Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36850763

RESUMO

Deep Learning models have presented promising results when applied to Agriculture 4.0. Among other applications, these models can be used in disease detection and fruit counting. Deep Learning models usually have many layers in the architecture and millions of parameters. This aspect hinders the use of Deep Learning on mobile devices as they require a large amount of processing power for inference. In addition, the lack of high-quality Internet connectivity in the field impedes the usage of cloud computing, pushing the processing towards edge devices. This work describes the proposal of an edge AI application to detect and map diseases in citrus orchards. The proposed system has low computational demand, enabling the use of low-footprint models for both detection and classification tasks. We initially compared AI algorithms to detect fruits on trees. Specifically, we analyzed and compared YOLO and Faster R-CNN. Then, we studied lean AI models to perform the classification task. In this context, we tested and compared the performance of MobileNetV2, EfficientNetV2-B0, and NASNet-Mobile. In the detection task, YOLO and Faster R-CNN had similar AI performance metrics, but YOLO was significantly faster. In the image classification task, MobileNetMobileV2 and EfficientNetV2-B0 obtained an accuracy of 100%, while NASNet-Mobile had a 98% performance. As for the timing performance, MobileNetV2 and EfficientNetV2-B0 were the best candidates, while NASNet-Mobile was significantly worse. Furthermore, MobileNetV2 had a 10% better performance than EfficientNetV2-B0. Finally, we provide a method to evaluate the results from these algorithms towards describing the disease spread using statistical parametric models and a genetic algorithm to perform the parameters' regression. With these results, we validated the proposed pipeline, enabling the usage of adequate AI models to develop a mobile edge AI solution.


Assuntos
Agricultura , Citrus , Algoritmos , Benchmarking , Inteligência Artificial
2.
Ecology ; 104(2): e3923, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36428233

RESUMO

Plant recruitment interactions (i.e., what recruits under what) shape the composition, diversity, and structure of plant communities. Despite the huge body of knowledge on the mechanisms underlying recruitment interactions among species, we still know little about the structure of the recruitment networks emerging in ecological communities. Modeling and analyzing the community-level structure of plant recruitment interactions as a complex network can provide relevant information on ecological and evolutionary processes acting both at the species and ecosystem levels. We report a data set containing 143 plant recruitment networks in 23 countries across five continents, including temperate and tropical ecosystems. Each network identifies the species under which another species recruits. All networks report the number of recruits (i.e., individuals) per species. The data set includes >850,000 recruiting individuals involved in 118,411 paired interactions among 3318 vascular plant species across the globe. The cover of canopy species and open ground is also provided. Three sampling protocols were used: (1) The Recruitment Network (RN) protocol (106 networks) focuses on interactions among established plants ("canopy species") and plants in their early stages of recruitment ("recruit species"). A series of plots was delimited within a locality, and all the individuals recruiting and their canopy species were identified; (2) The paired Canopy-Open (pCO) protocol (26 networks) consists in locating a potential canopy plant and identifying recruiting individuals under the canopy and in a nearby open space of the same area; (3) The Georeferenced plot (GP) protocol (11 networks) consists in using information from georeferenced individual plants in large plots to infer canopy-recruit interactions. Some networks incorporate data for both herbs and woody species, whereas others focus exclusively on woody species. The location of each study site, geographical coordinates, country, locality, responsible author, sampling dates, sampling method, and life habits of both canopy and recruit species are provided. This database will allow researchers to test ecological, biogeographical, and evolutionary hypotheses related to plant recruitment interactions. There are no copyright restrictions on the data set; please cite this data paper when using these data in publications.


Assuntos
Ecossistema , Traqueófitas , Humanos , Plantas , Evolução Biológica
3.
Artigo em Inglês | MEDLINE | ID: mdl-35311272

RESUMO

Impedimetric wearable sensors are a promising strategy for determining the loss of water content (LWC) from leaves because they can afford on-site and nondestructive quantification of cellular water from a single measurement. Because the water content is a key marker of leaf health, monitoring of the LWC can lend key insights into daily practice in precision agriculture, toxicity studies, and the development of agricultural inputs. Ongoing challenges with this monitoring are the on-leaf adhesion, compatibility, scalability, and reproducibility of the electrodes, especially when subjected to long-term measurements. This paper introduces a set of sensing material, technological, and data processing solutions that overwhelm such obstacles. Mass-production-suitable electrodes consisting of stand-alone Ni films obtained by well-established microfabrication methods or ecofriendly pyrolyzed paper enabled reproducible determination of the LWC from soy leaves with optimized sensibilities of 27.0 (Ni) and 17.5 kΩ %-1 (paper). The freestanding design of the Ni electrodes was further key to delivering high on-leaf adhesion and long-term compatibility. Their impedances remained unchanged under the action of wind at velocities of up to 2.00 m s-1, whereas X-ray nanoprobe fluorescence assays allowed us to confirm the Ni sensor compatibility by the monitoring of the soy leaf health in an electrode-exposed area. Both electrodes operated through direct transfer of the conductive materials on hairy soy leaves using an ordinary adhesive tape. We used a hand-held and low-power potentiostat with wireless connection to a smartphone to determine the LWC over 24 h. Impressively, a machine-learning model was able to convert the sensing responses into a simple mathematical equation that gauged the impairments on the water content at two temperatures (30 and 20 °C) with reduced root-mean-square errors (0.1% up to 0.3%). These data suggest broad applicability of the platform by enabling direct determination of the LWC from leaves even at variable temperatures. Overall, our findings may help to pave the way for translating "sense-act" technologies into practice toward the on-site and remote investigation of plant drought stress. These platforms can provide key information for aiding efficient data-driven management and guiding decision-making steps.

4.
Sci Rep ; 11(1): 23671, 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34880305

RESUMO

Shedding synchrotron light on microfluidic systems, exploring several contrasts in situ/operando at the nanoscale, like X-ray fluorescence, diffraction, luminescence, and absorption, has the potential to reveal new properties and functionalities of materials across diverse areas, such as green energy, photonics, and nanomedicine. In this work, we present the micro-fabrication and characterization of a multifunctional polyester/glass sealed microfluidic device well-suited to combine with analytical X-ray techniques. The device consists of smooth microchannels patterned on glass, where three gold electrodes are deposited into the channels to serve in situ electrochemistry analysis or standard electrical measurements. It has been efficiently sealed through an ultraviolet-sensitive sticker-like layer based on a polyester film, and The burst pressure determined by pumping water through the microchannel(up to 0.22 MPa). Overall, the device has demonstrated exquisite chemical resistance to organic solvents, and its efficiency in the presence of biological samples (proteins) is remarkable. The device potentialities, and its high transparency to X-rays, have been demonstrated by taking advantage of the X-ray nanoprobe Carnaúba/Sirius/LNLS, by obtaining 2D X-ray nanofluorescence maps on the microchannel filled with water and after an electrochemical nucleation reaction. To wrap up, the microfluidic device characterized here has the potential to be employed in standard laboratory experiments as well as in in situ and in vivo analytical experiments using a wide electromagnetic window, from infrared to X-rays, which could serve experiments in many branches of science.

5.
Sensors (Basel) ; 21(15)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34372319

RESUMO

Ecological environments research helps to assess the impacts on forests and managing forests. The usage of novel software and hardware technologies enforces the solution of tasks related to this problem. In addition, the lack of connectivity for large data throughput raises the demand for edge-computing-based solutions towards this goal. Therefore, in this work, we evaluate the opportunity of using a Wearable edge AI concept in a forest environment. For this matter, we propose a new approach to the hardware/software co-design process. We also address the possibility of creating wearable edge AI, where the wireless personal and body area networks are platforms for building applications using edge AI. Finally, we evaluate a case study to test the possibility of performing an edge AI task in a wearable-based environment. Thus, in this work, we evaluate the system to achieve the desired task, the hardware resource and performance, and the network latency associated with each part of the process. Through this work, we validated both the design pattern review and case study. In the case study, the developed algorithms could classify diseased leaves with a circa 90% accuracy with the proposed technique in the field. This results can be reviewed in the laboratory with more modern models that reached up to 96% global accuracy. The system could also perform the desired tasks with a quality factor of 0.95, considering the usage of three devices. Finally, it detected a disease epicenter with an offset of circa 0.5 m in a 6 m × 6 m × 12 m space. These results enforce the usage of the proposed methods in the targeted environment and the proposed changes in the co-design pattern.


Assuntos
Algoritmos , Dispositivos Eletrônicos Vestíveis , Inteligência Artificial , Desenho de Equipamento , Humanos , Software
6.
ACS Sens ; 5(7): 1864-1871, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32597643

RESUMO

Extracellular vesicles (EVs) are a frontier class of circulating biomarkers for the diagnosis and prognosis of different diseases. These lipid structures afford various biomarkers such as the concentrations of the EVs (CV) themselves and carried proteins (CP). However, simple, high-throughput, and accurate determination of these targets remains a key challenge. Herein, we address the simultaneous monitoring of CV and CP from a single impedance spectrum without using recognizing elements by combining a multidimensional sensor and machine learning models. This multidetermination is essential for diagnostic accuracy because of the heterogeneous composition of EVs and their molecular cargoes both within the tumor itself and among patients. Pencil HB cores acting as electric double-layer capacitors were integrated into a scalable microfluidic device, whereas supervised models provided accurate predictions, even from a small number of training samples. User-friendly measurements were performed with sample-to-answer data processing on a smartphone. This new platform further showed the highest throughput when compared with the techniques described in the literature to quantify EVs biomarkers. Our results shed light on a method with the ability to determine multiple EVs biomarkers in a simple and fast way, providing a promising platform to translate biofluid-based diagnostics into clinical workflows.


Assuntos
Vesículas Extracelulares , Dispositivos Lab-On-A-Chip , Aprendizado de Máquina , Neoplasias , Biomarcadores , Humanos
7.
Sensors (Basel) ; 20(8)2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32326651

RESUMO

Frequent and accurate inspections of industrial components and equipment are essential because failures can cause unscheduled downtimes, massive material, and financial losses or even endanger workers. In the mining industry, belt idlers or rollers are examples of such critical components. Although there are many precise laboratory techniques to assess the condition of a roller, companies still have trouble implementing a reliable and scalable procedure to inspect their field assets. This article enumerates and discusses the existing roller inspection techniques and presents a novel approach based on an Unmanned Aerial Vehicle (UAV) integrated with a thermal imaging camera. Our preliminary results indicate that using a signal processing technique, we are able to identify roller failures automatically. We also proposed and implemented a back-end platform that enables field and cloud connectivity with enterprise systems. Finally, we have also cataloged the anomalies detected during the extensive field tests in order to build a structured dataset that will allow for future experimentation.

8.
Sensors (Basel) ; 19(20)2019 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-31614802

RESUMO

The widespread availability of wearable devices is evolving them into cooperative systems. Communication and distribution aspects such as the Internet of Things, Wireless Body Area Networks, and Local Wireless Networks provide the means to develop multi-device platforms. Nevertheless, the field research environment presents a specific feature set, which increases the difficulty in the adoption of this technology. In this text, we review the main aspects of Field Research Gears and Wearable Devices. This review is made aiming to understand how to create cooperative systems based on wearable devices directed to the Field Research Context. For a better understanding, we developed a case study in which we propose a cooperative system architecture and provide validation aspects. For this matter, we provide an overview of a previous device architecture and study an integration proposal.


Assuntos
Dispositivos Eletrônicos Vestíveis , Redes de Comunicação de Computadores , Humanos , Reprodutibilidade dos Testes , Software , Tecnologia sem Fio
9.
Sensors (Basel) ; 19(14)2019 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-31336711

RESUMO

This paper proposes the use of the Statistical Process Control (SPC), more specifically, the Exponentially Weighted Moving Average method, for the monitoring of drivers using approaches based on the vehicle and the driver's behavior. Based on the SPC, we propose a method for the lane departure detection; a method for detecting sudden driver movements; and a method combined with computer vision to detect driver fatigue. All methods consider information from sensors scattered by the vehicle. The results showed the efficiency of the methods in the identification and detection of unwanted driver actions, such as sudden movements, lane departure, and driver fatigue. Lane departure detection obtained results of up to 76.92% (without constant speed) and 84.16% (speed maintained at ≈60). Furthermore, sudden movements detection obtained results of up to 91.66% (steering wheel) and 94.44% (brake). The driver fatigue has been detected in up to 94.46% situations.

10.
Chembiochem ; 20(18): 2390-2401, 2019 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-31026110

RESUMO

Class 1 myosins (Myo1s) were the first unconventional myosins identified and humans have eight known Myo1 isoforms. The Myo1 family is involved in the regulation of gene expression, cytoskeletal rearrangements, delivery of proteins to the cell surface, cell migration and spreading. Thus, the important role of Myo1s in different biological processes is evident. In this study, we have investigated the effects of pentachloropseudilin (PClP), a reversible and allosteric potent inhibitor of Myo1s, on angiogenesis. We demonstrated that treatment of cells with PClP promoted a decrease in the number of vessels. The observed inhibition of angiogenesis is likely to be related to the inhibition of cell proliferation, migration and adhesion, as well as to alteration of the actin cytoskeleton pattern, as shown on a PClP-treated HUVEC cell line. Moreover, we also demonstrated that PClP treatment partially prevented the delivery of integrins to the plasma membrane. Finally, we showed that PClP caused DNA strand breaks, which are probably repaired during the cell cycle arrest in the G1 phase. Taken together, our results suggest that Myo1s participate directly in the angiogenesis process.


Assuntos
Citoesqueleto de Actina/efeitos dos fármacos , Inibidores da Angiogênese/farmacologia , Ciclo Celular/efeitos dos fármacos , Hidrocarbonetos Clorados/farmacologia , Integrinas/metabolismo , Pirróis/farmacologia , Inibidores da Angiogênese/toxicidade , Adesão Celular/efeitos dos fármacos , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Pontos de Checagem da Fase G1 do Ciclo Celular/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana , Humanos , Hidrocarbonetos Clorados/toxicidade , Integrinas/genética , Miosina Tipo I/metabolismo , Pirróis/toxicidade , RNA Mensageiro/metabolismo
11.
Chembiochem, v. 20, n. 18, p. 2390-2401, set. 2020
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-3196

RESUMO

Class 1 myosins (Myo1s) were the first unconventional myosins identified and humans have eight known Myo1 isoforms. The Myo1 family is involved in the regulation of gene expression, cytoskeletal rearrangements, delivery of proteins to the cell surface, cell migration and spreading. Thus, the important role of Myo1s in different biological processes is evident. In this study, we have investigated the effects of pentachloropseudilin (PClP), a reversible and allosteric potent inhibitor of Myo1s, on angiogenesis. We demonstrated that treatment of cells with PClP promoted a decrease in the number of vessels. The observed inhibition of angiogenesis is likely to be related to the inhibition of cell proliferation, migration and adhesion, as well as to alteration of the actin cytoskeleton pattern, as shown on a PClP‐treated HUVEC cell line. Moreover, we also demonstrated that PClP treatment partially prevented the delivery of integrins to the plasma membrane. Finally, we showed that PClP caused DNA strand breaks, which are probably repaired during the cell cycle arrest in the G1 phase. Taken together, our results suggest that Myo1s participate directly in the angiogenesis process.

12.
Anal Chem ; 90(21): 12377-12384, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30222327

RESUMO

This technical note describes a new microfluidic sensor that combines low-cost (USD $0.97) with rapid fabrication and user-friendly, fast, sensitive, and accurate quantification of a breast cancer biomarker. The electrodes consisted of cost-effective bare stainless-steel capillaries, whose mass production is already well-established. These capillaries were used as received, without any surface modification. Microfluidic chips containing electrical double-layer capillary capacitors (µEDLC) were obtained by a cleanroom-free prototyping that allows the fabrication of dozens to hundreds of chips in 1 h. This sensor provided the successful quantification of CA 15-3, a biomarker protein for breast cancer, in serum samples from cancer patients. Antibody-anchored magnetic beads were utilized for immunocapture of the marker, and then, water was added to dilute the protein. Next, the CA 15-3 detection (<2 min) was made without using redox probes, antibody on electrode (sandwich immunoassay), or signal amplification strategies. In addition, the capacitance tests eliminated external pumping systems and precise volumetric sampling steps, as well as presented low sample volume (5 µL) and high sensitivity using bare capillaries in a new design for double-layer capacitors. The achieved limit-of-detection (92.0 µU mL-1) is lower than that of most methods reported in the literature for CA 15-3, which are based on nanostructured electrodes. The data shown in this technical note support the potential of the µEDLC toward breast cancer diagnosis even at early stages. We believe that accurate analyses using a simple sample pretreatment such as magnetic field-assisted immunocapture and cost-effective bare electrodes can be extended to quantify other cancer biomarkers and even biomolecules by changing the biorecognition element.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/economia , Neoplasias da Mama/diagnóstico por imagem , Técnicas Eletroquímicas/economia , Técnicas Analíticas Microfluídicas/economia , Mucina-1/análise , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Eletrodos , Feminino , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
13.
Sci Rep ; 7(1): 7077, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28765552

RESUMO

Phospholipases A2 (PLA2s) overexpression is closely associated with the malignant potential of breast cancers. Here, we showed for the first the antitumoral effects of γCdcPLI, a PLA2 inhibitor from Crotalus durissus collilineatus via PI3K/Akt pathway on MDA-MB-231 cell. Firstly, γCdcPLI was more cytotoxic to MDA-MB-231 breast cancer cells than other cell lines (MCF-7, HeLa, PC3 and A549) and did not affect the viability of non-tumorigenic breast cell (MCF 10A). In addition, γCdcPLI induced modulation of important mediators of apoptosis pathways such as p53, MAPK-ERK, BIRC5 and MDM2. γCdcPLI decreased MDA-MB-231 adhesion, migration and invasion. Interestingly, the γCdcPLI also inhibited the adhesion and migration of endothelial cells and blocked angiogenesis by inhibiting tube formation by HUVECs in vitro and sprouting elongation on aortic ring assay ex vivo. Furthermore, γCdcPLI reduced the production of vascular endothelial growth factor (VEGF). γCdcPLI was also able to decrease PGE2 levels in MDA-MB-231 and inhibited gene and protein expression of the PI3K/Akt pathway. In conclusion, γCdcPLI showed in vitro antitumoral, antimestatatic and anti-angiogenic potential effects and could be an attractive approach for futures studies in cancer therapy.


Assuntos
Antineoplásicos/farmacologia , Neoplasias da Mama , Lipoproteínas/farmacologia , Proteína Oncogênica v-akt/metabolismo , Fosfatidilinositol 3-Quinase/metabolismo , Inibidores de Fosfolipase A2/farmacologia , Antineoplásicos/isolamento & purificação , Adesão Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Movimento Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Venenos de Crotalídeos/química , Células Endoteliais/efeitos dos fármacos , Humanos , Lipoproteínas/isolamento & purificação , Modelos Biológicos , Neovascularização Patológica , Inibidores de Fosfolipase A2/isolamento & purificação
14.
ACS Appl Mater Interfaces ; 9(33): 27433-27440, 2017 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-28742317

RESUMO

Breast cancer is the most common cancer in women worldwide. The detection of biomarkers has played a significant role in the early diagnosis and prognosis of breast cancer. Herein, we describe the construction of a disposable microfluidic immunoarray device (DµID) for the rapid and low-cost detection of CA15-3 (carbohydrate antigen 15-3), a protein biomarker for breast cancer. The DµID was constructed using a simple and rapid prototyping technique and was applied to detect CA15-3 in cancer patients. The DµID construction was based on the use of a double-sided adhesive card with a microfluidic channel and a screen-printed array with 8 electrodes. Both the immunoarray and microfluidic channel were designed using an inexpensive home cutter printer and using low-cost materials. The immunoarray was modified using the layer-by-layer technique aiming at immobilizing the primary antibody. For the biomarker detection, magnetic particles (MPs) modified with polyclonal antibodies and peroxidase enzymes were used as a strategy for capture, separation, and preconcentration of the biomarker, in addition to amplification of the electroanalytical signal. The preconcentration and amplification strategies integrated with the nanostructured immunosensors of the DµID meaningfully contributed toward the detection of CA15-3 with a limit of detection (LoD) of 6 µU mL-1, requiring as low as 2 µL of serum samples for 8 simultaneous detections. The obtained LoD was 1200 times lower compared to those of other immunosensors previously reported in the literature. The DµID was applied for the detection of CA15-3 in real samples of breast cancer patients and was found to present an excellent correlation with the well-established commercial electrochemiluminescence immunoassay. The association of the DµID with nanostructured surfaces and analyte capturing with bioconjugated paramagnetic particles is essentially a promising breakthrough for the low-cost and accurate detection of cancer biomarkers.


Assuntos
Microfluídica , Biomarcadores Tumorais , Técnicas Biossensoriais , Humanos , Imunoensaio , Dispositivos Lab-On-A-Chip , Limite de Detecção
15.
Anal Chim Acta ; 957: 40-46, 2017 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-28107832

RESUMO

This paper describes the fabrication of 2D and 3D microfluidic paper-based analytical devices (µPADs) for monitoring glucose, total protein, and nitrite in blood serum and artificial urine. A new method of cutting and sealing filter paper to construct µPADs was demonstrated. Using an inexpensive home cutter printer soft cellulose-based filter paper was easily and precisely cut to produce pattern hydrophilic microchannels. 2D and 3D µPADs were designed with three detection zones each for the colorimetric detection of the analytes. A small volume of samples was added to the µPADs, which was photographed after 15 min using a digital camera. Both µPADs presented an excellent analytical performance for all analytes. The 2D device was applied in artificial urine samples and reached limits of detection (LODs) of 0.54 mM, 5.19 µM, and 2.34 µM for glucose, protein, and nitrite, respectively. The corresponding LODs of the 3D device applied for detecting the same analytes in artificial blood serum were 0.44 mM, 1.26 µM, and 4.35 µM.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Papel , Glucose/análise , Humanos , Interações Hidrofóbicas e Hidrofílicas , Nitritos/análise , Proteínas/análise , Urina/química
16.
Sci. Rep. ; 7(7077)2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: but-ib15099

RESUMO

Phospholipases A(2) (PLA(2)s) overexpression is closely associated with the malignant potential of breast cancers. Here, we showed for the first the antitumoral effects of gamma CdcPLI, a PLA2 inhibitor from Crotalus durissus collilineatus via PI3K/Akt pathway on MDA-MB-231 cell. Firstly, gamma CdcPLI was more cytotoxic to MDA-MB-231 breast cancer cells than other cell lines ( MCF-7, HeLa, PC3 and A549) and did not affect the viability of non-tumorigenic breast cell (MCF 10A). In addition, gamma CdcPLI induced modulation of important mediators of apoptosis pathways such as p53, MAPK-ERK, BIRC5 and MDM2.gamma CdcPLI decreased MDA-MB-231 adhesion, migration and invasion. Interestingly, the gamma CdcPLI also inhibited the adhesion and migration of endothelial cells and blocked angiogenesis by inhibiting tube formation by HUVECs in vitro and sprouting elongation on aortic ring assay ex vivo. Furthermore,gamma CdcPLI reduced the production of vascular endothelial growth factor (VEGF).gamma CdcPLI was also able to decrease PGE2 levels in MDA-MB-231 and inhibited gene and protein expression of the PI3K/Akt pathway. In conclusion,gamma CdcPLI showed in vitro antitumoral, antimestatatic and anti-angiogenic potential effects and could be an attractive approach for futures studies in cancer therapy.

17.
J Stroke Cerebrovasc Dis ; 22(8): e658-60, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23830958

RESUMO

Alteplase (recombinant tissue plasminogen activator [rt-PA]) label approval by the Food and Drug Administration remarks the contraindication of its use with known intracranial neoplasm because of potential bleeding complications. Despite this concern, the real risk of intracerebral bleeding in patients with intracranial neoplasms treated with rt-PA is unknown, and there are few reports of thrombolysis in patients with brain tumors. We report a case of a 78-year-old man who was seen in our emergency department within 2 hours from sudden onset of aphasia, right-sided hemiplegia, hypoesthesia, and homonymous hemianopsia. The National Institutes of Health Stroke Scale (NIHSS) score at admission was 20. Intra-arterial thrombolysis was performed with administration of .3 mg/kg of alteplase combined with mechanical thrombectomy. At discharge, his NIHSS score was 1, and after 90 days, his modified Rankin score was 1. To our knowledge, this is the first report of intra-arterial thrombolysis in a patient with acute ischemic stroke with an intracranial tumor.


Assuntos
Fibrinolíticos/administração & dosagem , Infarto da Artéria Cerebral Média/tratamento farmacológico , Neoplasias Meníngeas/complicações , Meningioma/complicações , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/administração & dosagem , Idoso , Angiografia Cerebral/métodos , Avaliação da Deficiência , Humanos , Infarto da Artéria Cerebral Média/complicações , Infarto da Artéria Cerebral Média/diagnóstico , Masculino , Neoplasias Meníngeas/diagnóstico , Meningioma/diagnóstico , Índice de Gravidade de Doença , Trombectomia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Neurochem Res ; 34(6): 1066-75, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19005754

RESUMO

In the present work, we showed that a chalcone-enriched fraction (CEF) isolated from the stem bark of a Brazilian medicinal plant, Myracrodruon urundeuva, presents neuroprotective actions on 6-hydroxydopamine (6-OHDA)-induced neuronal cell death, in rat mesencephalic cells. In the MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium] assay, which is an index of cell viability, CEF (1-100 microg/ml) reversed in a concentration-dependent manner the 6-OHDA-induced cell death. While cells exposed to 6-OHDA (40 microM) showed an increased concentration of thiobarbituric acid reactive substances (TBARS), the pretreatment with CEF (10-100 microg/ml) significantly decreased the 6-OHDA-induced TBARS formation, indicative of a neuroprotection against lipoperoxidation. Furthermore, the drastic increase of nitrite levels induced by 6-OHDA, indicative of nitric oxide formation and free radicals production, was prevented by CEF. Double staining with acridine orange/ethidium bromide showed that cultures exposed to 6-OHDA (40 and 200 microM) presented an increase of apoptotic and necrotic cell numbers in a concentration-dependent manner. CEF (100 microg/ml) protected cells from apoptosis and necrosis and increased number of cells presenting a normal morphology. The immunohistochemical analysis for tyrosine hydroxylase (TH) positive neurons indicated that 6-OHDA (40 and 200 microM) caused a concentration-dependent loss of TH+ and TH- neurons. CEF protected both cells types from 6-OHDA-induced cell death. All together, our results demonstrated neuroprotective effects of chalcones, which are able to reduce oxidative stress and apoptotic injury caused by 6-OHDA. Our findings suggest that chalcones could provide benefits, along with other therapies, in neurodegenerative injuries, such as Parkinson's disease.


Assuntos
Anacardiaceae , Chalconas/farmacologia , Citotoxinas/toxicidade , Mesencéfalo/citologia , Neurônios/efeitos dos fármacos , Fármacos Neuroprotetores/farmacologia , Oxidopamina/toxicidade , Animais , Morte Celular/efeitos dos fármacos , Células Cultivadas , Dopamina/metabolismo , Imuno-Histoquímica , Peroxidação de Lipídeos/efeitos dos fármacos , Neurônios/citologia , Neurônios/metabolismo , Nitritos/metabolismo , Estresse Oxidativo , Ratos , Ratos Wistar , Substâncias Reativas com Ácido Tiobarbitúrico/metabolismo , Tirosina 3-Mono-Oxigenase/metabolismo
19.
Cell Tissue Res ; 333(2): 263-79, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18568366

RESUMO

Myosin-Va is a Ca(2+)/calmodulin-regulated unconventional myosin involved in the transport of vesicles, membranous organelles, and macromolecular complexes composed of proteins and mRNA. The cellular localization of myosin-Va has been described in great detail in several vertebrate cell types, including neurons, melanocytes, lymphocytes, auditory tissues, and a number of cultured cells. Here, we provide an immunohistochemical view of the tissue distribution of myosin-Va in the major endocrine organs. Myosin-Va is highly expressed in the pineal and pituitary glands and in specific cell populations of other endocrine glands, especially the parafollicular cells of the thyroid, the principal cells of the parathyroid, the islets of Langerhans of the pancreas, the chromaffin cells of the adrenal medulla, and a subpopulation of interstitial testicular cells. Weak to moderate staining has been detected in steroidogenic cells of the adrenal cortex, ovary, and Leydig cells. Myosin-Va has also been localized to non-endocrine cells, such as the germ cells of the seminiferous epithelium and maturing oocytes and in the intercalated ducts of the exocrine pancreas. These data provide the first systematic description of myosin-Va localization in the major endocrine organs of rat.


Assuntos
Glândulas Endócrinas , Cadeias Pesadas de Miosina/metabolismo , Miosina Tipo V/metabolismo , Glândulas Suprarrenais/citologia , Glândulas Suprarrenais/metabolismo , Animais , Glândulas Endócrinas/citologia , Glândulas Endócrinas/metabolismo , Immunoblotting , Ilhotas Pancreáticas/citologia , Ilhotas Pancreáticas/metabolismo , Glândulas Paratireoides/citologia , Glândulas Paratireoides/metabolismo , Glândula Pineal/citologia , Glândula Pineal/metabolismo , Hipófise/citologia , Hipófise/metabolismo , Ratos , Glândula Tireoide/citologia , Glândula Tireoide/metabolismo , Distribuição Tecidual
20.
Pharmacol Biochem Behav ; 79(3): 499-506, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15582021

RESUMO

Partial sleep deprivation is clinically associated with fatigue, depressive symptoms and reduced memory. Previously, it has been demonstrated that venlafaxine, an atypical antidepressant, increases the levels of noradrenaline and serotonin in rat hippocampus. The aim of this study was to evaluate the effects of venlafaxine on depression, anxiety, locomotor activity and memory in a model of REM sleep (REMs) deprivation in rats. We have also studied the influence of venlafaxine on monoamine levels in the striatum. Six groups of animals (N=20 each) were treated with saline or venlafaxine (1 or 10 mg/kg) during 10 days, submitted or not to REMs deprivation and studied with the forced swimming test of Porsolt (STP), plus-maze, passive avoidance and open-field tests right after sleep deprivation. Animals were also studied for passive avoidance 24 h later (rebound period). Brain samples for monoamine measurements were collected either immediately after REMs deprivation or after 24 h. Both REMs deprivation and venlafaxine showed an antidepressant effect. An anxiolytic effect was also observed after REMs deprivation. Previous treatment with venlafaxine blocked the antidepressant and anxiolytic effects of REMs deprivation. REMs deprivation alone and treatment with venlafaxine 10 mg/kg increased locomotor activity, and this effect was inhibited by venlafaxine in REMs deprived rats. Both venlafaxine treatment and REMs deprivation induced weight loss. Venlafaxine treatment, but not REMs deprivation, induced an increase in striatal dopamine (DA) levels. The combination of REMs deprivation and venlafaxine treatment was associated with an increase in serotonin turnover 24 h after rebound sleep. In this study, venlafaxine treatment hindered most behavioral effects of REMs deprivation and was associated with an interference on dopamine and serotonin systems in the striatum.


Assuntos
Peso Corporal/efeitos dos fármacos , Corpo Estriado/efeitos dos fármacos , Cicloexanóis/farmacologia , Atividade Motora/efeitos dos fármacos , Privação do Sono/metabolismo , Animais , Peso Corporal/fisiologia , Corpo Estriado/metabolismo , Cicloexanóis/uso terapêutico , Feminino , Imobilização/fisiologia , Aprendizagem em Labirinto/efeitos dos fármacos , Aprendizagem em Labirinto/fisiologia , Memória/efeitos dos fármacos , Memória/fisiologia , Atividade Motora/fisiologia , Ratos , Ratos Wistar , Privação do Sono/tratamento farmacológico , Cloridrato de Venlafaxina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...