Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone Joint J ; 106-B(6): 548-554, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821498

RESUMO

Aims: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Materiais Revestidos Biocompatíveis , Osso Cortical , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Fêmur/cirurgia , Osso Cortical/cirurgia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38753013

RESUMO

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.

3.
Eur J Orthop Surg Traumatol ; 34(4): 2041-2047, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38517525

RESUMO

PURPOSE: This study aimed to compare bone mineral density (BMD) changes around the femoral component after total hip arthroplasty (THA) in a fully hydroxyapatite-coated stem (CORAIL) and in a tapered-wedge stem (Taperloc complete) and identify predictors of BMD changes. METHODS: This retrospective study compared 43 hips in the CORAIL group and 40 hips in the Taperloc group. The relative changes in BMD at 2 years after THA measured using dual-energy X-ray absorptiometry and the three-dimensional quantified contact states of the stem with the femoral cortical bone were assessed. Predictors of the relative change in the BMD around the proximal part of the stem were examined using multiple regression analysis. RESULTS: The decrease in BMD in Gruen zone 7 was significantly less in the CORAIL group than in the Taperloc group (P = 0.02). In the CORAIL group, the contact area in any zone was not a significant predictor of the relative changes in BMD. The contact area between the Taperloc stem and the femoral cortical bone in zones 2 and 6 was a positive predictor of the relative changes in BMD in zones 1 (P = 0.02 and P = 0.04, respectively) and 2 (P = 0.008 and P = 0.004, respectively). CONCLUSION: The CORAIL stem suppressed the postoperative BMD loss around the stem, irrespective of the contact state. The Taperloc complete stem required contact with the proximal femoral metaphysis to suppress the postoperative BMD loss around the stem.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Remodelação Óssea , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Remodelação Óssea/fisiologia , Pessoa de Meia-Idade , Idoso , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Materiais Revestidos Biocompatíveis
4.
Arch Orthop Trauma Surg ; 143(10): 6345-6351, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37103606

RESUMO

INTRODUCTION: Previous reports using cadaveric knees and musculoskeletal computer simulation have shown that kinematically aligned (KA) total knee arthroplasty (TKA) provides more natural and physiological tibiofemoral kinematic patterns than mechanically aligned (MA) TKA. These reports suggested that the modification of joint line obliquity improve the knee kinematics. This study aimed to determine whether joint line obliquity change the intraoperative tibiofemoral kinematics in TKA candidates with knee osteoarthritis. METHODS: Thirty consecutive knees with varus osteoarthritis that underwent TKA using a navigation system were evaluated. Two types of trial components were prepared: (1) MA TKA model: component trial in which articulating surface was parallel to the bone cut surface (2) KA TKA model: the femoral component trial, which mimicked the KA TKA method of Dossett et al. was designed 3° valgus and 3° internal rotation to the femoral bone cut surface, and the tibial component trial was designed 3° varus to the tibial bone cut surface. These two trials were set on the same knees during the operation, and the tibiofemoral rotational kinematics and varus-valgus laxity were measured from 0° to 120° of knee flexion using a navigation system. RESULTS: The joint gap was 20 ± 2 mm and 3° ± 1° varus in extension and 20 ± 2 mm and 3° ± 1°varus in flexion. The differences in femoral component rotation between KA TKA and MA TKA were not statistically significant for any knee flexion angle. The differences in varus-valgus laxity between KA TKA and MA TKA were also not statistically significant for any knee flexion angle. CONCLUSION: Although the degree of joint line obliquity varies widely in various KA TKA methods, this study, which mimicked the method of Dossett et al. showed that the modification of joint line obliquity did not change the tibiofemoral kinematics and stability of the knee joint in TKA candidates with knee osteoarthritis.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Amplitude de Movimento Articular/fisiologia
5.
SICOT J ; 9: 2, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36648275

RESUMO

PURPOSE: The relationship between spinopelvic mobility and dislocation in total hip arthroplasty (THA) has recently attracted attention. This study aimed to investigate the differences in sacral slope (SS) between two types of upright seated positions and to determine which seated position was appropriate for assessing spinopelvic mobility (change in SS from standing to sitting) before THA. MATERIALS AND METHODS: This prospective cohort study included 75 hips from 75 patients who had undergone primary THA. Each patient underwent preoperative lateral spinopelvic radiography in standing (st) and two seated positions: relaxed (rs) and straight (ss). The change in SS between each position (Δ) was measured. RESULTS: Differences in all spinopelvic sagittal alignment parameters between the two seated positions were statistically significant (p < 0.001). The range, median, and mean values of ΔSSss-rs were -2.0° to 26.5°, 6.8°, and 8.3°, respectively. ΔSSss-rs was significantly correlated with SS, LLA, and PFA in the relaxed seated position (r = -0.52, -0.39, and 0.37; p < 0.001, p < 0.001, and p = 0.001, respectively), but was not correlated to these parameters in the straight seated position. Of the 52 patients with normal spinopelvic mobility in the relaxed seated position (ΔSSst-rs > 10°), 24 (46%) patients were misrepresented as having a stiff spine in the straight seated position (ΔSSst-ss < 10°). CONCLUSION: The change in SS from the straight to the relaxed seated position widely varied in patients before THA. The spinopelvic radiograph in the relaxed seated position is appropriate when evaluating spinopelvic mobility for preoperative planning.

6.
Arch Orthop Trauma Surg ; 143(7): 4465-4472, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36261646

RESUMO

INTRODUCTION: It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS: Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS: The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (ß = 0.41, p < 0.01) and stem coronal alignment (ß = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION: The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Durapatita , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Desenho de Prótese
7.
Arch Orthop Trauma Surg ; 143(7): 4473-4480, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36322198

RESUMO

INTRODUCTION: No studies have compared the accuracy of acetabular cup placement in total hip arthroplasty (THA) in the supine and lateral decubitus positions using the same portable navigation system. Thus, this study aimed to compare the accuracy of acetabular cup placement using a new accelerometer-based portable navigation system combined with an infrared stereo camera and inertial measurement unit between the supine and lateral decubitus positions. MATERIALS AND METHODS: This retrospective study compared 45 THAs performed in the supine position (supine group) and 44 THAs performed in the lateral decubitus position (lateral group) using the same portable navigation system. The primary outcome was the absolute errors of cup placement angles, defined as the absolute values of the differences between cup radiographic inclination and anteversion angles displayed on the navigation system and those measured on postoperative computed tomography images. RESULTS: No significant difference in the median absolute error of the cup inclination angle (supine group 1.7° [interquartile range 0.8°-3.1°] vs. lateral group 2.1° [interquartile range 1.0°-3.7°]; p = 0.07) was found between the two groups. Similarly, no significant difference in the median absolute error of the anteversion angle (supine group 1.9° [interquartile range 0.8°-3.4°] vs. lateral group 2.1° [interquartile range 0.9°-3.1°]; p = 0.42) was found. CONCLUSION: This new accelerometer-based portable navigation system may provide high accuracy of the cup placement in THA in the lateral decubitus and supine positions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Decúbito Dorsal , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acelerometria
8.
Biochem Biophys Res Commun ; 597: 58-63, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35124460

RESUMO

Vitamin D has been shown to reduce symptoms in patients with osteoarthritis (OA). In a previous study, local administration of eldecalcitol, an active vitamin D3 analog, reduced degenerative changes in articular cartilage in the early phase of experimental OA. However, the target of vitamin D in OA remains unknown. Here, we investigated the effect of eldecalcitol treatment on chondrocytes, which were divided into superficial zone chondrocytes (SZC), deep zone chondrocytes (DZC), and differentiated chondrocytes. SZC and DZC were cultured in monolayer and 3D pellet cultures treated with eldecalcitol. The gene expressions of articular cartilage and chondrocyte differentiation markers were evaluated. Histological analysis of SZC and DZC 3D pellet cultures was performed. The results showed that the articular cartilage markers ETS-related gene (Erg) and lubricin/proteoglycan 4 (PRG4) were significantly increased in SZC, but not in DZC, in the monolayer culture treated with eldecalcitol. The chondrocyte differentiation markers type X collagen and alkaline phosphatase (ALP) were significantly decreased in the DZC pellet culture treated with eldecalcitol. Immunochemical analysis also showed that Erg and lubricin/PRG4 expressions were elevated in the SZC pellet culture treated with eldecalcitol, while type X collagen and ALP expressions were decreased in the DZC pellet culture treated with eldecalcitol. In conclusion, this study showed that eldecalcitol upregulated articular cartilage markers in SZC and suppressed differentiation markers in DZC. Such regulation of chondrocytes by eldecalcitol could be potentially effective against OA progression.

9.
Eur J Orthop Surg Traumatol ; 32(3): 551-557, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34043059

RESUMO

PURPOSE: Medial pivot total knee arthroplasty (MP-TKA) is characterized by the ball-in-socket medial tibiofemoral articulation to achieve low wear and to reproduce the medial pivot motion similar to that in the normal knee, and there have been reports of favorable long-term postsurgical outcomes. However, most of these cases concerned varus knees, and the outcomes of MP-TKA in valgus knees are unknown. The objective of this study was to investigate the postoperative outcomes in end-stage valgus knee OA patients who underwent MP-TKA, through comparisons with those who underwent TKA using the same prosthesis for varus deformity. METHODS: This retrospective, single-center, cohort study analyzed 171 knees of 121 patients who were divided into two groups (valgus knee group: 15 knees (13 patients), varus knee group: 156 knees (109 patients)). Primary outcome measures included the knee joint range of motion (evaluated preoperatively and at every year postoperatively). Secondary outcomes included operative time, laboratory data, estimated blood loss, clinical outcome measures and adverse events. RESULTS: There were no significant differences in age, sex and body mass index, as well as in the postoperative primary and secondary outcome measures between the two groups. CONCLUSION: The use of MP-TKA featuring ball-in-socket medial tibiofemoral articulation in patients with valgus knee OA showed equally favorable clinical outcomes more than 2 years after surgery, compared to patients with varus knees who received MP-TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
10.
Arthroplasty ; 3(1): 28, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35236482

RESUMO

BACKGROUND: It remains uncertain whether an increase in the tibial slope leads to better flexion in posterior-stabilized (PS) total knee prostheses. PURPOSE: To compare the intra-operative flexion angle between standard and an additional 10° posterior slope inserts. PATIENTS AND METHODS: Between December 2014 and February 2015, 22 patients (25 knees) who underwent PS mobile-bearing primary total knee arthroplasty (TKA) were included. Flexion angles were measured using either standard or specially-made inserts. Differences in flexion angles between the two situations were analyzed to determine the relationship between changes in flexion angle and pre-operative flexion angle or body mass index (BMI), and between intra- and post-operative flexion angle. RESULTS: The difference between the average flexion angle of standard inserts and specially-made inserts was not statistically significant. Although the correlations between changes in flexion angle due to insert difference and flexion angle, pre-operative flexion angle or BMI were not significant, there was a positive correlation between intra-operative and post-operative flexion at 2 years. CONCLUSION: The results showed an additional posterior tibial slope by 10° did not affect the intra-operative flexion angle. Surgeons performing PS mobile-bearing TKA do not need to excessively slope the tibial bone cutting to improve the post-operative flexion angle. LEVEL OF EVIDENCE: I, Experimental study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...