Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Afr Med ; 21(1): 71-76, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35313409

RESUMO

Context: COVID-19 came suddenly, bringing to the fore the challenges inherent in the health system. In a developing country, such as Nigeria, which already had myriad problems with funds and equipment in the health sector. Aims: This study aims to examine the challenges encountered by the staff in Radiology facilities and how they combated the challenges. Settings and Design: A descriptive cross-sectional study of radiology facilities in Nigeria. Subjects and Methods: Radiologists from nine government and four private facilities who attended to COVID-19 patients were asked to fill questionnaires on challenges faced and their coping strategies. Responses were sent through E-mail. Statistical Analysis Used: Data from the responses were analyzed using Microsoft excel for Mac 2011 and presented as figures and tables. Results: Majority of the government 7 (77.8%) and private facilities 4 (100%) had no equipment dedicated only to COVID-19 patients. Seven (77.8%) government facilities complained of inadequate staff, poor availability of personal protective equipment (PPEs) 8 (88.9%), and lack of technology for remote viewing 7 (77.8%). Fear of cross-infection was a challenge in one of the facilities 1 (11.1%). Coping strategies adopted include ensuring less traffic in the department by discouraging walk-in patients and canceling non-emergent cases, booking suspected/confirmed cases for lighter times, using old film for face shields and cloth for facemasks, staff education on COVID-19 and preventive measures, and sending reports to physicians through E-mail. Conclusions: There were a lot of challenges during the COVID-19 crisis, with government hospitals experiencing more challenges than private facilities. The challenges included among others inadequate staff strength and lack of technology for remote viewing. Some were overcome using education and by production of facemasks/shields production using recycled materials.


RésuméLe contexte: COVID-19 came suddenly, bringing to the fore the challenges inherent in the health system. Dans un pays en développement, comme Le Nigeria, qui avait déjà une myriade de problèmes de fonds et d'équipements dans le secteur de la santé. Objectifs : Cette étude vise à examiner les défis rencontrés par le personnel des établissements de radiologie et comment ils ont relevé les défis. Paramètres et conception: une section descriptive étude des installations de radiologie au Nigeria. Sujets et méthodes: Radiologues de neuf établissements publics et de quatre établissements privés qui ont participé aux patients COVID-19 ont été invités à remplir des questionnaires sur les défis rencontrés et leurs stratégies d'adaptation. Les réponses ont été envoyées par courrier électronique. Analyse statistique utilisée: Les données des réponses ont été analysées à l'aide de Microsoft Excel pour Mac 2011 et présentées sous forme de figures et de tableaux. Résultats: La majorité des établissements publics 7 (77,8 %) et privés 4 (100 %) ne disposaient d'aucun équipement dédié uniquement aux patients COVID-19. Sept (77,8 %) établissements publics se sont plaints d'un personnel inadéquat, d'une faible disponibilité des équipements de protection individuelle (EPI) 8 (88,9 %), et le manque de technologie pour la visualisation à distance 7 (77,8 %). La peur d'une infection croisée était un défi dans l'un des établissements 1 (11,1 %). Faire faceles stratégies adoptées comprennent la réduction de la circulation dans le service en décourageant les patients sans rendez-vous et en annulant les cas non urgents, en réservant les cas suspects/confirmés pour des périodes plus légères, en utilisant un vieux film pour les écrans faciaux et un tissu pour les masques faciaux, la formation du personnel sur COVID-19 et mesures préventives et l'envoi de rapports aux médecins par courrier électronique. Conclusions: Il y a eu beaucoup de défis pendant la COVID-19 crise, les hôpitaux publics étant confrontés à plus de défis que les établissements privés. Les défis comprenaient entre autres l'insuffisance la force du personnel et le manque de technologie pour la visualisation à distance. Certains ont été surmontés grâce à l'éducation et à la production de masques faciaux/boucliers utilisant des matériaux recyclés. Mots-clés: défis, les stratégies d'adaptation, COVID-19, Nigeria.


Assuntos
COVID-19 , Radiologia , Adaptação Psicológica , COVID-19/epidemiologia , Estudos Transversais , Humanos , Nigéria/epidemiologia
2.
Afr J Paediatr Surg ; 19(2): 83-88, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35017377

RESUMO

BACKGROUND: Over the last two decades, there has been significant improvement in the outcomes of children with Wilms' tumour (WT) in high income countries (HICs) with approximately 85% survival rate globally. This is partly attributable to a multi-disciplinary team approach to care and the evolution of more robust treatment measures. A previous review in our centre prior to multi-disciplinary team shows a survival rate of 31.48%, However, the survival rates from low- and middle-income countries are still low when compared to HICs due to delays in access to care at all levels, poor to non-existent health insurance coverage, limited workforce resources, weak health-care systems and infrastructure. The aim of this study is to determine the impact of a multi-disciplinary team approach on the treatment outcomes of children with WT. METHODOLOGY: This is a 5-year retrospective review of all patients managed with WT at the Lagos University Teaching Hospital, Lagos, Nigeria. Information was extracted from the patients' case notes, operation notes and ward admission records. The data were analysed with SPSS 25, and P < 0.05 was considered to be statistically significant. RESULTS: Forty patients were included in the study; male to female ratio was 1.6:1. The disease occurred in the right kidney in 23 patients (57.5%) and on the left in 17 patients (42.5%). The average duration of symptoms before presentation was 3.6 months (range 1-7 months), majority of patients presented with abdominal masses and were assessed as per unit protocol with abdominal Computerized tomography scan, chest X-ray and abdominal ultrasound scan to assign the patient International Society of Paediatric oncology regimen. The predominant stage at surgery was Stage III 26 (65%), while Stage IV was 9 (22.5%). Morbidity after chemotherapy was 10 (25%). Twenty-five patients (63%) completed chemotherapy while 15 patients (37%) started chemotherapy but defaulted midway. The 5-year survival rate was 75%. Increasing age and male sex were associated with reduced odds of mortality; however, this was not statistically significant. Increased duration of treatment, being treated with chemotherapy alone, as well as advanced tumour stage and histology were associated with increased odds of mortality, however, this was not statistically significant. CONCLUSION: The development of an institutional WT treatment pathway involving a multidisciplinary team has resulted in improved outcomes. There is need for increased community awareness to improve the time to presentation.


Assuntos
Neoplasias Renais , Tumor de Wilms , Feminino , Humanos , Lactente , Rim , Neoplasias Renais/terapia , Masculino , Nigéria , Estudos Retrospectivos , Tumor de Wilms/terapia
3.
Afr Health Sci ; 19(2): 1866-1874, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31656469

RESUMO

BACKGROUND: Prior studies on Hysterosalpingography (HSG) have shown that pelvic inflammatory disease (PID) related tubal adhesions accounted for 30 - 50% of female infertility, with as high as 80% reported in some studies. With improved access to contraceptives, antibiotics and promotion of safe practices, the abnormal findings in HSG may have reduced or altered. OBJECTIVE: To document the imaging findings in the HSG of participants and to compare current findings with prior studies done nationally and internationally. METHOD: A retrospective evaluation of 974 HSGs done at the tertiary diagnostic center over a 7-year period was conducted and analyzed using diagnostic accuracy tables. RESULTS: Tubal pathologies were the most common abnormality in this study, (35.1% of the cases), comprising tubal blockage and hydrosalpinges; followed by uterine masses seen in 223 (22.9%) of the clients. Tubal occlusion was higher in clients with multiple abnormal findings; while normal sized and large uterine cavities had a higher percentage of bilateral tubal patency. CONCLUSION: Tubal factors remain the most common abnormality seen in the HSGs of infertile women in this study, though with lower prevalence compared with prior older studies. Forty seven (47%) of the cases of female factor infertility had normal HSGs with bilateral tubal patency.


Assuntos
Doenças das Tubas Uterinas/diagnóstico por imagem , Tubas Uterinas/diagnóstico por imagem , Histerossalpingografia/métodos , Infertilidade Feminina/diagnóstico por imagem , Útero/diagnóstico por imagem , Adolescente , Adulto , Distribuição por Idade , Doenças das Tubas Uterinas/complicações , Doenças das Tubas Uterinas/epidemiologia , Feminino , Humanos , Infertilidade Feminina/epidemiologia , Infertilidade Feminina/etiologia , Estudos Retrospectivos , Fatores Socioeconômicos , Adulto Jovem
4.
J Med Imaging Radiat Sci ; 43(2): 108-111, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31052026

RESUMO

OBJECTIVE: To determine the common factors that affect the diagnostic quality of radiographs in radiodiagnostic centers in Lagos state, Nigeria. METHODS: Self-administered questionnaires containing both open- and close-ended questions were distributed to the supervising radiographers in radiodiagnostic centers within the Lagos metropolis. The questions asked included the film/reject ratio in each center and reasons why each film was rejected. RESULTS: Faulty x-ray machines, movement on the part of the patient, poor darkroom film processing, and suboptimal radiographic techniques were the main reasons respondents identified as factors commonly responsible for the production of faulty films. In some cases, more than one of these factors was responsible. CONCLUSION: There is a need to routinely ensure that x-ray machines are properly calibrated in order to reduce the rate of film rejects in our x-ray facilities. In addition, equipment that is old and cannot be properly calibrated should be replaced. This would guarantee optimum performance and reduce radiation dose to patients and personnel. Younger radiographers should also be open to mentoring by older colleagues so they can acquire useful tips on how to reduce the production of films with unacceptable diagnostic quality. They should be encouraged to attend continuing education programs for improved expertise. Also, quality control and maintenance programs such as the reject film analysis or regular equipment maintenance should be enforced in radiodiagnostic centers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...