Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ear Nose Throat J ; 100(10): 710-712, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32466730

RESUMO

OBJECTIVE: To investigate the association of high septal deviation with the olfactory fossa depth and Gera angle. METHODS: Fifty-four computed tomography scans of patients with high septal deviation were evaluated. The olfactory fossa depth and Gera angle were measured. The values of the deviated and nondeviated sides were compared. RESULTS: No association between high septal deviation and the olfactory fossa depth and Gera angle was found. CONCLUSION: High septal deviation does not affect the olfactory fossa depth and Gera angle. In other words, the olfactory fossa depth and Gera angle have no association with the high septal deviation.


Assuntos
Fossa Craniana Anterior/anormalidades , Septo Nasal/anormalidades , Tomografia Computadorizada de Feixe Cônico , Fossa Craniana Anterior/anatomia & histologia , Fossa Craniana Anterior/diagnóstico por imagem , Osso Etmoide/anatomia & histologia , Osso Etmoide/diagnóstico por imagem , Humanos , Septo Nasal/diagnóstico por imagem , Seios Paranasais/diagnóstico por imagem , Estudos Retrospectivos , Base do Crânio/anatomia & histologia , Base do Crânio/diagnóstico por imagem
2.
Am J Rhinol Allergy ; 30(4): 287-93, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27456598

RESUMO

BACKGROUND: Since 1972, patients with large nasal perforations, who were symptomatic, and who were not candidates for surgery, had the option of custom prosthetic closure at Mayo Clinic. Although septal prostheses have helped many patients, 27% of pre-1982 patients chose not to keep the prosthesis in place. Two-dimensional computed tomography (CT) sizing resulted in more of the patients choosing to retain the prosthesis. The introduction of three-dimensional (3-D) printing to the sizing process offered the potential of further improved retention by refinement in prosthesis fit. OBJECTIVE: To describe the fabrication of nasal septal prostheses by using 3-D printing for sizing and to compare the retention rate of 3-D-sized prostheses with those that used previous sizing methods. METHODS: Twenty-one consecutive patients who had placement of septal prostheses sized by using 3-D printed templates were studied. CT image data were used to print 3-D templates of the exact shape of the patient's septal perforation, and medical-grade silastic prostheses were fabricated to fit. In four cases, the 3-D printed template allowed preoperative surgical simulation. Metrics collected included prosthesis retention; symptoms, including intranasal crusting and epistaxis; and previous prosthetic closure failures. RESULTS: Twenty of the twenty-one patients had improvement in symptoms. The mean diameter of the perforations was 2.4 cm; the mean closure time by the end of the study period was 2.2 years. All but two patients chose to keep their prosthesis in place, for a retention rate of 90%. Seven patients with successful closure had failed previously with prior prosthesis sized without the current 3-D printing methodology. This 90% retention rate exceeded the previous rates before the introduction of 3-D sizing. CONCLUSION: Sizing done by 3-D printing for prosthetic closure of nasal septal perforations resulted in a higher retention rate in helping patients with these most-challenging nasal septal perforations.


Assuntos
Perfuração do Septo Nasal/cirurgia , Septo Nasal/cirurgia , Impressão Tridimensional , Próteses e Implantes , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfuração do Septo Nasal/diagnóstico por imagem , Perfuração do Septo Nasal/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA