Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Equine Vet Sci ; 136: 105074, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648909

RESUMO

The aim of this study was to evaluate the intraocular pressure (IOP) measurements obtained from first, second, and third probe-cornea touch (PCT) and compare them with the average of six PCTs using two rebound tonometers in horses. This study enrolled a total of thirty-eight stallions, comprising of 24 Arabian horses and 14 cross-breeds (with an average age of 8 ± 3 years). The IOP measurements of first, second, and third, as well as the average of six PCTs were obtained using either Tonovet (TV) or Tonovet Plus (TV+) rebound tonometers. The mean differences (95% limits of agreement) between the average of six PCTs and the first, second, and third PCTs were 0.1 (-4.8 to 5), 0.2 (-4.8 to 4.5), and 0.2 (-3.6 to 4.0) mmHg with TV, respectively. With TV+, the differences were 0.3 (-6.6 to 7.2), 1.1 (-8.6 to 10.8), and -0.2 (-3.6 to 4.0) mmHg, respectively. Compared to the average of six PCTs, only 89.5%, 92.1%, and 97.4% of IOP measurements obtained from TV and 78.9%, 73.3%, and 65.8% of IOP measurements obtained from TV+ were within 4 mmHg of the average of six PCTs for first, second, and third PCTs, respectively. In conclusion, the measurement of IOP in the first PCT achieved best agreement with the IOP measurement of six average PCTs. Therefore, the first PCT could be considered as an alternative option for measuring IOP in horses when obtaining an average of six PCTs is not feasible.


Assuntos
Pressão Intraocular , Tonometria Ocular , Animais , Cavalos/fisiologia , Tonometria Ocular/instrumentação , Tonometria Ocular/veterinária , Tonometria Ocular/métodos , Pressão Intraocular/fisiologia , Masculino
2.
N Z Vet J ; 71(5): 251-258, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37306141

RESUMO

AIMS: To compare intraocular pressure (IOP) measurements obtained in rabbits using rebound (TV) and applanation (TPV) tonometers with four different methods of physical restraint. METHODS: A total of 20 New Zealand White rabbits (40 eyes) were included in this study. IOP readings were obtained from both eyes using the two different tonometers. The rabbits were placed on a table and restrained by wrapping in a cloth (Method I), by scruffing with rear support (Method II), by wrapping in a cloth and cupped in the hands (Method III), or by a box restrainer (Method IV). RESULTS: The mean IOP measurement obtained by TPV was higher than that obtained with the TV for all handling methods. Mean differences (TV-TPV, in mmHg) in IOP were -5.3 (95% Cl = -6.5 to -4.1) for Method 1, -4.7 (95% Cl = -6.2 to -3.29) for Method II, -4.9 (95% Cl = -6.2 to -3.7) for Method III and -7.6 (95% Cl = -9.2 to -5.9) for Method IV. Using the TV tonometer, mean IOP for Method IV was higher than for Method I (mean difference 2.1 (95% Cl = 1.1-3.1)), whereas using the TPV tonometer, mean IOP for Method IV was significantly higher than Method I, II, and III (mean differences: 4.4 (95% Cl = 2.6-5.9), 3.7 (95% Cl = 2-5.3) and 3.8 (95% Cl = 2-5.4), respectively). According to Bland-Altman plots, IOP readings for TPV tended to be higher than those for TV with all handling methods, but with a lack of agreement. The mean difference and 95% limits of agreement for the differences between TV and TPV were -5.4 mmHg (-12.5-1.9 mmHg), -4.7 mmHg (-12.9-3.5 mmHg), -4.9 mmHg (-12-2.2 mmHg), and -7.5 mmHg (-17.4-2.3 mmHg), with Methods I, II, III, and IV, respectively. Comparing TV and TPV, only 7.5%, 12.5%, 27.5%, and 15% of IOP measurements from 20 rabbits were within the range considered clinically acceptable for IOP (± 2 mmHg) for Method I, II, III, and IV, respectively. CONCLUSION AND CLINICAL RELEVANCE: In conclusion, the physical restraint method should be recorded when IOP is measured in rabbits, and TV and TPV tonometers cannot be used interchangeably (high bias and low proportion of measurements within ± 2 mmHg).


Assuntos
Pressão Intraocular , Tonometria Ocular , Animais , Coelhos , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos , Tonometria Ocular/veterinária , Restrição Física , Masculino , Feminino
3.
N Z Vet J ; 70(3): 159-164, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34890521

RESUMO

AIMS: To compare alternative methods of recording body temperature (BT) with rectal temperature (RT) in clinically healthy dogs. METHODS: This prospective study included 97 healthy mixed-breed dogs (43 females and 54 males). The gingival temperature (GT) was collected by using a human non-contact, infrared forehead thermometer, while ocular temperature (OT) and metacarpal pad temperature (MPT) were obtained with an infrared thermal camera. The degree of agreement was determined using the Bland-Altman method, with RT considered as the reference temperature. RESULTS: A total of 382 readings were obtained from four different anatomical regions. The mean difference and their 95% limits of agreement for the differences between RT-GT, RT-OT, and RT-MPT were 0.18°C (-0.95°C-1.32°C), 0.79°C (-0.45°C-2.04°C), and 0.50°C (-0.63°C-1.62°C), respectively. The GT, OT, and MPT values were within ±0.5°C of RT for 65.9%, 19.5%, and 52.5% of dogs, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Although GT, OT, and MPT were a quick way to estimate BT in dogs, these measurements were not comparable with RT. The GT measurement achieved the best agreement with RT measurement (lowest bias and the highest proportion of measurements within ±0.5°C). The GT could be considered an option for monitoring changes to body temperature in clinically healthy dogs where RT measurement is not possible.


Assuntos
Temperatura Corporal , Termômetros , Animais , Cães , Feminino , Masculino , Estudos Prospectivos , Reto , Temperatura , Termômetros/veterinária
4.
Osteoporos Int ; 30(5): 1025-1031, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30701344

RESUMO

Mortality and remaining bedridden following the hip fracture surgery are not rare. We tried to measure the levels of inflammatory markers tumor necrosis factor-alpha (TNF-α) and interleukin-6 (IL-6) following the hip fracture surgery and compare their levels with controls. We aimed to show a relationship between the levels of these markers and post-operative mortality and walking capability. INTRODUCTION: Osteoporosis is a condition, causing the hip fractures in the elderly. Hip fractures have a high rate of overall mortality up to 30% following the incident. Cytokines such as IL-6 and TNF-α are suggested to play a role in bone resorption and, thus, in the etiology of osteoporosis. METHODS: Plasma levels of IL-6 and TNF-α were measured pre-operatively and on the first and second days after the surgery in 40 Turkish hip fracture patients. The levels of these cytokines were compared with 40 Turkish age-matched healthy controls. The levels of these cytokines were compared between the deceased and surviving patients, as well as the existence of walking capability following the surgery. RESULTS: Significantly higher IL-6 levels were shown on the first and second days after the surgery (p = 0.005; p = 0.01, respectively). The overall death rate of our study group within the 2-year follow-up time was found to be 35%. No statistical significance was found in the means of 2-year follow-up mortality between the patients. Presence of walking capability did not differ between the patients, as well. CONCLUSION: We demonstrated an association between IL-6 levels and hip fracture in our study group following the surgery. We also suggest that TNF-α and IL-6 levels are not related to the occurrence of death and walking capability after the surgery. However, these findings need further functional and clinical confirmation.


Assuntos
Fraturas do Quadril/imunologia , Mediadores da Inflamação/metabolismo , Interleucina-6/sangue , Fraturas por Osteoporose/imunologia , Fator de Necrose Tumoral alfa/sangue , Idoso , Biomarcadores/sangue , Estudos de Casos e Controles , Feminino , Seguimentos , Fraturas do Quadril/mortalidade , Fraturas do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/mortalidade , Fraturas por Osteoporose/cirurgia , Período Pós-Operatório , Período Pré-Operatório , Prognóstico , Turquia/epidemiologia , Caminhada
5.
Artigo em Inglês | MEDLINE | ID: mdl-26186392

RESUMO

A complete structural and vibrational analysis of the 4-(2,5-di-2-thienyl-1H-pyrrol-1-yl) benzoic acid (TPBA), was carried out by ab initio calculations, at the density functional theory (DFT) method. Molecular geometry, vibrational wavenumbers and gauge including atomic orbital (GIAO) (13)C NMR and (1)H NMR chemical shift values of (TPBA), in the ground state have been calculated by using ab initio density functional theory (DFT/B3LYP) method with 6-311G(d,p) as basis set for the first time. Comparison of the observed fundamental vibrational modes of (TPBA) and calculated results by DFT/B3LYP method indicates that B3LYP level of theory giving yield good results for quantum chemical studies. Vibrational wavenumbers obtained by the DFT/B3LYP method are in good agreement with the experimental data. The study was complemented with a natural bond orbital (NBO) analysis, to evaluate the significance of hyperconjugative interactions and electrostatic effects on such molecular structure. By using TD-DFT method, electronic absorption spectra of the title compound have been predicted and a good agreement with the TD-DFT method and the experimental one is determined. In addition, the molecular electrostatic potential (MEP), frontier molecular orbitals analysis and thermodynamic properties of TPBA were investigated using theoretical calculations.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 133: 307-17, 2014 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-24954755

RESUMO

The molecular structure and vibrations of 5-[(3-methylphenyl) (phenyl) amino] isophthalic acid (MePIFA) were investigated by infrared and Raman spectroscopies, UV-Vis, (1)H and (13)C NMR spectroscopic techniques and NBO analysis. FT-IR, FT-Raman and dispersive Raman spectra were recorded in the solid phase. (1)H and (13)C NMR spectra and UV-Vis spectrum were recorded in DMSO solution. HOMO-LUMO analysis and molecular electrostatic potential (MEP) analysis were performed. The theoretical calculations for the molecular structure and spectroscopies were performed with DFT (B3LYP) and 6-311G(d,p) basis set calculations using the Gaussian 09 program. After the geometry of the molecule was optimized, vibration wavenumbers and fundamental vibration wavenumbers were assigned on the basis of the potential energy distribution (PED) of the vibrational modes calculated with VEDA 4 program. The total (TDOS), partial (PDOS) density of state and overlap population density of state (OPDOS) diagrams analysis were made using GaussSum 2.2 program. The results of theoretical calculations for the spectra of the title compound were compared with the observed spectra.


Assuntos
Ácidos Ftálicos/química , Luz , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Conformação Molecular , Teoria Quântica , Espectrofotometria Ultravioleta , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman
7.
Artigo em Inglês | MEDLINE | ID: mdl-22522295

RESUMO

The solid phase FT-IR, FT-Raman and dispersive Raman spectra of the host molecule which potential applications in sensor devices have been recorded in the region 400-4000 and 50-3500cm(-1), respectively. The spectra were interpreted in terms of fundamentals modes, combination and overtone bands. The structure of the molecule was optimized and the structural characteristics were determined by density functional theory (DFT) using B3LYP method with 6-31G(d) basis set. The vibrational frequencies were calculated for the studied molecule by DFT method, and compared with the experimental frequencies, which yield good agreement between observed and calculated frequencies. Finally the calculation results were applied to simulate infrared and Raman spectra of the compound. Obtained these spectra also showed good agreement with observed spectra. The dipole moment, linear polarizability and first hyperpolarizability values were also computed. The linear polarizability and first hyperpolarizability of the studied molecule indicate that the compound is a good candidate of nonlinear optical materials.


Assuntos
Técnicas Biossensoriais/instrumentação , Calixarenos/química , Calixarenos/síntese química , Análise Espectral Raman , Anisotropia , Espectroscopia de Ressonância Magnética , Conformação Molecular , Espectroscopia de Infravermelho com Transformada de Fourier , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA