Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Pediatr ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795136

RESUMO

Preterm neonates are at risk for neurodevelopmental impairment, especially those with intraventricular hemorrhage (IVH). Cerebral vasospasm (VSP) is a common complication after subarachnoid hemorrhage (SAH) in adult population, but it is unknown if preterm neonates with IVH may develop it. We prospectively enrolled premature newborns < 32 weeks with IVH and without IVH. All patients received serial transcranial sonography through the temporal window of the middle cerebral artery, anterior cerebral artery, posterior cerebral artery, and the internal carotid artery with transcranial Doppler sonography days 2, 4, and 10 of life. Cerebral blood velocities (CBFVs) were measured including median velocity flow (MV), peak systolic velocity (PSV), and maximum end-diastolic velocity (EDV). Resistance index and pulsatility index were calculated. VSP was defined as an increase of 50% in the baseline velocity per day and/or a Lindegaard ratio higher than 3. Fifty subjects were enrolled. None of the patients with IVH showed elevation of MV or a Lindegaard ratio > 3. There were no differences between IVH and without IVH groups regarding resistance index and pulsatility index.    Conclusion: Preterm infants with IVH do not present a pattern of VSP analyzed by Doppler transcranial ultrasound in this pilot study. What is Known: • In adult population with subarachnoid hemorrhage the most treatable cause of cerebral ischemia is due cerebral vasospasm but is unknown if premature newborn may have vasospasm due the extravasation of blood in the context of intraventricular hemorrhage What is New: •In this pilot study we did not find in premature newborn with intraventricular hemorrhage signs of vasoespam measured by transcranial color doppler ultrasound.

2.
Pediatr Pulmonol ; 57(10): 2502-2510, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35792663

RESUMO

BACKGROUND: Lung ultrasound (LUS) is a bedside tool useful to diagnose neonatal respiratory disease and to guide surfactant therapy. LUS scores have emerged as useful tool for newborn respiratory distress but is unknown if respiratory support settings may influence it. The aim of the study was to evaluate the feasibility of LUS scores evaluating lung recruitment in term newborns with respiratory distress when noninvasive respiratory it is increased. MATERIAL AND METHODS: Prospective study in a tertiary neonatal intensive care unit. Inclusion criteria were term neonates with respiratory distress requiring noninvasive respiratory support with nasal continuous positive airway pressure (nCPAP) within first 6 h of life with an LUS score higher than 8 were enrolled. LUS was performed three times. First LUS (LUS-1) was done in patients in nCPAP (Fabian Device) (Acutronic) (pressure of 6 cmH2 O). Afterwards patients were placed in duo positive airway pressure (12/6 cmH2 O), a second LUS (LUS-2) was performed immediately and a third (LUS-3) was done 2 h later on the same respiratory support. The primary outcome was to compare LUS scores in the different timelines. Second outcomes were to evaluate the level of respiratory distress and oxygenation were evaluated with SpO2 /fraction of inspired oxygen (FiO2 ) ratio (S/F ratio), FiO2  ratio, respiratory rate, and blood gas analysis which were analyzed during the LUS-1 and the LUS-3. To evaluate newborn discomfort, patients were evaluated with Crying Requires oxygen Increased vital signs Expression Sleep (CRIES) scale. RESULTS: Forty neonates were enrolled. Fifty percent were female (n = 20), median gestational age was 38 + 4 (interquartile range [IQR]: 37 + 5-39 + 4) with a median weight of 3155 g (IQR: 2637-3532). Duration of non invasive ventilation support was 72 h (IQR: 54-96). None of the patients required surfactant therapy or mechanical ventilation. LUS scores were no different between LUS-1 9 (IQR: 8.3-10) and LUS-2 9 (IQR: 8.3-10) (p = 0.675) but there were differences between LUS-1 and LUS-3 7 (IQR: 6.3-8.5) (p = 0.036). There was an improvement in the oxygen parameters, respiratory rate, and CO2 between LUS-1 and LUS-3 (p < 0.001). There were no changes in the CRIES scale. CONCLUSIONS: There is an improvement in clinical and laboratory parameters after the increasing of respiratory support in newborns with noninvasive ventilation. We observe a correlation with an improvement in the assessment of lung aeration were evaluated with LUS score.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Dióxido de Carbono , Dispneia , Feminino , Humanos , Recém-Nascido , Pulmão/diagnóstico por imagem , Masculino , Oxigênio , Estudos Prospectivos , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Tensoativos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...