Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 200(10): 919-937, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38851183

RESUMO

The features of the glow curves of LiF:Mg,Ti are dependent on many parameters of irradiation, storage, ionisation density and readout. These are presented herein with emphasis on their complexity. Successful applications require some understanding of the great diversity of the glow curves. Glow curve analysis/deconvolution in order to better understand the mechanisms is a 'tricky business' even with Tm-Tstop analysis. In the theoretical framework of spatially correlated trapping and luminescent centres, a mechanism is described which simulates the behaviour of composite peak 5 at different cooling rates and following photon bleaching at 3.65 eV.


Assuntos
Fluoretos , Compostos de Lítio , Magnésio , Dosimetria Termoluminescente , Titânio , Compostos de Lítio/química , Magnésio/química , Fluoretos/efeitos da radiação , Fluoretos/química , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Titânio/química , Luminescência , Fótons
2.
Radiat Prot Dosimetry ; 200(4): 423-427, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38195760

RESUMO

The effect of natural rapid cooling and oven slow cooling on the precision of thermoluminescence measurements of LiF:Mg,Ti is investigated. Three separate series of measurements resulted in average precisions of 5.1 and 5.0%, respectively. However, the highest precision of 1.7% (1 SD) was achieved for an oven-cooled material.


Assuntos
Compostos de Lítio , Dosimetria Termoluminescente , Dosimetria Termoluminescente/métodos , Fluoretos , Titânio , Desenho de Equipamento
3.
Radiat Prot Dosimetry ; 199(6): 498-508, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-36856703

RESUMO

A seeming contradiction in the prediction of the spatially correlated trapping center/luminescent center model applied to LiF:Mg,Ti has been the linear/supralinear behavior of the dose response of glow peak 5a. In the TC/LC model, the localised electron-hole recombination, giving rise to glow peak 5a, is expected to result in an extended region of linear dose response. Deconvolution of the glow curves based on first order kinetic peak shapes results, however, in a dose response of peak 5a, which closely resembles the linear/supralinear dose response of peak 5. It is demonstrated herein that when general-order kinetics peak shapes are used for peak 5a, the analysis can result in a linear dose response of glow peak 5a up to dose levels as high as 30 Gy, well beyond the 1-Gy onset of supralinearity of peak 5. The extended linearity suggests a resolution of the contradiction.


Assuntos
Fluoretos , Dosimetria Termoluminescente , Doses de Radiação , Cinética , Dosimetria Termoluminescente/métodos , Compostos de Lítio , Titânio
4.
Radiat Prot Dosimetry ; 198(4): 222-228, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35313343

RESUMO

An experimental investigation into the possibility of dose-rate effects and wall scatter in the thermoluminescent response of LiF:Mg,Ti (TLD-100) was carried out. The investigation was motivated by theoretical simulations predicting the possible presence of dose-rate effects coupled with the lack of detailed experimental studies. The dose rate was varied by changing the source to sample distance, by the use of attenuators, sources of 137Cs of various activities, filtration and the construction of identical geometrical irradiators of Teflon and stainless steel. Four levels of dose in the linear dose response region were studied at 10-2 Gy, 1.5 × 10-2 Gy, 0.1 Gy and 0.5 Gy to avoid complications in interpretation due to supralinearity above 1 Gy. At the dose of 1.5 × 10-2 Gy, the dose rate was varied by five orders of magnitude from 4.9 × 10-3 Gy s-1 to 4.9 × 10-8 Gy s-1. At the other levels of dose, a one to two orders of magnitude in dose rate was achieved. Within the measurement uncertainty of 5-10%, no dose-rate effects were observed in any of the experimental measurements and no changes in the shape of the glow curve were observed. The maximum wall scatter effect (Teflon to stainless steel) was measured at ~8% within the experimental uncertainty and well below expectations. The results are encouraging with respect to the accurate and reproducible use of LiF:Mg,Ti under various experimental conditions of irradiation.


Assuntos
Compostos de Lítio , Dosimetria Termoluminescente , Radioisótopos de Césio , Fluoretos/efeitos da radiação , Compostos de Lítio/efeitos da radiação , Dosimetria Termoluminescente/métodos
5.
Radiat Prot Dosimetry ; 196(1-2): 53-59, 2021 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-34463339

RESUMO

The cooling rate to room temperature following the 400°C pre-irradiation anneal is known to affect the thermoluminescent properties of LiF:Mg,Ti (TLD-100) as a result of migration and clustering of defects during the cooling down process. In this investigation the dose response over an extended dose range from 0.01 to 7000 Gy in both naturally cooled and the much slower furnace-cooled samples has been measured. Glow curve deconvolution based on first-order kinetics is employed to extract the dose response of the various glow peaks. Of especial interest is the behaviour of glow peaks 4, 5a and 5 as a function of dose. The idea is to modify the supralinear dose response of peak 5 from 1 to 30 Gy to a linear behaviour. This dose range is important for clinical therapy and a linear dose response is of substantial advantage leading to both improved accuracy and precision.


Assuntos
Compostos de Lítio , Dosimetria Termoluminescente , Desenho de Equipamento , Fluoretos , Doses de Radiação
6.
Radiat Prot Dosimetry ; 192(2): 152-164, 2020 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-33415338

RESUMO

The Unified Interaction Model (UNIM) simulates the linear/supralinear dose response of the glow peaks of LiF:Mg,Ti (TLD-100) and other thermoluminescent materials and the dependence of the supralinearity on photon/electron energy. The UNIM is based on the radiation action of spatially correlated trapping centres (TCs) and luminescent centres (LCs), which results in localised (geminate) electron/hole recombination by quantum mechanical tunnelling. The linear dose response is mainly attributed to geminate recombination. UNIM simulations of the dose response of glow peak 5 in LiF:Mg,Ti following 500 and 8 keV electron/photon irradiation are discussed. In addition, simulations of postirradiation photo-excitation that redistribute the electrons and holes in the various TCs and LCs are demonstrated to extend the region of linear dose response and reduce the supralinearity. Experimental verification of dose-response linearity for levels of dose ≤30 Gy following both 3.65 and 5 eV photon excitation is presented.


Assuntos
Compostos de Lítio , Dosimetria Termoluminescente , Fluoretos , Fótons , Doses de Radiação
7.
Radiat Prot Dosimetry ; 179(2): 184-188, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29145646

RESUMO

The literature describing the experimental investigations of possible dose-rate effects in the thermoluminescence (TL) of LiF:Mg,Ti (Harshaw) is reviewed. The total lack of glow curve analysis, coupled with inclusion of all or part of the high temperature TL and absence of parallel measurements of possible dose-rate effects in the irradiation stage severely limit the scientific and technical level of the experiments. In addition, the experimental procedures are far from sufficient to warrant any conclusion concerning the presence or absence of dose-rate effects in the TL of LiF:Mg,Ti. This decision is contrary to the widely held belief that there are no dose-rate effects in the TL of LiF:Mg,Ti. In addition, the literature on dose-rate effects in the optical absorption (irradiation stage) of LiF is reviewed and is found contradictory. No dose-rate studies have been carried out on optical absorption in LiF:Mg,Ti. Kinetic simulations demonstrating the possibility, even likelihood, of dose-rate effects are also reviewed. Dose-rate effects are shown to be likely due to competition between excitation and recombination in the irradiation stage. Some other possible mechanisms involving multiple charge carrier trapping are suggested. Further definitive experiments are sorely needed, but the interested researcher should beware, it is not an easy task.


Assuntos
Relação Dose-Resposta à Radiação , Fluoretos/efeitos da radiação , Compostos de Lítio/efeitos da radiação , Compostos de Magnésio/efeitos da radiação , Titânio/efeitos da radiação , Doses de Radiação , Dosimetria Termoluminescente/métodos
8.
Radiat Prot Dosimetry ; 170(1-4): 407-11, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26715776

RESUMO

The first results of an in-depth evaluation of the practical potential of common household Israeli salt as a retrospective dosemeter in the event of a nuclear accident or terror attack are presented. Ten brands of salt were investigated with emphasis on four of the bestselling brands that constitute 76 % of the total consumer market. Eight of the ten brands show similar glow curves with two main glow peaks at maximum temperatures of ∼176°C and ∼225°C measured at a heating rate of 1°C s(-1) Chemical analysis of three major brands indicates substantial impurity levels of 200-500 ppm of Ca, K, Mg and S and significant differences of additional ppm trace impurities, which lead to an ∼50 % difference in the TL response of the three major brands. Fading in the dark is in significant but under room light is of the order of 35 % per day. The dose response is linear/supralinear with the threshold of supralinearity at ∼0.01 Gy reaching maximum value of ∼4 at 0.5-1 Gy for two of the major brands. The precision of repeated measurements is ∼10 % (1 SD), but the accuracy of dose assessment under field conditions requires further study.


Assuntos
Exposição Ambiental/análise , Dosímetros de Radiação , Radiometria/métodos , Cloreto de Sódio na Dieta , Cálcio/química , Calibragem , Radioisótopos de Césio , Relação Dose-Resposta à Radiação , Exposição Ambiental/prevenção & controle , Raios gama , Humanos , Israel , Luz , Magnésio/química , Teste de Materiais , Potássio/química , Doses de Radiação , Radiação Ionizante , Liberação Nociva de Radioativos , Estudos Retrospectivos , Enxofre/química , Temperatura
9.
J Mater Sci Mater Med ; 18(5): 865-70, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17211721

RESUMO

Photoluminescence, surface photovoltage spectroscopy and high-resolution characterization methods (Atomic Force Microscopy, Scanning Electron Microscopy, X-ray spectroscopy and DC conductivity) are applied to nanostructured Hydroxyapatite (HAp) bioceramics and allowed to study electron (hole) energy states spectra of the HAp and distinguish bulk and surface localized levels. The measured trap spectra show strong sensitivity to preliminary heat treatment of the ceramics. It is assumed that found deep electron (hole) charged states are responsible for high bioactivity of the HAp nanoceramics.


Assuntos
Materiais Biocompatíveis/química , Cerâmica/química , Durapatita/química , Eletroquímica , Técnicas In Vitro , Teste de Materiais , Microscopia de Força Atômica , Nanoestruturas/química , Análise Espectral , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...