1.
Technol Health Care ; 25(4): 791-796, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28436406

RESUMO

National recommendations in Sweden recommend a safety distance of 3 meter (m) between mobile phones and medical-electrical (ME) equipment in hospitals. A questionnaire was used to investigate how often mobile phones were reported to interfere with ME products in clinical practice across Sweden. The results confirmed that ME equipment can be affected by mobile phone use but, the risk of the patient's outcome being affected were minimal; no cases were identified which led to injury or death. In conclusion, the results support recommendations for a general safety distance of 0.5 m between mobile phones and ME equipment in care environments.


Assuntos
Telefone Celular/instrumentação , Campos Eletromagnéticos , Equipamentos e Provisões Hospitalares , Hospitais/normas , Humanos , Suécia
2.
Ultrasound Med Biol ; 32(5): 665-71, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16677926

RESUMO

Three-dimensional (3-D) ultrasound imaging has improved evaluation of organ circulation and might contribute new information on maternal and fetal blood supply. Flow index (FI) of 3-D color images has been proposed as a measure of perfusion. The aim of this study was to evaluate whether the 3-D FI is a parameter of volume flow and flow velocity in a human vessel and in a flow phantom. A 1-cm-long strip of the uterine artery was recorded in 3-D power Doppler (3D-PD) mode in a cross-sectional study of 170 normal singleton pregnancies between 26 and 42 weeks' gestation. A fixed ultrasound system installation was used during the examination. The VOCAL software integrated in the ultrasound unit calculated vessel volume and FI. Reproducibility of the measurements was tested. The method was also tested on a commercially available flow phantom. Reproducibility measurements gave satisfactory results, both in terms of inter- and intraobserver variation. Unexpectedly, in normal pregnancy, the uterine artery FI decreased slightly with gestation. Uterine artery vessel volume increased, however, with gestational age. A poor correlation was found between the FI and both flow velocity and volume flow in the flow phantom. In conclusion, 3D-PD imaging can give impressive anatomical pictures of organ vascular tree. However, the new FI is poorly related to flow velocity or volume of flow.


Assuntos
Ultrassonografia Pré-Natal/métodos , Útero/irrigação sanguínea , Artérias/diagnóstico por imagem , Artérias/fisiologia , Velocidade do Fluxo Sanguíneo , Feminino , Idade Gestacional , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Imagens de Fantasmas , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Doppler em Cores/métodos