Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Xray Sci Technol ; 30(5): 1023-1032, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35848004

RESUMO

OBJECTIVE: To compare dosimetric and radiobiological terms of modified dynamic conformal arc therapy (mDCAT) and volumetric modulated arc therapy (VMAT) techniques using different flattening-filter free (FFF) energies in patients with single adrenal metastasis. METHODS: In this study, plans were prepared for 10 patients drawing on the mDCAT and VMAT techniques with 6MV-FFF and 10MV-FFF energies. Target volume doses, biological effective doses (BED), quality indices, Monitor Unit (MU), number of segments, beam-on time and critical organ doses were compared in the plans. RESULTS: Plans with the significantly lower gradient index (GI) and conformity index (CI) values were obtained with 6MV-FFF energy VMAT planning (p < 0.05). The higher values were obtained for dose to 95% of internal target volume (ITVD95), ITVD95-BED10 with 10MV-FFF energy VMAT planning, whereas lower results were obtained for high dose spillage (HDS%) values (p < 0,05). With 10MV-FFF energy, HDS% values were 21.1% lower in VMAT plans and 5.6% lower in mDCAT plans compared to 6MV-FFF energy. Plans with approximately 50% fewer segments were obtained in mDCAT plans than VMAT plans (p < 0,05). Beam-on time values with mDCAT was 1.84 times lower when 6MV-FFF energies were analyzed, and 2.11 times lower when 10MV-FFF was analyzed (p < 0,05). Additionally, when 6MV-FFF and 10MV-FFF energies were examined, MU values with mDCAT were 2.1 and 2.5 times lower (p < 0,05). In general, the smaller the target volume size, the greater the differences between MU and beam-on time values mDCAT and VMAT. CONCLUSIONS: The study results implied that VMAT enabled to offer significantly more conformal SBRT plans with steeper dose fall-off beyond the target volume for single adrenal metastasis than the mDCAT, which attained at the cost of significantly higher MU and beam-on times. Especially with 10MV-FFF energy mDCAT plans, low-dose-bath zones can be reduced, and shorter-term treatments can be implemented with large segments. In adrenal gland SBRT, higher effective doses can be achieved with the right energy and technique, critical organ doses can be reduced, thus increasing the possibility of local control of the tumor with low toxicity.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pulmonares/patologia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Radiother Oncol ; 129(3): 527-533, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30172456

RESUMO

PURPOSE: To report the feasibility, accuracy, and reliability of volumetric modulated arc therapy (VMAT)-based total-body irradiation (TBI) treatment in patients with acute myeloid leukemia (AML) or acute lymphoblastic leukemia (ALL). MATERIALS AND METHODS: From 2015 to 2018, 30 patients with AML or ALL were planned and treated with VMAT-based TBI, which consisted of three isocenters and three overlapping arcs. TBI dose was prescribed to 90% of the planning treatment volume (PTV) receiving 12 Gy in six fractions, at two fractions per day. Mean lung and kidney doses were restricted less than 10 Gy, and maximum lens dose less than 6 Gy. Quality assurance (QA) comprised the verification of the irradiation plans via dose-volume histogram (DVH) based 3D patient QA system. RESULTS: Average mean lung dose was 9.7 ±â€¯0.2 Gy, mean kidney dose 9.6 ±â€¯0.2 Gy, maximum lens dose 4.5 ±â€¯0.4 Gy, mean PTV dose 12.7 ±â€¯0.1 Gy, and heterogeneity index of PTV was 1.16 ±â€¯0.02 in all patients. Grade 3 or more acute radiation toxicity was not observed. When comparing plan and DVH-based 3D patient QA results, average differences of 3.3% ±â€¯1.3 in mean kidney doses, 1.1% ±â€¯0.7 in mean lung doses, and 0.9% ±â€¯0.4 in mean target doses were observed. CONCLUSION: Linac-based VMAT increased the dose homogeneity of TBI treatment more than extended SSD techniques. Partial cone-beam CT and optical surface-guided system assure patient positioning. DVH-based 3D patient dose verification QA was possible with linac-based VMAT showing small differences between planned and delivered doses. It is feasible, accurate, and reliable.


Assuntos
Leucemia Mieloide Aguda/radioterapia , Leucemia-Linfoma Linfoblástico de Células Precursoras/radioterapia , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total/métodos , Adolescente , Adulto , Criança , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceleradores de Partículas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...