Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Urol ; 201(6): 1144-1151, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30707130

RESUMO

PURPOSE: We assessed the frequency of preoperative and persistent microbial contamination of flexible ureteroscopes after reprocessing and the relation of contamination to cumulative ureteroscope use. MATERIALS AND METHODS: We evaluated the effectiveness of high level disinfection with peracetic acid as well as data on ureteroscope use for 20 new flexible ureteroscopes from December 2015 to December 2017 at a single center. In the operating room pre-use and postuse microbial samples of the ureteroscope shaft and working channel were collected to evaluate microbial contamination after reprocessing. Positive cultures were defined as 30 cfu/ml or greater of skin flora, or 10 cfu/ml or greater of uropathogenic microorganisms. A generalized estimating equation model was used to analyze whether cumulative ureteroscope use was associated with positive pre-use cultures. RESULTS: Microbial samples were collected during 389 procedures. Pre-use ureteroscope cultures were positive in 47 of 389 procedures (12.1%), of which uropathogens were found in 9 of 389 (2.3%) and skin flora in 38 of 389 (9.8%). Urinary tract infection symptoms did not develop in any of the patients who underwent surgery with a uropathogen contaminated ureteroscope. In 1 case the pre-use culture contained the same bacteria type as the prior postuse culture. Cumulative ureteroscope use was not associated with a higher probability of positive cultures. CONCLUSIONS: Microbial contamination of reprocessed ureteroscopes was found in an eighth of all procedures. Notably uropathogenic microorganisms were discovered in a small proportion of all procedures. Persistent ureteroscope contamination with uropathogens was only rarely encountered. Cumulative ureteroscope use was not associated with a higher probability of microbial contamination.


Assuntos
Desinfetantes , Desinfecção/métodos , Contaminação de Equipamentos , Reutilização de Equipamento/estatística & dados numéricos , Utilização de Equipamentos e Suprimentos/estatística & dados numéricos , Ácido Peracético , Ureteroscópios/microbiologia , Período Pré-Operatório , Estudos Prospectivos , Ureteroscópios/estatística & dados numéricos
2.
Eur Urol Focus ; 5(6): 1105-1111, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-29534873

RESUMO

BACKGROUND: Flexible ureteroscopy is an established treatment modality for evaluating and treating abnormalities in the upper urinary tract. Reusable ureteroscope (USC) durability is a significant concern. OBJECTIVE: To evaluate the durability of the latest generation of digital and fiber optic reusable flexible USCs and the factors affecting it. DESIGN, SETTING, PARTICIPANTS: Six new flexible USCs from Olympus and Karl Storz were included. The primary endpoint for each USC was its first repair. Data on patient and treatment characteristics, accessory device use, ureteroscopy time, image quality, USC handling, disinfection cycles, type of damage, and deflection loss were collected prospectively. INTERVENTION: Ureteroscopy. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: USC durability was measured as the total number of uses and ureteroscopy time before repair. USC handling and image quality were scored. After every procedure, maximal ventral and dorsal USC deflection were documented on digital images. RESULTS AND LIMITATIONS: A total of 198 procedures were performed. The median number of procedures was 27 (IQR 16-48; 14h) for the six USCs overall, 27 (IQR 20-56; 14h) for the digital USCs, and 24 (range 10-37; 14h) for the fiber optic USCs. Image quality remained high throughout the study for all six USCs. USC handling and the range of deflection remained good under incremental use. Damage to the distal part of the shaft and shaft coating was the most frequent reason for repair, and was related to intraoperative manual forcing. A limitation of this study is its single-center design. CONCLUSIONS: The durability of the latest reusable flexible USCs in the current study was limited to 27 uses (14h). Damage to the flexible shaft was the most important limitation to the durability of the USCs evaluated. Prevention of intraoperative manual forcing of flexible USCs maximizes their overall durability. PATIENT SUMMARY: Current flexible ureteroscopes proved to be durable. Shaft vulnerability was the most important limiting factor affecting durability.


Assuntos
Reutilização de Equipamento/estatística & dados numéricos , Ureteroscópios/tendências , Ureteroscopia/métodos , Sistema Urinário/diagnóstico por imagem , Equipamentos para Diagnóstico/estatística & dados numéricos , Reutilização de Equipamento/normas , Feminino , Tecnologia de Fibra Óptica/instrumentação , Humanos , Longevidade , Masculino , Estudos Prospectivos , Ureteroscópios/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA