Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Biomed Mater Eng ; 34(5): 459-472, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37005873

RESUMO

BACKGROUND: Magnesium (Mg) enhances the bone regeneration, mineralization and attachment at the tissue/biomaterial interface. OBJECTIVE: In this study, the effect of Mg on mineralization/osseointegration was determined using (Ti,Mg)N thin film coated Ti6Al4V based plates and screws in vivo. METHODS: TiN and (Ti,Mg)N coated Ti6Al4V plates and screws were prepared using arc-PVD technique and used to fix rabbit femur fractures for 6 weeks. Then, mineralization/osseointegration was assessed by surface analysis including cell attachment, mineralization, and hydroxyapatite deposition on concave and convex sides of the plates along with the attachment between the screw and the bone. RESULTS: According to Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) analyses; cell attachment and mineralization were higher on the concave sides of the plates from both groups in comparison to the convex sides. However, mineralization was significantly higher on Mg-containing ones. The mean gray value indicating mineralized area after von Kossa staining was found as 0.48 ± 0.01 and 0.41 ± 0.04 on Mg containing and free ones respectively. Similarly, Fourier Transform Infrared Spectroscopy (FTIR) and X-ray diffraction (XRD) analyses showed that hydroxyapatite growth was abundant on the Mg-containing and concave sides of the plates. Enhanced mineralization and strong attachment to bone were also detected in EDS and SEM analyses of Mg-containing screws. CONCLUSION: These findings indicated that (Ti,Mg)N coatings can be used to increase attachment at the implant tissue interface due to accelerated mineralization, cell attachment, and hydroxyapatite growth.


Assuntos
Magnésio , Titânio , Animais , Coelhos , Magnésio/farmacologia , Titânio/química , Materiais Revestidos Biocompatíveis/química , Osseointegração , Durapatita/química , Microscopia Eletrônica de Varredura , Fêmur/cirurgia , Propriedades de Superfície
2.
Sci Rep ; 13(1): 3204, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36828989

RESUMO

Patellar luxation with condylar defect is a challenging situation for reconstruction in humans. Patella reluxation, cartilage damage and pain are the most common complications. This study aims to present a new patient specific method of overformed implant design and clinical implantation that prevents luxation of patella without damaging the cartilage in a dog. Design processes are Computer Tomography, Computer Assisted Design, rapid prototyping of the bone replica, creation of the implant with surgeon's haptic knowledge on the bone replica, 3D printing of the implant and clinical application. The implant was fully seated on the bone. Patella reluxation or implant-related bone problem was not observed 80 days after the operation. However, before the implant application, there were soft tissue problems due to previous surgeries. Three-point bending test and finite element analysis were performed to determine the biomechanical safety of the implant. The stress acting on the implant was below the biomechanical limits of the implant. More cases with long-term follow-up are needed to confirm the success of this method in patellar luxation. Compared with trochlear sulcoplasty and total knee replacement, there was no cartilage damage done by surgeons with this method, and the implant keeps the patella functionally in sulcus. This is a promising multidisciplinary method that can be applied to any part of the bone and can solve some orthopaedic problems with surgeon's haptic knowledge.


Assuntos
Artroplastia do Joelho , Luxação Patelar , Humanos , Animais , Cães , Fêmur/cirurgia , Patela/cirurgia , Artroplastia do Joelho/efeitos adversos , Luxação Patelar/cirurgia , Cartilagem/cirurgia
3.
J Biomed Mater Res B Appl Biomater ; 109(2): 227-237, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32770599

RESUMO

Magnesium (Mg) based implants such as plates and screws are often preferred to treat bone defects because of the positive effects of magnesium in bone growth and healing. Their low corrosion resistance, however, leads to fast degradation and consequently failure before healing was completed. Previously, we developed Mg doped titanium nitrate (TiN) thin film coatings to address these limitations and demonstrated that <10 at% Mg doping led to enhanced mineralization in vitro. In the present study, in vivo performance of (Ti,Mg)N coated Ti6Al4V based plates and screws were studied in the rabbit model. Bone fractures were formed on femurs of 16 rabbits and then fixed with either (Ti,Mg)N coated (n = 8) or standard TiN coated (n = 8) plates and screws. X-ray imaging and µCT analyses showed enhanced bone regeneration on fracture sites fixed with (Ti,Mg)N coated plates in comparison with the Mg free ones. Bone mineral density, bone volume, and callus volume were also found to be 11.4, 23.4, and 42.8% higher, respectively, in accordance with µCT results. Furthermore, while TiN coatings promoted only primary bone regeneration, (Ti,Mg)N led to secondary bone regeneration in 6 weeks. These results indicated that Mg presence in the coatings accelerated bone regeneration in the fracture site. (Ti,Mg)N coating can be used as a practical method to increase the efficiency of existing bone fixation devices of varying geometry.


Assuntos
Ligas/química , Placas Ósseas , Parafusos Ósseos , Materiais Revestidos Biocompatíveis/química , Fraturas do Fêmur/cirurgia , Consolidação da Fratura , Magnésio/química , Titânio/química , Animais , Modelos Animais de Doenças , Masculino , Coelhos
4.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 58: e182908, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1363086

RESUMO

Many complicated bone fractures can be healed by different techniques including linear external fixation. New generation linear external fixators enhanced the scope of application for bone fractures by mechanical progress. Difficulties include implementing enough pins through fixation clamps to the comminuted fragments or clamp addition and fixing it properly to the rod with the correct pin insertion angle. Effective configurations may not always result. This study sought to reveal the clinical efficiency of modified clamps of a versatile external fixator (VEF) to fix different types of fractures and orthopedic problems according to the radiographic and clinical results. We used this fixator on 17 cats and 17 dogs of different ages and sizes, having different types of antebrachium, humerus, tibia, ulna fractures, and bone-muscle deformities. Clamps had different features to connect fixator pins. Many fixator configurations were created according to the fracture type and body weight of the animals. The most used ones were unilateral and bilateral configurations. The callus formation and visual gait analysis were observed after the operations, until the removal of the fixator. After fixator removal, the visual gait status of the limbs was excellent in 67% of the cases, good in 15%, fair in 12%, and poor in 6%. We found that rods and fixator pins were connected easily by semi-locked clamps. Also, the double pin holding clamps saved space on the fixation rod by the application of two pins through one clamp. We think that clamps of versatile external fixators can easily be constructed to limb fractures and save time during surgery.(AU)


Diversas fraturas ósseas complicadas podem ser tratadas por diferentes técnicas, incluindo fixadores externos lineares. Os fixadores externos lineares de nova geração aumentaram o escopo de aplicação para fraturas ósseas devido ao progresso mecânico. A dificuldade é implementar um número suficiente de pinos através de clamps de fixação aos fragmentos osseos ou adição de clamps com fixação adequadamente à haste com o ângulo correto de inserção do pino. As configurações eficazes nem sempre podem ser realizadas. Este estudo pretendia revelar a eficácia clínica das clamps modificadas de um fixador externo versátil para corrigir diferentes tipos de fraturas e problemas ortopédicos de acordo com os resultados radiográficos e clínicos. O fixador foi utilizado em 17 gatos e 17 cães de diferentes idades e tamanhos, com diferentes tipos de antebraço, úmero, tíbia, fratura de ulna e deformidades ósseo-musculares. Os clamps tinham recursos diferentes para conectar os pinos do fixador. Muitas configurações de fixadores foram criadas de acordo com o tipo de fratura e peso corporal dos animais. As mais utilizadas foram as configurações unilateral e bilateral. A formação do calo e a análise visual da marcha foram observadas após as cirurgias, até a retirada do fixador. Após a retirada do fixador, a utilização dos membros foi excelente em 67% dos casos, bom em 15% dos casos, regular em 12% dos casos, ruim em 6% dos casos. Concluímos que as hastes e os pinos do fixador foram facilmente conectados por clamps semi-travados. Além disso, os clamps de fixação de pino duplo economizaram espaço na haste de fixação com a aplicação de dois pinos em clamp. Acreditamos que os clamps de fixadores externos versáteis podem ser facilmente construídas para fraturas de membros, economizando tempo na cirurgia.(AU)


Assuntos
Animais , Gatos , Cães , Fixadores Externos/veterinária , Fraturas Ósseas/terapia , Fraturas Ósseas/veterinária , Resultado do Tratamento
5.
J Biol Inorg Chem ; 24(2): 191-210, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30673878

RESUMO

Zinc(II) (5), indium(III) (6), and lutetium(III) (7) phthalocyanines (Pcs) peripherally substituted with poly (ethylene glycol) (PEG) monomethyl ether 2000 (PEGME-2000) blocks were synthesized via Sonogashira coupling reaction with high yields and their photophysical, photochemical and photobiological properties were investigated. We elucidated the interactions of these compounds with calf thymus DNA and bovine serum albumin (BSA), and determined K(DNA) and K(BSA) binding constants at degrees of 105 and 106, respectively. Singlet oxygen quantum yields were found (Ф∆ = 0.44, 0.54, and 0.68 for 5, 6, and 7, respectively). Thermodynamic parameters, as well as thermal denaturation profile of double-stranded CT-DNA were examined to determine the type of binding mode. According to our experimental data, we report that PEGME-2000 favors the formation of binary complex between DNA, and phthalocyanine complexes. Therein, thermodynamic data suggest that this binding mode is indeed spontaneous under reported conditions, and rather non-specific. Additionally, Pcs 5, 6, and 7 substituted with PEGME-2000 blocks showed antimicrobial activity against Gram-positive and Gram-negative bacteria, as well as fungi (yeast), and Pc 5 had the highest antimicrobial activity among them, as revealed by disc diffusion assay results. In short, our results suggest that these compounds could be used for photodynamic therapy, they have both antibacterial and antifungal activity, and the binding ability of new phthalocyanines 5, 6, and 7 with BSA paves the way for their utilization as drug vehicle in blood plasma.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Fármacos Fotossensibilizantes/farmacologia , Animais , Antibacterianos/síntese química , Antibacterianos/química , Antifúngicos/síntese química , Antifúngicos/química , Bovinos , DNA/química , Éteres/química , Éteres/farmacologia , Fungos/efeitos dos fármacos , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Índio/química , Índio/farmacologia , Indóis/química , Indóis/farmacologia , Isoindóis , Lutécio/química , Lutécio/farmacologia , Testes de Sensibilidade Microbiana , Compostos Organometálicos/química , Compostos Organometálicos/farmacologia , Processos Fotoquímicos , Fármacos Fotossensibilizantes/síntese química , Fármacos Fotossensibilizantes/química , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Soroalbumina Bovina/química , Compostos de Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...