Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(5): e0303325, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38748668

RESUMO

Since the 19th century, underwater explosions have posed a significant threat to service members. While there have been attempts to establish injury criteria for the most vulnerable organs, namely the lungs, existing criteria are highly variable due to insufficient human data and the corresponding inability to understand the underlying injury mechanisms. This study presents an experimental characterization of isolated human lung dynamics during simulated exposure to underwater shock waves. We found that the large acoustic impedance at the surface of the lung severely attenuated transmission of the shock wave into the lungs. However, the shock wave initiated large bulk pressure-volume cycles that are distinct from the response of the solid organs under similar loading. These pressure-volume cycles are due to compression of the contained gas, which we modeled with the Rayleigh-Plesset equation. The extent of these lung dynamics was dependent on physical confinement, which in real underwater blast conditions is influenced by factors such as rib cage properties and donned equipment. Findings demonstrate a potential causal mechanism for implosion injuries, which has significant implications for the understanding of primary blast lung injury due to underwater blast exposures.


Assuntos
Traumatismos por Explosões , Pulmão , Humanos , Pulmão/fisiologia , Traumatismos por Explosões/etiologia , Explosões , Lesão Pulmonar/etiologia , Masculino , Pressão , Ondas de Choque de Alta Energia/efeitos adversos
2.
Ann Biomed Eng ; 49(11): 3099-3117, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33094416

RESUMO

It is critical to understand the relationship between under-body blast (UBB) loading and occupant response to provide optimal protection to the warfighter from serious injuries, many of which affect the spine. Previous studies have examined component and whole body response to accelerative based UBB loading. While these studies both informed injury prediction efforts and examined the shortcomings of traditional anthropomorphic test devices in the evaluation of human injury, few studies provide response data against which future models could be compared and evaluated. The current study examines four different loading conditions on a seated occupant that demonstrate the effects of changes in the floor, seat, personal protective equipment (PPE), and reclined posture on whole body post-mortem human surrogate (PMHS) spinal response in a sub-injurious loading range. Twelve PMHS were tested across floor velocities and time-to-peak (TTP) that ranged from 4.0 to 8.0 m/s and 2 to 5 ms, respectively. To focus on sub-injurious response, seat velocities were kept at 4.0 m/s and TTP ranged from 5 to 35 ms. Results demonstrated that spine response is sensitive to changes in TTP and the presence of PPE. However, spine response is largely insensitive to changes in floor loading. Data from these experiments have also served to develop response corridors that can be used to assess the performance and predictive capability of new test models used as human surrogates in high-rate vertical loading experiments.


Assuntos
Modelos Biológicos , Coluna Vertebral/fisiologia , Aceleração , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Manequins , Pessoa de Meia-Idade , Equipamento de Proteção Individual , Postura , Adulto Jovem
3.
Stapp Car Crash J ; 63: 235-266, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32311059

RESUMO

Limited data exist on the injury tolerance and biomechanical response of humans to high-rate, under-body blast (UBB) loading conditions that are commonly seen in current military operations, and there are no data examining the influence of occupant posture on response. Additionally, no anthropomorphic test device (ATD) currently exists that can properly assess the response of humans to high-rate UBB loading. Therefore, the purpose of this research was to examine the response of post-mortem human surrogates (PMHS) in various seated postures to high-rate, vertical loading representative of those conditions seen in theater. In total, six PMHS tests were conducted using loading pulses applied directly to the pelvis and feet of the PMHS: three in an acute posture (foot, knee, and pelvis angles of 75°, 75°, and 36°, respectively), and three in an obtuse posture (15° reclined torso, and foot, knee, and pelvis angles of 105°, 105°, and 49.5°, respectively). Tests were conducted with a seat velocity pulse that peaked at ~4 m/s with a 30-40 ms time to peak velocity (TTP) and a floor velocity that peaked at 6.9-8.0 m/s (2-2.75 ms TTP). Posture condition had no influence on skeletal injuries sustained, but did result in altered leg kinematics, with leg entrapment under the seat occurring in the acute posture, and significant forward leg rotations occurring in the obtuse posture. These data will be used to validate a prototype ATD meant for use in high-rate UBB loading scenarios.


Assuntos
Explosões , Veículos Automotores , Postura , Acidentes de Trânsito , Autopsia , Fenômenos Biomecânicos , Cadáver , Humanos , Sujeitos da Pesquisa
4.
Biomed Sci Instrum ; 48: 194-201, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22846283

RESUMO

Under-Body Blast (UBB) has emerged as the predominant threat to ground vehicles and Warfighter survivability. The force transference from the vehicle structure to the human body has resulted in serious injuries, with the thoracolumbar spine frequently damaged. Computational models of the human body are being generated to model human response and develop injury mitigation strategies. To effectively model the spine mechanics, the thoracolumbar ligaments, which serve varying roles in contributing to spine stability, must be characterized at relevant strains and strain rates. Adaptation of cervical spine testing methods has allowed for testing of isolated spinal ligaments including the Anterior Longitudinal Ligament (ALL), Posterior Longitudinal Ligament (PLL), and Ligamentum Flavum (LF). A high-rate servo-hydraulic test machine was used to execute a tensile test protocol for 24 complexes with loading rates ranging from 240 - 2800 mm/s and displacements of 25%, 50%, 75%, 100%, and 300% of the measured ligament length. Non-contact strain field measurements were recorded to produce a three dimensional strain field of the ligament surface. In order to provide the ligament data in a form which can be incorporated in the human computational models, analytical methods for modeling the ligament response are being investigated. Ultimately, this model will be optimized to be utilized in computational models of the lumbar spine.

5.
Biomed Sci Instrum ; 48: 324-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22846301

RESUMO

Predicting spinal injury under high rates of vertical loading is of interest, but the success of computational models in modeling this type of loading scenario is highly dependent on the material models employed. Understanding the response of these biological materials at high strain rates is critical to accurately model mechanical response of tissue and predict injury. While data exists at lower strain rates, there is a lack of the high strain rate material data that are needed to develop constitutive models. The Split Hopkinson Pressure Bar (SHPB) has been used for many years to obtain properties of various materials at high strain rates. However, this apparatus has mainly been used for characterizing metals and ceramics and is difficult to apply to softer materials such as biological tissue. Recently, studies have shown that modifications to the traditional SHPB setup allow for the successful characterization of mechanical properties of biological materials at strain rates and peak strain values that exceed alternate soft tissue testing techniques. In this paper, the previously-reported modified SHPB technique is applied to characterize human intervertebral disc material under simple shear. The strain rates achieved range from 5 to 250 strain s-1. The results demonstrate the sensitivity to the disc composition and structure, with the nucleus pulposus and annulus fibrosus exhibiting different behavior under shear loading. Shear tangent moduli are approximated at varying strain levels from 5 to 20% strain. This data and technique facilitates determination of mechanical properties of intervertebral disc materials under shear loading, for eventual use in constitutive models.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...