Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Anim ; 43(4): 333-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19505938

RESUMO

Vascular ultrasound is a reliable non-invasive tool used for the routine assessment of vascular flow and patency in human recipients. We describe the use at three different time points (immediately, 1 week and 4 weeks postsurgery) of ultrasound studies and its validation by angiographic studies in 37 swine undergoing carotid graft replacement. We calculated predictive values (>92%), sensitivity (>85%) and specificity (>92%) with high results at all time points. Ultrasound appeared as an accessible non-invasive technique, providing rapid, safe, repeatable and reliable results. It is an excellent alternative to angiography, avoiding risks inherent to invasive methods and therefore contributing to animal welfare.


Assuntos
Oclusão de Enxerto Vascular/veterinária , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Fluxo Sanguíneo Regional/fisiologia , Cirurgia Veterinária/métodos , Ultrassonografia Doppler/veterinária , Grau de Desobstrução Vascular/fisiologia , Animais , Prótese Vascular/veterinária , Implante de Prótese Vascular/veterinária , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Angiografia por Ressonância Magnética/veterinária , Valor Preditivo dos Testes , Estudos Prospectivos , Suínos
2.
Eur Surg Res ; 40(4): 333-40, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18303269

RESUMO

BACKGROUND AND AIM: The undersizing of the bypass graft diameter compared to native artery changes blood flow characteristics and velocity which may affect conduit neo-endothelialization, intimal hyperplasia reaction and patency. The aim of this study was to evaluate conduit neoendothelialization, intimal hyperplasia reaction and patency results between undersized and matched ePTFE grafts. MATERIAL AND METHODS: In 16 male Sprague-Dawley rats, undersized (1-mm internal diameter) and matched (2-mm internal diameter) ePTFE grafts were anastomosed end-to-end in the infrarenal abdominal aorta. Blood flow volume per minute was measured and wall shear stress was calculated for each group. After 3 weeks of follow-up, angiography was performed via the left carotid artery just before sacrifice. Conduit neoendothelialization and intimal hyperplasia reaction were measured by computer-assisted morphometry. RESULTS: Wall shear stress was 8 times higher for the undersized group (840.56 vs. 105.07 mPa). Three weeks after implantation, conduit neoendothelialization was better in matched grafts compared to undersized grafts (441 vs. 574 microm, p = 0.008). Intimal hyperplasia reaction was similar for both groups (8.7 vs. 6.7 microm(2)/microm for undersized and matched grafts, respectively). Patency rate was 7/8 for undersized and 8/8 for matched ePTFE grafts. CONCLUSION: Although the graft patency and the intimal hyperplasia reaction were not different between the two groups after 3 weeks, matched grafts had a significantly better endothelialization compared to undersized grafts. This short-term beneficial effect may influence long-term patency results.


Assuntos
Aorta Abdominal/cirurgia , Prótese Vascular , Endotélio Vascular/fisiologia , Regeneração/fisiologia , Túnica Íntima/fisiologia , Grau de Desobstrução Vascular/fisiologia , Animais , Aorta Abdominal/patologia , Aorta Abdominal/fisiologia , Aortografia , Arteriopatias Oclusivas/cirurgia , Fenômenos Biomecânicos , Endotélio Vascular/patologia , Masculino , Politetrafluoretileno , Ratos , Ratos Sprague-Dawley
3.
Int J Artif Organs ; 29(10): 990-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17211821

RESUMO

BACKGROUND: Patency of small synthetic bypass grafts is inferior compared to autologous grafts for revascularization procedures. Titanium coating of foreign surfaces has shown to decrease thrombogenicity, enhance biocompatibility and promote adhesion of endothelial cells. The aim of this study was to test the effect of titanium coating of small diameter ePTFE grafts on short term patency, neo-endothelialization and neointimal proliferation. METHODS: Bilateral carotid graft interposition was performed in 5 pigs with uncoated (n=5) and titanium-coated (n=5) ePTFE grafts (internal diameter=4 mm, length=5 cm), thus each pig served as its own control. At the end of the study (30 +/- 3 days), patency and stenosis severity was assessed by carotid angiography. Animals were sacrificed and grafts were excised for histology and scanning electron microscopy. Morphometry of histologic sections was carried out to determine neointimal proliferation and percentage of neo-endothelial coverage. RESULTS: Patency rate was 80% for uncoated and titanium-coated grafts. Quantitative angiography did not show any significant difference in lumen size between two groups. Morphometry revealed a significantly higher cellular coverage with CD31 positive endothelial cells for titanium-coated (84 +/- 19%) than uncoated grafts (48 +/- 26%, p<0.001). There was a non significant trend (p=0.112) towards increased neointimal proliferation in titanium-coated (94 +/- 61 micron2/micron) compared to uncoated grafts (60 +/- 57 micron2/micron). CONCLUSIONS: Patency rate in uncoated and titanium-coated ePTFE grafts is similar at one month. However, titanium coated grafts show a significant improvement in neo-endothelialization compared to uncoated grafts.


Assuntos
Prótese Vascular , Materiais Revestidos Biocompatíveis , Oclusão de Enxerto Vascular/prevenção & controle , Titânio , Animais , Implante de Prótese Vascular/instrumentação , Artérias Carótidas , Oclusão de Enxerto Vascular/patologia , Microscopia Eletrônica de Varredura , Politetrafluoretileno , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...