Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102017, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39132006

RESUMO

Background: Chronic total occlusion (CTO) remains the most complex anatomical subset of lesions in percutaneous coronary intervention (PCI), often requiring advanced techniques and technologies, including the use of microcatheters. Methods: The BIOMICS study is a premarket first-in-human prospective, multicenter, open-label, single-arm trial investigating the safety and efficacy of a novel coronary microcatheter (BioMC, Biosensors International) in 100 patients with symptoms of ischemia undergoing elective CTO-PCI. The primary efficacy end point of the study was device success defined according to the CTO-ARC (Chronic Total Occlusion Academic Research Consortium) criteria namely the ability of the microcatheter to successfully facilitate placement of a guide wire beyond the occluded coronary segment. The primary safety end point was the incidence of in-hospital cardiac death or myocardial infarction at hospital discharge. Results: Hundred patients were recruited between March 2022 and January 2023. The primary efficacy end point was achieved in 75% of patients (95% CI, 65.3%-83.1%; P < .0001 for superiority compared to the prespecified performance goal of 54%). The primary safety end point of in-hospital cardiac death or myocardial infarction was observed in 2% of the patients. There were no study device-related coronary perforations or device failures. Conclusions: The use of a novel coronary microcatheter during CTO-PCI was associated with a high device success and an excellent safety profile.

2.
J Invasive Cardiol ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38471155

RESUMO

OBJECTIVES: Cardiac surgery for coronary artery disease was dramatically reduced during the first wave of the COVID-19 pandemic. Many patients with disease ordinarily treated with coronary artery bypass grafting (CABG) instead underwent percutaneous coronary intervention (PCI). We sought to describe 12-month outcomes following PCI in patients who would typically have undergone CABG. METHODS: Between March 1 and July 31, 2020, patients who received revascularization with PCI when CABG would have been the primary choice of revascularization were enrolled in the prospective, multicenter UK-ReVasc Registry. We evaluated the following major adverse cardiovascular events at 12 months: all-cause mortality, myocardial infarction, repeat revascularization, stroke, major bleeding, and stent thrombosis. RESULTS: A total of 215 patients were enrolled across 45 PCI centers in the United Kingdom. Twelve-month follow up data were obtained for 97% of the cases. There were 9 deaths (4.3%), 5 myocardial infarctions (2.4%), 12 repeat revascularizations (5.7%), 1 stroke (0.5%), 3 major bleeds (1.4%), and no cases of stent thrombosis. No difference in the primary endpoint was observed between patients who received complete vs incomplete revascularization (residual SYNTAX score £ 8 vs > 8) (P = .22). CONCLUSIONS: In patients with patterns of coronary disease in whom CABG would have been the primary therapeutic choice outside of the pandemic, PCI was associated with acceptable outcomes at 12 months of follow-up. Contemporary randomized trials that compare PCI to CABG in such patient cohorts may be warranted.

3.
Monaldi Arch Chest Dis ; 94(1)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37074089

RESUMO

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors. From July 2005 to April 2021, 911 patients underwent redo-AVR and 411 patients underwent valve-in-valve TAVI. There were 125 pairs for analysis after propensity score matching. The mean age was 75.2±8.5 years. In-hospital mortality was 7.2% (n=9) for redo-AVR versus 0 for valve-in-valve TAVI, p=0.002. Surgical patients suffered more post-operative complications, including intra-aortic balloon pump support (p=0.02), early re-operation (p<0.001), arrhythmias (p<0.001), respiratory and neurological complications (p=0.02 and p=0.03) and multi-organ failure (p=0.01). The valve-in-valve TAVI group had a shorter intensive care unit and hospital stay (p<0.001 for both). However, moderate aortic regurgitation at discharge and higher post-procedural gradients were more common after valve-in-valve TAVI (p<0.001 for both). Survival probabilities in patients who were successfully discharged from the hospital were similar after valve-in-valve TAVI and redo-AVR over the 6-year follow-up (log-rank p=0.26). In elderly patients with a degenerated aortic bioprosthesis, valve-in-valve TAVI provides better early outcomes as opposed to redo-AVR, although there was no difference in mid-term survival in patients successfully discharged from the hospital.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Catéteres , Reino Unido/epidemiologia , Resultado do Tratamento , Fatores de Risco , Bioprótese/efeitos adversos
4.
Interv Cardiol ; 17: e09, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35891630

RESUMO

Spontaneous coronary artery dissection (SCAD) is a less common cause of acute coronary syndrome. Pregnancy-related SCAD is uncommon, but often presents with a more severe phenotype. This report describes a 30-year-old woman with an anterior ST elevation MI, presenting 1 day postpartum. Left main stem (LMS) SCAD with extensive intramural haematoma (IMH) and resultant LMS occlusion was confirmed by angiography and intravascular imaging. Given the extent of disease, the patient underwent emergency cardiac surgery. Coronary flow was initially improved by decompressing the IMH using cutting balloons. The coronary wires were successfully left in situ during transfer in an effort to both maintain flow and allow the surgeon to identify true LMS. Ideally, SCAD can be managed conservatively given the risk of intervention worsening IMH, and hence myocardial ischaemia/MI. However, emergency revascularisation is indicated in cases of persistent ischaemia. This case demonstrates percutaneous therapies to bridge towards and help with subsequent surgical revascularisation.

5.
J Invasive Cardiol ; 34(5): E380-E389, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35394450

RESUMO

OBJECTIVES: To define the optimal implantation of the Sapien 3 (Edwards Lifesciences) transcatheter heart valve (THV), this study systematically analyzed the predeployment fluoroscopic THV position and correlated this to clinical outcomes. METHODS: This was an observational study of 279 patients treated with the Sapien 3 THV. Fluoroscopic imaging was used to categorize patients into low (n = 147), intermediate (n = 86), and high (n = 46) implantation zones. These zones were based on the relationship of the balloon marker and radiolucent line of the valve frame (line of lucency) to the annular plane at deployment. The primary outcome was the rate of permanent pacemaker implantation (PPI) at 30 days. The secondary outcomes were the rates of new left bundle-branch block (LBBB) in-hospital and all-cause mortality at 1 year. RESULTS: In the high, intermediate, and low groups, 30-day PPI rates were 4.3%, 8.1%, and 8.8% (P=.62); in-hospital LBBB rates were 10.9%, 26.7%, and 32.0% (P=.02); and all-cause mortality rates at 1 year were 3.1%, 7.3%, and 12.5% (P=.14), respectively. No differences were observed with respect to procedural success/complications or THV performance between the groups. CONCLUSION: This study demonstrates fewer conduction abnormalities for Sapien 3 valves positioned within a higher zone defined fluoroscopically by the line of lucency and balloon marker.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos
6.
Catheter Cardiovasc Interv ; 99(4): 1172-1180, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34792842

RESUMO

BACKGROUND: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. METHODS: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. RESULTS: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. CONCLUSIONS: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Irlanda , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Reino Unido
7.
Catheter Cardiovasc Interv ; 99(2): 305-313, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33942478

RESUMO

OBJECTIVES: To describe outcomes following percutaneous coronary intervention (PCI) in patients who would usually have undergone coronary artery bypass grafting (CABG). BACKGROUND: In the United Kingdom, cardiac surgery for coronary artery disease (CAD) was dramatically reduced during the first wave of the COVID-19 pandemic. Many patients with "surgical disease" instead underwent PCI. METHODS: Between 1 March 2020 and 31 July 2020, 215 patients with recognized "surgical" CAD who underwent PCI were enrolled in the prospective UK-ReVasc Registry (ReVR). 30-day major cardiovascular event outcomes were collected. Findings in ReVR patients were directly compared to reference PCI and isolated CABG pre-COVID-19 data from British Cardiovascular Intervention Society (BCIS) and National Cardiac Audit Programme (NCAP) databases. RESULTS: ReVR patients had higher incidence of diabetes (34.4% vs 26.4%, P = .008), multi-vessel disease with left main stem disease (51.4% vs 3.0%, P < .001) and left anterior descending artery involvement (94.8% vs 67.2%, P < .001) compared to BCIS data. SYNTAX Score in ReVR was high (mean 28.0). Increased use of transradial access (93.3% vs 88.6%, P = .03), intracoronary imaging (43.6% vs 14.4%, P < .001) and calcium modification (23.6% vs 3.5%, P < .001) was observed. No difference in in-hospital mortality was demonstrated compared to PCI and CABG data (ReVR 1.4% vs BCIS 0.7%, P = .19; vs NCAP 1.0%, P = .48). Inpatient stay was half compared to CABG (3.0 vs 6.0 days). Low-event rates in ReVR were maintained to 30-day follow-up. CONCLUSIONS: PCI undertaken using contemporary techniques produces excellent short-term results in patients who would be otherwise CABG candidates. Longer-term follow-up is essential to determine whether these outcomes are maintained over time.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Hirudinas , Humanos , Pandemias , Estudos Prospectivos , Proteínas Recombinantes , Sistema de Registros , SARS-CoV-2 , Resultado do Tratamento
8.
Am Heart J ; 242: 24-32, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34450050

RESUMO

BACKGROUND: Obesity is a real public health problem and is of growing concern. People are resorting to surgical or endoscopic means to fight against overweight and obesity. In recent years, there has been a marked increase in the use of these means and in particular the insertion of a gastric balloon which seems to present less risk than surgical methods. Renal complications from intragastric balloon placement are extremely rare. We report here the case of compression of the left renal vein revealed by lumbar pain and hematuria in an overweight 39-year-old woman who benefited from the balloon gastric placement one month before symptoms. The scanner made the diagnosis and showed a good evolution after the withdrawal of the balloon. METHODS: This was a prespecified and retrospective analysis of all consecutive patients who underwent FFR assessment for intermediate coronary lesions between January 2014 and December 2015. The primary endpoint was defined as the 1-year composite of cardiac death, vessel-related myocardial infarction, and clinically-driven target vessel revascularization. RESULTS: In 1554 lesions (23% in women), FFR was lower in men [0.83 ±0.09 vs 0.85 ±0.08, P = .004] driven by LAD values (for LAD P < .001, LCx or RCA P> .40). In proximal lesions (PLs), FFR was lower in men [0.83 ±0.10 vs 0.85 ±0.08, P = .004] with comparable values in non-PLs [0.84 ±0.09 vs 0.85 ±0.08, P = .36]. In PLs, the primary endpoint was higher in women [HR(adjusted) 3.18 (1.08-9.37), P = .035] with comparable outcomes in non-PLs (P = .032 for interaction). In deferred lesions, the primary endpoint was higher in women [HR(adjusted) 2.73 (1.10-6.74), P = .03] with no differences in revascularized lesions across sex (P = .02 for interaction). Results were consistent when using propensity score matching analysis. CONCLUSIONS: There is a sex-based difference in FFR, particularly in stenoses subtending large myocardium, and more evident in deferred lesions.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Balão Gástrico , Sobrepeso , Adulto , Feminino , Balão Gástrico/efeitos adversos , Humanos , Masculino , Sobrepeso/cirurgia , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
9.
JTCVS Tech ; 10: 254-261, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34977731

RESUMO

BACKGROUND: Transcatheter mitral valve implantation (TMVI) for native mitral valve pathology with severe mitral annular calcification has emerged as an alternative treatment option to conventional mitral valve surgery. The objective of this study was to evaluate patients who were referred for TMVI with severe mitral annular calcification and their procedural outcomes. METHODS: Retrospective analysis of patients from 2017 to 2020 referred for TMVI was carried out. Demographic characteristic details; surgical strategy; perioperative complications; and hospital stay, including 30-day and 1-year mortality, were analyzed. RESULTS: Eleven patients were referred for consideration of TMVI. The 8 patients who underwent TMVI had a median age of 74 years (range, 57-80 years), the median Society of Thoracic Surgeons score was 4.6 (range, 2.4-10.9), and European System for Cardiac Operative Risk Evaluation II score was 5.2% (2%-10.1%). The median cardiopulmonary bypass time and crossclamp times were 170 minutes (range, 150-248 minutes) and 152 minutes (range, 118-214 minutes), respectively. The median hospital stay was 29 days (range, 2-40 days). Thirty-day in hospital mortality was 12%, whereas 1-year mortality was 25%. There was symptomatic improvement with downgrade of New York Heart Association functional class from III or IV to I or II. The 3 patients who were turned down had a median age of 73 years, median Society of Thoracic Surgeons score was 13.4, and median European System for Cardiac Operative Risk Evaluation II score was 5.72%. They were alive at 12 months follow-up from the date of surgical assessment; however, all with New York Heart Association functional class III or IV symptoms. CONCLUSIONS: We describe a series demonstrating the technical consideration and capability of transatrial TMVI to treat mitral annular calcification and native mitral valve disease. Our results are favorable when compared with TMVI global registry data for transseptal or transapical approach.

11.
Am J Med ; 133(8): e447, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32741454
12.
J Am Heart Assoc ; 9(15): e016990, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32715844

RESUMO

Background Despite the availability of guidelines for the performance of transcatheter aortic valve implantation (TAVI), current treatment pathways vary between countries and institutions, which impact on the mean duration of postprocedure hospitalization. Methods and Results This was a prospective, multicenter registry of 502 patients to validate the appropriateness of discharge timing after transfemoral TAVI, using prespecified risk criteria from FAST-TAVI (Feasibility and Safety of Early Discharge After Transfemoral [TF] Transcatheter Aortic Valve Implantation), based on hospital events within 1-year after discharge. The end point-a composite of all-cause mortality, vascular access-related complications, permanent pacemaker implantation, stroke, cardiac rehospitalization, kidney failure, and major bleeding-was reached in 27.0% of patients (95% CI, 23.3-31.2) within 1 year after intervention; 7.5% (95% CI, 5.5-10.2) had in-hospital complications before discharge and 19.6% (95% CI, 16.3-23.4) within 1 year after discharge. Overall mortality within 1 year after discharge was 7.3% and rates of cardiac rehospitalization 13.5%, permanent pacemaker implantation 4.2%, any stroke 1.8%, vascular-access-related complications 0.7%, life-threatening bleeding 0.7%, and kidney failure 0.4%. Composite events within 1 year after discharge were observed in 18.8% and 24.3% of patients with low risk of complications/early (≤3 days) discharge and high risk and discharged late (>3 days) (concordant discharge), respectively. Event rate in patients with discordant discharge was 14.3% with low risk but discharged late and increased to 50.0% in patients with high risk but discharged in ≤3 days. Conclusions The FAST-TAVI risk assessment provides a tool for appropriate, risk-based discharge that was validated with the 1-year event rate after transfemoral TAVI. Registration URL: https://www.ClinicalTrials.gov; Unique identifier: NCT02404467.


Assuntos
Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Europa (Continente)/epidemiologia , Humanos , Estudos Prospectivos
13.
Cardiovasc Drugs Ther ; 34(5): 659-662, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32488426

RESUMO

BACKGROUND: The prognostic role of procedural complexity when discontinuing aspirin in patients on oral anticoagulation undergoing percutaneous coronary intervention (PCI) has never been studied. METHODS: Ischaemic events were compared in 256 consecutive patients according to procedural complexity and aspirin on discharge. PCI complexity was defined according to the high-risk features for ischaemic events in the current guidelines RESULTS: Forty percent patients had stable presentation. In patients with complex PCI, ischaemic events were significantly higher when discharged without aspirin (adjusted HR 3.66, (95% CI 1.07 to 12.47), P = 0.038). This was driven from both target vessel failure and de-novo coronary lesions. Ischaemic events were comparable between patients with complex PCI on aspirin and those who underwent non-complex PCI. CONCLUSIONS: Procedural complexity in patients with indication for oral anticoagulation undergoing PCI should be factored in when deciding optimal antithrombotic therapies. Aspirin discontinuation in patients with high-risk PCI features should be discouraged.


Assuntos
Anticoagulantes/administração & dosagem , Aspirina/administração & dosagem , Fibrinolíticos/administração & dosagem , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Trombose/prevenção & controle , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Aspirina/efeitos adversos , Esquema de Medicação , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Fatores de Risco , Trombose/etiologia , Trombose/mortalidade , Fatores de Tempo , Resultado do Tratamento
15.
Can J Cardiol ; 36(1): 112-118, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31785992

RESUMO

BACKGROUND: Tools are needed to identify patients at increased risk after transcatheter aortic valve replacement (TAVR). Indexed stroke volume (SVi) is an echocardiographic measurement that is used for low-gradient aortic stenosis. We studied whether low SVi is a high-risk marker in patients with high-gradient aortic stenosis (HG-AS) and assessed the relationship between SVi and left ventricle (LV) systolic function in contributing to this risk. METHODS: A total of 816 consecutive patients who underwent TAVR were screened, and only patients with HG-AS were included. Low flow (LF) was defined as SVi ≤ 35 mL/m2. The primary endpoint was defined as a combination of all-cause mortality and readmission with heart failure at 1 year. RESULTS: Of the 476 patients with HG-AS, 215 (45%) had LF. They had higher N-terminal pro b-type natriuretic peptide (NTproBNP) (2565 [1037-5492] vs 1730 [818-3575], P = 0.006) and smaller indexed valve area (0.30 ± 0.10 vs 0.37 ± 0.10 cm2/m2, P < 0.001) when compared with normal flow patients. The primary endpoint was higher in LF patients (hazard ratio, 1.49; 95% confidence interval, 1.01-2.21; P = 0.045). There were no statistical differences in the individual components of death (13.0% vs 8.9%, P = 0.16) or heart failure (14.9% vs 10.1%, P = 0.12). When stratified according to LV function, low SVi was associated with future adverse events in patients with reduced function (hazard ratio, 3.37; 95% confidence interval, 1.26-8.98; P = 0.015) with comparable clinical outcomes in those with preserved function. LF was an independent predictor of adverse events in the reduced LV function subgroup. CONCLUSIONS: SVi can further characterize patients with HG-AS and may help to identify those who are at increased risk after TAVR.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Sístole
16.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713325

RESUMO

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Pericárdio/transplante , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Irlanda , Masculino , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
17.
World J Cardiol ; 11(7): 189-194, 2019 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-31565194

RESUMO

BACKGROUND: High-speed rotational atherectomy (HSRA) is most commonly used to modify calcified coronary artery lesions to facilitate stent deployment and expansion. The use of HSRA as an emergency rescue technique to release a fractured micro-catheter has not been described. We report the use of HSRA in a case of a fracture trapped corsair tip that was impeding coronary flow causing a ST elevation myocardial infarct. CASE SUMMARY: A 79 years old male was scheduled for elective percutaneous coronary intervention (PCI) to his left anterior descending artery (LAD). Given its calcific nature, a decision was made for upfront rotablation. During procedural preparations, the tip of an employed micro-catheter was separated from the shaft resulting in obstructing coronary flow and ST-segment elevation. The consensus was for an attempt bail out PCI strategy. A rotafloppy wire was advanced to the distal LAD using a corsair micro-catheter which was placed proximal to the occlusion site. Modification of the mid LAD segment was performed, resulting in mobilising the corsair tip, and deflecting it to a small diagonal branch. Following serial predilation, the procedure was completed using two overlapping drug eluting stents, jailing the corsair tip in the diagonal branch. The patient made uneventful recovery and was clinically stable at one year follow up. CONCLUSION: HSRA may be offered as a bailed-out strategy to rescue fractured and jailed micro-catheter tip in high risk surgical cases.

19.
Congenit Heart Dis ; 14(5): 846-853, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31489769

RESUMO

OBJECTIVE: A significant body of patients who have undergone Mustard or Senning procedure require lifelong follow up. In this retrospective review, we examined the cohort of such patients currently attending our center. DESIGN: Patients who had undergone either Mustard or Senning procedure were identified. We retrospectively reviewed medical records, recorded demographic information and data regarding the clinical state, NHYA class, cardiopulmonary exercise testing, NT-proBNP measurement, and recent cardiac MRI findings. RESULTS: Forty-six patients were identified, the mean age was 32.2 years (± 6.1 years), 67.4% were male. Thirty-two patients (69.6%) had undergone a Senning procedure. The median length of the follow-up was 32 years. Thirty-two patients (69.6%) were NHYA class 1. The mean VO2max achieved was 24.2 ± 5.8 mL/min/kg. The mean NT-proBNP was 266.4 pg/mL (± 259.9 pg/mL). The mean right ventricular end-diastolic volume (RVEDV) was 212.4 mL ± 73.1 mL (indexed 114.2 mL/m2  ± 34.4 mL/m2 ). The mean right ventricular ejection fraction (RVEF) was 53.7% ± 7.9%. The mean left ventricular end-diastolic volume (LVEDV) was 161.5 mL ± 73.7 mL (indexed 87.8 mL/m2  ± 41.1 mL/m2 ). The mean left ventricular ejection fraction (LVEF) was 59.8% ± 5.7%. There was a significant correlation between right ventricular (RV) size on MRI and NT-proBNP level. CONCLUSIONS: We present a relatively well cohort of patients with overall favorable long-term outcome. The majority of patients are NHYA class 1 and the systemic right ventricular function appears to be well preserved as assessed by MRI. The exercise tolerance is reduced, with the majority of patients achieving around 60% of the estimated VO2max . Regular specialist follow-up and assessment with advanced imaging at regular intervals remain important for this group.


Assuntos
Transposição das Grandes Artérias/métodos , Tolerância ao Exercício/fisiologia , Previsões , Volume Sistólico/fisiologia , Transposição dos Grandes Vasos/cirurgia , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Imagem Cinética por Ressonância Magnética , Masculino , Estudos Retrospectivos , Transposição dos Grandes Vasos/diagnóstico , Transposição dos Grandes Vasos/fisiopatologia , Resultado do Tratamento , Adulto Jovem
20.
Am J Med ; 132(12): e827-e834, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31152721

RESUMO

BACKGROUND: Eosinopenia is considered a surrogate of inflammation in several disease settings. Following ST-segment elevation myocardial infarction, eosinopenia is presumed to be a marker of infarct severity. We sought to study the relationship between eosinopenia and infarct severity and how this relationship determined the long-term outcomes following ST-segment elevation myocardial infarction. METHODS: Six hundred and six consecutive patients undergoing primary percutaneous coronary interventions from a large volume single center were enrolled. Low eosinophil count was defined as < 40 cells/mL from samples within 2 hours after reperfusion. Primary endpoint was defined as composite of death, myocardial infarction, stroke, unplanned revascularization, and readmission for heart failure over 3.5 years' follow-up. RESULTS: Sixty-five percent of the patients had eosinopenia. Patients in the low eosinophil group had larger infarct size as measured by troponin value (2934 vs 1177 ng/L, P < .001) and left ventricle systolic function on echocardiography (48% vs 50%, P = 0.029). There was a weak correlation between eosinophil count and both troponin (r = -0.25, P < 0.001) and ejection fraction (r = 0.10, P = .017). The primary endpoint was higher in eosinopenic patients (28.8% vs. 20.4%; hazard ratio [HR] 1.49, 95% confidence interval [CI] 1.05 to 2.13, P = .023). A discordance between eosinopenia and severe left ventricle systolic dysfunction was observed in 55.6% of cases. Compared with normal count, eosinopenia was associated with worse clinical outcomes in patients with non-severe left ventricle dysfunction (24.1% vs 16.2%; HR 1.58, 95% CI 1.01 to 2.45, P = .044) but not in those with severe left ventricle dysfunction (42.3% vs. 38.9%; HR 1.10, 95% CI 0.59 to 2.03, P = .77) (P < .01 for interaction). CONCLUSIONS: Eosinopenia is an easily determined marker that reflects worse clinical outcomes over long-term follow-up.


Assuntos
Agranulocitose/sangue , Eosinófilos/citologia , Mortalidade Hospitalar , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Idoso , Biomarcadores/sangue , Estudos de Coortes , Angiografia Coronária/métodos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Feminino , Hospitalização , Hospitais com Alto Volume de Atendimentos , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Medição de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA