Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 29(7)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38611776

RESUMO

The aim of this case study was the evaluation of the selected metals' concentration, potential toxic compound identification, cytotoxicity analysis, estimation of the airborne dust concentration, biodiversity, and number of microorganisms in the environment (leachate, soil, air) of the biggest uncontrolled post-industrial landfills in Poland. Based on the results obtained, preliminary solutions for the future management of post-industrial objects that have become an uncontrolled landfill were indicated. In the air, the PM1 fraction dominated, constituting 78.1-98.2% of the particulate matter. Bacterial counts were in the ranges of 9.33 × 101-3.21 × 103 CFU m-3 (air), 1.87 × 105-2.30 × 106 CFU mL-1 (leachates), and 8.33 × 104-2.69 × 106 CFU g-1 (soil). In the air, the predominant bacteria were Cellulosimicrobium and Stenotrophomonas. The predominant fungi were Mycosphaerella, Cladosporium, and Chalastospora. The main bacteria in the leachates and soils were Acinetobacter, Mortierella, Proteiniclasticum, Caloramator, and Shewanella. The main fungi in the leachates and soils were Lindtneria. Elevated concentrations of Pb, Zn, and Hg were detected. The soil showed the most pronounced cytotoxic potential, with rates of 36.55%, 63.08%, and 100% for the A-549, Caco-2, and A-549 cell lines. Nine compounds were identified which may be responsible for this cytotoxic effect, including 2,4,8-trimethylquinoline, benzo(f)quinoline, and 1-(m-tolyl)isoquinoline. The microbiome included bacteria and fungi potentially metabolizing toxic compounds and pathogenic species.


Assuntos
Poeira , Mercúrio , Humanos , Células CACO-2 , Metais , Solo
2.
Med Pr ; 74(5): 363-375, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38104337

RESUMO

BACKGROUND: The study aimed to evaluate the effectiveness of filtering facepiece respirators (FFRs) in reducing odour nuisances in agricultural work environment. Additionally, an assessment was conducted on the microbiological contamination of FFRs and the functionality of Time4Mask application in enhancing workplace safety. MATERIAL AND METHODS: Two types of FFRs were used for the study: with absorbing properties and reference ones. The research was carried out in 6 livestock rooms during a 1-week period in early spring (February-March 2021) on a farm in central Poland. The microclimate conditions (thermoanemometer), and particulate matter concentrations (laser photometer) were assessed. Additionally, the odour content in the studied rooms and the breathing zone of FFR users (gas chromatography with mass spectrometry) were evaluated. The number of microorganisms on the respirators was determined (cultivation method), followed by their identification (biochemical tests, taxonomic keys). Breakthrough curves were determined for both FFR types to assess absorption capabilities. RESULTS: The average temperature in the livestock rooms was about 13°C, relative humidity - 53%, air flow velocity - 0.21 m/s, and particulate matter concentration - 0.216 mg/m3. A significant variety of odorants was found in the environment and the breathing zone under the FFRs. Bacterial counts ranged between 2.4 × 101 and 2.6 × 102 CFU/cm2, fungi between 3.2 × 100 and 5.4 × 101 CFU/cm2, xerophilic fungi from 4.4 × 100 to 4.0 × 101 CFU/cm2, mannitol-positive staphylococci between 1.6 × 101 and 1.0 × 102 CFU/cm2, and haemolytic staphylococci from 2.2 × 101 to 4.5 × 101 CFU/cm2, depending on the respirator type. Respirators were colonized by bacteria from the genera: Bacillus, Staphylococcus, actinobacteria Streptomyces sp., and fungi: Candida, Absidia, Aspergillus, Mucor, and Penicillium. Respirators with absorbing properties had over 8-times longer breakthrough time than reference ones. CONCLUSIONS: Respirators with activated carbon effectively improved work comfort when exposed to odours. Due to growth of microorganisms in the respirator materials, periodic replacement is necessary. It is crucial to provide workers with information about the safe-use time of respirators, considering environmental conditions. This is achievable using modern IT tools like Time4Mask application. Med Pr Work Health Saf. 2023;76(5):363-75.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Humanos , Poluentes Ocupacionais do Ar/análise , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Odorantes/análise , Cromatografia Gasosa-Espectrometria de Massas , Material Particulado/análise , Ventiladores Mecânicos , Fungos , Bactérias
3.
Molecules ; 28(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37110794

RESUMO

This study aimed to assess the markers of chemical and microbiological contamination of the air at sport centers (e.g., the fitness center in Poland) including the determination of particulate matter, CO2, formaldehyde (DustTrak™ DRX Aerosol Monitor; Multi-functional Air Quality Detector), volatile organic compound (VOC) concentration (headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry), the number of microorganisms in the air (culture methods), and microbial biodiversity (high-throughput sequencing on the Illumina platform). Additionally the number of microorganisms and the presence of SARS-CoV-2 (PCR) on the surfaces was determined. Total particle concentration varied between 0.0445 mg m-3 and 0.0841 mg m-3 with the dominance (99.65-99.99%) of the PM2.5 fraction. The CO2 concentration ranged from 800 ppm to 2198 ppm, while the formaldehyde concentration was from 0.005 mg/m3 to 0.049 mg m-3. A total of 84 VOCs were identified in the air collected from the gym. Phenol, D-limonene, toluene, and 2-ethyl-1-hexanol dominated in the air at the tested facilities. The average daily number of bacteria was 7.17 × 102 CFU m-3-1.68 × 103 CFU m-3, while the number of fungi was 3.03 × 103 CFU m-3-7.34 × 103 CFU m-3. In total, 422 genera of bacteria and 408 genera of fungi representing 21 and 11 phyla, respectively, were detected in the gym. The most abundant bacteria and fungi (>1%) that belonged to the second and third groups of health hazards were: Escherichia-Shigella, Corynebacterium, Bacillus, Staphylococcus, Cladosporium, Aspergillus, and Penicillium. In addition, other species that may be allergenic (Epicoccum) or infectious (Acinetobacter, Sphingomonas, Sporobolomyces) were present in the air. Moreover, the SARS-CoV-2 virus was detected on surfaces in the gym. The monitoring proposal for the assessment of the air quality at a sport center includes the following markers: total particle concentration with the PM2.5 fraction, CO2 concentration, VOCs (phenol, toluene, and 2-ethyl-1-hexanol), and the number of bacteria and fungi.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Fungos Mitospóricos , Exposição Ocupacional , Exposição Ocupacional/análise , Dióxido de Carbono/análise , Microbiologia do Ar , COVID-19/epidemiologia , SARS-CoV-2 , Aerossóis e Gotículas Respiratórios , Fungos , Bactérias , Material Particulado/análise , Fenóis/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental
4.
Environ Res ; 228: 115825, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37011789

RESUMO

This study focused on assessing the microbiological and chemical contamination of air, soil and leachate in uncontrolled refuse storage areas in central Poland. The research included an analysis of the number of microorganisms (culture method), endotoxin concentration (gas chromatography-mass spectrometry), heavy metals level (atomic absorption spectrometry), elemental characteristics (elemental analyser), cytotoxicity assessment against A-549 (human lung) and Caco-2 (human colon adenocarcinoma) cell lines (PrestoBlue™ test) and toxic compound identification (ultra-high-performance liquid chromatography-quadrupole time-of-flight ultrahigh-resolution mass spectrometry). Microbial contamination differed depending on the dump and the group of tested microorganisms. The number of bacteria was: 4.3 × 102 - 1.8 × 103 CFU m-3 (air); 1.1 × 103 - 1.2 × 106 CFU mL-1 (leachate); 1.0 × 106 - 3.9 × 106 CFU g-1 (soil). Respectively, for air and soil the number of fungi was: 2.2 × 102 - 4.6 × 102 CFU m-3; 1.8 × 102 - 3.9 × 103 CFU g-1. Metal levels (Fe, Mn, Pb, Zn, Al, Hg, Cd, Cu, Cr) were higher than in the control sample; however, the average concentrations did not exceed the permissible standards. The cytotoxicity of soil and leachate samples depended on the dump, sample and cell line tested. The leachates were more cytotoxic than soil extracts. Compounds belonging to pesticides, surfactants and biocides, chemicals and/or polymer degradation products, medicinal drugs and insect repellents were found. The detection of potential pathogens in the air, soil and leachate, the presence of toxic compounds and the confirmation of the cytotoxic effect of leachate and soil on human cell lines justify the need for further research on the risks posed by illegal dumps. These studies should aim at developing a unified assessment method and a method to minimise the risk of contaminants spreading in the environment, including harmful biological agents.


Assuntos
Adenocarcinoma , Neoplasias do Colo , Metais Pesados , Poluentes do Solo , Humanos , Polônia , Células CACO-2 , Poluentes do Solo/toxicidade , Poluentes do Solo/análise , Monitoramento Ambiental/métodos , Metais Pesados/toxicidade , Metais Pesados/análise , Solo/química , Medição de Risco
5.
Artigo em Inglês | MEDLINE | ID: mdl-36674305

RESUMO

The aim of this study was to analyse the quality of indoor air in sport facilities in one of the sport centres in Poland with respect to microclimatic parameters (temperature, humidity, and air flow velocity), particulate matter concentrations (PM10, PM4, PM2.5, and PM1), gas concentrations (oxygen, ozone, hydrogen sulphide, sulphur dioxide, volatile organic compounds, and benzopyrene), and microbial contamination (the total number of bacteria, specifically staphylococci, including Staphylococcus aureus, haemolytic bacteria, Enterobacteriaceae, Pseudomonas fluorescens, actinomycetes, and the total number of fungi and xerophilic fungi). Measurements were made three times in May 2022 at 28 sampling points in 5 different sporting areas (the climbing wall, swimming pool, swimming pool changing room, and basketball and badminton courts) depending on the time of day (morning or afternoon) and on the outside building. The obtained results were compared with the standards for air quality in sports facilities. The air temperature (21−31 °C) was at the upper limit of thermal comfort, while the air humidity (RH < 40%) in the sports halls in most of the locations was below demanded values. The values for dust pollution in all rooms, except the swimming pool, exceeded the permissible limits, especially in the afternoons. Climatic conditions correlated with a high concentration of dust in the indoor air. Particulate matter concentrations of all fractions exceeded the WHO guidelines in all researched premises; the largest exceedances of standards occurred for PM2.5 (five-fold) and for PM10 (two-fold). There were no exceedances of gaseous pollutant concentrations in the air, except for benzopyrene, which resulted from the influence of the outside air. The total number of bacteria (5.1 × 101−2.0 × 104 CFU m−3) and fungi (3.0 × 101−3.75 × 102 CFU m−3) was exceeded in the changing room and the climbing wall hall. An increased number of staphylococci in the afternoon was associated with a large number of people training. The increased concentration of xerophilic fungi in the air correlated with the high dust content and low air humidity. Along with the increase in the number of users in the afternoon and their activities, the concentration of dust (several times) and microorganisms (1−2 log) in the air increased by several times and 1−2 log, respectively. The present study indicates which air quality parameters should be monitored and provides guidelines on how to increase the comfort of those who practice sports and work in sports facilities.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Basquetebol , Humanos , Poeira/análise , Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Dióxido de Enxofre/análise , Benzopirenos/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos
6.
Front Public Health ; 11: 1330430, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38288426

RESUMO

Purpose: The research purpose is to improve the management of occupational risks associated with hazards as well as the organization's capabilities to identify hazardous factors (HFs) using the "BOW-TIE" method in accordance with the provisions of the ISO 45001:2019 standard. Methods: To improve occupational risk management, the "BOW-TIE" method has been introduced into occupational health and safety management systems. This approach facilitates a comprehensive description and analysis of potential risk development from identifying hazardous factors to studying the consequences. It visually integrates fault and event trees to provide a holistic view of risk dynamics. Results: The improvement of the occupational hazard risk management process considers both internal and external factors affecting the organization, thereby increasing the probability and severity of potential hazardous events. The revised approach categorizes risk levels as acceptable, unacceptable, or verifiable. In addition, occupational risk management requires an in-depth analysis of the organization's external and internal environment to identify hazards that affect the probability and severity of potential hazardous events. Conclusion: This research proposes an innovative approach to occupational risk management by determining the magnitude of occupational risk as the cumulative result of assessing risks associated with all external and internal factors influencing the probability of hazardous event occurring. The introduction of the "BOW-TIE" method, combined with a comprehensive analysis of the organizational environments, facilitates a more effective and nuanced approach to occupational risk management.


Assuntos
Saúde Ocupacional , Gestão de Riscos , Medição de Risco/métodos , Gestão de Riscos/métodos , Gestão da Segurança/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-35457694

RESUMO

This study aimed to assess the physicochemical, microbiological and toxicological hazards at an illegal landfill in central Poland. The research included the analysis of airborne dust (laser photometer), the number of microorganisms in the air, soil and leachate (culture method) and the microbial diversity in the landfill environment (high-throughput sequencing on the Illumina Miseq); the cytotoxicity (PrestoBlue) and genotoxicity (alkaline comet assay) of soil and leachate were tested. Moreover, an analysis of UHPLC-Q-ToF-UHRMS (ultra-high-performance liquid chromatography-quadrupole-time-of-flight ultrahigh-resolution mass spectrometry) was performed to determine the toxic compounds and microbial metabolites. The PM1 dust fraction constituted 99.89% and 99.99% of total dust and exceeded the threshold of 0.025 mg m-3 at the tested locations. In the air, the total number of bacteria was 9.33 × 101-1.11 × 103 CFU m-3, while fungi ranged from 1.17 × 102 to 4.73 × 102 CFU m-3. Psychrophilic bacteria were detected in the largest number in leachates (3.3 × 104 to 2.69 × 106 CFU mL-1) and in soil samples (8.53 × 105 to 1.28 × 106 CFU g-1). Bacteria belonging to Proteobacteria (42-64.7%), Bacteroidetes (4.2-23.7%), Actinobacteria (3.4-19.8%) and Firmicutes (0.7-6.3%) dominated. In the case of fungi, Basidiomycota (23.3-27.7%), Ascomycota (5.6-46.3%) and Mortierellomycota (3.1%) have the highest abundance. Bacteria (Bacillus, Clostridium, Cellulosimicrobium, Escherichia, Pseudomonas) and fungi (Microascus, Chrysosporium, Candida, Malassezia, Aspergillus, Alternaria, Fusarium, Stachybotrys, Cladosporium, Didymella) that are potentially hazardous to human health were detected in samples collected from the landfill. Tested leachates and soils were characterised by varied cyto/genotoxins. Common pesticides (carbamazepine, prometryn, terbutryn, permethrin, carbanilide, pyrethrin, carbaryl and prallethrin), quaternary ammonium compounds (benzalkonium chlorides), chemicals and/or polymer degradation products (melamine, triphenylphosphate, diphenylphtalate, insect repellent diethyltoluamide, and drugs (ketoprofen)) were found in soil and leachate samples. It has been proven that the tested landfill is the source of the emission of particulate matter; microorganisms (including potential pathogens) and cyto/genotoxic compounds.


Assuntos
Microbiologia do Ar , Poeira , Bactérias , Poeira/análise , Fungos , Humanos , Polônia , Solo , Instalações de Eliminação de Resíduos
8.
Int J Occup Saf Ergon ; 28(1): 62-67, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34162316

RESUMO

This article presents paraffin oil mist penetration tests of commercially available air-purifying respirators of different construction conducted using the method described by Standard No. ISO 16900-3:2012, which incorporates flow rates (up to 255 l/min) of test aerosol. The testing method reflects differences in work intensity during the use of respirators. Moreover, the experimental stand, designed according to the international specifications, is described. The results show that the higher the paraffin oil mist flow rate, the higher the penetration index, irrespective of the testing method used and the type of respirator investigated. While at high flow rates, filtering half masks of the first protection class (FFP1) met the requirements of their protection class according to European Standard No. EN 149:20001+A1:2009, filtering half masks of the second and the third protection class (FFP2 and FFP3) did not.


Assuntos
Dispositivos de Proteção Respiratória , Aerossóis , Humanos , Óleos , Parafina
9.
J Environ Manage ; 303: 114257, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34920354

RESUMO

Even though biological hazards in the work environments related to waste management were the subject of many scientific works, the knowledge of the topic is not extensive. This study aimed to conduct a comprehensive assessment of microbiological and toxicological hazards at the workstations in a waste sorting plant and develop guidelines for selecting filtering respiratory protective devices that would consider specific workplace conditions. The research included the assessment of quantity (culture method), diversity (high-throughput sequencing), and metabolites (endotoxin - gas chromatography-mass spectrometry; secondary metabolites - liquid chromatography tandem-mass spectrometry) of microorganisms occurring in the air and settled dust. Moreover, cytotoxicity of settled dust against a human epithelial lung cell line was determined with an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay. The research was performed in a waste sorting plant (Poland; 240,000 tons waste/year) at six workstations: two feeders, two pre-sorting cabins, secondary raw material press and organic fraction waste feeder for composting. The total dust concentration at tested workstations varied from 0.128 mg m-3 to 5.443 mg m-3. The number of microorganisms was between 9.23 × 104 CFU m-3 and 1.38 × 105 CFU m-3 for bacteria and between 1.43 × 105 CFU m-3 and 1.65 × 105 CFU m-3 for fungi, which suggests high microbial contamination of the sorting facility. The numbers of microorganisms in the air correlated very strongly (R2 from 0.70 to 0.94) with those observed in settled dust. Microorganisms representing Group 2 biological agents (acc. to Directive, 2000/54/EC), including Corynebacterium spp., Pseudomonas aeruginosa, Staphylococcus aureus, and others potentially hazardous to human health, were identified. The endotoxins concentration in settled dust ranged from 0.013 nmol LPS mg-1 to 0.048 nmol LPS mg-1. Seventeen (air) and 91 (settled dust) secondary metabolites characteristic, e.g., for moulds, bacteria, lichens, and plants were identified. All dust samples were cytotoxic (IC50 values of 8.66 and 56.15 mg ml-1 after 72 h). A flowchart of respiratory protective devices selection for biological hazards at the workstations in the waste sorting plant was proposed based on the completed tests to help determine the right type and use duration of the equipment.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Bactérias , Poeira/análise , Fungos , Humanos
10.
Toxins (Basel) ; 13(10)2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34678984

RESUMO

Despite the awareness that work in the sewage treatment plant is associated with biological hazards, they have not been fully recognised so far. The research aims to comprehensively evaluate microbiological and toxicological hazards in the air and settled dust in workstations in a sewage treatment plant. The number of microorganisms in the air and settled dust was determined using the culture method and the diversity was evaluated using high-throughput sequencing. Endotoxin concentration was assessed with GC-MS (gas chromatography-mass spectrometry) while secondary metabolites with LC-MS/MS (liquid chromatography coupled to tandem mass spectrometry). Moreover, cytotoxicity of settled dust against a human lung epithelial lung cell line was determined with the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay and UHPLC-Q-ToF-UHRMS (ultra-high-performance liquid chromatography-quadrupole time-of-flight ultrahigh-resolution mass spectrometry) analysis was performed to determine the source of cytotoxicity. The total dust concentration in the sewage treatment plant was low and ranged from 0.030 mg m-3 to 0.044 mg m-3. The highest microbiological contamination was observed in sludge thickening building and screenings storage. Three secondary metabolites were detected in the air and sixteen in the settled dust. They were dominated by compounds typical of lichen and plants and Aspergillus, Penicillium and Fusarium genera mould. The settled dust from the sludge thickening building revealed high cytotoxicity to human lung epithelial cells A-549 (IC50 = 6.98 after 72 h). This effect can be attributed to a biocidal compound-didecyldimethylammonium chloride (DDAC-C10) and seven toxic compounds: 4-hydroxynonenal, carbofuran, cerulenin, diethylphosphate, fenpropimorph, naphthalene and onchidal. The presence of DDAC-C10 and other biocidal substances in the sewage treatment plant environment may bring negative results for biological sewage treatment and the natural environment in the future and contribute to microorganisms' increasing antibiotics resistance. Therefore, the concentration of antibiotics, pesticides and disinfectants in sewage treatment plant workstations should be monitored.


Assuntos
Aerossóis/análise , Poeira/análise , Exposição Ocupacional/análise , Eliminação de Resíduos Líquidos , Aerossóis/toxicidade , Microbiologia do Ar , Linhagem Celular , Desinfetantes/análise , Endotoxinas/análise , Monitoramento Ambiental , Humanos , Esgotos/química , Esgotos/microbiologia , Purificação da Água
11.
Artigo em Inglês | MEDLINE | ID: mdl-34360450

RESUMO

Filtering facepiece respirators (FFR) with anti-odor properties are used to reduce odor nuisance occurring both in everyday life and at workplaces. Unfortunately, there are no standardized methods to measure the efficiency of odor reduction of such personal protective devices. This paper aims to determine whether olfactometric-based methods, commonly used in environmental studies, can be employed for this purpose. The proposed procedure is based on the detection of n-butanol by study participants, and it consists of three subsequent stages: (i) defining the individual levels of odor sensitivity of each study participant; (ii) determining THE odor detection level while using FFRs with varying anti-odor properties; and (iii) completing a questionnaire concerning the subjective perceptions of study participants. As a measure of odor reduction efficiency, a coefficient W, defined as a quotient of the degree of odor reduction by the FFR, and the individual odor sensitivity of the subject, was proposed. The experimental results showed the ability of our measure to differentiate the effectiveness of odor reduction of tested FFRs. This indicates that it can be potentially employed as the assessment tool to confirm the effectiveness of such respiratory protective devices as a control measure mitigating the adverse effects of malodors on workers' health, cognition, and behavior.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Carvão Vegetal , Filtração , Humanos , Exposição Ocupacional/análise , Odorantes , Olfatometria , Ventiladores Mecânicos
12.
Materials (Basel) ; 14(7)2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33805934

RESUMO

A key factor in effective protection against airborne hazards, i.e., biological and nonbiological aerosols, vapors, and gases, is a good face fit of respiratory protective devices (RPDs). Equally important is the comfort of use, which may encourage or discourage users from donning RPDs. The objective of the work was to develop viscoelastic polyurethane foams for use in RPD seals. The obtained foams were characterized using scanning electron microscopy, infrared spectroscopy, thermogravimetry, and differential scanning calorimetry. Measurements also involved gel fraction, apparent density, air permeability, elastic recovery time, compression set, rebound resilience, and sweat uptake. The results were discussed in the context of modifications to the foam formulation: the isocyanate index (INCO) in the range of 0.6-0.9 and the blowing agent content in the range of 1.2-3.0 php. FTIR analysis revealed a higher level of urea groups with increasing water content in the formulation. Higher INCO and water content levels also led to lower onset temperatures of thermal degradation and higher glass-transition temperatures of the soft phase. A decrease in apparent density and an increase in mean pore sizes of the foams with increasing INCO and water content levels was observed. Functional parameters (air permeability, elastic recovery time, compression set, rebound resilience, and sweat uptake) were also found to be satisfactory at lower INCO and water content levels.

13.
Materials (Basel) ; 15(1)2021 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-35009298

RESUMO

Consistent and proper use of respiratory protective devices (RPD) is one of the essential actions that can be taken to reduce the risk of exposure to airborne hazards, i.e., biological and nonbiological aerosols, vapours, and gases. Proper fit of the facepiece and comfort properties of RPDs play a crucial role in effective protection and acceptance of RPDs by workers. The objective of the present paper was to develop viscoelastic polyurethane foams for use in RPD seals characterised by proper elasticity, allowing for the enhancement of the device fit to the face and the capability of removing moisture from the skin in order to improve the comfort of RPD use. Moreover, it was pivotal to ensure the non-flammability of the foams, as well as a simultaneous reduction in their cytotoxicity. The obtained foams were characterised using scanning electron microscopy, infrared spectroscopy, thermogravimetry, and differential scanning calorimetry. Measurements also involved gel fraction, apparent density, compression set, rebound resilience, wettability, flammability, and cytotoxicity. The results are discussed in the context of the impact of modifications to the foam formulation (i.e., flame-retardant type and content) on the desired foam properties. The test results set directions for future works aimed to develop viscoelastic polyurethane foams that could be applied in the design of respiratory protective devices.

15.
Front Neuroanat ; 14: 56, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33013328

RESUMO

In therian mammals, the cerebellum is one of the late developing structures in the brain. Specifically, the proliferation of cerebellar granule cells occurs after birth, and even in humans, the generation of these cells continues during the first year of life. The main difference between marsupials and eutherians is that the majority of the brain structures in marsupials develop after birth. Herein, we report that in the newborn laboratory opossum (Monodelphis domestica), the cerebellar primordium is distinguishable in Nissl-stained sections. Additionally, bromodeoxyuridine birthdating experiments revealed that the first neurons form the deep cerebellar nuclei (DCN) and Purkinje cells, and are generated within postnatal days (P) 1 and 5. Three weeks after birth, progenitors of granule cells in the external germinal layer (EGL) proliferate, producing granule cells. These progenitor cells persist for a long time, approximately 5 months. Furthermore, to study the effects of neurotrophic tropomyosin receptor kinase C (TrkC) during cerebellar development, cells were obtained from P3 opossums and cultured for 8 days. We found that TrkC downregulation stimulates dendritic branching of Purkinje neurons, which was surprising. The number of dendritic branches was higher in Purkinje cells transfected with the shRNA TrkC plasmid. However, there was no morphological change in the number of dendritic branches of granule cells transfected with either control or shRNA TrkC plasmids. We suggest that inhibition of TrkC activity enables NT3 binding to the neurotrophic receptor p75NTR that promotes dendritic arborization of Purkinje cells. This effect of TrkC receptors on dendritic branching is cell type specific, which could be explained by the strong expression of TrkC in Purkinje cells but not in granule cells. The data indicate a new role for TrkC receptors in Monodelphis opossum.

16.
Molecules ; 24(18)2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31540285

RESUMO

Studies on the functionalization of materials used for the construction of filtering facepiece respirators (FFRs) relate to endowing fibers with biocidal properties. There is also a real need for reducing moisture content accumulating in such materials during FFR use, as it would lead to decreased microorganism survival. Thus, in our study, we propose the use of superabsorbent polymers (SAPs), together with a biocidal agent (biohalloysite), as additives in the manufacturing of polypropylene/polyester (PP/PET) multifunctional filtering material (MFM). The aim of this study was to evaluate the MFM for stability of the modifier's attachment to the polymer matrix, the degree of survival of microorganisms on the nonwoven, and its microorganism filtration efficiency. Scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were used to test the stability of the modifier's attachment. The filtration efficiency was determined under conditions of dynamic aerosol flow of S. aureus bacteria. The survival rates (N%) of the following microorganisms were assessed: Escherichia coli and Staphylococcus aureus bacteria, Candida albicans yeast, and Aspergillus niger mold using the AATCC 100-2004 method. FTIR spectrum analysis confirmed the pre-established composition of MFM. The loss of the active substance from MFM in simulated conditions of use did not exceed 0.02%, which validated the stability of the modifier's attachment to the PP/PET fiber structure. SEM image analysis verified the uniformity of the MFM structure. Lower microorganism survival rates were detected for S. aureus, C. albicans, and E. coli on the MFM nonwoven compared to control samples that did not contain the modifiers. However, the MFM did not inhibit A. niger growth. The MFM also showed high filtration efficiency (99.86%) against S. aureus bacteria.


Assuntos
Desinfetantes/farmacologia , Viabilidade Microbiana/efeitos dos fármacos , Polipropilenos/síntese química , Aspergillus niger/efeitos dos fármacos , Aspergillus niger/crescimento & desenvolvimento , Candida albicans/efeitos dos fármacos , Candida albicans/crescimento & desenvolvimento , Desinfetantes/química , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Filtração/instrumentação , Microscopia Eletrônica de Varredura , Polímeros , Polipropilenos/química , Dispositivos de Proteção Respiratória/microbiologia , Espectroscopia de Infravermelho com Transformada de Fourier , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento
17.
Artigo em Inglês | MEDLINE | ID: mdl-31394819

RESUMO

Bioaerosol is a threat at workplaces, therefore the selection and safe use of filtering facepiece respirators (FFRs) is important in preventive activities. The aim of the study was to assess the survival of microorganisms on materials used for FFRs construction. The parameters for microorganism growth under model conditions were described using the Gompertz equation, model verification was also carried out using FFRs at the farmers' workplaces. We found that the factors determining a high survival of microorganisms were as follows: moisture corresponding to the conditions of use and storage of FFRs at workplaces, the presence of sweat and organic dust; inorganic dust and addition of biocide in nonwovens limited the growth of microorganisms, resulting in a shortening of the stationary growth phase and decreased cell numbers (5-6 log). Dust concentration at workplaces was higher than EU occupational exposure limit values and WHO recommendations for airborne particulate matter. Microbial contaminations of the air (103-104 CFU/m3), settled dust (104-106 CFU/g) and FFRs (105 CFU/4cm2) during the grain harvest were high, the main contamination being bacteria (actinomycetes, Pseudomonas fluorescens) and xerophilic fungi. A high correlation was found between the number of microorganisms and the weight of dust on FFRs (R2 = 0.93-0.96).


Assuntos
Agricultura , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Exposição Ocupacional/análise , Dispositivos de Proteção Respiratória/microbiologia , Humanos , Local de Trabalho
18.
Artigo em Inglês | MEDLINE | ID: mdl-31167357

RESUMO

Filtering nonwovens loaded with activated carbon are among the most popular materials used in the construction of filtering facepiece respirators (FFRs) with anti-odour properties that can be used for respiratory protection at workplaces where the occupational exposure limits of harmful substances are not exceeded. Such FFRs, in addition to a polymer filter material of varying effectiveness, also contain a layer of activated-carbon-loaded nonwoven filter, which limits the quantity of chemical compounds entering the breathing zone. The aim of this work was to analyse the influence of challenge concentration (20-120 ppm), relative humidity (2-70%), flow rate (20-55 L/min), and flow pattern (steady-state and pulsating) on the breakthrough of polymer/carbon nonwovens. A commercial activated-carbon-loaded nonwoven filter was used in this study. Its morphology and textural parameters were determined using optical microscopy, image processing, and nitrogen adsorption/desorption measurements at 77 K. Breakthrough experiments were carried out using cyclohexane vapours to assess adsorption characteristics of polymer/carbon media. The results showed that the breakthrough times decreased with increasing challenge concentration (up to 30%), relative humidity (up to 73%), and flow rate (up to 72%). The pulsating flow pattern was found to be more favourable in terms of odour reduction efficiency (up to 30%). The results indicate that all of these factors should be considered during selection and performance assessment of respirators used for odour relief.


Assuntos
Adsorção , Filtros de Ar , Carvão Vegetal/química , Dispositivos de Proteção Respiratória , Poluentes Ocupacionais do Ar , Filtração , Humanos , Umidade , Processamento de Imagem Assistida por Computador/métodos , Microscopia , Exposição Ocupacional/análise , Local de Trabalho
19.
Work ; 63(1): 125-135, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31127750

RESUMO

BACKGROUND: The main function of respiratory protective devices is to provide an intact physical barrier between the environment and the user. To ensure that, a leak-tight fit of the facepiece to the user's face is essential, regardless of the user's individual facial features. OBJECTIVE: The main objective of this study was to assess the possibilities of developing customized respirators well-fitting to the anthropometric dimensions of the user's face using 3D scanning and 3D printing techniques and to evaluate this custom-made device in terms of protective, usage and strength parameters. METHODS: Commercially available twin-filter half-mask type MP22/2 was selected as base model for customization. The 3D scans of the half-mask facepiece were performed using ATOS Core optical 3D scanner. Simultaneously anthropometric measurements of the test subject face were carried out with hand-held 3D scanner Artec EVA. Then digital model of the facepiece was matched to the shape of user's face using Geomagic Touch X haptic device. Customized facepieces were printed out with use of selective laser sintering technique from thermoplastic polyurethane. After assembling, respirators were tested for compliance with the requirements of the European standards. RESULTS: The developed respirators proved to be very well-fitted to the user's face, did not cause any imprints or skin irritations and were assessed positively in terms of protective, usage and strength parameters. CONCLUSIONS: The application of 3D scanning and 3D printing techniques for designing and fabricating customized half-mask facepieces constitutes a viable option for the future development of respiratory protective devices.


Assuntos
Face/anormalidades , Máscaras/normas , Desenho de Prótese/normas , Antropometria/métodos , Desenho de Equipamento/métodos , Desenho de Equipamento/normas , Face/fisiopatologia , Humanos , Projetos Piloto , Impressão Tridimensional/instrumentação , Impressão Tridimensional/tendências , Desenho de Prótese/métodos , Ajuste de Prótese/métodos , Ajuste de Prótese/normas , Dispositivos de Proteção Respiratória/efeitos adversos , Dispositivos de Proteção Respiratória/normas
20.
Artigo em Inglês | MEDLINE | ID: mdl-30935098

RESUMO

Filtering nonwovens that constitute the base material for filtering facepiece respirators (FFRs) used for the protection of the respiratory system against bioaerosols may, in favourable conditions, promote the development of harmful microorganisms. There are no studies looking at the impact that different types of filtering nonwovens have on microorganism survival, which is an important issue for FFR producers and users. Five commercial filtering nonwovens manufactured using diverse textile technologies (i.e., needle-punching, melt-blown, spun-bonding) with different structural parameters and raw material compositions were used within our research. The survival of microorganisms on filtering nonwovens was determined for E. coli, S. aureus, B. subtilis bacteria; C. albicans yeast and A. niger mould. Samples of nonwovens were collected immediately after inoculum application (at 0 h) and after 4, 8, 24, 48, 72, and 96 h of incubation. The tests were carried out in accordance with the AATCC 100-1998 method. Survival depended strongly on microorganism species. E. coli and S. aureus bacteria grew the most on all nonwovens tested. The structural parameters of the nonwovens tested (mass per unit area and thickness) and contact angle did not significantly affect microorganism survival.


Assuntos
Aspergillus niger/fisiologia , Bacillus subtilis/fisiologia , Candida albicans/fisiologia , Escherichia coli/fisiologia , Dispositivos de Proteção Respiratória/microbiologia , Staphylococcus aureus/fisiologia , Aspergillus niger/crescimento & desenvolvimento , Bacillus subtilis/crescimento & desenvolvimento , Candida albicans/crescimento & desenvolvimento , Escherichia coli/crescimento & desenvolvimento , Filtração/instrumentação , Humanos , Exposição Ocupacional/prevenção & controle , Staphylococcus aureus/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA