preoperative planning.

12.
Hip Int ; 33(2): 231-240, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34392737

RESUMO

BACKGROUND: The combined anteversion theory to prevent impingement in total hip arthroplasty (THA) has been proposed. However, because stem-anteversion is influenced by the native femoral anteversion and the stem flexion/extension angle, it is often difficult to adjust stem anteversion during surgery. Therefore, the stem-first (combined anteversion) technique may be useful to adjust and achieve appropriate cup anteversion during surgery with respect to the implanted stem anteversion angle. However, the technique may adversely affect cup or stem angle accuracy and result in intra-operative bleeding, post-operative adverse events, and prolonged operative time. It is inconclusive whether either the stem-first or cup-first technique is safe or accurate. Therefore, this study assessed the accuracy and safety of stem-first THA compared to those of cup-first THA. MATERIALS AND METHODS: This prospective randomised controlled trial analysed 114 patients who were randomly divided into 2 groups (stem-first group: n = 57, cup-first group (control group): n = 57). Primary outcomes included cup and stem angle, the discrepancies from the targeted angle and combined anteversion (evaluated via CT at 3 months postoperatively). Secondary outcomes included intraoperative blood loss, operative time, WOMAC, and adverse events. RESULTS: There were no significant differences in age, gender, BMI or in the primary and secondary outcomes between the 2 groups. CONCLUSIONS: Performing stem-first in THA did not adversely affect cup and stem angle accuracy, or result in intraoperative bleeding, prolongation of operative time, or postoperative adverse events. Thus, performing stem-first may be advantageous for achieving combined anteversion theory. TRIAL REGISTRATION: University Hospital Medical Information Network (UMIN) registration number UMIN000025189.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Prospectivos , Fêmur/cirurgia , Duração da Cirurgia
13.
Arch Orthop Trauma Surg ; 143(7): 4465-4472, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36261646

RESUMO

INTRODUCTION: It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS: Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS: The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (ß = 0.41, p < 0.01) and stem coronal alignment (ß = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION: The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Durapatita , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Desenho de Prótese
14.
Arch Orthop Trauma Surg ; 143(7): 4473-4480, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36322198

RESUMO

INTRODUCTION: No studies have compared the accuracy of acetabular cup placement in total hip arthroplasty (THA) in the supine and lateral decubitus positions using the same portable navigation system. Thus, this study aimed to compare the accuracy of acetabular cup placement using a new accelerometer-based portable navigation system combined with an infrared stereo camera and inertial measurement unit between the supine and lateral decubitus positions. MATERIALS AND METHODS: This retrospective study compared 45 THAs performed in the supine position (supine group) and 44 THAs performed in the lateral decubitus position (lateral group) using the same portable navigation system. The primary outcome was the absolute errors of cup placement angles, defined as the absolute values of the differences between cup radiographic inclination and anteversion angles displayed on the navigation system and those measured on postoperative computed tomography images. RESULTS: No significant difference in the median absolute error of the cup inclination angle (supine group 1.7° [interquartile range 0.8°-3.1°] vs. lateral group 2.1° [interquartile range 1.0°-3.7°]; p = 0.07) was found between the two groups. Similarly, no significant difference in the median absolute error of the anteversion angle (supine group 1.9° [interquartile range 0.8°-3.4°] vs. lateral group 2.1° [interquartile range 0.9°-3.1°]; p = 0.42) was found. CONCLUSION: This new accelerometer-based portable navigation system may provide high accuracy of the cup placement in THA in the lateral decubitus and supine positions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Decúbito Dorsal , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acelerometria
15.
Biochem Biophys Res Commun ; 597: 58-63, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35124460

RESUMO

Vitamin D has been shown to reduce symptoms in patients with osteoarthritis (OA). In a previous study, local administration of eldecalcitol, an active vitamin D3 analog, reduced degenerative changes in articular cartilage in the early phase of experimental OA. However, the target of vitamin D in OA remains unknown. Here, we investigated the effect of eldecalcitol treatment on chondrocytes, which were divided into superficial zone chondrocytes (SZC), deep zone chondrocytes (DZC), and differentiated chondrocytes. SZC and DZC were cultured in monolayer and 3D pellet cultures treated with eldecalcitol. The gene expressions of articular cartilage and chondrocyte differentiation markers were evaluated. Histological analysis of SZC and DZC 3D pellet cultures was performed. The results showed that the articular cartilage markers ETS-related gene (Erg) and lubricin/proteoglycan 4 (PRG4) were significantly increased in SZC, but not in DZC, in the monolayer culture treated with eldecalcitol. The chondrocyte differentiation markers type X collagen and alkaline phosphatase (ALP) were significantly decreased in the DZC pellet culture treated with eldecalcitol. Immunochemical analysis also showed that Erg and lubricin/PRG4 expressions were elevated in the SZC pellet culture treated with eldecalcitol, while type X collagen and ALP expressions were decreased in the DZC pellet culture treated with eldecalcitol. In conclusion, this study showed that eldecalcitol upregulated articular cartilage markers in SZC and suppressed differentiation markers in DZC. Such regulation of chondrocytes by eldecalcitol could be potentially effective against OA progression.

16.
Mol Clin Oncol ; 16(2): 26, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34984100

RESUMO

Clear cell chondrosarcoma (CCCS) is a rare, low-grade, malignant chondrogenic bone tumour. This tumour commonly affects the epiphysis of long bones, particularly in the proximal femur. The present study reported on the case of a 58-year-old male with right hip pain of five months duration. Plain radiography, magnetic resonance imaging and computed tomography scan revealed the characteristic appearance of chondroid mineralisation in the right femoral head, suggesting typical CCCS. Although biopsy is the gold standard for definite diagnosis prior to treatment, wide resection with removal of the biopsy tract is thought to negatively affect the surgical margin and postoperative hip function. Therefore, en bloc resection without any biopsy and a hip hemiarthroplasty were performed. The pathological diagnosis was CCCS and an adequate surgical margin was obtained. No local recurrence or distant metastases were detected and postoperative function was excellent at the final follow-up. The femoral head is a typical location of CCCS. Wide resection with adequate margins is the main treatment strategy for CCCS and when radiological features are typical, en bloc resection without a biopsy is an acceptable treatment option to improve patient outcomes.

17.
Hum Mol Genet ; 31(7): 1082-1095, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34850884

RESUMO

Osteonecrosis of the femoral head (ONFH) involves necrosis of bone and bone marrow of the femoral head caused by ischemia with unknown etiology. Previous genetic studies on ONFH failed to produce consistent results, presumably because ONFH has various causes with different genetic backgrounds and the underlying diseases confounded the associations. Steroid-associated ONFH (S-ONFH) accounts for one-half of all ONFH, and systemic lupus erythematosus (SLE) is a representative disease underlying S-ONFH. We performed a genome-wide association study (GWAS) to identify genetic risk factors for S-ONFH in patients with SLE. We conducted a two-staged GWAS on 636 SLE patients with S-ONFH and 95 588 non-SLE controls. Among the novel loci identified, we determined S-ONFH-specific loci by comparing allele frequencies between SLE patients without S-ONFH and non-SLE controls. We also used Korean datasets comprising 148 S-ONFH cases and 37 015 controls to assess overall significance. We evaluated the functional annotations of significant variants by in silico analyses. The Japanese GWAS identified 4 significant loci together with 12 known SLE susceptibility loci. The four significant variants showed comparable effect sizes on S-ONFH compared with SLE controls and non-SLE controls. Three of the four loci, MIR4293/MIR1265 [odds ratio (OR) = 1.99, P-value = 1.1 × 10-9)], TRIM49/NAALAD2 (OR = 1.65, P-value = 4.8 × 10-8) and MYO16 (OR = 3.91, P-value = 4.9 × 10-10), showed significant associations in the meta-analysis with Korean datasets. Bioinformatics analyses identified MIR4293, NAALAD2 and MYO16 as candidate causal genes. MIR4293 regulates a PPARG-related adipogenesis pathway relevant to S-ONFH. We identified three novel susceptibility loci for S-ONFH in SLE.


Assuntos
Necrose da Cabeça do Fêmur , Lúpus Eritematoso Sistêmico , Esteroides , Carboxipeptidases/genética , Proteínas de Transporte/genética , Cabeça do Fêmur , Necrose da Cabeça do Fêmur/induzido quimicamente , Necrose da Cabeça do Fêmur/complicações , Necrose da Cabeça do Fêmur/genética , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Humanos , Lúpus Eritematoso Sistêmico/genética , MicroRNAs/genética , Cadeias Pesadas de Miosina/genética , Polimorfismo de Nucleotídeo Único , Esteroides/efeitos adversos
18.
Eur J Orthop Surg Traumatol ; 32(3): 551-557, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34043059

RESUMO

PURPOSE: Medial pivot total knee arthroplasty (MP-TKA) is characterized by the ball-in-socket medial tibiofemoral articulation to achieve low wear and to reproduce the medial pivot motion similar to that in the normal knee, and there have been reports of favorable long-term postsurgical outcomes. However, most of these cases concerned varus knees, and the outcomes of MP-TKA in valgus knees are unknown. The objective of this study was to investigate the postoperative outcomes in end-stage valgus knee OA patients who underwent MP-TKA, through comparisons with those who underwent TKA using the same prosthesis for varus deformity. METHODS: This retrospective, single-center, cohort study analyzed 171 knees of 121 patients who were divided into two groups (valgus knee group: 15 knees (13 patients), varus knee group: 156 knees (109 patients)). Primary outcome measures included the knee joint range of motion (evaluated preoperatively and at every year postoperatively). Secondary outcomes included operative time, laboratory data, estimated blood loss, clinical outcome measures and adverse events. RESULTS: There were no significant differences in age, sex and body mass index, as well as in the postoperative primary and secondary outcome measures between the two groups. CONCLUSION: The use of MP-TKA featuring ball-in-socket medial tibiofemoral articulation in patients with valgus knee OA showed equally favorable clinical outcomes more than 2 years after surgery, compared to patients with varus knees who received MP-TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
19.
Knee ; 34: 55-61, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34875497

RESUMO

BACKGROUND: Use of a porous tantalum tibial component for total knee arthroplasty (TKA) was reported to have beneficial effects on periprosthetic bone mineral density (BMD). In some cases, hexagonal peg is placed close to or in contact with the tibial cortex, which may result in stress-shielding around the peg. However, no studies have analyzed the relationship between peg position and BMD. The aim of this study was to compare the peg position and BMD around the peg in a porous tantalum tibial component after TKA. METHODS: Twenty-seven patients (27 knees) who underwent primary TKA with a cementless porous tantalum tibial component were investigated. BMD was measured by dual-energy X-ray absorptiometry for 2 years after the operation. The distance between the peg and the tibial cortex (peg distance) was measured on the medial and lateral sides. RESULTS: BMD was decreased in the medial region after the operation (p < 0.01). Relative change in BMD was lower in the medial region than in the central and lateral regions (p < 0.01). Multiple regression analysis showed that medial peg distance was negatively correlated with relative change of BMD in the medial part of the tibia (p = 0.04, R = 0.402). CONCLUSIONS: The medial peg position affected the postoperative relative change of BMD in the medial part of the tibia, but did not affect the longevity of the implant. As the tibial medial peg became closer to the medial tibial cortex, the BMD loss became larger in the medial part of the tibia at 2 years postoperatively.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Absorciometria de Fóton , Densidade Óssea , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Porosidade , Tantálio , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
20.
J Clin Med ; 12(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36614940

RESUMO

Currently, various minimally invasive surgical techniques are applied for total hip arthroplasty (THA). There are few studies comparing the early postoperative clinical outcomes of minimally invasive THA between anterolateral and posterolateral approaches. In this retrospective study, 62 patients underwent minimally invasive THA via either the anterolateral approach with an intermuscular exposure using the modified Watson-Jones approach (MIS-AL, 34 hips) or mini-incision THA with a posterolateral approach (MIS-PL, 28 hips). We analyzed intraoperative data, postoperative hematological data, postoperative radiographic findings, and the postoperative recovery of muscle strength. The mean surgical time was significantly longer in the MIS-PL than in the MIS-AL group. The mean postoperative serum C-reactive protein level was significantly higher in the MIS-PL group than in the MIS-AL group only on postoperative day 3. There were no significant between-group differences in the postoperative recovery rate of muscle strength during hip abduction. The recovery rate of muscle strength during hip extension was better in the MIS-AL group than in the MIS-PL group only on postoperative day 3. In conclusion, we found no obvious advantage in early postoperative recovery between the MIS-AL and MIS-PL approaches. Therefore, the benefit of rapid postoperative recovery was comparable between the MIS-AL and MIS-PL approaches.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...