Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Transfusion ; 53(6): 1257-65, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23002996

RESUMO

BACKGROUND: The clinical significance of anti-Trypanosoma cruzi low-level reactive samples is incompletely understood. Polymerase chain reaction (PCR)-positive rates and antibody levels among seropositive blood donors in three countries are described. STUDY DESIGN AND METHODS: Follow-up samples were collected from T. cruzi-seropositive donors from 2008 through 2010 in the United States (n = 195) and Honduras (n = 58). Also 143 samples from Brazil in 1996 to 2002, originally positive by three serologic assays, were available and paired with contemporary follow-up samples from these donors. All samples were retested with Ortho enzyme-linked immunosorbent assay (ELISA). PCR assays were performed on coded sample panels by two laboratories (Blood Systems Research Institute [BSRI] and American Red Cross Holland Laboratory [ARC]) that amplified kinetoplast minicircle DNA sequences of T. cruzi. RESULTS: PCR testing at BSRI yielded slightly higher overall sensitivity and specificity (33 and 98%) compared with those at the ARC (28 and 94%). Among seropositive donors, PCR-positive rates varied by country (p < 0.0001) for the BSRI laboratory: Brazil (57%), Honduras (32%), and the United States (14%). ELISA signal-to-cutoff ratios (S/CO) were significantly higher for PCR-positive compared to PCR-negative donors (p < 0.05 for all comparisons). Additionally, PCR-negative Brazilian donors exhibited greater frequencies of antibody decline over time versus PCR-positive donors (p = 0.003). CONCLUSION: For all three countries, persistent DNA positivity correlated with higher ELISA S/CO values, suggesting that high-level seroreactivity reflects chronic parasitemia. Significant S/CO declines in 10% of the PCR-negative Brazilian donors may indicate seroreversion after parasite clearance in the absence of treatment.


Assuntos
Anticorpos Antiprotozoários/sangue , Doadores de Sangue/estatística & dados numéricos , Segurança do Sangue/estatística & dados numéricos , Doença de Chagas , DNA de Protozoário/sangue , Trypanosoma cruzi/isolamento & purificação , Brasil/epidemiologia , Doença de Chagas/sangue , Doença de Chagas/epidemiologia , Doença de Chagas/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Seguimentos , Honduras/epidemiologia , Humanos , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Trypanosoma cruzi/genética , Trypanosoma cruzi/imunologia , Estados Unidos/epidemiologia
3.
Transfusion ; 49(6): 1076-82, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19290995

RESUMO

BACKGROUND: Evaluation of commercially available test kits for Chagas disease for use in blood bank screening is difficult due to a lack of large and well-characterized specimen panels. This study presents a collaborative effort of Latin American blood centers and the World Health Organization (WHO) to establish such a panel. STUDY DESIGN: A total of 437 specimens, from 10 countries were collected and sent to the WHO Collaborating Center in São Paulo and used to evaluate 19 screening assays during 2001 through 2005. Specimens were assigned a positive or negative status based on concordant results in at least three of the four confirmatory assays (indirect immunofluorescence, Western blot, radioimmunoprecipitation assay, and recombinant immunoblot). RESULTS: Of the 437 specimens, 168 (39%) were characterized as positive, 262 (61%) were characterized as negative, and 7 (2%) were judged inconclusive and excluded from the analysis. Sensitivity and specificity varied considerably: 88 to 100 and 60 to 100 percent, respectively. Overall, enzyme immunoassays (EIAs) performed better than the other screening assays. Four EIAs had both parameters higher than 99 percent. Of the four confirmatory assays, only the RIPA gave a 100 percent agreement with the final serologic status of the specimens. CONCLUSION: The sensitivities and specificities of at least four of the commercially available EIAs for Chagas disease are probably high enough to justify their use for single-assay screening of blood donations. Our data suggest that the majority of commercially available indirect hemagglutination assays should not be used for blood donor screening and that the RIPA could be considered a gold standard for evaluating the performance of other assays.


Assuntos
Doença de Chagas/diagnóstico , Doença de Chagas/imunologia , Testes de Hemaglutinação , Humanos , Técnicas Imunoenzimáticas , Ensaio de Radioimunoprecipitação , Sensibilidade e Especificidade , Testes Sorológicos , Organização Mundial da Saúde
4.
Rev Panam Salud Publica ; 13(2-3): 91-102, 2003.
Artigo em Espanhol | MEDLINE | ID: mdl-12751462

RESUMO

OBJECTIVE: To evaluate the quality of serological screening of blood donors in five groups of blood banks in Latin America that participated over the 1997-2000 period in an external serology control project developed with support from the Pan American Health Organization (PAHO). METHODS: With assistance from PAHO, the Serology Authority of the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo), of São Paulo, Brazil, carried out the external quality control project and served as its "organizing center" (OC). The OC developed five external serology quality control "programs" (ESQCPs), or external evaluation activities, for the respective groups of participating blood banks. There was one ESQCP each in 1997, 1999, and 2000, and there were two in 1998. In these five programs, the number of participating blood banks ranged from 13 to 21, and the number of countries ranged from 11 to 16. In each program, the OC used a set of 24 blinded sera samples with different reactivities for the various infectious agents for which screening is obligatory in Brazil. Each participating institution in each program received a sera set, to be processed using that institution's standard screening procedures. After returning its results to the OC, each participant received an answer key for the sera set, to be used in evaluating its own performance. All the individual results were kept strictly confidential. At the end of each program, the OC prepared and sent to all the participants a final report that contained information on the overall results from that program. RESULTS: An analysis of the five programs showed that there was a lack of homogeneity among the countries with respect to the strategies and the parameters used in screening blood donors. Few laboratories screened for human T-cell-lymphotropic virus (beginning with the 1997 program, the respective rates were 17%, 27%, 35%, 39%, and 45%). Rates of screening were also low for antibodies to the hepatitis B core antigen (again, beginning with the 1997 program, the rates were 42%, 27%, 39%, 50%, and 60%). There were also important differences with respect to which tests and which combinations of tests were used, making it hard to compare the types of screening done. In the five programs, with the various tests used, the overall rate of false positive results fluctuated around 2%. The highest false positive rate for any of the tests, 4.6%, was for antibodies against the hepatitis C virus. The lowest false positive rate, 0.4%, was for antibodies against Trypanosoma cruzi. CONCLUSIONS: These results show the need for PAHO to continue using these external quality control programs as well as other activities in order to strengthen the procedures for serological screening blood banks in Latin America, until there is more uniformity in the procedures that the countries use.


Assuntos
Bancos de Sangue/normas , Doadores de Sangue/classificação , Programas de Rastreamento/normas , Controle de Qualidade , Testes Sorológicos/normas , Bancos de Sangue/organização & administração , Ensaio de Imunoadsorção Enzimática , Humanos , Laboratórios/normas , América Latina , Organização Pan-Americana da Saúde , Avaliação de Programas e Projetos de Saúde , Apoio à Pesquisa como Assunto
5.
Rev Panam Salud Publica ; 13(2-3): 111-6, 2003.
Artigo em Português | MEDLINE | ID: mdl-12744786

RESUMO

OBJECTIVES: To analyze the changes in the proportion of blood units discarded from 1991 through 2001 at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo), which is the largest blood bank in Latin America, and to determine the prevalence of infectious diseases among donors at the Blood Center in November 2001. METHODS: We compiled data concerning the discarding of blood units due to the presence of serological markers for communicable diseases at the Blood Center during the period from 1991 through 2001. To determine the prevalence of infectious diseases, 9 942 screened samples were analyzed in November 2001; all reactive samples underwent confirmatory tests. RESULTS: Over the study period there was a significant decrease in the percentage of units discarded, from 20% in 1991 to 9% in 2001. In November 2001 the prevalence of infectious diseases among donors was: 0.04% for human immunodeficiency virus (HIV), 0.21% for hepatitis C virus (HCV), 0.06% for human T-lymphotropic virus (HTLV), 0.14% for Chagas' disease, and 1.10% for syphilis. For hepatitis B virus, the prevalences found were: 0.14% for anti-HBc and HBsAg, 1.68% for anti-HBc and anti-HBs, and 1.67% for isolated anti-HBc. CONCLUSIONS: The decrease in the discarding of blood units and in infectious diseases among donors at the Blood Center of São Paulo reflects the increase in the Center's percentage of repeat donors.


Assuntos
Bancos de Sangue/organização & administração , Doadores de Sangue , Doenças Transmissíveis/epidemiologia , Resíduos de Serviços de Saúde , Bancos de Sangue/normas , Transfusão de Sangue/normas , Brasil/epidemiologia , Humanos , Prevalência
6.
Rev Panam Salud Publica ; 13(2-3): 172-5, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12744793

RESUMO

OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV) concomitantly using two different enzyme immunoassay (EIA) tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo), which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB) test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4%) had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58%) did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great majority of HIV-positive donors have already seroconverted and will be detected using only a single EIA screening test. Only persons who are going through the process of seroconversion may be missed by using a single EIA test and detected using two EIAs for screening. To screen out these individuals and decrease the residual risk of HIV transmission from the blood donated in our center, the use of other techniques, such as nucleic acid testing (NAT) or a p24 antigen assay, would be more effective.


Assuntos
Sorodiagnóstico da AIDS/normas , Bancos de Sangue/normas , Soropositividade para HIV/epidemiologia , Programas de Rastreamento/normas , Sorodiagnóstico da AIDS/métodos , Bancos de Sangue/legislação & jurisprudência , Doadores de Sangue/classificação , Brasil/epidemiologia , Soropositividade para HIV/diagnóstico , Humanos , Técnicas Imunoenzimáticas/normas , Técnicas Imunoenzimáticas/estatística & dados numéricos , Programas Obrigatórios , Programas de Rastreamento/legislação & jurisprudência , Avaliação de Programas e Projetos de Saúde , Controle de Qualidade
7.
Rev. panam. salud pública ; 13(2/3): 91-102, Feb.-Mar. 2003. tab, graf
Artigo em Espanhol | LILACS | ID: lil-346095

RESUMO

OBJETIVOS: Con el apoyo de la Organización Panamericana de la Salud (OPS), desarrollamos entre 1997 y 2000 cinco programas de control externo de la calidad en serología (PCECS) en los que participaron entre 13 y 21 bancos de sangre de 11 a 16 países de América Latina. El objetivo fue evaluar el desempeño de los bancos de sangre con respecto al tamizaje serológico realizado en donantes de sangre. MÉTODOS: Como herramienta de trabajo utilizamos conjuntos de 24 muestras de sueros anónimos con reactividades variables para los parámetros de uso obligatorio en el tamizaje serológico de donantes de sangre en Brasil. En cada PCECS enviamos un multipanel a cada institución participante para que lo procesara en las mismas condiciones de su rutina de tamizaje. Cada participante recibió la clave del multipanel para autoevaluación, después de haber devuelto los resultados obtenidos en su laboratorio. Se mantuvo siempre la más estricta confidencialidad sobre los resultados obtenidos individualmente. Al terminar de cada programa, el Centro Organizador (Superintendencia de Serología de la Fundaçäo Pró-Sangue/Hemocentro de Säo Paulo) elaboró un informe final que contenía toda la información obtenida en el programa y que fue enviado a los participantes. RESULTADOS: En el análisis de los cinco PCECS se observó falta de homogeneidad entre los países con respecto a las estrategias y a los parámetros utilizados en el tamizaje de donantes de sangre. Pocos laboratorios practicaron el tamizaje de los virus linfotrópico de células T humanas (HTLV) (17 por ciento, 27 por ciento, 35 por ciento, 39 por ciento y 45 por ciento, respectivamente y en orden creciente para los cinco PCECS) y de anticuerpos contra el antígeno nuclear del virus de la hepatitis B (anti-HBc) (42 por ciento, 27 por ciento, 39 por ciento, 50 por ciento y 60 por ciento). También se observaron diferencias importantes en cuanto a las pruebas o combinaciones de pruebas utilizadas, lo cual puede dificultar el estudio comparativo de los tipos de tamizaje. El número total de resultados positivos falsos osciló alrededor del 2 por ciento, correspondiendo el mayor valor al tamizaje de anticuerpos contra el virus de la hepatatis C (anti-VHC) (4,6 por ciento) y el menor a anti-Trypanosoma cruzi (0,4 por ciento). CONCLUSIONES: Los resultados obtenidos en este trabajo demuestran la necesidad de continuar las acciones de la OPS en América Latina para reforzar los procedimientos de...


Assuntos
Humanos , Bancos de Sangue/normas , Doadores de Sangue/classificação , Programas de Rastreamento/normas , Controle de Qualidade , Testes Sorológicos/normas , Bancos de Sangue/organização & administração , Ensaio de Imunoadsorção Enzimática , Laboratórios/normas , América Latina , Organização Pan-Americana da Saúde , Avaliação de Programas e Projetos de Saúde , Apoio à Pesquisa como Assunto
8.
Rev. panam. salud pública ; 13(2/3): 111-116, Feb.-Mar. 2003. tab
Artigo em Português | LILACS | ID: lil-346097

RESUMO

OBJETIVO: Analisar a evoluçäo, de 1991 a 2001, do descarte sorológico na Fundaçäo Pró-Sangue/Hemocentro de Säo Paulo, o maior banco de sangue da América Latina, e verificar a prevalência de doenças infecciosas entre doadores dessa instituiçäo no ano de 2001. MÉTODOS: Foram compilados os dados de descarte sorológico relativos aos anos de 1991 a 2001. Para determinar a prevalência de doenças infecciosas, foram analisadas 9 942 amostras triadas em novembro de 2001, sendo as amostras reativas submetidas a testes confirmatórios. RESULTADOS: Foi encontrada uma diminuiçäo percentual significativa de descarte, de 20 por cento em 1991 para 9 por cento em 2001. A prevalência de doenças infecciosas entre doadores em 2001 foi de 0,04 por cento para vírus da imunodeficiência humana (VIH); 0,21 por cento para vírus da hepatite C (VHC); 0,06 por cento para vírus T-linfotrópico humano (HTLV); para vírus da hepatite B (VHB), as prevalências foram de 0,14 por cento para anti-HBc + HBsAg, 1,68 por cento para anti-HBc + anti-HBs e 1,67 por cento para anti-HBc isolado; 1,10 por cento para sífilis; e 0,14 por cento para doença de Chagas. CONCLUSÄO: A diminuiçäo no descarte e a prevalência de doenças infecciosas entre doadores da Fundaçäo Pró-Sangue/Hemocentro de Säo Paulo em 2001 refletem o aumento na porcentagem de doadores de repetiçäo nesse banco de sangue


Assuntos
Humanos , Bancos de Sangue/organização & administração , Doadores de Sangue , Doenças Transmissíveis/epidemiologia , Resíduos de Serviços de Saúde , Bancos de Sangue/normas , Transfusão de Sangue/normas , Brasil/epidemiologia , Prevalência
9.
Rev. panam. salud pública ; 13(2/3): 172-175, Feb.-Mar. 2003. tab
Artigo em Inglês | LILACS | ID: lil-346107

RESUMO

OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV) concomitantly using two different enzyme immunoassay (EIA) tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of Säo Paulo (Fundaçäo Pró-Sangue/Hemocentro de Säo Paulo), which is a major blood center in the city of Säo Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB) test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4 percent) had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58 percent) did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great majority of HIV-positive donors have already seroconverted and will be detected using only a single EIA screening test. Only persons who are going through the process of seroconversion may be missed by using a single EIA test and detected using two EIAs for screening. To screen out these individuals and decrease the residual risk of HIV transmission from the blood donated in our center, the use of other techniques, such as nucleic acid testing (NAT) or a p24 antigen assay, would be more effective


Assuntos
Humanos , Sorodiagnóstico da AIDS/normas , Bancos de Sangue/normas , Soropositividade para HIV/epidemiologia , Programas de Rastreamento/normas , Sorodiagnóstico da AIDS/métodos , Bancos de Sangue/legislação & jurisprudência , Doadores de Sangue/classificação , Brasil/epidemiologia , Soropositividade para HIV/diagnóstico , Técnicas Imunoenzimáticas/normas , Técnicas Imunoenzimáticas , Programas Obrigatórios , Programas de Rastreamento/legislação & jurisprudência , Avaliação de Programas e Projetos de Saúde , Controle de Qualidade
13.
Rev. UNIMAR ; 7(1): 71-84, out. 1985.
Artigo em Português | LILACS | ID: lil-29618

RESUMO

Foi estudado o efeito do ácido niflúmico sobre a metabolizaçäo do piruvato, da frutose e do glicogênio endógeno pelo fígado de rato perfundido isoladamente, tendo-se acompanhado também o consumo de oxigênio. Na faixa de concentraçäo entre 6 e 100 micron M, o ácido niflúmico ativou o consumo de oxigênio, chegando a duplicar a taxa respiratória em relaçäo ao controle, dependendo das condiçöes experimentais. Na mesma faixa de concentraçäo, o ácido niflúmico inibiu a gluconeogênese (a partir de piruvato e frutose), ativou a glicólise e a glicogenólise e aumentou a razäo L-lactato/piruvato. A frutólise foi ativada por concentraçöes até 30 micron M, tendo sido inibida por concentraçöes maiores. A respiraçäo inibida pelo cianeto näo foi mais ativada pelo ácido niflúmico; a respiraçäo sensível ao atractilosídeo, porém, foi ativada. Esses efeitos foram provavelmente devidos à açäo desacoplante do ácido niflúmico, conforme foi demonstrado previamente com mitocôndrias isoladas. Há, porém, dados que parecem indicar que, a nível de célula intata, a açäo do ácido niflúmico näo está restrita às mitocôndrias


Assuntos
Ratos , Animais , Masculino , Fígado/metabolismo , Ácido Niflúmico/farmacologia , Perfusão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...