Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Crit Care Res Pract ; 2019: 2842313, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31827924

RESUMO

BACKGROUND: Continuous renal replacement therapy (CRRT) is an essential procedure for patients with acute kidney injury in intensive care. It is important to maintain an adequate blood flow rate during CRRT. Several previous studies have reported the relationships between blood flow rate and filter lifespan, or circuit life, in CRRT. Here, we aim at elucidating the incidence and factors associated with a decreased blood flow rate in CRRT. METHODS: This is a retrospective observational study. From January 2014 to June 2017, 119 patients who underwent CRRT in the intensive care unit were enrolled. The definition of a decreased blood flow rate included situations in which the medical staff needed to decrease the blood flow volume. We statistically analyzed the association of the decreased blood flow rate with patients' clinical characteristics. RESULTS: Of 119 patients, 52 required a decreased blood flow rate during CRRT. Almost half of the cases occurred within one day of starting CRRT. None of the clinical factors (age, sex, height, sequential organ failure assessment (SOFA) score, catheter position, systemic infection, albumin, hemoglobin, and activating coagulation time) were significantly associated with decreased blood flow rate. CONCLUSIONS: A decreased blood flow rate often occurs during CRRT. Clinical factors significantly associated with the occurrence of the decreased blood flow rate were not detected in the current study. Further investigation regarding the occurrence of a decreased blood flow is warranted.

2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 60(7): 969-74, 2004 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-15340278

RESUMO

In this study, we evaluated the performance of a digital chest imaging system using a contrast-detail (C-D) phantom. In the initial step, 76 sample images of the C-D phantom were produced by changing the doses from 0.5, 0.75, 1.0, 1.25, 1.5, to 2.0 times the dose for a screen-film (S/F) system. The sample images were analyzed by five radiological technologists and two medical physicists, and the image quality figure (IQF) was determined. The quality of each image was examined, and appropriate doses were determined from the calculated IQF to obtain the same image quality for other digital chest imaging systems. The method of determining IQF from C-D phantom analysis was very useful for comparing image quality and determining radiographic techniques.


Assuntos
Imagens de Fantasmas , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Radiografia Torácica/métodos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...