Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Crystallogr ; 55(Pt 4): 911-918, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35974730

RESUMO

In situ investigations of cracks propagating at up to 2.5 km s-1 along an (001) plane of a silicon single crystal are reported, using X-ray diffraction megahertz imaging with intense and time-structured synchrotron radiation. The studied system is based on the Smart Cut process, where a buried layer in a material (typically Si) is weakened by microcracks and then used to drive a macroscopic crack (10-1 m) in a plane parallel to the surface with minimal deviation (10-9 m). A direct confirmation that the shape of the crack front is not affected by the distribution of the microcracks is provided. Instantaneous crack velocities over the centimetre-wide field of view were measured and showed an effect of local heating by the X-ray beam. The post-crack movements of the separated wafer parts could also be observed and explained using pneumatics and elasticity. A comprehensive view of controlled fracture propagation in a crystalline material is provided, paving the way for the in situ measurement of ultra-fast strain field propagation.

3.
Front Neurosci ; 14: 584161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33240038

RESUMO

We report a qualitative study on central nervous system (CNS) damage that demonstrates the ability of X-ray phase contrast tomography (XPCT) to confirm data obtained with standard 2D methodology and permits the description of additional features that are not detected with 2D or other 3D techniques. In contrast to magnetic resonance or computed tomography, XPCT makes possible the high-resolution 3D imaging of soft tissues classically considered "invisible" to X-rays without the use of additional contrast agents, or without the need for intense processing of the tissue required by 2D techniques. Most importantly for studies of CNS diseases, XPCT enables a concomitant multi-scale 3D biomedical imaging of neuronal and vascular networks ranging from cells through to the CNS as a whole. In the last years, we have used XPCT to investigate neurodegenerative diseases, such as Alzheimer's disease (AD) and multiple sclerosis (MS), to shed light on brain damage and extend the observations obtained with standard techniques. Here, we show the cutting-edge ability of XPCT to highlight in 3D, concomitantly, vascular occlusions and damages, close associations between plaques and damaged vessels, as well as dramatic changes induced at neuropathological level by treatment in AD mice. We corroborate data on the well-known blood-brain barrier dysfunction in the animal model of MS, experimental autoimmune encephalomyelitis, and further show its extent throughout the CNS axis and at the level of the single vessel/capillary.

4.
Sci Rep ; 10(1): 9353, 2020 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-32493928

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

5.
Sci Rep ; 10(1): 3389, 2020 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-32098995

RESUMO

Laser welding is a key technology for many industrial applications. However, its online quality monitoring is an open issue due to the highly complex nature of the process. This work aims at enriching existing approaches in this field. We propose a method for real-time detection of process instabilities that can lead to defects. Hard X-ray radiography is used for the ground truth observations of the sub-surface events that are critical for the quality. A deep artificial neural network is applied to reveal the unique signatures of those events in wavelet spectrograms from the laser back-reflection and acoustic emission signals. The autonomous classification of the revealed signatures is tested on real-life data, while the real-time performance is reached by means of parallel computing. The confidence of the quality classification ranges between 71% and 99%, with a temporal resolution down to 2 ms and a computation time per classification task as low as 2 ms. This approach is a new paradigm in the digitization of industrial processes and can be exploited to provide feedbacks in a closed-loop quality control system.

6.
Langmuir ; 35(8): 3038-3047, 2019 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-30646687

RESUMO

Laser ablation of gold in liquids with nanosecond laser pulses in aqueous solutions of inorganic electrolytes and macromolecular ligands for gold nanoparticle size quenching is probed inside the laser-induced cavitation bubble by in situ X-ray multicontrast imaging with a Hartmann mask (XHI). It is found that (i) the in situ size quenching power of sodium chloride (NaCl) in comparison to the ablation in pure water can be observed by the scattering contrast from XHI already inside the cavitation bubble, while (ii) for polyvinylpyrrolidone (PVP) as a macromolecular model ligand an in situ size quenching cannot be observed. Complementary ex situ characterization confirms the overall size quenching ability of both additive types NaCl and PVP. The macromolecular ligand as well as its monomer N-vinylpyrrolidone (NVP) are mainly effective for growth quenching of larger nanoparticles on later time scales, leading to the conclusion of an alternative interaction mechanism with ablated nanoparticles compared to the electrolyte NaCl, probably outside of the cavitation bubble, in the surrounding liquid phase. While monomer and polymer have similar effects on the particle properties, with the polymer being slightly more efficient, only the polymer is effective against hydrodynamic aggregation.

7.
Appl Opt ; 57(18): 5004-5010, 2018 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-30117959

RESUMO

A new generation of cameras has made ultra-high-speed x-ray imaging at synchrotron light sources a reality, revealing never-before-seen details of sub-surface transient phenomena. We introduce a versatile indirect imaging system capable of capturing-for the first time-hundreds of sequential x-ray pulses in 16-bunch mode at the European Synchrotron Radiation Facility, recording at 5.68 Mfps over dozens of microseconds, with an effective exposure of 100 ps. The versatile multiplex camera construction of the system allows for various arrangements, including different scintillator configurations, and simultaneous imaging with different resolutions and regions of interest. Image results from a gas gun impact experiment, in which an additive manufactured aluminum lattice was dynamically compressed, is presented as a demonstration of the system's capabilities.

8.
IUCrJ ; 5(Pt 4): 428-438, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30002844

RESUMO

An experimental procedure for transmission X-ray ghost imaging using synchrotron light is presented. Hard X-rays from an undulator were divided by a beamsplitter to produce two copies of a speckled incident beam. Both beams were simultaneously measured on an indirect pixellated detector and the intensity correlation between the two copies was used to retrieve the ghost image of samples placed in one of the two beams, without measuring the samples directly. Aiming at future practical uses of X-ray ghost imaging, the authors discuss details regarding data acquisition, image reconstruction strategies and measure the point-spread function of the ghost-imaging system. This approach may become relevant for applications of ghost imaging with X-ray sources such as undulators in storage rings, free-electron lasers and lower-coherence laboratory facilities.

9.
Opt Express ; 25(12): 13857-13871, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28788829

RESUMO

Third generation synchrotron light sources offer high photon flux, partial spatial coherence, and ~10-10 s pulse widths. These enable hard X-ray phase-contrast imaging (XPCI) with single-bunch temporal resolutions. In this work, we exploited the MHz repetition rates of synchrotron X-ray pulses combined with indirect X-ray detection to demonstrate the potential of XPCI with millions of frames per second multiple-frame recording. This allows for the visualization of aperiodic or stochastic transient processes which are impossible to be realized using single-shot or stroboscopic XPCI. We present observations of various phenomena, such as crack tip propagation in glass, shock wave propagation in water and explosion during electric arc ignition, which evolve in the order of km/s (µm/ns).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...