Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Masui ; 63(1): 84-7, 2014 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-24558938

RESUMO

A 5-year-old girl was admitted to our hospital after resuscitation from cardiac arrest due to near-drowning accident in a river. On admission, Glasgow Coma Scale score was 7; arterial blood pressure was 113/73 mm Hg; heart rate was 157 beats x min(-1), and percutaneous oxygen saturation was 99% on 10 l x min(-1) of oxygen. The patient was intubated with a 5.0 mm internal diameter endotracheal tube, and therapeutic hypothermia was started for neural protection. Hypothermia in the target temperature of 34 degrees C was maintained for 24 hours using Arctic Sun System. Although the patient had been sedated with fentanyl 0.6-1.2 microg x kg(-1) x hr(-1), midazolam 0.2-0.4 mg x kg(-1) x hr(-1) and dexmedetomidine 0.6-1.0 mirog x kg(-1) x hr(-1), agitation increased during the rewarming period following hypothermia. To avoid accidental extubation, we used Anchor Fast as a device for securing oral endotracheal tube. Anchor Fast kept the tube position properly even though the patient was turned or moved. Seventy-two hours later, she was rewarmed and extubated as scheduled. Ten days after admission, she was discharged without any neurological deficits.


Assuntos
Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Hipotermia Induzida/métodos , Intubação Intratraqueal/instrumentação , Afogamento Iminente/complicações , Pré-Escolar , Feminino , Humanos , Intubação Intratraqueal/métodos , Doenças do Sistema Nervoso/etiologia , Doenças do Sistema Nervoso/prevenção & controle , Ressuscitação , Resultado do Tratamento
2.
Masui ; 62(8): 939-41, 2013 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-23984568

RESUMO

A 63-year-old female with obesity (body mass index of 32.0 kg x m(-2)) was scheduled for total abdominal hysterectomy under combined epidural general anesthesia. The surgical procedure was completed without any troubles. Immediately after tracheal extubation, however, the patient developed acute respiratory distress, and the percutaneous oxygen saturation (Spo2) decreased from 97 to 44% for 1 minute. When the patient was admitted to our intensive care unit due to hypoxia, arterial blood gas values showed pH 7.37, Paco2 40.4 mmHg, Pao2 67.5 mmHg, and Spo2 94% on 5 l x min(-1) of oxygen via face mask. Her respiratory rate was 23 breaths x min(-1). We used a nasal high-flow humidified oxygen system (Optiflow) to improve oxygenation. We set the initial flow rate at 35 l x min(-1) with 50% oxygen. One hour after initiating the nasal high-flow system, the patient's respiratory rate fell to 18 breaths x min(-1), and Spo2 rose up to 98%. Arterial blood gas showed improved Pao2 of 98.0 mmHg. Nasal high-flow therapy was useful to avoid intubation in a patient with postanesthetic respiratory failure.


Assuntos
Extubação , Hipóxia/terapia , Oxigenoterapia/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade
3.
Artif Organs ; 27(10): 882-6, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14616530

RESUMO

Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged continuous flow left heart bypass. The aortic samples from three goats in which continuous flow left heart bypass was performed were subjected to histological and immunohistochemical analyses. After 4 weeks of observation, the pulse pressure in the goats under the continuous flow left heart bypass was clearly lower than that in the normal healthy goats. The aortic walls of these goats became thinner, an effect caused by the dilation of their internal diameter. These aortic smooth muscle cells maintained contractile formation due to the fact that they contained abundant alpha-smooth muscle actin (SMA) and smooth muscle myosin heavy chain (SMMS). These cells also synthesized redundant matrix metalloproteinase-2 and -9, and the ratio of the SMMS-positive to the SMA-positive area was significantly lower (0.76) than that observed in the control goat (1.00; P < 0.05). The smooth muscle cells demonstrated synthetic-dedifferentiated formation, which is one of the phenotypes of smooth muscle cell function. In conclusion, aortic wall thinness under prolonged continuous flow left heart bypass is caused by over-synthesis of matrix metalloproteinase in smooth muscle cells, and this refers the vascular remodeling process of the extracellular matrix.


Assuntos
Derivação Cardíaca Esquerda , Metaloproteinases da Matriz/biossíntese , Músculo Liso Vascular/citologia , Animais , Aorta/citologia , Aorta/patologia , Cabras , Imuno-Histoquímica
4.
Artif Organs ; 27(10): 907-13, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14616534

RESUMO

The integrated heart lung assist device (IHLAD) has been developed to overcome the problems of currently available extracorporeal membrane oxygenation devices. The integrated structure of a centrifugal blood pump and cylindrical bundle of polyolefin hollow-fibers has allowed a remarkably compact size for the device. This study deals with the design change of the IHLAD that added to the vaned diffuser between the impeller of the centrifugal pump and the hollow-fiber bundle with a view to enhancing the gas-transfer performance. Ex vivo gas-transfer performance tests were carried out, as well as hydrodynamic characteristics and hemolysis test using fresh goat blood. The oxygen transfer rate was generally improved, and the carbon dioxide removal rate was slightly improved. Intolerable amount of hemolysis (index of hemolysis= 0.177) was caused by the IHLAD, which must be resolved by improving the design in the future.


Assuntos
Coração Auxiliar , Máquina Coração-Pulmão , Animais , Dióxido de Carbono/sangue , Desenho de Equipamento , Cabras , Teste de Materiais , Membranas Artificiais , Oxigênio , Oxigenadores de Membrana
5.
Artif Organs ; 27(10): 914-9, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14616535

RESUMO

The configuration of the vaned diffuser of the integrated heart lung assist device (IHLAD) has been revised to reduce mechanical blood trauma caused by the device. The flow visualization study of the flow near the diffuser vanes revealed the existence of a rotating stall which deteriorates the hydrodynamic performance of the device and augments the chance for blood cells to pass through the regions with intense shearing forces. Design changes of the diffuser included decrease in vane number from 7 to 5 and decrease in passage width from 3 mm to 2 mm. This design change was effective to suppress initiation of a rotating stall. Improvement of hydrodynamic performance and antihemolytic properties was confirmed with the newly designed configuration based on the flow visualization study.


Assuntos
Coração Auxiliar , Máquina Coração-Pulmão , Centrifugação , Desenho de Equipamento , Hemólise , Oxigenadores de Membrana , Reologia , Rotação
6.
ASAIO J ; 49(3): 243-9, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12790371

RESUMO

Electrohydraulic total artificial heart (EHTAH) and electrohydraulic ventricular assist device (EHVAD) systems have been developed in our institute. The EHTAH system comprises a pumping unit consisting of blood pumps and an actuator, as well as an electronic unit consisting of an internal controller, internal and external batteries, and transcutaneous energy transfer (TET) and optical telemetry (TOT) subunits. The actuator, placed outside the pericardial space, reciprocates and delivers hydraulic silicone oil to the alternate blood pumps through a pair of flexible oil conduits. The pumping unit with an external controller was implanted in 10 calves as small as 55 kg. Two animals survived for more than 12 weeks in a good general condition. The assumed cardiac output ranged between 6 and 10 L/min, the power consumption was 12-18 W, and the energy efficiency was estimated to be 9-11%. Initial implantation of subtotal system including electronic units was further conducted in another calf weighing 73 kg. It survived for 3 days with a completely tether free system. The EHVAD system is developed by using the left blood pump and the actuator of the EHTAH, which were packaged in a compact metal casing with a compliance chamber. In vitro testing demonstrated maximum output more than 9 L/min and more than 13% maximum efficiency. The initial animal testing lasted for 25 days. These results indicate that our EHTAH and EHVAD have the potential to be totally implantable systems.


Assuntos
Coração Artificial , Animais , Débito Cardíaco/fisiologia , Bovinos , Desenho de Equipamento , Coração Artificial/efeitos adversos , Tromboembolia/etiologia
7.
ASAIO J ; 48(6): 668-70, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12455781

RESUMO

In the mechanism of damage to red blood cells (RBCs) caused by a centrifugal pump, the prolonged effects to the RBC membrane caused by exposure to shear stress remain unclear. We focused on the band 3 protein (B3), one of the major proteins in the membrane skeleton, and investigated the ultrastructural alterations of the RBC membrane with loaded shear stress. Using flow cytometry, the relative amount of B3 was examined in relation to RBC deformability. The results, with continuous exposure to low shear stress, showed cell downsizing, an increase in B3 density, and a decrease in the deformability of the RBC membrane. Exposure to high shear stress does not appear to exert any influence on the membrane skeleton of the RBC. Therefore, in addition to conventional processes including the instantaneous destruction of a cell due to intense shear stresses, the results of the present study indicate the presence of another process based on changes in membrane proteins leading to cell fragmentation. Under low shear stress, the RBC membrane skeleton shows delayed destruction, which is exhibited as a disorder of B3 distribution, and the related membrane dysfunction includes decreases in RBC deformability and stability.


Assuntos
Deformação Eritrocítica/fisiologia , Membrana Eritrocítica/patologia , Membrana Eritrocítica/fisiologia , Animais , Viscosidade Sanguínea , Citoesqueleto/fisiologia , Membrana Eritrocítica/ultraestrutura , Citometria de Fluxo , Cabras , Hemólise , Bicamadas Lipídicas , Estresse Mecânico
8.
Artif Organs ; 26(11): 974-9, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12406155

RESUMO

We investigated morphological changes of the arterial systems in the kidneys under prolonged continuous flow left heart bypass. Twelve goats were subjected to 2 weeks of pulsatile left heart bypass followed by 4 weeks of continuous flow left heart bypass (group CF). After autopsy, the kidneys underwent pathological evaluation. Six normal healthy goats were used as controls. The media of the afferent arterioles of group CF were frequently thickened by an increase in the number of the mature smooth muscle cells (SMCs). The juxtaglomerular areas (JGA) were expanded because of an increase in the number and size of SMCs and/or SMC-like cells. Furthermore, the percentage of anti-proliferating cell nuclear antigen antibody-positive cells in the JGA of group CF (9.9 +/- 1.9%) was significantly higher (p = 0.025) than that of the control group (4.6 +/- 3.4%), indicating active proliferation in group CF. We concluded that prolonged continuous flow left heart bypass causes proliferation of SMCs and/or SMC-like cells in the afferent arterioles and their perivascular tissue.


Assuntos
Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/terapia , Derivação Cardíaca Esquerda , Artéria Renal/patologia , Animais , Modelos Animais de Doenças , Cabras , Hemodinâmica/fisiologia , Sistema Justaglomerular/patologia , Sistema Justaglomerular/fisiopatologia , Fluxo Pulsátil/fisiologia , Artéria Renal/fisiopatologia , Circulação Renal/fisiologia , Fatores de Tempo , Túnica Média/patologia , Túnica Média/fisiopatologia
9.
ASAIO J ; 48(5): 503-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12296570

RESUMO

Aortic pressure declines during cardiopulmonary bypass (CPB), particularly at normothermia. It has been reported that administering vasoconstrictors during normothermic CPB (NCPB) to restore perfusion pressure might induce hypoperfusion of splanchnic organs. We have reported that prostaglandin (PG), metabolized in the lung but increased during CPB, might have played a substantial role in hypotension, and that a PG synthesis inhibitor (PGSI) could improve hypotension during CPB. This study was designed to examine whether regional perfusion of splanchnic organs was reduced when PGSI restored systemic perfusion pressure during NCPB. NCPB was performed in eight adult goats for 60 minutes (body weight 57.0 +/- 5.9 kg). PGSI was administered in group P (n = 4), while norepinephrine was administered in group C (n = 4), to keep aortic pressure in the range of 50 to 80 mm Hg. The total systemic flow was maintained at approximately 70 ml/kg/min. Tissue blood flow was measured by means of the colored microsphere method before and 30 and 60 minutes after the start of CPB. In group P, gut blood flows after the start of CPB were higher than those before CPB, significantly in the stomach and jejunum at 30 minutes (p < 0.05), whereas gut blood flows in group C were decreased or not changed. In conclusion, PGSI prevents hypotension without impairing gut perfusion during NCPB.


Assuntos
Ponte Cardiopulmonar/métodos , Inibidores de Ciclo-Oxigenase/farmacologia , Flurbiprofeno/farmacologia , Hipotensão/prevenção & controle , Prostaglandinas/biossíntese , Circulação Esplâncnica , Animais , Pressão Sanguínea , Temperatura Corporal , Cabras , Jejuno/irrigação sanguínea , Pulmão/metabolismo , Microesferas , Norepinefrina/farmacologia , Oxigênio/metabolismo , Estômago/irrigação sanguínea , Vasoconstritores/farmacologia
10.
Artif Organs ; 26(8): 676-81, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12139494

RESUMO

We have reported that infusion of prostaglandin synthesis inhibitor (PGSI) reduced the severity of hypotension during normothermic cardiopulmonary bypass (CPB). In the present study, we investigated the effects of PGSI on humoral conditions and whole body oxygen metabolism during normothermic CPB conducted for 60 min in 8 adult goats. The PGSI group (n = 4) was administered 100 to 150 mg of flurbiprofen, a potent PGSI, before and during CPB, and the control group (n = 4) was administered noradrenaline (NA) to restore hypotension. The prostaglandin E2 (PGE2) and NA concentrations in the PGSI group were significantly lower than those of the control group (PGE2 8.8 +/- 1.0 versus 30.3 +/- 11.5 pg/ml, NA 431 +/- 197 versus 3847 +/- 2,153 pg/ml). The adrenaline concentration was not significantly different between the groups. The oxygen consumption and the oxygen extraction rate were not significantly different between the groups, but the blood lactate level in the PGSI group was lower than that of the control group (34.3 +/- 7.6 versus 43.7 +/- 3.8 mg/dl). In conclusion, PGSI improves humoral disorder and thus prevents inadequate tissue oxygen delivery.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Inibidores de Ciclo-Oxigenase/farmacologia , Flurbiprofeno/farmacologia , Hipotensão/tratamento farmacológico , Consumo de Oxigênio/efeitos dos fármacos , Análise de Variância , Animais , Dinoprostona/biossíntese , Cabras , Hemodinâmica , Hipotensão/etiologia , Norepinefrina/farmacologia , Oxigênio/metabolismo , Vasoconstritores/farmacologia
11.
Artif Organs ; 26(6): 548-51, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12072113

RESUMO

We developed an extracorporeal membrane oxygenation (ECMO) system with high antithrombogenicity and durability characteristics for prolonged continuous cardiopulmonary support. The oxygenator consists of a special hollow-fiber-type polyolefin gas-exchange membrane, which has an ultrathin dense layer in contact with the blood, in order to prevent plasma leakage during protracted use (Platinum Cube NCVC). The centrifugal pump (RotaFlow) is free of seals. The entire blood-contacting surface of the system is coated with a newly developed heparin material (Toyobo-NCVC coating). We performed a venoarterial bypass in a goat, and the ECMO system was driven for 34 days without systemic anticoagulants. Plasma leakage from the oxygenator did not occur, and sufficient gas exchange performance was maintained. Thrombus formation was hardly observed in the ECMO system except in the casing margins of the oxygenator. This ECMO system showed potential for long-term cardiopulmonary support with minimal or no use of systemic anticoagulants.


Assuntos
Anticoagulantes/uso terapêutico , Oxigenação por Membrana Extracorpórea/instrumentação , Parada Cardíaca/terapia , Perfusão/instrumentação , Insuficiência Respiratória/terapia , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Cabras , Fatores de Tempo
12.
ASAIO J ; 48(1): 83-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11814103

RESUMO

We previously reported that detection of two specific points (the t-point and the s-point) in the relationship between pump speed and Motor Current Amplitude index (ICA) indicates the safe driving range for a continuous-flow ventricular assist device (CFVAD). During the first stage of the present experiment, the characteristic curves relating pump speed and ICA were determined by varying preload (left atrial pressure: -6 to 30 mm Hg), afterload (total circuit resistance: 890 to 3,180 dyne x sec x cm(-5)), and contractility of the left ventricle (total circuit flow: 0.5 to 2.1 L/min). These data showed that an ICA value of 0.18 was always located between the t- and s-points. During the second stage of the experiment, we developed an automatic driving program to control pump speed by maintaining ICA at 0.18. This program was able to drive the CFVAD, without exhibiting regurgitant flow or sucking, under various driving conditions in the mock circulation. Pump speed stabilized within 1 minute after varying the drive conditions. This sensorless method of driving the CFVAD by using a target ICA proved feasible and effective for safe automatic control, within our mock circulation.


Assuntos
Coração Auxiliar , Algoritmos , Velocidade do Fluxo Sanguíneo , Desenho de Equipamento , Estudos de Avaliação como Assunto , Humanos , Técnicas In Vitro , Contração Miocárdica , Pressão Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...