Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 581-587, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568658

RESUMO

This study investigates the just-noticeable difference (JND) in luminance below the 0.050c d/m 2 threshold not covered by the DICOM standard in medical imaging displays. A total of 21 healthy young adults were tested using an ultralow-luminance liquid crystal display at a viewing distance of 46 cm. The optotype featured a 4 cycle/deg rectangular wave-like stripe. The average percentage of correct responses for JND indices between -18 and 0 was 70.8%. Using the extended JND based on the Barten model that matches the current JND definition, we confirmed the JND at a very low luminance of 0.0500c d/m 2 or less. These findings suggest the feasibility of further refining the gradation differences in medical imaging displays.


Assuntos
Diagnóstico por Imagem , Adulto Jovem , Humanos , Limiar Diferencial
2.
Int J Mol Sci ; 25(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38542305

RESUMO

We tested five chemically and metabolically stable prostaglandin (PG) receptor agonists in a mouse model of dexamethasone-induced ocular hypertension (OHT). Whilst all compounds significantly (p < 0.05, ANOVA) lowered intraocular pressure (IOP) after twice-daily bilateral topical ocular dosing (5 µg/dose) over three weeks, the time course and magnitude of the responses varied. The onset of action of NS-304 (IP-PG receptor agonist) and rivenprost (EP4-PG receptor agonist) was slower than that of misoprostol (mixed EP2/EP3/EP4-PG receptor agonist), PF-04217329 (EP2-PG receptor agonist), and butaprost (EP2-PG receptor agonist). The rank order of IOP-lowering efficacies aligned with the onset of actions of these compounds. Peak IOP reductions relative to vehicle controls were as follows: misoprostol (74.52%) = PF-04217329 (74.32%) > butaprost (65.2%) > rivenprost (58.4%) > NS-304 (55.3%). A literature survey indicated that few previously evaluated compounds (e.g., latanoprost, timolol, pilocarpine, brimonidine, dorzolamide, cromakalim analog (CKLP1), losartan, tissue plasminogen activator, trans-resveratrol, sodium 4-phenyl acetic acid, etc.) in various animal models of steroid-induced OHT were able to match the effectiveness of misoprostol, PF-04217329 or butaprost. Since a common feature of the latter compounds is their relatively high affinity and potency at the EP2-PG receptor sub-type, which activates the production of intracellular cAMP in target cells, our studies suggest that drugs selective for the EP2-PG receptor may be suited to treat corticosteroid-induced OHT.


Assuntos
Acetamidas , Acetatos , Misoprostol , Hipertensão Ocular , Pirazinas , Sulfonamidas , Animais , Camundongos , Misoprostol/farmacologia , Misoprostol/uso terapêutico , Ativador de Plasminogênio Tecidual , Hipertensão Ocular/induzido quimicamente , Hipertensão Ocular/tratamento farmacológico , Receptores de Prostaglandina , Receptores de Prostaglandina E Subtipo EP4 , Esteroides
3.
Micromachines (Basel) ; 15(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38398942

RESUMO

Stent retrievers are medical devices that are designed to physically remove blood clots from within the blood vessels of the brain. This paper focuses on microfabricated nitinol (nickel-titanium alloy) stent retrievers, which feature micro-patterns on their surface to enhance the effectiveness of mechanical thrombectomy. A thick film of nitinol, which was 20 µm in thickness, was sputtered onto a substrate with a micro-patterned surface, using electroplated copper as the sacrificial layer. The nitinol film was released from the substrate and then thermally treated while folded into a cylindrical shape. In vitro experiments with pig blood clots demonstrated that the micro-patterns on the surface improved the efficacy of blood clot retrieval.

4.
Jpn J Radiol ; 42(6): 599-611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38351253

RESUMO

PURPOSE: Liver and pancreatic fibrosis is associated with diabetes mellitus (DM), and liver fibrosis is associated with pancreatic fibrosis. This study aimed to investigate the relationship between the hepatic and pancreatic extracellular volume fractions (fECVs), which correlate with tissue fibrosis, and their relationships with DM and pre-DM (pDM). MATERIAL AND METHODS: We included 100 consecutive patients with known or suspected liver and/or pancreatic diseases who underwent contrast-enhanced CT. Patients were classified as nondiabetes, pDM, and DM with hemoglobin A1c (HbA1c) levels of < 5.7%, 5.7%-6.5%, and ≥ 6.5% or fasting plasma glucose (FPG) levels of < 100, 100-125 mg/dL, and ≥ 126 mg/dL, respectively. Subtraction images between unenhanced and equilibrium-phase images were prepared. The liver and the pancreas were automatically extracted using a high-speed, three-dimensional image analysis system, and their respective mean CT values were calculated. The enhancement degree of the aorta (Δaorta) was measured. fECV was calculated using the following equation: fECV = (100 - hematocrit) * Δliver or pancreas/Δaorta. Differences were investigated in hepatic and pancreatic fECVs among the three groups, and the correlation between each two in hepatic fECV, pancreatic fECV, and HbA1c was determined. RESULTS: The pancreatic fECV, which was positively correlated with the hepatic fECV and HbA1c (r = 0.51, P < 0.001, and r = 0.51, P < 0.001, respectively), significantly differed among the three groups (P < 0.001) and was significantly greater in DM than in pDM or nondiabetes and in pDM with nondiabetes (P < 0.001). Hepatic fECV was significantly greater in DM than in nondiabetes (P < 0.05). CONCLUSION: The pancreatic fECV and pDM/DM are closely related.


Assuntos
Meios de Contraste , Fígado , Estado Pré-Diabético , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Fígado/diagnóstico por imagem , Estado Pré-Diabético/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Adulto , Diabetes Mellitus/diagnóstico por imagem , Idoso de 80 Anos ou mais , Imageamento Tridimensional/métodos , Cirrose Hepática/diagnóstico por imagem , Estudos Retrospectivos
5.
Magn Reson Med Sci ; 23(2): 214-224, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36990740

RESUMO

PURPOSE: To compare the effects of deep learning reconstruction (DLR) on respiratory-triggered T2-weighted MRI of the liver between single-shot fast spin-echo (SSFSE) and fast spin-echo (FSE) sequences. METHODS: Respiratory-triggered fat-suppressed liver T2-weighted MRI was obtained with the FSE and SSFSE sequences at the same spatial resolution in 55 patients. Conventional reconstruction (CR) and DLR were applied to each sequence, and the SNR and liver-to-lesion contrast were measured on FSE-CR, FSE-DLR, SSFSE-CR, and SSFSE-DLR images. Image quality was independently assessed by three radiologists. The results of the qualitative and quantitative analyses were compared among the four types of images using repeated-measures analysis of variance or Friedman's test for normally and non-normally distributed data, respectively, and a visual grading characteristics (VGC) analysis was performed to evaluate the image quality improvement by DLR on the FSE and SSFSE sequences. RESULTS: The liver SNR was lowest on SSFSE-CR and highest on FSE-DLR and SSFSE-DLR (P < 0.01). The liver-to-lesion contrast did not differ significantly among the four types of images. Qualitatively, noise scores were worst on SSFSE-CR but best on SSFSE-DLR because DLR significantly reduced noise (P < 0.01). In contrast, artifact scores were worst both on FSE-CR and FSE-DLR (P < 0.01) because DLR did not reduce the artifacts. Lesion conspicuity was significantly improved by DLR compared with CR in the SSFSE (P < 0.01) but not in FSE sequences for all readers. Overall image quality was significantly improved by DLR compared with CR for all readers in the SSFSE (P < 0.01) but only one reader in the FSE (P < 0.01). The mean area under the VGC curve values for the FSE-DLR and SSFSE-DLR sequences were 0.65 and 0.94, respectively. CONCLUSION: In liver T2-weighted MRI, DLR produced more marked improvements in image quality in SSFSE than in FSE.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/patologia , Artefatos
6.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975732

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. MATERIALS AND METHODS: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. RESULTS: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 ± 2.9 vs 23.3 ± 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 ± 0.0 vs 9.7 ± 0.5, 11.0 ± 2.2, and 12.3 ± 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. CONCLUSIONS: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.

7.
Magn Reson Med Sci ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37899224

RESUMO

PURPOSE: To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI. METHODS: Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences. RESULTS: The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences. CONCLUSION: High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.

8.
J Comput Assist Tomogr ; 47(5): 698-703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37707398

RESUMO

OBJECTIVE: To evaluate the image quality and lesion detectability of pancreatic phase thin-slice computed tomography (CT) images reconstructed with a deep learning-based reconstruction (DLR) algorithm compared with filtered-back projection (FBP) and hybrid iterative reconstruction (IR) algorithms. METHODS: Fifty-three patients who underwent dynamic contrast-enhanced CT including pancreatic phase were enrolled in this retrospective study. Pancreatic phase thin-slice (0.625 mm) images were reconstructed with each FBP, hybrid IR, and DLR. Objective image quality and signal-to-noise ratio of the pancreatic parenchyma, and contrast-to-noise ratio of pancreatic lesions were compared between the 3 reconstruction algorithms. Two radiologists independently assessed the image quality of all images. The diagnostic performance for the detection of pancreatic lesions was compared among the reconstruction algorithms using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: Deep learning-based reconstruction resulted in significantly lower image noise and higher signal-to-noise ratio and contrast-to-noise ratio than hybrid IR and FBP ( P < 0.001). Deep learning-based reconstruction also yielded significantly higher visual scores than hybrid IR and FBP ( P < 0.01). The diagnostic performance of DLR for detecting pancreatic lesions was highest for both readers, although a significant difference was found only between DLR and FBP in one reader ( P = 0.02). CONCLUSIONS: Deep learning-based reconstruction showed improved objective and subjective image quality of pancreatic phase thin-slice CT relative to other reconstruction algorithms and has potential for improving lesion detectability.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagem
9.
J Med Ultrason (2001) ; 50(3): 441-446, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37209165

RESUMO

PURPOSE: This study sought to clarify the positional relationship between the Achilles tendon and sural nerve using ultrasound. METHODS: We studied 176 legs in 88 healthy volunteers. The positional relationship between the Achilles tendon and sural nerve at heights of 2, 4, 6, 8, 10, and 12 cm proximal from the calcaneus' proximal margin was investigated by distance and depth. Setting the X-axis (left/right) as the horizontal axis and Y-axis (depth) as the vertical axis against ultrasound images, we investigated the distance between the lateral margin of the Achilles tendon to the midpoint of the sural nerve on the X-axis. The Y-axis was split into four zones: the part behind the center of the Achilles tendon (AS), the part in front of the center of the Achilles tendon (AD), the part behind the Achilles tendon (S), and the part in front (D). We investigated the zones through which the sural nerve passed. We also studied any significant differences between the sexes and left/right legs. RESULTS: The mean distance on the X-axis was closest at 6 cm, with 1.1 ± 5.0 mm between them. The sural nerve's position on the Y-axis was such that at positions more proximal than 8 cm, the sural nerve ran through zone S in most legs and moved to zone AS through heights 2-6 cm. No parameters showed significant differences between the sexes or left/right legs. CONCLUSION: We presented the positional relationship between the Achilles tendon and sural nerve and suggested some measures to prevent nerve injury during surgery.


Assuntos
Tendão do Calcâneo , Humanos , Tendão do Calcâneo/diagnóstico por imagem , Nervo Sural/diagnóstico por imagem , Nervo Sural/lesões , Perna (Membro) , Ultrassonografia/métodos , Voluntários Saudáveis
10.
Radiol Med ; 128(6): 629-643, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37120661

RESUMO

OBJECTIVES: To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS: MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS: Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION: MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.


Assuntos
Alprostadil , Neoplasias do Endométrio , Feminino , Humanos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia
12.
J Clin Med ; 11(19)2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36233521

RESUMO

Purpose: To compare the accuracy of liver fibrosis staging with MR elastography and of staging with extracellular volume fraction (fECV) analysis using contrast-enhanced CT. Methods: This retrospective study included 60 patients who underwent both MR elastography and contrast-enhanced CT before liver surgery between October 2013 and July 2020. Two radiologists independently measured liver stiffness of MR elastography and fECV of CT images. Accuracy for liver fibrosis staging was assessed using receiver operating characteristic (ROC) analysis. Correlations between liver stiffness or fECV and liver fibrosis were also evaluated by means of the Spearman rank correlation coefficient. Results: The areas under the ROC curves for MR elastography for each stage differentiation of ≥F1 (0.85, 0.82 for the two radiologists), ≥F2 (0.88, 0.89), ≥F3 (0.87, 0.86), and F4 (0.84, 0.83) were greater than those for fECV analysis with CT (0.64, p = 0.06, 0.69, p = 0.2; 0.62, p < 0.005, 0.63, p < 0.005; 0.62, p < 0.005, 0.62, p < 0.01; and 0.70, p = 0.08, 0.71, p = 0.2, respectively). The correlation coefficients between liver stiffness and liver fibrosis in A0 (0.67, 0.69 for the two radiologists), A1 (0.64, 0.66) and A2 group (0.58, 0.51) were significantly higher than those between fECV and liver fibrosis (0.28, 0.30; 0.27, 0.31; and 0.23, 0.07; p < 0.05 for all comparisons). Conclusion: MR elastography allows for more accurate liver fibrosis staging compared with fECV analysis with CT. In addition, MR elastography may be less affected than fECV analysis by the inflammatory condition.

13.
JACC Case Rep ; 4(18): 1224, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36213891
14.
Radiographics ; 42(7): 2095-2111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36083804

RESUMO

Borderline epithelial ovarian tumors are a distinct pathologic entity characterized by increased epithelial proliferation and nuclear atypia, but without frank stromal invasion. Borderline tumor (BT) is now considered to represent an intermediate phase in the stepwise progression from benign to malignant ovarian epithelial tumor. Since BTs commonly manifest at early stages in women of reproductive age and are associated with a good prognosis, making the correct diagnosis is important in determining whether a patient is a candidate for fertility-sparing surgery. There are six histologic BT subtypes (serous, mucinous, seromucinous, endometrioid, clear cell, and Brenner), and each has different MRI features, reflecting their unique histologic architectures. Radiologists should be aware of the MRI features that can suggest BTs. These features include a hyperintense papillary architecture with hypointense internal branching, which can be observed with serous and seromucinous BTs on T2-weighted images; aggregates of microcysts that have hypointensity on T2-weighted images and reticular enhancement on contrast-enhanced T2-weighted images, which can be seen with mucinous BTs; and moderately high signal intensity on diffusion-weighted images along with relatively high apparent diffusion coefficient values, which can be observed regardless of the histologic subtype. Nevertheless, because the imaging features of BTs overlap with those of many benign lesions (eg, cystadenoma and cystadenofibroma, decidualized endometriosis, and polypoid endometriosis) and malignant tumors (ovarian cancers and metastases), histologic confirmation is required for the final diagnosis. Special emphasis is placed on the MRI features of BTs, pathologic correlation, and the challenges related to diagnosis. ©RSNA, 2022.


Assuntos
Carcinoma , Endometriose , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/patologia , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos
15.
Eur J Radiol ; 156: 110522, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36113381

RESUMO

PURPOSE: This study aimed to assess the relationship between pancreatic fibrosis measured by the extracellular volume fraction (ECV) using contrast-enhanced computed tomography (CT) and the histologic pancreatic fibrosis fraction and investigate the relationship between pancreatic fibrosis and pancreatic cancer. METHOD: The study included 88 consecutive patients (48 males, 40 females; median age, 69 years; range, 17-89 years); 47 had pancreatic cancer, and 41 had other diseases. Fifty-two cases were evaluated pathologically for pancreatic fibrosis. The histologic pancreatic fibrosis fraction was quantified using image analysis software in nontumorous pancreatic tissue at the resection stump using 2-µm-thick Azan-stained slides. Two board-certified radiologists measured ECV in the pancreatic parenchyma at an estimated transection line. The correlation between histologic pancreatic fibrosis fraction and ECV was investigated, and whether the ECV value could be used as a biomarker for pancreatic cancer was investigated. RESULTS: The histologic pancreatic fibrosis fraction was significantly correlated with the ECV (r = 0.64, P < 0.01). Pancreatic fibrosis evaluated by ECV was higher in pancreatic cancer patients than in other patients (P < 0.01). On receiver-operating characteristic curve analysis, the ECV had good diagnostic accuracy for the development of pancreatic cancer (cut-off value 32.8%; sensitivity 61.0%, specificity 85.1%). ECV was identified on multivariate analysis as an independent risk factor for pancreatic cancer (odds ratio 1.16; P < 0.01). CONCLUSIONS: Extracellular volume fraction was strongly related to the histologic pancreatic fibrosis fraction, which was independently associated with pancreatic cancer. Thus, extracellular volume fraction is an imaging biomarker that reflects the progression of pancreatic fibrosis and may potentially help predict the development of pancreatic cancer, although further investigation will be needed.

16.
Sci Rep ; 12(1): 12176, 2022 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-35842451

RESUMO

Virtual thin-slice (VTS) technique is a generative adversarial network-based algorithm that can generate virtual 1-mm-thick CT images from images of 3-10-mm thickness. We evaluated the performance of VTS technique for assessment of the spine. VTS was applied to 4-mm-thick CT images of 73 patients, and the visibility of intervertebral spaces was evaluated on the 4-mm-thick and VTS images. The heights of vertebrae measured on sagittal images reconstructed from the 4-mm-thick images and VTS images were compared with those measured on images reconstructed from 1-mm-thick images. Diagnostic performance for the detection of compression fractures was also compared. The intervertebral spaces were significantly more visible on the VTS images than on the 4-mm-thick images (P < 0.001). The absolute value of the measured difference in mean vertebral height between the VTS and 1-mm-thick images was smaller than that between the 4-mm-thick and 1-mm-thick images (P < 0.01-0.54). The diagnostic performance of the VTS images for detecting compression fracture was significantly lower than that of the 4-mm-thick images for one reader (P = 0.02). VTS technique enabled the identification of each vertebral body, and enabled accurate measurement of vertebral height. However, this technique is not suitable for diagnosing compression fractures.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Algoritmos , Fraturas por Compressão/diagnóstico por imagem , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
17.
Eur J Radiol ; 150: 110271, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334243

RESUMO

PURPOSE: A newly developed Adaptive Image Receive (AIR) coil is designed to be more flexible to conform to the human body habitus, and may improve image quality by reducing the distance between the coil element and the imaging subject. This study evaluated the AIR coil's usefulness for liver MR imaging at 3.0 T in comparison with that of a conventional coil retrospectively. METHOD: The study population comprised 50 consecutive patients, who underwent follow-up liver MR examinations with a 3.0-T MR system using both an AIR coil and a conventional coil to evaluate hepatocellular carcinoma. Three-dimensional fat-suppressed T1-weighted gradient-echo images before and after injection of an MRI contrast agent, T2-weighted single-shot fast spin-echo (SSFSE) images, and diffusion-weighted (DW) images obtained with the AIR coil were compared with corresponding images obtained with the conventional coil. One radiologist measured signal-to-noise ratios (SNRs), while two other radiologists used a 3-point scale to independently assess subjective image noise, artifacts, signal uniformity, and overall image quality. RESULTS: SNRs for the AIR coil were significantly higher than those for the conventional coil (P <.05). Subjective image noise for the AIR coil on pre- and postcontrast T1-weighted and DW images was lower than for the conventional coil for both readers (P <.05). Overall image quality on pre- and postcontrast T1-weighted and DW images for the AIR coil was better than that for the conventional coil for at least one reader (P <.05). CONCLUSIONS: In comparison with the conventional coil, AIR coil improved SNR and image quality of liver MR imaging.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tecnologia
18.
Anticancer Res ; 42(3): 1555-1562, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35220252

RESUMO

BACKGROUND/AIM: The management of soft-tissue tumors of 2-5 cm is not specified. We investigated the management of these cases. PATIENTS AND METHODS: Among 105 cases with soft-tissue tumors from 2014 to 2021, 38 with tumors of 2-5 cm were retrospectively reviewed. The clinical characteristics, diagnosis, and management were investigated. RESULTS: The study population included 14 males and 24 females (mean age=57 years). Common histological diagnoses included lipoma, epidermal cyst, and hemangioma as benign tumors, and leiomyosarcoma (n=2) and metastatic soft-tissue carcinoma (n=1) as malignant tumors. Magnetic resonance imaging, needle and excisional biopsy were performed in 35, 19 and 19 cases, respectively. The mean follow-up period was 7 months. No recurrence was observed. CONCLUSION: Malignancy exists, even in soft-tissue tumors of 2-5 cm (3/38; 8%). To avoid unplanned excision, needle biopsy should be considered for cases with magnetic resonance imaging abnormalities.


Assuntos
Neoplasias de Tecidos Moles/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Criança , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/patologia , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Procedimentos Desnecessários , Adulto Jovem
19.
J Clin Med ; 10(19)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34640568

RESUMO

Background: Strong correlation has been reported between tissue water diffusivity and tissue elasticity in the liver. The purpose of this study is to explore the capability of diffusion-based virtual MR elastography (VMRE) in the characterization of liver tumors by extending beyond liver fibrosis assessments. Methods: Fifty-four patients (56 liver tumors: hepatocellular carcinoma (HCC), 31; metastases, 25) who underwent MRE, diffusion-weighted imaging (DWI) (b: 0, 800 s/mm2), and VMRE (b: 200, 1500 s/mm2) were enrolled. The MRE shear modulus (µMRE), apparent diffusion coefficient (ADC), and shifted ADC (sADC) were obtained. Virtual stiffness (µdiff) was estimated from the relationship between µMRE and sADC. A linear discriminant analysis combining VMRE and MRE to classify HCC and metastases was performed in a training cohort (thirty-two patients) to estimate a classifier (C), and evaluate its accuracy in a testing cohort (twenty-two patients). Pearson's correlations between µMRE, sADC, and ADC were evaluated. In addition to the discriminant analysis, a receiver operating characteristic (ROC) curve was used to assess the discrimination capability between HCC and metastases. Results: The correlations between µMRE and sADC were significant for liver, HCC, and metastases (r = 0.91, 0.68, 0.71; all p < 0.05). Those between µMRE and ADC were weaker and significant only for metastases (r = 0.17, 0.20, 0.55). µdiff values were not significantly different between HCC and metastases (p = 0.56). Areas under the curves (AUC) to differentiate HCC from metastases were as follows: VMRE, 0.46; MRE alone, 0.89; MRE + VMRE, 0.96. The classifier C also provided better performance than MRE alone, in terms of sensitivity (100 vs. 93.5%, respectively) and specificity (92 vs. 76%, respectively, p = 0.046). Conclusions: The correlation between sADC and µMRE was strong both in the liver and in tumors. However, VMRE alone could not classify HCC and metastases. The combination of MRE and VMRE, however, allowed discriminant performance between HCC and metastases.

20.
Micromachines (Basel) ; 12(8)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34442614

RESUMO

Hemofiltration removes water and small molecules from the blood via nanoporous filtering membranes. This paper discusses a pump-free hemofiltration device driven by the pressure difference between the artery and the vein. In the design of the filtering device, oncotic pressure needs to be taken into consideration. Transmembrane pressure (TMP) determines the amount and direction of hemofiltration, which is calculated by subtracting the oncotic pressure from the blood pressure. Blood pressure decreases as the channels progress from the inlet to the outlet, while oncotic pressure increases slightly since no protein is removed from the blood to the filtrate in hemofiltration. When TMP is negative, the filtrate returns to the blood, i.e., backfiltration takes place. A small region of the device with negative TMP would thus result in a small amount of or even zero filtrates. First, we investigated this phenomenon using in vitro experiments. We then designed a hemofiltration system taking backfiltration into consideration. We divided the device into two parts. In the first part, the device has channels for the blood and filtrate with a nanoporous membrane. In the second part, the device does not have channels for filtration. This design ensures TMP is always positive in the first part and prevents backfiltration. The concept was verified using in vitro experiments and ex vivo experiments in beagle dogs. Given the simplicity of the device without pumps or electrical components, the proposed pump-free hemofiltration device may prove useful for either implantable or wearable hemofiltration.