Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BJOG ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560768

RESUMO

OBJECTIVE: To determine the incidence and sociodemographic and clinical risk factors associated with birth asphyxia and the immediate neonatal outcomes of birth asphyxia in Nigeria. DESIGN: Secondary analysis of data from the Maternal and Perinatal Database for Quality, Equity and Dignity Programme. SETTING: Fifty-four consenting referral-level hospitals (48 public and six private) across the six geopolitical zones of Nigeria. POPULATION: Women (and their babies) who were admitted for delivery in the facilities between 1 September 2019 and 31 August 2020. METHODS: Data were extracted and analysed on prevalence and sociodemographic and clinical factors associated with birth asphyxia and the immediate perinatal outcomes. Multilevel logistic regression modelling was used to ascertain the factors associated with birth asphyxia. MAIN OUTCOME MEASURES: Incidence, case fatality rate and factors associated with birth asphyxia. RESULTS: Of the available data, 65 383 (91.1%) women and 67 602 (90.9%) babies had complete data and were included in the analysis. The incidence of birth asphyxia was 3.0% (2027/67 602) and the case fatality rate was 16.8% (339/2022). The risk factors for birth asphyxia were uterine rupture, pre-eclampsia/eclampsia, abruptio placentae/placenta praevia, birth trauma, fetal distress and congenital anomaly. The following factors were independently associated with a risk of birth asphyxia: maternal age, woman's education level, husband's occupation, parity, antenatal care, referral status, cadre of health professional present at the birth, sex of the newborn, birthweight and mode of birth. Common adverse neonatal outcomes included: admission to a special care baby unit (SCBU), 88.4%; early neonatal death, 14.2%; neonatal sepsis, 4.5%; and respiratory distress, 4.4%. CONCLUSIONS: The incidence of reported birth asphyxia in the participating facilities was low, with around one in six or seven babies with birth asphyxia dying. Factors associated with birth asphyxia included sociodemographic and clinical considerations, underscoring a need for a comprehensive approach focused on the empowerment of women and ensuring access to quality antenatal, intrapartum and postnatal care.

2.
BJOG ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602158

RESUMO

OBJECTIVE: To examine the prevalence, perinatal outcomes and factors associated with neonatal sepsis in referral-level facilities across Nigeria. DESIGN: Secondary analysis of data from the Maternal and Perinatal Database for Quality, Equity and Dignity Programme in 54 referral-level hospitals across Nigeria. SETTING: Records covering the period from 1 September 2019 to 31 August 2020. POPULATION: Mothers admitted for birth during the study period, and their live newborns. METHODS: Analysis of prevalence and sociodemographic and clinical factors associated with neonatal sepsis and perinatal outcomes. Multilevel logistic regression modelling identified factors associated with neonatal sepsis. MAIN OUTCOME MEASURES: Neonatal sepsis and perinatal outcomes. RESULTS: The prevalence of neonatal sepsis was 16.3 (95% CI 15.3-17.2) per 1000 live births (1113/68 459) with a 10.3% (115/1113) case fatality rate. Limited education, unemployment or employment in sales/trading/manual jobs, nulliparity/grand multiparity, chronic medical disorder, lack of antenatal care (ANC) or ANC outside the birthing hospital and referral for birth increased the odds of neonatal sepsis. Birthweight of <2500 g, non-spontaneous vaginal birth, preterm birth, prolonged rupture of membranes, APGAR score of <7 at 5 min, birth asphyxia, birth trauma or jaundice were associated with neonatal sepsis. Neonates with sepsis were more frequently admitted to a neonatal intensive care unit (1037/1110, 93.4% vs 8237/67 346, 12.2%) and experienced a higher rate of death (115/1113, 10.3% vs 933/67 343, 1.4%). CONCLUSIONS: Neonatal sepsis remains a critical challenge in neonatal care, underscored by its high prevalence and mortality rate. The identification of maternal and neonatal risk factors underscores the importance of improved access to education and employment for women and targeted interventions in antenatal and intrapartum care.

3.
J Obstet Gynaecol Res ; 43(5): 825-833, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28422393

RESUMO

AIM: The aim of this study was to determine accuracy and response time of duo of insulin-like growth factor binding protein-1 (IGFBP-1)/alpha-fetoprotein (Amnioquick duo+) versus placental alpha-microglobulin-1 (PAMG-1) in diagnosing premature rupture of membranes (PROM). METHODS: A multicenter prospective study was conducted among women with features suggestive of PROM between 24 and 42 gestational weeks (GW). PROM was confirmed post-delivery based on presence of any two of these criteria: delivery within 48 h to 7 days, chorioamnionitis, membranes overtly ruptured at delivery, and adverse perinatal outcomes strongly correlated with prolonged PROM. Response time analysis was also done. Outcome measures included specificity, sensitivity, positive predictive value, negative predictive value, accuracy, and response time for both tests. RESULTS: Sensitivity, specificity, and accuracy for Amnioquick duo+ were 97.9%, 97.6%, and 97.9%, which were higher than the levels for PAMG-1, of 95.3%, 90.0%, and 95.7%, respectively (not significant). Accuracy of Amnioquick duo+ versus PAMG-1 in equivocal (pooling = negative) cases was (98.4% vs 96.8%) at ≥34 GW but each was 100.0% at <34 GW (not significant). Overall diagnostic concordance rate of Amnioquick duo+ and PAMG-1 was 97.0% and both have equal positive predictive value (99.5%). Response time analysis showed that the overall response time of PAMG-1 was 4.5% higher than that of Amnioquick duo+. CONCLUSION: This is the largest study to date to reveal that Amnioquick duo+ and PAMG-1 have a comparatively high diagnostic accuracy in identifying women with PROM, with a concordance rate of 97.0%. The diagnostic response time of Amnioquick duo+ appears shorter. In equivocal cases, accuracy of Amnioquick duo+ was equal to that of the PAMG-1.


Assuntos
Biomarcadores/metabolismo , Ruptura Prematura de Membranas Fetais/diagnóstico , Proteína 1 de Ligação a Fator de Crescimento Semelhante à Insulina/metabolismo , alfa-Fetoproteínas/metabolismo , Adulto , Feminino , Ruptura Prematura de Membranas Fetais/metabolismo , Humanos , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade
4.
J Perinat Med ; 45(1): 105-112, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27855117

RESUMO

PURPOSE: To determine the diagnostic accuracy of insulin-like growth factor binding protein-1/alpha fetoprotein (Amnioquick duo+®) compared with traditional clinical assessment (TCA) of nitrazine, ferning and pooling for the diagnosis of prelabor rupture of membranes (PROM). METHODS: A double-blinded, multicenter clinical study was conducted between February 2015 and August 2015 among pregnant women presenting with symptoms or features suggestive of PROM between 24 and 42 weeks gestation. Confirmation of PROM was done after delivery based on the presence of any two of these criteria: delivery within 48 h to 7 days, evidence of chorioamnionitis, membranes explicitly ruptured at delivery and adverse perinatal outcomes strongly correlated with prolonged PROM. Sensitivity, specificity and accuracy were outcome measures assessed. RESULTS: Two hundred and thirty-six women were recruited. Three women were excluded from the final analysis due to lack of follow-up data and failure to meet inclusion criteria. Two hundred and thirty-three women had complete data for analysis. The specificity and sensitivity values for TCA were 76.2% and 85.2%, which were lower than those of Amnioquick duo+, which were 97.6% and 97.9%, respectively. The accuracy of Amnioquick duo+ was statistically higher (97.9% vs. 83.7%; RR=1.17; 95%CI=1.10-1.24; P<0.001). In equivocal cases (pooling=negative), the accuracy of Amnioquick duo+ vs. TCA was 98.4% vs. 69.4% (RR=1.42; 95%CI=1.20-1.68; P<0.001) at ≥34 weeks gestation and 100.0% vs. 71.4% (RR=1.40; 95%CI=1.07-1.83; P=0.021) at <34 weeks gestation. CONCLUSION: The performance matrix of Amnioquick duo+® was superior to that of TCA for diagnosing PROM even in equivocal cases.


Assuntos
Ruptura Prematura de Membranas Fetais/diagnóstico , Imunoensaio/estatística & dados numéricos , Proteína 1 de Ligação a Fator de Crescimento Semelhante à Insulina/análise , alfa-Fetoproteínas/análise , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Imunoensaio/métodos , Valor Preditivo dos Testes , Gravidez , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...