Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(4): e012424, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390713

RESUMO

BACKGROUND: The National Cardiovascular Data Registry Left Atrial Appendage Occlusion Registry (LAAO) includes the vast majority of transcatheter LAAO procedures performed in the United States. The objective of this study was to develop a model predicting adverse events among patients undergoing LAAO with Watchman FLX. METHODS: Data from 41 001 LAAO procedures with Watchman FLX from July 2020 to September 2021 were used to develop and validate a model predicting in-hospital major adverse events. Randomly selected development (70%, n=28 530) and validation (30%, n=12 471) cohorts were analyzed with 1000 bootstrapped samples, using forward stepwise logistic regression to create the final model. A simplified bedside risk score was also developed using this model. RESULTS: Increased age, female sex, low preprocedure hemoglobin, no prior attempt at atrial fibrillation termination, and increased fall risk most strongly predicted in-hospital major adverse events and were included in the final model along with other clinically relevant variables. The median in-hospital risk-standardized adverse event rate was 1.50% (range, 1.03%-2.84%; interquartile range, 1.42%-1.64%). The model demonstrated moderate discrimination (development C-index, 0.67 [95% CI, 0.65-0.70] and validation C-index, 0.66 [95% CI, 0.62-0.70]) with good calibration. The simplified risk score was well calibrated with risk of in-hospital major adverse events ranging from 0.26% to 3.90% for a score of 0 to 8, respectively. CONCLUSIONS: A transcatheter LAAO risk model using National Cardiovascular Data Registry and LAAO Registry data can predict in-hospital major adverse events, demonstrated consistency across hospitals and can be used for quality improvement efforts. A simple bedside risk score was similarly predictive and may inform shared decision-making.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fatores de Risco , Resultado do Tratamento
2.
Heart Rhythm ; 20(7): 1000-1008, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36963741

RESUMO

BACKGROUND: Despite strong guideline recommendations for cardiac resynchronization therapy-defibrillator (CRT-D) in select patients, this therapy is underutilized with substantial variation among hospitals, and the association of this variation with outcomes is unknown. OBJECTIVE: The purpose of this study was to assess whether facility variation in CRT-D utilization is associated with differences in hospital-level outcomes. METHODS: We linked Medicare claims data with the National Cardiovascular Data Registry's ICD Registry from 2010 to 2015. We calculated the intraclass correlation coefficient to quantify the degree of variation in patient-level CRT use that can be explained by interfacility variation on a hospital level. To quantify the degree of hospital variation in patient-level outcomes (all-cause mortality, readmissions, and cardiac readmissions) that can be attributed to variations in CRT-D use, we utilized multilevel modeling. RESULTS: The study included 30,134 patients across 1377 hospitals. The median rate of CRT-D implantation in those meeting guideline indications was 89%, but there was a wide variation across hospitals. After adjustment, most of the variation (74%) in hospital rates of CRT-D utilization was attributable to the hospital in which the patient was treated. Differences in hospital CRT-D utilization was associated with 8.76%, 5.26%, and 4.71% of differences in hospital mortality, readmissions, and cardiac readmission rates, respectively (P < .001 for all outcomes). CONCLUSION: There is a wide variation in the use of CRT-D across hospitals that was not explained by case mix. Hospital-level variation in CRT-D utilization was associated with clinically significant differences in outcomes. A measure of CRT-D utilization in eligible patients may serve as a useful metric for quality improvement efforts.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Idoso , Estados Unidos/epidemiologia , Medicare , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Hospitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...