Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mol Reprod Dev ; 91(1): e23723, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38282316

RESUMO

The Sodium Glucose Cotransporter Isoform 1 (Sglt-1) is a symporter that moves Na+ and glucose into the cell. While most studies have focused on the role of Sglt-1 in the small intestine and kidney, little is known about this transporter's expression and function in other tissues. We have previously shown that Sglt-1 is expressed in the mouse sperm flagellum and that its inhibition interferes with sperm metabolism and function. Here, we further investigated the importance of Sglt-1 in sperm, using a Sglt-1 knockout mouse (Sglt-1 KO). RNA, immunocytochemistry, and glucose uptake analysis confirmed the ablation of Sglt-1 in sperm. Sglt-1 KO male mice are fertile and exhibit normal sperm counts and morphology. However, Sglt-1 null sperm displayed a significant reduction in total, progressive and other parameters of sperm motility compared to wild type (WT) sperm. The reduction in motility was exacerbated when sperm were challenged to swim in media with higher viscosity. Parameters of capacitation, namely protein tyrosine phosphorylation and acrosomal reaction, were similar in Sglt-1 KO and WT sperm. However, Sglt-1 KO sperm displayed a significant decrease in hyperactivation. The impaired motility of Sglt-1 null sperm was observed in media containing glucose as the only energy substrate. Interestingly, the addition of pyruvate and lactate to the media partially recovered sperm motility of Sglt-1 KO sperm, both in the low and high viscosity media. Altogether, these results support an important role for Sglt-1 in sperm energetics and function, providing sperm with a higher capacity for glucose uptake.


Assuntos
Transportador 1 de Glucose-Sódio , Motilidade dos Espermatozoides , Animais , Masculino , Camundongos , Glucose/metabolismo , Camundongos Knockout , Sêmen/metabolismo , Transportador 1 de Glucose-Sódio/genética , Transportador 1 de Glucose-Sódio/metabolismo , Capacitação Espermática/fisiologia , Motilidade dos Espermatozoides/fisiologia , Espermatozoides/metabolismo
2.
Int J Nanomedicine ; 16: 4739-4753, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267520

RESUMO

BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use. METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD). RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits. CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.


Assuntos
Ouro/química , Immunoblotting/métodos , Imunoglobulina G/análise , Nanopartículas Metálicas/química , Nucleocapsídeo/análise , SARS-CoV-2/isolamento & purificação , Adulto , Anticorpos Antivirais/sangue , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Valor Preditivo dos Testes , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Estudos Soroepidemiológicos
3.
J Inflamm Res ; 14: 2497-2506, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34163208

RESUMO

BACKGROUND: Dynamics and persistence of neutralizing and non-neutralizing antibodies can give us the knowledge required for serodiagnosis, disease management, and successful vaccine design and development. The disappearance of antibodies, absence of humoral immunity activation, and sporadic reinfection cases emphasize the importance of longitudinal antibody dynamics against variable structural antigens. METHODS: In this study, twenty-five healthy subjects working in a SARS-COV-2 serodiagnostic assay development project were enrolled, and their sign and symptoms were followed up to six months. Three subjects showed COVID-19-like symptoms, and three subjects' antibody dynamics were followed over 120 days by analyzing 516 samples. We have developed 12 different types of in-house ELISAs to observe the kinetics of IgG, IgM, and IgA against four SARS-CoV-2 proteins, namely nucleocapsid, RBD, S1, and whole spike (S1+S2). For the development of these assays, 30-104 pre-pandemic samples were taken as negative controls and 83 RT-qPCR positive samples as positive ones. RESULTS: All three subjects presented COVID-19-like symptoms twice, with mild symptoms in the first episode were severe in the second, and RT-qPCR confirmed the latter. The initial episode did not culminate with any significant antibody development, while a multifold increase in IgG antibodies characterized the second episode. Interestingly, IgG antibody development concurrent with IgM and IgA and persisted, whereas the latter two weans off rather quickly if appeared. CONCLUSION: Antibody kinetics observed in this study can provide a pathway to the successful development of sero-diagnostics and epidemiologists to predict the fate of vaccination currently in place.

4.
Infect Drug Resist ; 14: 1049-1082, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33762831

RESUMO

Recent severe acute respiratory syndrome 2 (SARS-CoV-2) known as COVID-19, presents a deadly challenge to the global healthcare system of developing and developed countries, exposing the limitations of health facilities preparedness for emerging infectious disease pandemic. Opportune detection, confinement, and early treatment of infected cases present the first step in combating COVID-19. In this review, we elaborate on various COVID-19 diagnostic tools that are available or under investigation. Consequently, cell culture, followed by an indirect fluorescent antibody, is one of the most accurate methods for detecting SARS-CoV-2 infection. However, restrictions imposed by the regulatory authorities prevented its general use and implementation. Diagnosis via radiologic imaging and reverse transcriptase PCR assay is frequently employed, considered as standard procedures, whereas isothermal amplification methods are currently on the verge of clinical introduction. Notably, techniques such as CRISPR-Cas and microfluidics have added new dimensions to the SARS-CoV-2 diagnosis. Furthermore, commonly used immunoassays such as enzyme-linked immunosorbent assay (ELISA), lateral flow immunoassay (LFIA), neutralization assay, and the chemiluminescent assay can also be used for early detection and surveillance of SARS-CoV-2 infection. Finally, advancement in the next generation sequencing (NGS) and metagenomic analysis are smoothing the viral detection further in this global challenge.

5.
PLoS One ; 16(2): e0246346, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33529223

RESUMO

BACKGROUND: In the ongoing pandemic situation of COVID-19, serological tests can complement the molecular diagnostic methods, and can be one of the important tools of sero-surveillance and vaccine evaluation. AIM: To develop and evaluate a rapid SARS-CoV-2 specific ELISA for detection of anti-SARS-CoV2 IgG from patients' biological samples. METHODS: In order to develop this ELISA, three panels of samples (n = 184) have been used: panel 1 (n = 19) and panel 2 (n = 60) were collected from RT-PCR positive patients within 14 and after 14 days of onset of clinical symptoms, respectively; whereas panel 3 consisted of negative samples (n = 105) collected either from healthy donors or pre-pandemic dengue patients. As a capturing agent full-length SARS-CoV2 specific recombinant nucleocapsid was immobilized. Commercial SARS-CoV2 IgG kit based on chemiluminescent assay was used for the selection of samples and optimization of the assay. The threshold cut-off point, inter-assay and intra-assay variations were determined. RESULTS: The incubation/reaction time was set at a total of 30 minutes with the sensitivity of 84% (95% confidence interval, CI, 60.4%, 96.6%) and 98% (95% CI, 91.1%, 100.0%), for panel 1 and 2, respectively; with overall 94.9% sensitivity (95% CI 87.5%, 98.6%). Moreover, the clinical specificity was 97.1% (95% CI, 91.9%, 99.4%) with no cross reaction with dengue samples. The overall positive and negative predictive values are 96.2% (95% CI 89.2%, 99.2%) and 96.2% (95% CI, 90.6% 99.0%), respectively. In-house ELISA demonstrated 100% positive and negative percent agreement with Elecsys Anti-SARS-CoV-2, with Cohen's kappa value of 1.00 (very strong agreement), while comparing 13 positive and 17 negative confirmed cases. CONCLUSION: The assay is rapid and can be applied as one of the early and retrospective sero-monitoring tools in all over the affected areas.


Assuntos
Anticorpos Antivirais/análise , Proteínas do Nucleocapsídeo de Coronavírus/análise , Ensaio de Imunoadsorção Enzimática/métodos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Humanos , Imunoglobulina G/análise , Fosfoproteínas/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...